Improving abdomen tumor low-dose CT images using a fast dictionary learning based processing
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
In abdomen computed tomography (CT), repeated radiation exposures are often inevitable for cancer patients who receive surgery or radiotherapy guided by CT images. Low-dose scans should thus be considered in order to avoid the harm of accumulative x-ray radiation. This work is aimed at improving abdomen tumor CT images from low-dose scans by using a fast dictionary learning (DL) based processing. Stemming from sparse representation theory, the proposed patch-based DL approach allows effective suppression of both mottled noise and streak artifacts. The experiments carried out on clinical data show that the proposed method brings encouraging improvements in abdomen low-dose CT images with tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robust Face Recognition via Sparse Representation
Wright, J., Yang, A. Y., Ganesh, A., Sastry, S. S., & Ma, Y. (2009) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2008.79 · Cited by 9,388
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Emergence of simple-cell receptive field properties by learning a sparse code for natural images
Olshausen, B. A., & Field, D. J. (1996) · Nature · doi:10.1038/381607a0 · Cited by 5,694
Image Denoising Via Sparse and Redundant Representations Over Learned Dictionaries
Elad, M., & Aharon, M. (2006) · IEEE Transactions on Image Processing · doi:10.1109/tip.2006.881969 · Cited by 5,321
Optimally sparse representation in general (nonorthogonal) dictionaries via ℓ 1 minimization
Donoho, D. L., & Elad, M. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0437847100 · Cited by 2,898
Smith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
Sparse Representation for Color Image Restoration
Mairal, J., Elad, M., & Sapiro, G. (2008) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.911828 · Cited by 1,716 · cited 1×
“Recent years have witnessed a growing interest in the study of sparse and redundant representations over dictionary learning (DL) [25-32].”
BackgroundLearning Overcomplete Representations
Lewicki, M. S., & Sejnowski, T. J. (2000) · Neural Computation · doi:10.1162/089976600300015826 · Cited by 1,129
Strategies for CT Radiation Dose Optimization
Kalra, M. K., Maher, M. M., Toth, T. L., Hamberg, L. M., Blake, M. A., Shepard, J.-A., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2303021726 · Cited by 1,080
MR Image Reconstruction From Highly Undersampled k-Space Data by Dictionary Learning
Ravishankar, S., & Bresler, Y. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2090538 · Cited by 1,059
A three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
X-ray phase-contrast imaging: from pre-clinical applications towards clinics
Bravin, A., Coan, P., & Suortti, P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/1/r1 · Cited by 846
Dictionary Learning Algorithms for Sparse Representation
Kreutz-Delgado, K., Murray, J. F., Rao, B. D., Engan, K., Lee, T.-W., & Sejnowski, T. J. (2003) · Neural Computation · doi:10.1162/089976603762552951 · Cited by 838 · cited 5×
“In Kalra et al (2003, 2004), several edge-preserving noise reduction filters were proposed to enhance the conspicuity of lesions in abdomen LDCT images. An adaptive noise reduction filtering which combines smoothing and edge-enhancing was reported in Funama et al (2006) to gain 50% dose reduction (tube current reduced…”
BackgroundMethodInfluentialLow-Dose X-ray CT Reconstruction via Dictionary Learning
Xu, Q., Yu, H., Mou, X., Zhang, L., Hsieh, J., & Wang, G. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2195669 · Cited by 690
Silva, A. C., Lawder, H. J., Hara, A., Kujak, J., & Pavlicek, W. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.2953 · Cited by 560
Learning Multiscale Sparse Representations for Image and Video Restoration
Mairal, J., Sapiro, G., & Elad, M. (2008) · Multiscale Modeling & Simulation · doi:10.1137/070697653 · Cited by 460 · cited 1×
“Recent years have witnessed a growing interest in the study of sparse and redundant representations over dictionary learning (DL) [25-32].”
BackgroundReducing Abdominal CT Radiation Dose With Adaptive Statistical Iterative Reconstruction Technique
Prakash, P., Kalra, M. K., Kambadakone, A., et al. (2010) · Investigative Radiology · doi:10.1097/rli.ob013e3181dzfeec · Cited by 366 · cited 2×
“should be noted that results of clinical value in abdomen LDCT have been achieved by using the PICCS algorithm [17] and the adaptive statistical iterative reconstruction (ASIR) [18-19].”
MethodIterative reconstruction for helical CT: a simulation study
Nuyts, J., Man, B. D., Dupont, P., Defrise, M., Suetens, P., & Mortelmans, L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/003 · Cited by 291 · cited 1×
“Reconstruction approaches treat the LDCT imaging as an ill-posed inverse problem, and solve the problem via maximizing a prior-regularized cost function using iterative optimizations [11-19].”
MethodFaigel, G., & Tegze, M. (1999) · Reports on Progress in Physics · doi:10.1088/0034-4885/62/3/002 · Cited by 266
Chen, Y., Gao, D., Nie, C., Luo, L., Chen, W., Yin, X., & Lin, Y. (2009) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2008.12.007 · Cited by 158
Self-citationKalra, M. K., Maher, M. M., Sahani, D. V., Blake, M. A., Hahn, P. F., Avinash, G. B., Toth, T. L., Halpern, E. F., & Saini, S. (2003) · Radiology · doi:10.1148/radiol.2281020693 · Cited by 154
Thoracic low-dose CT image processing using an artifact suppressed large-scale nonlocal means
Chen, Y., Yang, Z., Hu, Y., Yang, G., Zhu, Y., Li, Y., luo, L., Chen, W., & Toumoulin, C. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/9/2667 · Cited by 143 · cited 1×
“This LNLM method was further combined with a multiscale directional diffusion to suppress the streak artifacts in thoracic CT images [24].”
MethodSelf-citationNonlocal Prior Bayesian Tomographic Reconstruction
Chen, Y., Ma, J., Feng, Q., Luo, L., Shi, P., & Chen, W. (2007) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-007-0042-5 · Cited by 131 · cited 2×
“Reconstruction approaches treat the LDCT imaging as an ill-posed inverse problem, and solve the problem via maximizing a prior-regularized cost function using iterative optimizations [11-19].”
BackgroundMethodSelf-citationKalra, M. K., Maher, M. M., Blake, M. A., Lucey, B. C., Karau, K. L., Toth, T. L., Avinash, G. B., Halpern, E. F., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2323031563 · Cited by 104 · cited 1×
“In [20-21], several noise reduction filters were proposed to enhance the conspicuity of lesions in abdomen LDCT images.”
BackgroundYang, C., Chen, W., Yin, X., Ye, X., Bao, X., Luo, L., Feng, Q., li, Y., & Xiao-e, Y. (2010) · European Journal of Radiology · doi:10.1016/j.ejrad.2010.07.003 · Cited by 87 · cited 5×
“TABLE I THE PARAMETER SETTINGS AND COMPUTATION COST (IN SECOND) FOR THE LNLM METHOD IN [23] AND THE PROPOSED MET HOD”
BackgroundMethodInfluentialSelf-citationLubner, M. G., Pickhardt, P. J., Tang, J., & Chen, G. (2011) · Radiology · doi:10.1148/radiol.11101380 · Cited by 83 · cited 3×
“should be noted that results of clinical value in abdomen LDCT have been achieved by using the PICCS algorithm [17] and the adaptive statistical iterative reconstruction (ASIR) [18-19].”
BackgroundMethodAn Efficient Dictionary Learning Algorithm and Its Application to 3-D Medical Image Denoising
Li, S., Fang, L., & Yin, H. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2173935 · Cited by 76
Segmenting CT prostate images using population and patient‐specific statistics for radiotherapy
Feng, Q., Foskey, M. S., Chen, W., & Shen, D. G. (2010) · Medical Physics · doi:10.1118/1.3464799 · Cited by 75
Wang, J., Lu, H., Wen, J., & Liang, Z. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909531 · Cited by 72
Artifacts In Spiral X-Ray Ct Scanners: Problems And Solutions
Yazdi, M., & Beaulieu, L. (2007) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.1080244 · Cited by 59
Ehman, E. C., Guimarães, L., Fidler, J. L., Takahashi, N., Ramírez-Giraldo, J. C., Yu, L., Manduca, A., Huprich, J. E., McCollough, C. H., Holmes, D. R., et al. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.6987 · Cited by 43
Cited by
Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network
Chen, H., Zhang, Y., Kalra, M. K., Lin, F., Chen, Y., Liao, P., Zhou, J., & Wang, G. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2715284 · Cited by 1,866
Self-citationYang, Q., Yan, P., Zhang, Y., Yu, H., Shi, Y., Mou, X., Kalra, M. K., Zhang, Y., Sun, L., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2827462 · Cited by 1,630
aLow-dose CT via convolutional neural network
Chen, H., Zhang, Y., Zhang, W., Liao, P., Li, K., Zhou, J., & Wang, G. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000679 · Cited by 755
Sharpness-Aware Low-Dose CT Denoising Using Conditional Generative Adversarial Network
Yi, X., & Babyn, P. (2018) · Journal of Digital Imaging · doi:10.1007/s10278-018-0056-0 · Cited by 343
Li, M., Hsu, W., Xie, X., Cong, J., & Gao, W. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2968472 · Cited by 321
Metadata
- Authors
- Chen, Y., Yin, X., Shi, L., Shu, H., Luo, L., Coatrieux, J.-L., & Toumoulin, C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2013-08-06
- Volume
- 58
- Issue
- 16
- Pages
- 5803-5820
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2142884793
- Cited by
- 223
- References
- 33
- FWCI
- 10.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.