Development of a new generation of high-resolution anatomical models for medical device evaluation: the Virtual Population 3.0
Open accessThe DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.
Abstract
The Virtual Family computational whole-body anatomical human models were originally developed for electromagnetic (EM) exposure evaluations, in particular to study how absorption of radiofrequency radiation from external sources depends on anatomy. However, the models immediately garnered much broader interest and are now applied by over 300 research groups, many from medical applications research fields. In a first step, the Virtual Family was expanded to the Virtual Population to provide considerably broader population coverage with the inclusion of models of both sexes ranging in age from 5 to 84 years old. Although these models have proven to be invaluable for EM dosimetry, it became evident that significantly enhanced models are needed for reliable effectiveness and safety evaluations of diagnostic and therapeutic applications, including medical implants safety. This paper describes the research and development performed to obtain anatomical models that meet the requirements necessary for medical implant safety assessment applications. These include implementation of quality control procedures, re-segmentation at higher resolution, more-consistent tissue assignments, enhanced surface processing and numerous anatomical refinements. Several tools were developed to enhance the functionality of the models, including discretization tools, posing tools to expand the posture space covered, and multiple morphing tools, e.g., to develop pathological models or variations of existing ones. A comprehensive tissue properties database was compiled to complement the library of models. The results are a set of anatomically independent, accurate, and detailed models with smooth, yet feature-rich and topologically conforming surfaces. The models are therefore suited for the creation of unstructured meshes, and the possible applications of the models are extended to a wider range of solvers and physics. The impact of these improvements is shown for the MRI exposure of an adult woman with an orthopedic spinal implant. Future developments include the functionalization of the models for specific physical and physiological modeling tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Each model is made up of over 300 tissues, with a supporting database of electromagnetic properties for each tissue.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The Virtual Population [30] is a set of human models for electromagnetic simulations that have been created for these purposes.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
The cited source says what the claim attributes to it.
In the citing paper
“MR-induced heating ISCTs using the virtual patients such as the Virtual Population [30] often focus validation efforts on the device model (e.g., clause 8.7.5 in ISO/TS 10974 [28]), rather than the patient model or coupled device-patient model.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“The assignment of the dielectric tissue properties at 64 MHz was done according to the material database (see section 2.2.4), which includes work presented in Gabriel et al (1996), and all metallic parts of the coil and the implant were treated as perfect electrical conductors.”
MethodInfluentialde Onís, M., Onyango, A. W., Borghi, E., Siyam, A., Pinol, A., Garza, C., Martines, J., Martorell, R., Victora, C. G., Bhan, M. K., et al. (2006) · (2006) · Cited by 3,401
Lanczos Filtering in One and Two Dimensions
Duchon, C. E. (1979) · Journal of Applied Meteorology · doi:10.1175/1520-0450(1979)018<1016:lfioat>2.0.co;2 · Cited by 2,398 · cited 3×
“It was tuned with lumped elements placed at the end rings between the rungs to match previously performed measurements (Cabot et al 2013). Due to the high resolution required by the implant and the large simulation domain required by the birdcage coil, the computation was performed in two steps: the fields in the bird…”
MethodInfluentialEfficient Management of Parallelism in Object-Oriented Numerical Software Libraries
Balay, S., Gropp, W. D., McInnes, L. C., & Smith, B. F. (1997) · Modern Software Tools for Scientific Computing · doi:10.1007/978-1-4612-1986-6_8 · Cited by 2,009 · cited 1×
“Dedicated high performance computing-enabled solvers, based on the PETSc framework (Balay et al 1997), have been developed for this purpose.”
MethodReport of the task group on reference man
(1979) · Annals of the ICRP · doi:10.1016/0146-6453(79)90123-4 · Cited by 1,706
Medical Image Computing and Computer-Assisted Intervention
Yang, G., Hawkes, D. J., Rueckert, D., Noble, J. A., & Taylor, C. (2009) · Research Explorer (The University of Manchester) · Cited by 1,591
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439 · cited 2×
“Pregnant women models at three gestational stages presented in Christ et al (2012) are included in the Virtual Population.”
BackgroundMethodSelf-citationComputerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Automatic three‐dimensional mesh generation by the finite octree technique
Shephard, M. S., & Georges, M. K. (1991) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.1620320406 · Cited by 732
amira: A Highly Interactive System for Visual Data Analysis
STALLING, D., WESTERHOFF, M., & HEGE, H.-C. (2005) · Visualization Handbook · doi:10.1016/b978-012387582-2/50040-x · Cited by 569 · cited 1×
“Also, the surface extraction and processing have been updated: previously, the surface extraction, simplification, and smoothing routines from the Amira software (Stalling et al 2005) were used.”
Method
Research works printed but not linked: 6
- Benkler S, Chavannes N and Kuster N 2009 New powerful FDTD source based on Huygens surface: highly complex EM simulations performed on an ordinary PC Abstract Collection of BioEM 2009 Davos: the Joint Meeting of the Bioelectromagnetics Society and the European BioElectromagnetics Association (Davos, Switzerland 14-19 June) (Poster presentation P-262 in Poster session 2: Theoretical and Practical Modeling (June 16)) pp 736-7
- Cherubini E, Chavannes N and Kuster N 2008 Realistic skeleton based deformation of high-resolution anatomical human models for electromagnetic simulation BEMS 2008: Abstracts of the 30th Annu. Meeting of the Bioelectromagnetics Society (San Diego, CA, USA, 9-12 June) pp 505-7 (Poster Presentation P-149 in Poster Session: Theoretical and Practical Modeling) (10 June))
- Cristy M 1980 Mathematical phantoms representing children of various ages for use in estimates of internal dose Oak Ridge National Laboratory Technical Report ORNL (Oak Ridge, TN: ORNL)
- Neufeld E, Szczerba D and Kuster N 2013b Mechanical simulation-based approach for realistic model shape and posture parametrization CP'13: 4th Int. Workshop on Computational Phantoms for Radiation Protection, Imaging and Radiotherapy (Zurich, 20-22 May) pp 14-5
- Sempé M, Pédron G and Roy-Pernot M-P 1979 Auxologie: méthode et séquences Théraplix (Paris: Theraplix)
- Spurway J F, 2004, ASUM Ultrasound Bull., 7, 15
Cited by
Items 501–600 of 601
Computational techniques in bio-electromagnetics: theory and perspectives
Fiocchi, S., Chiaramello, E., Bonato, M., Gallucci, S., Benini, M., Tognola, G., Dossi, L., Parazzini, M., & Ravazzani, P. (2022) · IEEE Mediterranean Electrotechnical Conference (MELECON) · doi:10.1109/melecon53508.2022.9842938
Efficient Tier 4 Compliance Evaluation of Inductive WPT Systems
Xi, J., & Kuster, N. (2022) · 2022 Wireless Power Week (WPW) · doi:10.1109/wpw54272.2022.9853920
Self-citationModeling Studies of Cervical Thoracic Sympathetic Nerve Magnetic StimulationPreprint
Wang, J., Xiao, S., Xing, H., & Kong, Q. (2022) · Research Square · doi:10.21203/rs.3.rs-2127901/v1
RF safety assessment in ultra-high field MRI: New approaches to reduce local SAR estimation errors
Meliadò, E. F. (2023) · Utrecht University Repository (Utrecht University) · doi:10.33540/1928
A Simulation Study of Capacitive Body-Coupled Communication along Human Limbs
Thielens, A. (2023) · USNC-URSI Radio Science Meeting · doi:10.23919/usnc-ursi54200.2023.10289218
“This section is organized as follows: first the settings of the simulations using a cylindrical and an adult male anatomical phantom, the virtual family male (VFM) [4], are presented.”
MethodNumerical Evaluation of Miniaturized Coils for Focal Magnetic Stimulation
Colella, M., Press, D. Z., Laher, R. M., McIlduff, C. E., Rutkove, S. B., Cassara, A. M., Apollonio, F., Pascual‐Leone, Á., Liberti, M., & Bonmassar, G. (2023) · URSI General Assembly and Scientific Symposium · doi:10.46620/ursigass.2023.3339.kgvd4968
Author Response: An in silico testbed for fast and accurate MR labeling of orthopedic implants
Noetscher, G. M., Serano, P. J., Horner, M., Prokop, A., Hanson, J. M., Fujimoto, K., Brown, J. E., Nazarian, A., Ackerman, J. L., & Makaroff, S. N. (2023) · eLife · doi:10.7554/elife.90440.3.sa3
Fernandes, L. O., Germer, C. M., & de Oliveira, P. X. (2023) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-49401-7_26
Tsanidis, G., & Samaras, T. (2024) · Applied Sciences · doi:10.3390/app14020629
EMF of cardiac implants at low frequencies 50 Hz in a normative context
Zhou, M. (2023) · theses.fr (ABES) · doi:10.70675/d136a4ddz111dz4c37zbfd1ze7af66632781
Author Response: An In-Silico Testbed for Fast and Accurate MR Labeling of Orthopaedic Implants
Noetscher, G. M., Serano, P. J., Horner, M., Prokop, A., Hanson, J. M., Fujimoto, K., Brown, J. E., Nazarian, A., Ackerman, J. L., & Makaroff, S. N. (2023) · doi:10.7554/elife.90440.2.sa3
People with Implants: A Neglected Population by EM Exposure Regulation?
Kranold, L., Jingtian, X., Goren, T., & Kuster, N. (2024) · IEEE MTT-S International Microwave Biomedical Conference (IMBioC) · doi:10.1109/imbioc60287.2024.10590577
“In addition, we support the findings by exposing the human anatomical model Ella of the Virtual Population (IT’IS Foun-2024 dation) [11] to an EV charging coil at 85 kHz, and relate the local E-field enhancement caused by a range of implants to the background enhancement, when the coil is driven at…”
MethodSelf-citationGallucci, S., Benini, M., Bonato, M., Galletta, V., Tognola, G., & Parazzini, M. (2024) · IEEE MTT-S International Microwave Biomedical Conference (IMBioC) · doi:10.1109/imbioc60287.2024.10590251
“More in details, as for the realistic models, the adult male and female models selected from the Virtual Population [5] were, respectively, Duke (aged 34, height 1.77 m, weight 70.3 kg, BMI 22.4 kg/m 3 ) and Ella (aged 26, height 1.63 m, weight 57.3 kg, BMI 21.5 kg/m 3 ).”
MethodInfluentialCompliance Evaluations of Inductive WPT Systems with Basic Restrictions by Computational Methods
Kuster, N., Xi, J., & Christ, A. (2024) · doi:10.23919/emcjapan/apemcokinaw58965.2024.10584984
“The level of conservativeness of such coverage factors may be reduced by restricting the analysis of the induced fields to anatomical models [8] of a specific population group, a limited set of exposed body regions, or particular coil designs.”
BackgroundSelf-citationExposure Assessment to Wearable 5G Antenna with Multi-Layer Skin in Realistic Human Models
Gallucci, S., Benini, M., Bonate, M., Galletta, V., Tognola, G., & Parazzini, M. (2024) · Digest - IEEE Antennas and Propagation Society. International Symposium · doi:10.1109/ap-s/inc-usnc-ursi52054.2024.10685862
“With more details, the adult male and female models from the Virtual Population [6] were chosen, Duke (age = 34 yo., height = 1.77 m, weight = 70.3 kg, BMI = 22.4 kg/m 3 ) and Ella (age = 26 yo., height = 1.63 m, weight = 57.3 kg, BMI = 21.5 kg/m 3 ), and their dielectric properties were set…”
MethodInfluentialVolumetric B 1 + Field Homogenization in 7 T Brain MRI Using Metasurface Scattering
Yoon, K., Yu, S., Lee, J., & Park, N. (2026) · ACS Photonics · doi:10.1021/acsphotonics.5c02781
Studying Bandwidths of Balancing Preamplifier Decoupling Networks
Jepsen, R. A., Ardenkjær‐Larsen, J. H., & Zhurbenko, V. (2024) · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition · doi:10.58530/2024/1592
Systems for power and data transfer
Qu, Y., Vilathgamuwa, D. M., McCormick, D., & McGiffin, D. C. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-22148-4.00022-8
Hernandez, D., Nam, T., Lee, E., Ryu, Y., Chung, J., & Kim, K. (2025) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.mp.2024-0086
Early-stage stomach cancer detection using ultrasound full-waveform inversion: a numerical study
Li, X., Cueto, C., Cudeiro-Blanco, J., Landless, J., Toulemonde, M. E. G., Bates, O., Hong, S. P., Shur, J. D., & Agudo, Ò. C. (2025) · SPIE Medical Imaging: Ultrasonic Imaging and Tomography · doi:10.1117/12.3044683
“[5] Two speed-of-sound maps were created using parameters from [6] and [7], as illustrated in Figure 1.”
Ullah, S., Oh, S., Cho, Y., & Yoo, H. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3545848
“6(b)–(d) shows simulated central transverse and sagittal slices of the B 1 field distributions produced by the birdcage coil within the liver phantom and in the liver of numerical human model (Duke, [41]).”
Lee, E., Nam, T., Hernandez, D., Ozhinsky, E., Narsinh, K. H., Sugrue, L. P., Han, Y., Kim, K. S., & Kim, K. (2025) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.70061
From Simulations to Clinical Practice: The Impact of 4D XCAT Phantoms on Imaging Technologies
-, F. J. A. (2025) · International Journal on Science and Technology · doi:10.71097/ijsat.v16.i2.4846
Computational Fluid Dynamics of Digestion Inside the Stomach
Kuhar, S., Seo, J.-H., Pasricha, P. J., & Mittal, R. (2025) · Lecture notes in mechanical engineering · doi:10.1007/978-981-97-7759-4_8
Plane wave absorption in realistic body models at mmWaves
Colella, M., Meo, S. D., Pasian, M., Liberti, M., & Apollonio, F. (2025) · IEEE Wireless Power Technology Conference and Expo (WPTCE) · doi:10.1109/wptce62521.2025.11062228
Li, W., Kuhar, S., Seo, J.-H., & Mittal, R. (2025) · Physics of Fluids · doi:10.1063/5.0278357
Breast MRI in the prone position: impact on RF-induced heating of active implantable medical devices
Yao, A., Goren, T., Lloyd, B., Fuss, C., Farcito, S., Wang, J. M., Yang, P., & Kuster, N. (2025) · Physics in Medicine and Biology · doi:10.1088/1361-6560/adf58d
“To numerically model both the standard and face-down MRI examination postures, the high-resolution anatomical model Ella from the virtual population (Gosselin 2014) was modified with breasts shaped typically of a prone patient during breast MRI, and posed and positioned in the following…”
Self-citationSchmid, G., Schneeweiss, P., Hirtl, R., Kainz, J., Sauter, C., Danker‐Hopfe, H., & Dorn, H. (2025) · Bioelectromagnetics · doi:10.1002/bem.70022
Esmaeili, H., Yang, C. F., & Schuster, C. (2025) · International Symposium on Electromagnetic Compatibility - EMC Europe (EMC Europe) · doi:10.1109/emceurope61644.2025.11176303
“The selection of appropriate computational anatomical models is crucial to achieving high-accuracy results in EM exposure assessments, and realistic models, such as [6], [7], have been developed to address different computational needs.”
Noninvasive Focused Ultrasound Spinal Cord Stimulation in Humans: A Computational Feasibility StudyPreprint
Isomura, K., Yu, W., & Gomez-Tames, J. D. (2025) · arXiv (Cornell University) · doi:10.48550/arxiv.2507.05702
First In Vivo 23 Na Human Imaging at 10.5 T Using a Combined Sodium‐Proton Transceiver Body Array
Schmidt, S., Ertürk, M. A., & Metzger, G. J. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70201
“To establish safe operating power limits, the virtual coil array was positioned over the kidneys in three distinct anatomical human body models [28, 29] (Duke, Ella, and Fats29).”
Li, M., Ewald, W., Waddington, D. E. J., Shan, S., Liu, P., Dong, B., Keall, P., Liu, F., & Crozier, . (2025) · arXiv (Cornell University) · doi:10.48550/arxiv.2511.22879
Yang, L., Ye, H., Kaula, N. F., Zheng, J., Long, S. A., & Chen, J. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11253788
“The Yoon-Sun anatomical human body model from the Virtual Population [9] was loaded at three imaging landmarks (head, cardiac, and abdominal) as shown in Figure 4.”
Static RF shimming for parallel-transmit at 7T using the particle-swarm algorithm
İpek, Ö., & Clément, J. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11251853
“To assess the validity of the SVD approach, individual transmit field maps were acquired on a homogeneous elliptical phantom (ε r = 79, σ = 0.95 S/m) with a pre -saturation turbo-flash sequence using an 8Tx dipole array (14,15,16), and compared to the measured individual transmit sensitivities obtained via SVD. Electr…”
InfluentialMfolozi, S. (2022) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.6477467
Approximation of Antemortem Axial Temperature Distribution for Death-time Estimation
Mfolozi, S. (2021) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.5760890
Tomographic Approach to Human Hydration Assessment: Proof of Concept
Besler, B. C. (2021) · doi:10.11575/prism/39206
Vermeeren, G., Depoortere, M., Plets, D., Joseph, W., & Martens, L. (2023) · Ghent University Academic Bibliography (Ghent University)
Human exposure to electromagnetic fields from 5G fixed wireless access points at 60 GHz
Vermeeren, G., Moreno Vivanco, E. A., Plets, D., Joseph, W., & Martens, L. (2022) · Ghent University Academic Bibliography (Ghent University)
Personalized Safety Modelling for Ultra-High Field MRI
de Buck, M. H. S. (. (2019) · Leiden Repository (Leiden University)
An Efficient Subgridding Method for SAR Calculation Based on the SBP-SAT Technique
Liu, H., Wu, W., & Yang, S. (2025) · IEEE International Symposium on Electromagnetic Compatibility · doi:10.1109/isemc68048.2025.11292306
Healthy lung and heart reference volumes and dosimetry phantoms from automatic CT segmentation
Kim, C. Y., & Park, J. S. (2025) · Medical Physics · doi:10.1002/mp.70247
A Review of AI-Powered Controls in the Field of Magnetic Resonance Imaging
Vinding, M. S., & Lund, T. E. (2026) · Computers · doi:10.3390/computers15010027
“Training data consisted of B + 1 field maps simulated in Sim4Life (ZMT Zurich MedTech AG, Zurich, Switzerland) for grids of translations and yaw rotations applied to numerical head models (Ella and Duke for training; Billie for validation/testing; Dizzy for testing) [111].”
Influence of MR thermometry on predicted temperature during regional hyperthermia treatment
Vydra, M., & Drizdal, T. (2026) · Acta Polytechnica · doi:10.14311/ap.2025.65.0705
“The other two models, the Duke model and the Ella models (See Figure 2), were obtained from the Sim4Life Virtual Population database [23, 24].”
Yang, L., Yang, X., Shen, A., Akter, M. K., Ye, H., Kaula, N. F., Zheng, J., & Chen, J. (2026) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70261
D’Agostino, S., Colella, M., Falsaperla, R., Liberti, M., & Apollonio, F. (2026) · Frontiers in Public Health · doi:10.3389/fpubh.2025.1705893
Kumar, S., Labastida‐Ramírez, A., Flaherty, S. M., Guimerà‐Brunet, A., de Eulate, N. A., Kostarelos, K., Dickie, B., Wykes, R. C., & Lemieux, L. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2602.03437
“…investigate the interaction of implants in the MRI environment by evaluating the effect on EM fields (i.e., B 1 - and E-fields), deposited RF energy (calculated as the specific absorption rate, SAR 1 ) in digital animal models (Ho 2001, Angelone et al 2004, Kainz et al 2006a, Gosselin et al 2014).”
In-Body Current Distribution Simulations to Set Voltage Withstand Requirements in Medical Devices
ゴメスタメス, ホ. (2025) · JAPANES JOURNAL OF MEDICAL INSTRUMENTATION · doi:10.4286/jjmi.95.654
Modeling strategies in non-invasive spinal stimulation: perspectives on state-of-the-art
Fernandes, S. R. (2026) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2026.1763470
“This is the most complete simulation pipeline available for tsDCS at the moment, however it will depend on availability of funds to obtain a user’s license (Gosselin et al., 2014).”
Influentialursachi, A. (2026) · Research Square · doi:10.21203/rs.3.rs-8935385/v1
Optimizing breast contour preserving possibilities in breast cancer surgery:Shaping the future
Heeling, E. (2025) · UvA-DARE (University of Amsterdam)
Rowald, A., Alashqar, A., Brihmat, N., Gemar, V., Hu, Z., Koh, S.-R., Diaz-Pier, S., de Freitas, R. M., Sasaki, A., Milosevic, M., et al. (2026) · Research Square · doi:10.21203/rs.3.rs-8693264/v1
Self-citationGallucci, S., Wydaeghe, R., Conforti, A., Stroobandt, B., Benini, M., Tognola, G., Wiart, J., Parazzini, M., & Joseph, W. (2025) · Ghent University Academic Bibliography (Ghent University)
He, C., Chen, C., Luo, Q., Li, Y., Cheng, Y., Chen, L., & Ruan, F. (2026) · Technologies · doi:10.3390/technologies14030190
Dong, X., Ren, Y., & Lu, M. (2026) · Archives of Electrical Engineering · doi:10.24425/aee.2026.158259
Immunité des implants cardiaques actifs aux champs électriques de 50/60 Hz
Gerçek, C. (2016) · theses.fr (ABES) · doi:10.70675/ecf9819azb23az4528zbce7zd8359ae2a39e
Lv, Z., Wu, Y., Zhao, K., Li, J., Gao, H., Zhao, X., Li, S., Xu, A., Li, J., Cai, Y., et al. (2026) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2026.120106
Millimeter-wave dosimetry accounting for antenna/body coupling
Ziane, M. (2022) · theses.fr (ABES) · doi:10.70675/7021f832z613dz4c53z9d40z680008deacb8
Developing the potential of 7 Tesla magnetic resonance imaging in neuropediatrics
Dudysheva, N. (2026) · theses.fr (ABES) · doi:10.70675/a455c38bzab00z4668zbae2z15b193ba690f
Guidetti, M., Annaloro, S., Gallucci, S., Parazzini, M., Chiaramello, E., Grado, A. D., Marceglia, S. R. F., Morelli, N., Bologna, M., Priori, A., et al. (2026) · Research Square · doi:10.21203/rs.3.rs-9029217/v1
Haluptzok, T. D., Sadeghi‐Tarakameh, A., Lagore, R., & Metzger, G. J. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.04.29.721770
“The feed of the dipoles was positioned over the center of the prostate, kidney, and heart of the Duke human body model 46,47 with distance-to-load ranging from 1 to 81mm in steps of 10mm.”
Hirata, A., & Sasaki, K. (2026) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ae6e89
“Subsequently, virtual populations were introduced to systematically incorporate variability in age, sex, and body morphology (Gosselin et al 2014).”
Risk analysis of lightning-caused body currents by modeling a human being using lumped elements
Beetz, D. (2026) · Electric Power Systems Research · doi:10.1016/j.epsr.2026.113327
Numerical Simulation-Based RF Safety Assessment Using Different Normalization Methods in 7T MRI
Eunwoo, L. E. E., Nam, T., Hernández, D., Kim, J., Kim, S. H., Yeji, H. A. N., & Kim, K. H. (2026) · Advanced Biomedical Engineering · doi:10.14326/abe.15.335
Exposure of the palm to handheld wireless devices operating at frequencies from 900 MHz to 6 GHz
Christ, A., NISKALA, K., & Joyner, K. H. (2026) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncag052
Advanced Female Body Model and Its Exposure to a 26 GHz Wearable Antenna
Colella, M., Dolciotti, N., Bellosono, L., D’Agostino, S., Apollonio, F., & Liberti, M. (2026) · IEEE Journal on Wireless Power Technologies · doi:10.1109/jwpt.2026.3701664
Lee, D.-M., Jung, Y.-J., Kim, I., Cho, K., Wang, Q., Oh, S., Kim, E.-S., & Kim, N. (2026) · Frontiers in Medical Technology · doi:10.3389/fmedt.2026.1768771
Yaneva, N. Y. (2026) · Frontiers in Immunology · doi:10.3389/fimmu.2026.1851942
“Rigorous dosimetric modelling will be performed using COMSOL Multiphysics fi nite-element analysis, employing a validated anatomical phantom of the anterior chest wall and medias-tinum derived from age-appropriate paediatric MRI data (21, 22).”
Evaluation of an open-face 8-channel transmit 64-channel receive 7T head coil for neuroimaging
Fullerton, N., Ding, B., Williams, S. N., Allwood‐Spiers, S., McElhinney, P., Baskaran, D., Woodward, R., Hopkins, T., McLennan, E., Winata, S., et al. (2026) · Frontiers in Neuroscience · doi:10.3389/fnins.2026.1811488
Design and Analysis of a Smart Watch Antenna Operating in the 2.4 GHz Band
Januszkiewicz, Ł., Danych, R., Łaski, M., & Bendzel, K. (2026) · Sensors · doi:10.3390/s26123921
“Although more anatomically detailed models, such as the Virtual Population models [22], are available in the literature, the adopted model was considered sufficient for the present antenna-design study because the region of interest was limited mainly to the wrist and forearm.”
InfluentialA Numerical Co-Simulation Framework for Interspecies Dual-Subject Preclinical RF Coil Design
Hernandez, D., Nam, T., Lee, D.-K., Jung, W. B., & Kim, K. (2026) · IEEE Access · doi:10.1109/access.2026.3706807
“Tissue segmentation was performed using a lookup table comparing the conductivity and permittivity of each tissue [35], [36], [37], [38].”
Hameed, S., Jiang, F., Bhusal, B., Ullah, S., Sanpitak, P., & Golestanirad, L. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2607.02816
“In Sim4Life, we evaluated voxel-based models from the Virtual Population 3.0 library, including Duke (standard adult male reference), Glenn (elderly male phenotype), Fats (obese male phenotype), Ella (standard adult female reference), and Ella BMI 30 (a high-BMI female model) [38].”
InfluentialAlbrecht, A., Ntolkeras, G., Zöllei, L., Sideris, G. A., Marturano, F., Lev, M. H., Grant, P. E., & Bonmassar, G. (2026) · NeuroImage · doi:10.1016/j.neuroimage.2026.122189
Perov, S. Y., & Kormilitsin, A. A. (2026) · Occupational Hygiene and Medical Ecology · doi:10.65491/3106-5538-2026-2-35-44
Kangasmaa, O., & Laakso, I. (2026) · Bioelectromagnetics · doi:10.1002/bem.70066
“Bioelectromagnetics , 2026 Potential sources include existing models, which include the peripheral nervous system (e.g., the male model by Zygote, American Fork, UT, USA, or the Yoon‐sun model from the Virtual Population Gosselin et al. (2014)), and detailed imaging datasets such as the Visible Human Project (U.S. Nat…”
Lee, E., Nam, T., Hernández, D., Kim, K., & Kim, K. (2026) · Medical Physics · doi:10.1002/mp.70631
“21 The water bolus properties ( ε r = 76.7, σ = 5 × 10 − 5 S/m) and zirconium transducer properties ( ε r = 1, σ = 2.436 × 10 6 S/m) were obtained from the Sim4Life material library and the IT’IS Foundation tissue properties database.”
InfluentialEnhancing Deep-Tissue Power Transfer Through Expandable Nitinol Antenna for Vascular Implants
Facchi, I., Yameen, N., Barreto, A. F. D. A., O’Sullivan, T. D., & Wetterling, F. (2026) · European Conference on Antennas and Propagation · doi:10.23919/eucap68105.2026.11611992
Design of a Flexible Antenna at 868 MHz for Relaying in-to-out Body Communication
Yang, Y., Vermeeren, G., & Joseph, W. (2026) · European Conference on Antennas and Propagation · doi:10.23919/eucap68105.2026.11612197
Evaluation of the additional occupational risk for workers with orthopedic implants in MRI settings
Zilberti, L., Arduino, A., Busoni, S., Camisa, V., Cannatà, V., Magistrelli, A., Miele, V., Oberhofer, N., Origgi, D., Pradella, S., et al. (2026) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxag067
“Two realistic human models belonging to the virtual population (Gosselin et al. 2014) are used: YoonSun (female, height: 1.52 m, weight: 54.6 kg, BMI: 23.6 kg m − 2 ) and Glenn (male, height: 1.73 m, weight: 61.1 kg, BMI: 20.4 kg m − 2 ).”
InfluentialLuo, M.-F., Xu, J.-J., Zhou, W.-Y., Li, X.-H., & Lu, M. (2026) · Frontiers in Public Health · doi:10.3389/fpubh.2026.1893518
Kumar, S., Labastida‐Ramírez, A., Flaherty, S., Guimerà‐Brunet, A., de Eulate, N. A., Kostarelos, K., Dickie, B., Wykes, R. C., & Lemieux, L. (2026) · Medical Sensors & Imaging · doi:10.1088/2977-8425/aea620
“…investigate the interaction of implants in the MRI environment by evaluating the effect on EM fields (i.e., B 1 - and E-fields), deposited RF energy (calculated as the specific absorption rate, SAR 1 ) in digital animal models (Ho 2001, Angelone et al 2004, Kainz et al 2006a, Gosselin et al 2014).”
Costa, G., Thielens, A., Jalilian, H., Huss, A., Röösli, M., & Paulides, M. M. (2026) · URSI General Assembly and Scientific Symposium · doi:10.46620/ursigass26/vxil7206
Bellosono, L., Colella, M., D’Agostino, S., Contessa, G. M., Polichetti, A., Liberti, M., & Apollonio, F. (2026) · URSI General Assembly and Scientific Symposium · doi:10.46620/ursigass26/mhxd5567
Orientation-Selective Temporal Interference for Non-Invasive Deep Brain Stimulation
Söderström, M., & Dalarsson, M. (2026) · URSI General Assembly and Scientific Symposium · doi:10.46620/ursigass26/nvaf9815
Dudysheva, N., Mauconduit, F., Luong, M., Amadon, A., Boulant, N., & Gras, V. (2026) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70569
Carlsson, M., Nicolausson, P., Söderström, M., & Dalarsson, M. (2026) · URSI General Assembly and Scientific Symposium · doi:10.46620/ursigass26/kkyl2345
Louka, A., Martinez, D. F., Zaraska, K. V., Wiens, C. N., Harris, C. T., Germann, J., Boutet, A., Kalia, S. K., Valiante, T. A., & Connell, I. R. O. (2026) · NeuroImage · doi:10.1016/j.neuroimage.2026.122244
Moser, M., Beyer, M., Müller‐Gerbl, M., Blache, S., Thieringer, F. M., & Mezey, S. E. (2026) · Anatomical Sciences Education · doi:10.1002/ase.70352
Electronic safety of portable electronic warfare operators: antenna subsystem requirements
Заболотный, П. И., & Kamkov, V. P. (2026) · Technical mechanics · doi:10.15407/itm2026.03.089
Perfusion-Related Plantar Temperature Changes in a Sim4Life Phantom: A Computational AnalysisPreprint
Farrugia, R., Falzon, O., & Mizzi, S. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7578554
GOLIAT: A configurable workflow for near- and far-field RF-EMF dosimetry in Sim4LifePreprint
Wydaeghe, R., Stroobandt, B., Vermeeren, G., Tanghe, E., Guxens, M., & Joseph, W. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7590236
Modelling Beat Pilot Tone Patterns in 3T MRI Scanner Loaded by Different Human Models
Kozlov, M., Pine, K., Möller, H. E., & Weiskopf, N. (2026) · International Conference on Electromagnetics in Advanced Applications (ICEAA) · doi:10.23919/iceaa69870.2026.11724822
“0 dataset [4], the VHP-model, and one patient-specific human (PSH) model [5, 6] created using a workflow that generates surface meshes from the patient-specific dataset.”
Yang, L., Shen, A., Akter, M. K., Kaula, N. F., Ye, H., Zheng, J., & Chen, J. (2026) · IEEE Access · doi:10.1109/access.2026.3748112
Šmondrk, M., Radil, R., Smetana, M., Janoušek, L., Bojda, P., & Skurčák, Ľ. (2026) · International Conference on Computational Problems of Electrical Engineering (CPEE) · doi:10.1109/cpee71962.2026.11768043
Schmid, G., Schneeweiss, P., & Hirtl, R. (2026) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aec01b
Metadata
- Authors
- Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., Cherubini, E., Szczerba, D., Kainz, W., & Kuster, N.
- Affiliations
- ETH Zurich (CH)
- Foundation for Research on Information Technologies in Society (CH)
- United States Food and Drug Administration (US)
- Corresponding author
- Gosselin, Marie-Christine
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-08-21
- Volume
- 59
- Issue
- 18
- Pages
- 5287-5303
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2102862641
- Cited by
- 520
- References
- 52
- Citations by year
- 2026: 34 · 2025: 64 · 2024: 44 · 2023: 50 · 2022: 61 · 2021: 52 · 2020: 53 · 2019: 45 · 2018: 42 · 2017: 35 · 2016: 20 · 2015: 14 · 2014: 3
- FWCI
- 12.45
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- European Commission (FP7/2007, 282891)
- Eidgenössische Technische Hochschule Zürich
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
- Keywords
- virtual population, MRI safety, spinal implants, surface processing, electromagnetic dosimetry, radiofrequency exposure, unstructured grid
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Child, Child, Preschool, Computer Simulation, Equipment and Supplies, Female, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Male, Middle Aged, Models, Anatomic, Models, Theoretical, Radiometry, Surface Properties, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.