Development of a new generation of high-resolution anatomical models for medical device evaluation: the Virtual Population 3.0
Open accessThe DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.
Abstract
The Virtual Family computational whole-body anatomical human models were originally developed for electromagnetic (EM) exposure evaluations, in particular to study how absorption of radiofrequency radiation from external sources depends on anatomy. However, the models immediately garnered much broader interest and are now applied by over 300 research groups, many from medical applications research fields. In a first step, the Virtual Family was expanded to the Virtual Population to provide considerably broader population coverage with the inclusion of models of both sexes ranging in age from 5 to 84 years old. Although these models have proven to be invaluable for EM dosimetry, it became evident that significantly enhanced models are needed for reliable effectiveness and safety evaluations of diagnostic and therapeutic applications, including medical implants safety. This paper describes the research and development performed to obtain anatomical models that meet the requirements necessary for medical implant safety assessment applications. These include implementation of quality control procedures, re-segmentation at higher resolution, more-consistent tissue assignments, enhanced surface processing and numerous anatomical refinements. Several tools were developed to enhance the functionality of the models, including discretization tools, posing tools to expand the posture space covered, and multiple morphing tools, e.g., to develop pathological models or variations of existing ones. A comprehensive tissue properties database was compiled to complement the library of models. The results are a set of anatomically independent, accurate, and detailed models with smooth, yet feature-rich and topologically conforming surfaces. The models are therefore suited for the creation of unstructured meshes, and the possible applications of the models are extended to a wider range of solvers and physics. The impact of these improvements is shown for the MRI exposure of an adult woman with an orthopedic spinal implant. Future developments include the functionalization of the models for specific physical and physiological modeling tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Each model is made up of over 300 tissues, with a supporting database of electromagnetic properties for each tissue.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The Virtual Population [30] is a set of human models for electromagnetic simulations that have been created for these purposes.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
The cited source says what the claim attributes to it.
In the citing paper
“MR-induced heating ISCTs using the virtual patients such as the Virtual Population [30] often focus validation efforts on the device model (e.g., clause 8.7.5 in ISO/TS 10974 [28]), rather than the patient model or coupled device-patient model.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“The assignment of the dielectric tissue properties at 64 MHz was done according to the material database (see section 2.2.4), which includes work presented in Gabriel et al (1996), and all metallic parts of the coil and the implant were treated as perfect electrical conductors.”
MethodInfluentialde Onís, M., Onyango, A. W., Borghi, E., Siyam, A., Pinol, A., Garza, C., Martines, J., Martorell, R., Victora, C. G., Bhan, M. K., et al. (2006) · (2006) · Cited by 3,401
Lanczos Filtering in One and Two Dimensions
Duchon, C. E. (1979) · Journal of Applied Meteorology · doi:10.1175/1520-0450(1979)018<1016:lfioat>2.0.co;2 · Cited by 2,398 · cited 3×
“It was tuned with lumped elements placed at the end rings between the rungs to match previously performed measurements (Cabot et al 2013). Due to the high resolution required by the implant and the large simulation domain required by the birdcage coil, the computation was performed in two steps: the fields in the bird…”
MethodInfluentialEfficient Management of Parallelism in Object-Oriented Numerical Software Libraries
Balay, S., Gropp, W. D., McInnes, L. C., & Smith, B. F. (1997) · Modern Software Tools for Scientific Computing · doi:10.1007/978-1-4612-1986-6_8 · Cited by 2,009 · cited 1×
“Dedicated high performance computing-enabled solvers, based on the PETSc framework (Balay et al 1997), have been developed for this purpose.”
MethodReport of the task group on reference man
(1979) · Annals of the ICRP · doi:10.1016/0146-6453(79)90123-4 · Cited by 1,706
Medical Image Computing and Computer-Assisted Intervention
Yang, G., Hawkes, D. J., Rueckert, D., Noble, J. A., & Taylor, C. (2009) · Research Explorer (The University of Manchester) · Cited by 1,591
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439 · cited 2×
“Pregnant women models at three gestational stages presented in Christ et al (2012) are included in the Virtual Population.”
BackgroundMethodSelf-citationComputerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Automatic three‐dimensional mesh generation by the finite octree technique
Shephard, M. S., & Georges, M. K. (1991) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.1620320406 · Cited by 732
amira: A Highly Interactive System for Visual Data Analysis
STALLING, D., WESTERHOFF, M., & HEGE, H.-C. (2005) · Visualization Handbook · doi:10.1016/b978-012387582-2/50040-x · Cited by 569 · cited 1×
“Also, the surface extraction and processing have been updated: previously, the surface extraction, simplification, and smoothing routines from the Amira software (Stalling et al 2005) were used.”
Method
Research works printed but not linked: 6
- Benkler S, Chavannes N and Kuster N 2009 New powerful FDTD source based on Huygens surface: highly complex EM simulations performed on an ordinary PC Abstract Collection of BioEM 2009 Davos: the Joint Meeting of the Bioelectromagnetics Society and the European BioElectromagnetics Association (Davos, Switzerland 14-19 June) (Poster presentation P-262 in Poster session 2: Theoretical and Practical Modeling (June 16)) pp 736-7
- Cherubini E, Chavannes N and Kuster N 2008 Realistic skeleton based deformation of high-resolution anatomical human models for electromagnetic simulation BEMS 2008: Abstracts of the 30th Annu. Meeting of the Bioelectromagnetics Society (San Diego, CA, USA, 9-12 June) pp 505-7 (Poster Presentation P-149 in Poster Session: Theoretical and Practical Modeling) (10 June))
- Cristy M 1980 Mathematical phantoms representing children of various ages for use in estimates of internal dose Oak Ridge National Laboratory Technical Report ORNL (Oak Ridge, TN: ORNL)
- Neufeld E, Szczerba D and Kuster N 2013b Mechanical simulation-based approach for realistic model shape and posture parametrization CP'13: 4th Int. Workshop on Computational Phantoms for Radiation Protection, Imaging and Radiotherapy (Zurich, 20-22 May) pp 14-5
- Sempé M, Pédron G and Roy-Pernot M-P 1979 Auxologie: méthode et séquences Théraplix (Paris: Theraplix)
- Spurway J F, 2004, ASUM Ultrasound Bull., 7, 15
Cited by
Items 301–400 of 601
Effect of Realistic Body Models on Plane Wave Reflection at mmWaves
Colella, M., Meo, S. D., Pasian, M., Liberti, M., & Apollonio, F. (2023) · IEEE MTT-S International Microwave Biomedical Conference (IMBioC) · doi:10.1109/imbioc56839.2023.10305090 · Cited by 4
“The reference model considered was the ViP male model Duke (Virtual Population v.3.1) [16].”
MethodInfluentialShi, L., Liang, J., Liu, Y., Zhao, Y., & Li, X. (2024) · Electronics · doi:10.3390/electronics13040740 · Cited by 4
Pluim, J. M. E., van de Kamer, J. B., Heeling, E., van der Ploeg, I. M. C., & Hulsen, D. J. W. (2025) · Physics in Medicine and Biology · doi:10.1088/1361-6560/adaacf · Cited by 4
“…phantoms are available that can be used to study the organ specific absorption of electromagnetic exposure and ionizing radiation in particular (Gosselin et al 2014, Xu 2014, Makarov et al 2017, Kainz et al 2018), including those specifically designed for pregnancy and fetal exposure (Chen…”
Oblique Plane Wave Exposure at 24 GHz of an Advanced Female Anthropomorphic Model
Dolciotti, N., Colella, M., D’Agostino, S., Apollonio, F., & Liberti, M. (2025) · IEEE Wireless Power Technology Conference and Expo (WPTCE) · doi:10.1109/wptce62521.2025.11062195 · Cited by 4
“Indeed, most anatomical models are derived from supine MRI imaging, CT scans, or a combination of these on healthy subjects placed in a supine position [19] - [25].”
Córcoles, J., Zastrow, E., & Kuster, N. (2017) · URSI General Assembly and Scientific Symposium · doi:10.23919/ursigass.2017.8105232 · Cited by 4
Self-citationA numerical assessment of the human body effect in the transmission of wireless microphones
Cabot, E., Stevanović, I., Kuster, N., & Capstick, M. H. (2018) · Microwave and Optical Technology Letters · doi:10.1002/mop.31623 · Cited by 4
Self-citationBottauscio, O., Arduino, A., Chiampi, M., & Zilberti, L. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107316 · Cited by 4
Influence of patient head definition on induced E‐fields during MR examination
Goren, T., Reboux, S., Farcito, S., Lloyd, B., & Kuster, N. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29894 · Cited by 4
Self-citationLocal SAR management strategies to use two‐channel RF shimming for fetal MRI at 3 T
Yetişir, F., Türk, E. A., Adalsteinsson, E., Wald, L. L., & Grant, P. E. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29913 · Cited by 4
Jabban, L., Zhang, D., & Metcalfe, B. (2021) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner49283.2021.9441299 · Cited by 4
“The use of Sim4life enables access to high-resolution anatomical models [11] with preset biological material properties [12].”
MethodZanoli, M., & Trefná, H. D. (2021) · European Conference on Antennas and Propagation · doi:10.23919/eucap51087.2021.9411435 · Cited by 4
“family of the IT’IS Foundation [11], [12], and their content is filled with a material exhibiting dielectric properties equal”
Backgroundvan Leeuwen, C. C., Steensma, B. R., Glybovski, S., Lunenburg, M., Simovski, C. R., Klomp, D. W. J., van den Berg, C. A. T., & Raaijmakers, A. J. E. (2021) · Frontiers in Physics · doi:10.3389/fphy.2021.716521 · Cited by 4
MR Conditionality of Abandoned Leads from Active Implantable Medical Devices at 1.5T
Wang, Y., Guo, R., Hu, W., Jiang, J., Kainz, W., & Chen, J. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630892 · Cited by 4
Self-citationKim, D., Ahn, J., & Ahn, S. (2022) · Journal of electromagnetic engineering and science · doi:10.26866/jees.2022.2.r.74 · Cited by 4
Proposed Safety Guidelines for Patient Assistants in an Open MRI Environment
Oh, S., Hong, S., & Choi, H. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192215185 · Cited by 4
Chiaramello, E., Brusquet, L. L., Parazzini, M., Fiocchi, S., Bonato, M., & Ravazzani, P. (2019) · Bioelectromagnetics · doi:10.1002/bem.22179 · Cited by 4
Modeling of Exposure to Low-Frequency Electromagnetic Fields of Workers in Arbitrary Posture
Gubernati, A. C., Freschi, F., Giaccone, L., Scorretti, R., Seppecher, L., & Vial, G. (2020) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2949391 · Cited by 4
MATSUO, S., Komeya, K., MATSUKI, Y., & Shikanai, S. (1967) · Journal of the Ceramic Association Japan · doi:10.2109/jcersj1950.75.864_241 · Cited by 4
Bauer, A. (2016) · theses.fr (ABES) · doi:10.70675/27fd1f01zbc1ez49b5za115za31f26ec57dd · Cited by 4
“0 [60, 150], composée de modèles de tout types : femmes moyennes, hommes moyens, enfants, obèses, etc.”
Petersen, E. J., Elliott, J. T., Bancos, S., Caldwell, B., Khajotia, S. S., Kleinstreuer, N. C., Margerrison, E., & Pfeifer, C. (2022) · ALTEX · doi:10.14573/altex.2206241 · Cited by 4
Clinical applications of the kT-points method to homogenise spin excitation in 3T MRI
Tomi-Tricot, R. (2018) · theses.fr (ABES) · doi:10.70675/85292318z77bez4ebaz87d2z9955c801a459 · Cited by 4
Karadeniz, N., Hajnal, J. V., & İpek, Ö. (2024) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-024-01212-4 · Cited by 3
The Impact of 9.375 GHz Microwave Radiation on the Emotional and Cognitive Abilities of Mice
Wang, X., Zhao, X., Xu, J., Li, M., Sun, B., Gao, A., Zhang, L., Wu, S., Liu, X., Zou, D., et al. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26072871 · Cited by 3
“The horn antenna, acrylic circular box, and mice were modeled using Sim4life [37] based on the FDTD algorithm The mouse model selected was the 24.7 g Diggy Male Nude Normal Mouse Model developed by the IT’TS Foundation [38].”
InfluentialAdvances in Female Chest Modeling: Enhanced 3D Dosimetric Models Across Two Illustrative Scenarios
Dolciotti, N., D’Agostino, S., Colella, M., Apollonio, F., & Liberti, M. (2025) · Bioelectromagnetics · doi:10.1002/bem.70034 · Cited by 3
Robust-Sub-Gaussian Model Predictive Control for Safe Ultrasound-Image-Guided Robotic Spinal Surgery
Ao, Y., Prajapat, M., As, Y., Taoudi-Benchekroun, Y., Carrillo, F., Esfandiari, H., Grewe, B. F., Krause, A., & Fürnstahl, P. (2026) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2026.3673984 · Cited by 3
“Specifically, our pipeline includes a novel uncertainty propagation method that separately characterizes biases and variance of noise, employing robust set propagation techniques for the former and sub-Gaussian approaches for the latter.”
Tsanidis, G., & Samaras, T. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab9fc7 · Cited by 3
Hernandez, D., Kim, D., Nam, T., Jeong, Y., Seo, M., Lee, E., Kim, J. H., & Kim, K. (2023) · IEEE Access · doi:10.1109/access.2023.3326822 · Cited by 3
“A human model (DUKE) provided by the simulation software [29] was used to compute the B1 field and SAR maps for each coil configuration.”
MethodWi-Fi Enabled Textile and Wearable Antennas for Healthcare Devices
Noghanian, S., Alemaryeen, A., Shadid, R., & Ali, S. M. (2024) · Advances in medical technologies and clinical practice book series · doi:10.4018/979-8-3693-4026-4.ch001 · Cited by 3
Dudysheva, N., Luong, M., Amadon, A., Morel, L., Touz, N. L., Vignaud, A., Boulant, N., & Gras, V. (2025) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ada683 · Cited by 3
“Identical SAR simulations were also performed on Thelonius (6 years old boy, height 1.15 m, weight 18.6 kg) and Billie (11 years old girl, height 1.49 m, weight 34 kg) models of the ‘Virtual Family’ v 2.0.1 (Gosselin et al 2014).”
InfluentialDong, X., Ren, Y., & Lu, M. (2025) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaf013 · Cited by 3
Investigation of electrical conductivity changes during brain functional activity in 3T MRI
Jung, K., Cui, C., Lee, S.-H., Park, C.-H., Chun, J., & Kim, D. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121174 · Cited by 3
“…den Bergen et al., 2009) was employed to generate a cylinder phantom with an infinite z-direction and the FDTD electro-magnetic simulation program, Sim4Life (Christ et al., 2010; Gosselin et al., 2014) (Zurich Med Tech, Zurich, Switzerland), to generate heterogeneous brain in-silico (Duke) data.”
Urban, M. W., & Orglmeister, R. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856693 · Cited by 3
“x models) were provided by the Foundation for Research on Information Technologies in Society (IT'IS) [7] [8].”
MethodAngelis, A. D., Leonetti, M., Apollonio, F., Liberti, M., Aglioti, S. M., & Ruocco, G. (2021) · Applied Physics Letters · doi:10.1063/5.0052743 · Cited by 3
Improved Calculation Method of Coupling Factors for Low-Frequency Wireless Power Transfer Systems
Ahn, J., Hong, S., Kim, H., Song, K., Choi, H., & Ahn, S. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19010044 · Cited by 3
Petzold, J., Schmitter, S., Silemek, B., Winter, L., Speck, O., Ittermann, B., & Seifert, F. C. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29932 · Cited by 3
Advanced Computational Modelling of Female Breast and 2.45 GHz Exposure
Dolciotti, N., Colella, M., D’Agostino, S., Apollonio, F., & Liberti, M. (2023) · IEEE Conference on Antenna Measurements and Applications (CAMA) · doi:10.1109/cama57522.2023.10352728 · Cited by 3
6G RIS in Indoor Environments: Assessment of Exposure Variability in Human Users and Non-Users
Gallucci, S., Benini, M., Fiocchi, S., Tognola, G., & Parazzini, M. (2025) · IEEE Open Journal of Antennas and Propagation · doi:10.1109/ojap.2025.3529980 · Cited by 3
“SAR was assessed in five human models of the Virtual Population (ViP) [22] of both genders and age in the range 3-34 years.”
InfluentialIndustrial indoor massive MIMO human EM-exposure evaluation
Shikhantsov, S., Thielens, A., Vermeeren, G., Tanghe, E., Demeester, P., Torfs, G., Martens, L., & Joseph, W. (2018) · Ghent University Academic Bibliography (Ghent University) · Cited by 3
Non-Invasive Heart Beat Measurement Using Microwave Resonators
Essingholt, F., Meyer, F., Kuhn, P., Schmidt, P., Benkner, T., & Grabmaier, A. (2018) · EUROSENSORS Conference (EUROSENSORS) · doi:10.3390/proceedings2131002 · Cited by 3
Numerical study on MRI RF-induced heating for the trauma screw implanted in three human models
Xia, M., Zheng, J., & Chen, J. (2020) · IEEE International Symposium on Electromagnetic Compatibility · doi:10.1109/emcsi38923.2020.9191563 · Cited by 3
“The specifications of the three human models are shown in TABLE I [13].”
MethodIrastorza, R. M., Bovaira, M., García‐Vitoria, C., Muñoz, V., & BERJANO, E. J. (2021) · International Journal of Hyperthermia · doi:10.1080/02656736.2021.1974580 · Cited by 3
“This human model consists of 22 files in stl format obtained using Whole-body Magnetic Resonance Imaging (WB-MRI) according to a protocol presented in [14].”
BackgroundMethodSAR and thermal distribution of pregnant woman and child inside elevator cabin
Karatsi, I., Bakogianni, S., & Koulouridis, S. (2022) · International Journal of Microwave and Wireless Technologies · doi:10.1017/s1759078722000253 · Cited by 3
Xi, J., Christ, A., & Kuster, N. (2022) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aca875 · Cited by 3
Self-citationFrom Image-Based Modeling to the Modeling of Imaging with the Virtual Population
Neufeld, E., Lloyd, B., & Kuster, N. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-46630-9_5 · Cited by 3
Self-citationPophof, B., & Brix, G. (2017) · Der Radiologe · doi:10.1007/s00117-017-0260-9 · Cited by 3
“Hierfür wurde eine virtuelle Population von Körpermodellen unterschiedlichen Geschlechts und Alters entwickelt [12].”
Stochastic Exposure Assessment to 4G LTE Femtocell in Indoor Environments
Chiaramello, E., Parazzini, M., Fiocchi, S., Bonato, M., Ravazzani, P., & Wiart, J. (2018) · URSI Atlantic Radio Science Conference · doi:10.23919/ursi-at-rasc.2018.8471419 · Cited by 3
Evaluating exposure from electric fields in a high voltage switchyard according to the EU directive
Hamnerius, Y., Nilsson, T., & Friman, E. (2019) · Journal of Radiological Protection · doi:10.1088/1361-6498/aaf817 · Cited by 3
Fiocchi, S., Chiaramello, E., Bonato, M., Tognola, G., Catalucci, D., Parazzini, M., & Ravazzani, P. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857364 · Cited by 3
Tomographic Approach to Human Hydration Assessment: In Silico Proof-of-Concept
Besler, B. C., & Fear, E. C. (2021) · International Symposium on Antenna Technology and Applied Electromagnetics · doi:10.1109/antem51107.2021.9518530 · Cited by 3
Miniature antennas for biomedical applications
Nikolayev, D. (2017) · theses.fr (ABES) · doi:10.70675/6323cff1za131z4e8bzb5dbzfa2f4d2e65ce · Cited by 3
Herssens, H., & Thielens, A. (2025) · IEEE Access · doi:10.1109/access.2025.3555388 · Cited by 2
“Two different heterogeneous phantoms are used in this paper, i.e., the ViP Duke and Ella phantoms [17].”
Using mixed-fidelity to create effective environments
Opie, J., Jaufuraully, S., Fernandez, C. S., Mahendran, L., Desjardins, A. E., Siassakos, D. M., David, A. L., Tiwari, M. K., & BLANDFORD, A. E. (2025) · Cognition Technology & Work · doi:10.1007/s10111-025-00797-7 · Cited by 2
“When evaluating the context of use for a novel medical device, phantoms or mannequins are commonly used as they provide a high-level of realism (DeWerd and Kissick 2014; Keenan et al. 2024; Gosselin et al. 2014).”
Design of a Compact 868 MHz On-Body Matched Antenna for Relaying Biomedical Implants
Yang, Y., Vermeeren, G., & Joseph, W. (2025) · European Conference on Antennas and Propagation · doi:10.23919/eucap63536.2025.10999965 · Cited by 2
“Its performance is evaluated using three anatomically distinct Virtual Population (ViP) models—Duke [6], Billie [7], and Ella [6].”
Akter, M. K., Shen, A., Islam, M. Z., Zheng, J., Steckner, M., & Chen, J. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30578 · Cited by 2
“Three AIMD systems and four PIMD systems were positioned inside anatomically detailed human body models—Duke (adult male, 37 years), Ella (adult female, 26 years), and Fats (adult obese male, 37 years) 23 —in clinically relevant implant configurations.”
InfluentialGallucci, S., Benini, M., Bonato, M., Galletta, V., Chiaramello, E., Fiocchi, S., Tognola, G., & Parazzini, M. (2025) · Sensors · doi:10.3390/s25144461 · Cited by 2
“Colella et al. [17] investigated the power absorbed when using the common flat model and an adult virtual human model (‘Duke’ from the Virtual Population (ViP) [18]), in three anatomical districts when exposed to mmWave frequencies.”
InfluentialFresnel, E., Bouisset, N., Soyka, F., Alteköster, C., Prato, F. S., & Legros, A. G. (2025) · Scientific Reports · doi:10.1038/s41598-025-12284-0 · Cited by 2
“0 (male, 33 y, 1.62 m, 64.5 kg; IT’IS Foundation, Zurich, Switzerland) from the Virtual Population family, a set of high-resolution anatomical models generated based on MRI data from healthy volunteers, was used 35 (Fig.”
InfluentialLow frequency magnetic field induction factors for exposure assessment in the human hand
Schneeweiss, P., Hirtl, R., & Schmid, G. (2025) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ae0118 · Cited by 2
Evaluation of Exposure Assessment Methods and Procedures for Induction Hobs
Xi, J., Kühn, S., Fortunato, C., Ofli, E., & Kuster, N. (2025) · Bioelectromagnetics · doi:10.1002/bem.70024 · Cited by 2
“The ViP models used in this study (except the fetuses) are shown in Figure 9, and detailed information about the models is summarized in Table 4 (Gosselin et al. 2014).”
Self-citationEgger, N., Ruck, L., Nagelstraßer, S., Schirmer, J., Wildenberg, S., Bitz, A. K., Herrler, J., Schmitter, S., Uder, M., & Nagel, A. M. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70101 · Cited by 2
“16 The transmit efficiencies were used to calculate channel-wise GT FA distributions 𝛼 n ( r ) at different reference voltages U ref , based on: Assuming a square pulse and using a nominal FA α nom of 8 ◦ .”
Bellosono, L., Colella, M., D’Agostino, S., Contessa, G. M., Polichetti, A., Liberti, M., & Apollonio, F. (2025) · International Conference on Electromagnetics in Advanced Applications (ICEAA) · doi:10.1109/iceaa65662.2025.11305933 · Cited by 2
Designing B 1 ‐Selective Pulses by Frequency Modulating in a Second Rotating Frame
Kantesaria, S., Torres, E., Mustafa, M. M., Idiyatullin, D., Ponticorvo, S., Adriany, G., Michaeli, S., & Garwood, M. (2026) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70259 · Cited by 2
“Full-wave 3D EM simulations [21] 𝐵 + 1 and SAR (Figure S4) demonstrate that a single curved double-loop coil can produce the same 𝛾 B + 1 ∕ 2 𝜋 attained at 9.4T of 1000 Hz approximately halfway into the head at 0.7 T.”
InfluentialMicrowave Focusing With Temporal Interference for Noninvasive Deep Brain Stimulation
Söderström, M., Carlsson, M., Nicolausson, P., & Dalarsson, M. (2026) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2026.3722231 · Cited by 2
“In the present work, we used the anatomical head model Duke, from the IT’IS Virtual Population [43].”
Maurya, S., Goldberg, I., & Schmidt, R. (2026) · Advanced Science · doi:10.1002/advs.77378 · Cited by 2
“To investigate this phenomenon, EM simulations were conducted using the virtual human model “Ella” [ 55 ], with head dimensions scaled to 0.9 × , 1.0 × , and 1.1 × of the original size.”
InfluentialNumerical Analysis of Ultrasound Tomography and Frequency Optimization in Human Abdomen Model
Liu, H., Ren, S., & Dong, F. (2018) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2018.8438768 · Cited by 2
“5 mm3 [10].”
Liu, H., Ren, S., & Dong, F. (2018) · Chinese Control Conference (CCC) · doi:10.23919/chicc.2018.8483408 · Cited by 2
Urban, M. W., & Orglmeister, R. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856954 · Cited by 2
“x models) were provided by the Foundation for Research on Information Technologies in Society (IT'IS) [9] [10].”
MethodRadhakrishnan, V., Robinson, M. P., Fiorentino, N. M., Patil, S. B., & Pelah, A. (2025) · Scientific Reports · doi:10.1038/s41598-025-89586-w · Cited by 2
“These deformations also depend on the volume of soft tissues 55 , resulting in potentially different deformations between Ella-22 and Ella-30 models.”
A high-resolution pediatric female whole-body numerical model with comparison to a male model
Ntolkeras, G., Jeong, H., Zöllei, L., Dmytriw, A. A., Purvaziri, A., Lev, M. H., Grant, P. E., & Bonmassar, G. (2022) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aca950 · Cited by 2
“In fact, since 1950, when the first generations of computational models were introduced, there have been advances in model design and fabrication to meet the increasing needs in the medical and other industries (Gosselin et al 2014).”
BackgroundMethodInfluentialCHANG, J., Zhang, S., QIU, X., Huang, H., Zhang, Y., & Li, K. (2023) · Technology and Health Care · doi:10.3233/thc-230995 · Cited by 2
“According to a literature review, the relevant electrical parameters of other tissues [27,28,29] are presented in Table 1.”
Hasani, A., Ibarra, B., Snodderly, K. L., Rottach, D. R., Qian, B.-F., Porter, D. A., & Guha, S. (2024) · PLoS ONE · doi:10.1371/journal.pone.0307879 · Cited by 2
Cuff Electrode Impacts on Vagus Nerve Stimulation Threshold Under MR Gradient Coil Emission
Yang, L., Yang, X., Guo, R., Zheng, J., Ye, H., Kaula, N. F., & Chen, J. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10781632 · Cited by 2
Dosimetric Electromagnetic Safety of People With Implants: A Neglected Population?
Kranold, L., Xi, J., Goren, T., & Kuster, N. (2025) · Bioelectromagnetics · doi:10.1002/bem.70023 · Cited by 2
“0 (Gosselin et al. 2014) is exposed to the dipole source.”
Self-citationDosimetry study of anatomical pregnant woman & fetus models inside three different elevator cabins
Karatsi, I., & Koulouridis, S. (2015) · European Conference on Antennas and Propagation · Cited by 2
Shape-based multi-region segmentation framework: application to 3D infants MRI data
Dahdouh, S., & Bloch, I. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2082038 · Cited by 2
Uncertainty propagation in phaseless electric properties tomography
Arduino, A., Bottauscio, O., Chiampi, M., & Zilberti, L. (2019) · International Conference on Electromagnetics in Advanced Applications (ICEAA) · doi:10.1109/iceaa.2019.8879147 · Cited by 2
RF induced energy for partially implanted catheters: A computational study
Lucano, E., Liberti, M., Lloyd, T. D. R., Apollonio, F., Wedan, S., Kainz, W., & Angelone, L. M. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7590934 · Cited by 2
“2a) [6], which is part of the Virtual Family 3.”
BackgroundSelf-citationJung, K.-J., Shim, J.-H., Choi, M., & Byun, J.-K. (2017) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2017.2742602 · Cited by 2
Virtual Humans for antenna/implant modeling
Noetscher, G. M., Yanamadala, J., Tankaria, H. V., Makarov, S. N., Louie, S., Prokop, A., & Nazarian, A. (2017) · Digest - IEEE Antennas and Propagation Society. International Symposium · doi:10.1109/apusncursinrsm.2017.8072154 · Cited by 2
“The most comprehensive model family in Table I is certainly the virtual population from IT’IS Foundation Switzerland [7,8].”
BackgroundMonitoring of Microwave Ablation treatment with Electrical Impedance Tomography
Katrioplas, K., & Samaras, T. (2018) · World Conference on Biomedical Applications of Electromagnetic Fields (EMF-Med) · doi:10.23919/emf-med.2018.8526043 · Cited by 2
“Simulations were based on a realistic human model (‘Ella’) with 1mm resolution MRI belonging to the Virtual Population models family [5].”
BackgroundMethodLi, C., Ye, Z., Wei, Y., & Wu, T. (2019) · Bioelectromagnetics · doi:10.1002/bem.22178 · Cited by 2
Ortego-Isasa, I., Martins, A., Birbaumer, N., & Ramos‐Murguialday, A. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8717038 · Cited by 2
Physical layer authentication of off‐body channels by probabilistic neural networks
Raida, Z. (2019) · International Journal of Numerical Modelling Electronic Networks Devices and Fields · doi:10.1002/jnm.2628 · Cited by 2
Ahn, J., Hong, S., Kim, H., Chun, Y., Choi, H., Kim, K.-B., Brito, A., Choi, J., & Ahn, S. (2020) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaa008 · Cited by 2
Three-dimensional Electrodynamic Model of the Human Chest
Semernik, I. V., Dem’yanenko, A. V., & Евгеньевна, С. О. (2020) · IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering · doi:10.1109/eiconrus49466.2020.9039392 · Cited by 2
Registration-based Construction of a Whole-body Human Phantom Library for Anthropometric Modeling
Sun, X., Wang, H., & Ristaniemi, T. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175295 · Cited by 2
“The first type of individual modeling requires manual segmentation of hundreds tissues from medical image, which takes months to build an individual model [2].”
BackgroundAfuwape, O. F., Runge, J., & Jiles, D. C. (2021) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2021.3092370 · Cited by 2
“1) used in this study were sourced from the Computable Virtual Population Models from the Information Technologies in Society (IT'IS) foundation database [20].”
MethodWhole-brain imaging with receive-only multichannel top-hat dipole antenna RF coil at 7 T MRI
Kumar, S., Yoon, J.-S., Kim, J. M., Lee, C., & Oh, C. (2022) · Journal of the Korean Physical Society · doi:10.1007/s40042-021-00334-5 · Cited by 2
Hardy, B. M., Banik, R., Yan, X., & Anderson, A. W. (2022) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2022.07.009 · Cited by 2
Auto-Induced, Radiofrequency, Downlink Exposure Focused at the Human Ear
Herssens, H., & Thielens, A. (2023) · European Microwave Conference (EuMC) · doi:10.23919/eumc58039.2023.10290507 · Cited by 2
“The simulations to assess the a-DL exposure are performed with the Finite-Difference Time-Domain method in Sim4Life (ZMT, Z¨urich, Switzerland) using the ViP Duke and Ella heterogeneous phantoms [4] with dielectric parameters found in [5].”
MethodYao, A., Pei, Y., He, J., Wang, J. M., & Yang, P. (2023) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2023.3337437 · Cited by 2
Tsanidis, G., & Samaras, T. (2024) · Applied Sciences · doi:10.3390/app14020786 · Cited by 2
Mathematical methods for magnetic resonance based electric properties tomography
Arduino, A. (2018) · PORTO@Iris · doi:10.6092/polito/porto/2698325 · Cited by 2
Garrett, D. C. (2018) · Libraries and Cultural Resources (University of Calgary) · doi:10.11575/prism/33085 · Cited by 3
Campara, M. J. V. (2021) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.85.2021.tde-10032022-144112 · Cited by 2
An Optimization Framework for the Design of Radiofrequency Coils for Magnetic Resonance ImagingPreprint
Serrallés, J. E. C., Giannakopoulos, I. I., Wang, S., Chen, D., Zint, D., Panozzo, D., Zorin, D., & Lattanzi, R. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.08.04.668545 · Cited by 2
Alashqar, A., Brihmat, N., Gemar, V., Hu, Z., Koh, S.-R., Diaz-Pier, S., de Freitas, R. M., Sasaki, A., Milosevic, M., Keesey, R., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.01.22.701010 · Cited by 2
Self-citationElectrical Impedance and Ultrasound Dual-Mode Tomography for Human Abdomen
Han, J., Ren, S., Dong, F., & Zhao, S. (2020) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc43012.2020.9129129 · Cited by 1
“The parameters of human abdominal tissue are shown in the Table II [16].”
MethodAn in silico testbed for fast and accurate MR labeling of orthopedic implants
Noetscher, G. M., Serano, P. J., Horner, M., Prokop, A., Hanson, J. M., Fujimoto, K., Brown, J. E., Nazarian, A., Ackerman, J. L., & Makaroff, S. N. (2023) · eLife · doi:10.7554/elife.90440.3 · Cited by 1
Impact of Patient Body Posture on RF-Induced Energy Absorption by Orthopedic Plates
Yang, X., Zheng, J., Kainz, W., Chen, X., & Chen, J. (2024) · Concepts in Magnetic Resonance Part B · doi:10.1155/2024/7418643 · Cited by 1
Self-citationD’Agostino, S., Campioni, S., Falsaperla, R., Liberti, M., & Apollonio, F. (2024) · URSI Atlantic Radio Science Conference · doi:10.46620/ursiatrasc24/ieun5409 · Cited by 1
“The operator is here represented by a human male model Jeduk, member of the Virtual Population (ViP)[7], [8] available in the Sim4Life V7.”
Method
Metadata
- Authors
- Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., Cherubini, E., Szczerba, D., Kainz, W., & Kuster, N.
- Affiliations
- ETH Zurich (CH)
- Foundation for Research on Information Technologies in Society (CH)
- United States Food and Drug Administration (US)
- Corresponding author
- Gosselin, Marie-Christine
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-08-21
- Volume
- 59
- Issue
- 18
- Pages
- 5287-5303
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2102862641
- Cited by
- 520
- References
- 52
- Citations by year
- 2026: 34 · 2025: 64 · 2024: 44 · 2023: 50 · 2022: 61 · 2021: 52 · 2020: 53 · 2019: 45 · 2018: 42 · 2017: 35 · 2016: 20 · 2015: 14 · 2014: 3
- FWCI
- 12.45
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- European Commission (FP7/2007, 282891)
- Eidgenössische Technische Hochschule Zürich
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
- Keywords
- virtual population, MRI safety, spinal implants, surface processing, electromagnetic dosimetry, radiofrequency exposure, unstructured grid
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Child, Child, Preschool, Computer Simulation, Equipment and Supplies, Female, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Male, Middle Aged, Models, Anatomic, Models, Theoretical, Radiometry, Surface Properties, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.