Development of a new generation of high-resolution anatomical models for medical device evaluation: the Virtual Population 3.0
Open accessThe DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.
Abstract
The Virtual Family computational whole-body anatomical human models were originally developed for electromagnetic (EM) exposure evaluations, in particular to study how absorption of radiofrequency radiation from external sources depends on anatomy. However, the models immediately garnered much broader interest and are now applied by over 300 research groups, many from medical applications research fields. In a first step, the Virtual Family was expanded to the Virtual Population to provide considerably broader population coverage with the inclusion of models of both sexes ranging in age from 5 to 84 years old. Although these models have proven to be invaluable for EM dosimetry, it became evident that significantly enhanced models are needed for reliable effectiveness and safety evaluations of diagnostic and therapeutic applications, including medical implants safety. This paper describes the research and development performed to obtain anatomical models that meet the requirements necessary for medical implant safety assessment applications. These include implementation of quality control procedures, re-segmentation at higher resolution, more-consistent tissue assignments, enhanced surface processing and numerous anatomical refinements. Several tools were developed to enhance the functionality of the models, including discretization tools, posing tools to expand the posture space covered, and multiple morphing tools, e.g., to develop pathological models or variations of existing ones. A comprehensive tissue properties database was compiled to complement the library of models. The results are a set of anatomically independent, accurate, and detailed models with smooth, yet feature-rich and topologically conforming surfaces. The models are therefore suited for the creation of unstructured meshes, and the possible applications of the models are extended to a wider range of solvers and physics. The impact of these improvements is shown for the MRI exposure of an adult woman with an orthopedic spinal implant. Future developments include the functionalization of the models for specific physical and physiological modeling tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Each model is made up of over 300 tissues, with a supporting database of electromagnetic properties for each tissue.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The Virtual Population [30] is a set of human models for electromagnetic simulations that have been created for these purposes.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
The cited source says what the claim attributes to it.
In the citing paper
“MR-induced heating ISCTs using the virtual patients such as the Virtual Population [30] often focus validation efforts on the device model (e.g., clause 8.7.5 in ISO/TS 10974 [28]), rather than the patient model or coupled device-patient model.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“The assignment of the dielectric tissue properties at 64 MHz was done according to the material database (see section 2.2.4), which includes work presented in Gabriel et al (1996), and all metallic parts of the coil and the implant were treated as perfect electrical conductors.”
MethodInfluentialde Onís, M., Onyango, A. W., Borghi, E., Siyam, A., Pinol, A., Garza, C., Martines, J., Martorell, R., Victora, C. G., Bhan, M. K., et al. (2006) · (2006) · Cited by 3,401
Lanczos Filtering in One and Two Dimensions
Duchon, C. E. (1979) · Journal of Applied Meteorology · doi:10.1175/1520-0450(1979)018<1016:lfioat>2.0.co;2 · Cited by 2,398 · cited 3×
“It was tuned with lumped elements placed at the end rings between the rungs to match previously performed measurements (Cabot et al 2013). Due to the high resolution required by the implant and the large simulation domain required by the birdcage coil, the computation was performed in two steps: the fields in the bird…”
MethodInfluentialEfficient Management of Parallelism in Object-Oriented Numerical Software Libraries
Balay, S., Gropp, W. D., McInnes, L. C., & Smith, B. F. (1997) · Modern Software Tools for Scientific Computing · doi:10.1007/978-1-4612-1986-6_8 · Cited by 2,009 · cited 1×
“Dedicated high performance computing-enabled solvers, based on the PETSc framework (Balay et al 1997), have been developed for this purpose.”
MethodReport of the task group on reference man
(1979) · Annals of the ICRP · doi:10.1016/0146-6453(79)90123-4 · Cited by 1,706
Medical Image Computing and Computer-Assisted Intervention
Yang, G., Hawkes, D. J., Rueckert, D., Noble, J. A., & Taylor, C. (2009) · Research Explorer (The University of Manchester) · Cited by 1,591
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439 · cited 2×
“Pregnant women models at three gestational stages presented in Christ et al (2012) are included in the Virtual Population.”
BackgroundMethodSelf-citationComputerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Automatic three‐dimensional mesh generation by the finite octree technique
Shephard, M. S., & Georges, M. K. (1991) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.1620320406 · Cited by 732
amira: A Highly Interactive System for Visual Data Analysis
STALLING, D., WESTERHOFF, M., & HEGE, H.-C. (2005) · Visualization Handbook · doi:10.1016/b978-012387582-2/50040-x · Cited by 569 · cited 1×
“Also, the surface extraction and processing have been updated: previously, the surface extraction, simplification, and smoothing routines from the Amira software (Stalling et al 2005) were used.”
Method
Research works printed but not linked: 6
- Benkler S, Chavannes N and Kuster N 2009 New powerful FDTD source based on Huygens surface: highly complex EM simulations performed on an ordinary PC Abstract Collection of BioEM 2009 Davos: the Joint Meeting of the Bioelectromagnetics Society and the European BioElectromagnetics Association (Davos, Switzerland 14-19 June) (Poster presentation P-262 in Poster session 2: Theoretical and Practical Modeling (June 16)) pp 736-7
- Cherubini E, Chavannes N and Kuster N 2008 Realistic skeleton based deformation of high-resolution anatomical human models for electromagnetic simulation BEMS 2008: Abstracts of the 30th Annu. Meeting of the Bioelectromagnetics Society (San Diego, CA, USA, 9-12 June) pp 505-7 (Poster Presentation P-149 in Poster Session: Theoretical and Practical Modeling) (10 June))
- Cristy M 1980 Mathematical phantoms representing children of various ages for use in estimates of internal dose Oak Ridge National Laboratory Technical Report ORNL (Oak Ridge, TN: ORNL)
- Neufeld E, Szczerba D and Kuster N 2013b Mechanical simulation-based approach for realistic model shape and posture parametrization CP'13: 4th Int. Workshop on Computational Phantoms for Radiation Protection, Imaging and Radiotherapy (Zurich, 20-22 May) pp 14-5
- Sempé M, Pédron G and Roy-Pernot M-P 1979 Auxologie: méthode et séquences Théraplix (Paris: Theraplix)
- Spurway J F, 2004, ASUM Ultrasound Bull., 7, 15
Cited by
Items 201–300 of 601
A New Transmitting Coil for Powering Endoscopic Capsules Using Wireless Power Transfer
Campi, T., Cruciani, S., Maradei, F., & Feliziani, M. (2023) · Electronics · doi:10.3390/electronics12081942 · Cited by 10
Shikhantsov, S., Thielens, A., Vermeeren, G., Demeester, P. M. A., Martens, L., & Joseph, W. (2023) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2023.3273475 · Cited by 10
Dahdouh, S., Varsier, N., Ochoa, M. N., Wiart, J., Peyman, A., & Bloch, I. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/4/1500 · Cited by 10
Yao, A., Zastrow, E., Neufeld, E., & Kuster, N. (2019) · Bioelectromagnetics · doi:10.1002/bem.22208 · Cited by 10
“0 of the Virtual Population (ViP) [IT’IS, 2019] originally developed [Christ et al., 2010] and refined [Gosselin et al., 2014] by the IT’IS Foundation.”
Self-citationIn Silico Phase-Contrast X-Ray Imaging of Anthropomorphic Voxel-Based Phantoms
Häggmark, I., Shaker, K., & Hertz, H. M. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3031318 · Cited by 10
“, Virtual Population [19], XCAT [20]) are widely used for investigation of a large”
MethodInfluentialTuszyński, J. A., & Costa, F. P. (2022) · Frontiers in Medical Technology · doi:10.3389/fmedt.2022.869155 · Cited by 9
“Specific absorption rates were based on the “Duke” adult male model (weight 73 kg), one of ten models in the “Virtual Family” of whole-body anatomical models (73).”
MethodCompact Dual-Band On-Body Near Field Antenna With Reflector for Measuring Deep Core Temperature
Kim, I.-H., Lee, D.-M., Cho, M.-H., Lee, Y.-J., Han, J.-H., Shin, J., Lee, H.-Y., Kim, E., & Kim, N. (2023) · IEEE Access · doi:10.1109/access.2023.3262997 · Cited by 9
Egger, N., Nagelstraßer, S., Wildenberg, S., Bitz, A. K., Ruck, L., Herrler, J., Meixner, C. R., Kimmlingen, R., Lanz, T. E., Schmitter, S., et al. (2024) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30185 · Cited by 10
High-quality multimodal MRI with simultaneous EEG using conductive ink and polymer-thick film nets
Cicero, N. G., Fultz, N. E., Jeong, H., Williams, S. D., Gomez, D. E. P., Setzer, B., Warbrick, T., Jaschke, M., Gupta, R., Lev, M. H., et al. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad8837 · Cited by 9
“0) (Gosselin et al 2014) with EEG nets on the 3 T body transmit coil (diameter/length: 610/610 mm) with an RF shield.”
Thielens, A., Bockstael, A., Declerck, S., Aminzadeh, R., Aerts, S., Botteldooren, D. B., Martens, L., & Joseph, W. (2019) · Environmental Research · doi:10.1016/j.envres.2019.05.006 · Cited by 9
“Simulation setup using the Duke phantom (Gosselin et al., 2014) in two configurations: (a) and (b) show the ‘At Ear’ configuration from a right and front view, respectively, while (c) and (d) show the simulations used to model the ‘Speaker’ and ‘Headset’ exposure conditions for a right and front view respectively.”
MethodCampi, T., Cruciani, S., Maradei, F., Montalto, A., Musumeci, F., & Feliziani, M. (2021) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2021.3102036 · Cited by 9
“7 reproduces the real operation of the implanted pump [31], and was therefore adopted to measure”
MethodMarty, P., Boehm, C., Paverd, C., Rominger, M. B., & Fichtner, A. (2022) · SPIE Medical Imaging: Physics of Medical Imaging · doi:10.1117/12.2611548 · Cited by 9
“To demonstrate the effectiveness of the proposed hexahedral meshing strategy, a model of the human knee adapted from the Duke full-body phantom is considered.(30) Only the bones are utilized for this proof-of-concept such as to emphasize the interactions at the bone interfaces; soft tissues are not interpolated onto t…”
MethodOn the water–fat in‐phase assumption for quantitative susceptibility mapping
Boehm, C., Schlaeger, S., Meineke, J., Weiss, K., Makowski, M. R., & Karampinos, D. C. (2022) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29516 · Cited by 9
Dolciotti, N., Colella, M., D’Agostino, S., Apollonio, F., & Liberti, M. (2022) · European Microwave Conference (EuMC) · doi:10.23919/eumc54642.2022.9924391 · Cited by 9
“Other models are those of the Virtual Population (ViP) project [3], which includes models of male subjects (e.”
BackgroundMethodInfluentialComputational Models of the Fluid Mechanics of the Stomach
Kuhar, S., & Mittal, R. (2024) · Journal of the Indian Institute of Science · doi:10.1007/s41745-024-00421-z · Cited by 9
“…observations worth highlighting regarding the trend of stomach CFD models are, first, all anatomically realistic models use the virtual human population database 12 , and second, most models do not incorporate the opening/closing of the pylorus—leaving it either permanently open or closed 30 .”
Massey, J. W., Wei, F., Geyik, C. S., & Yılmaz, A. E. (2018) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2018.2835512 · Cited by 9
Bonato, M., Chiaramello, E., Fiocchi, S., Tognola, G., Ravazzani, P., & Parazzini, M. (2019) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2019.2958549 · Cited by 9
“model, both the models come from the Virtual Classroom family [30].”
MethodInterference of cardiovascular implantable electronic devices by static electric and magnetic fields
Jagielski, K., Kraus, T., & Stunder, D. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.1902802 · Cited by 9
“1 [13] was used which is well integrated into the Sim4Life platform and supports customized meshing.”
MethodElectric Field Distribution Induced by TMS: Differences Due to Anatomical Variation
Tzirini, M., Chatzikyriakou, E., Κούσκουρας, Κ., Foroglou, N., Samaras, T., & Kimiskidis, V. Κ. (2022) · Applied Sciences · doi:10.3390/app12094509 · Cited by 9
“As far as the head model anatomical complexity is concerned, the EF can be computed in anything in the range from homogenous spheres [27,28] to high-resolution, anatomically realistic head models [29].”
BackgroundMethodBenini, M., Parazzini, M., Bonato, M., Gallucci, S., Chiaramello, E., Fiocchi, S., & Tognola, G. (2023) · Sensors · doi:10.3390/s23115170 · Cited by 9
Wegert, L., Ziółkowski, M., Kalla, T., Lange, I., Haueisen, J., & Hunold, A. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad8c84 · Cited by 8
“The neck volume conductor model at the macroscale had a higher level of anatomical detail and modularity because of the single tissue compartments, compared to state-of-the-art neck models (Gosselin et al 2014, Makarov et al 2017, Noetscher et al 2021, de Freitas et al 2022).”
A dedicated eight‐channel receive RF coil array for monkey brain MRI at 9.4 T
Li, M., Li, Y., Jin, J., Yang, Z., Zhang, B., Liu, Y., Song, M., Freakly, C., Ewald, W., Liu, F., et al. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4369 · Cited by 8
Learning to ground medical text in a 3D human atlas
Grujicic, D., Radevski, G., Tuytelaars, T., & Blaschko, M. B. (2020) · Conference on Computational Natural Language Learning · doi:10.18653/v1/2020.conll-1.23 · Cited by 8
Poni, R., Neufeld, E., Capstick, M. H., Bodis, S. B., & Kuster, N. (2022) · International Journal of Hyperthermia · doi:10.1080/02656736.2022.2080284 · Cited by 8
“The setup comprises a detailed anatomical model from the Virtual Population (ViP) [17].”
MethodSelf-citationSAR calculations for titanium bar-implant subjected to microwave radiation
Miaskowski, A., Gas, P., & Krawczyk, A. (2016) · International Conference on Computational Problems of Electrical Engineering (CPEE) · doi:10.1109/cpee.2016.7738726 · Cited by 8
Shikhantsov, S., Thielens, A., Vermeeren, G., Demeester, P. M. A., Martens, L., Torfs, G., & Joseph, W. (2018) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncy120 · Cited by 8
“1 posable heterogeneous Duke phantom((8)), which represents an average adult male human (height = 1.”
BackgroundExcitation and RF Field Control of a Human-Size 10.5-T MRI System
Bluem, P., de Moortele, P. V., Adriany, G., & Popovic, Z. B. (2018) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2018.2884405 · Cited by 8
Bakogianni, S., & Koulouridis, S. (2015) · European Conference on Antennas and Propagation · Cited by 8
Covering Population Variability: Morphing of Computation Anatomical Models
Lloyd, B., Cherubini, E., Farcito, S., Neufeld, E., Baumgärtner, C., & Kuster, N. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-46630-9_2 · Cited by 8
“High quality surface meshes enclosing each of the more than 300 tissues and organs were generated from the segmented label fields [11].”
BackgroundMethodSelf-citationNumerical Basics of Bioimpedance Measurements
Danilov, A. A., Rudnev, S. G., & Vassilevski, Y. V. (2018) · Springer eBooks · doi:10.1007/978-3-319-74388-2_8 · Cited by 8
“Computerized models of real human anatomy and digital human phantoms are extensively used in various areas of biomedicine such as radiography, nuclear medicine and radiation protection (Caon 2004; Xu 2014), as well as for educational and other purposes (Gosselin et al. 2014; Saltarelli et al. 2014).”
BackgroundYanamadala, J., Borwankar, R. M., Makarov, S. N., & Pascual‐Leone, Á. (2019) · Springer eBooks · doi:10.1007/978-3-030-21293-3_3 · Cited by 8
Akter, M. K., Shen, A., Islam, M. Z., Zhang, L., Zheng, J., & Chen, J. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70024 · Cited by 7
Gökyar, S., Voss, H. U., Taracila, V., Robb, F. J. L., Bernico, M., Kelley, D. A. C., Ballon, D., & Winkler, S. A. (2022) · NMR in Biomedicine · doi:10.1002/nbm.4802 · Cited by 7
Destruel, A., Mauconduit, F., Massire, A., Abdeddaïm, R., Guye, M., Gras, V., & Callot, V. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29708 · Cited by 7
Kim, C. Y., Chung, M. S., & Park, J. S. (2024) · Surgical and Radiologic Anatomy · doi:10.1007/s00276-024-03381-2 · Cited by 8
“The IT’IS foundation has already developed and released a Virtual Family [2] and its next generation, Virtual Population [14] consisting of males, females, and children, which are the most famous computational phantoms for electromagnetic radiation (EMR) fields worldwide.”
Chinese Digital Arm (CDA): A High-Precision Digital Arm for Electrical Stimulation Simulation
Zhang, S., Wang, J., Yu, Y., Wu, L., & Zhang, T. (2023) · Bioengineering · doi:10.3390/bioengineering10030374 · Cited by 7
“The digital human plan developed by the Swiss IT’IS Found [22,23] provided a complete human dataset with an organ segmentation scheme.”
MethodHu, W., Guo, R., Wang, Q., Zheng, J., Tsang, J., Kainz, W., Long, S. A., & Chen, J. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29650 · Cited by 7
Self-citationYao, A., Li, Z., & Ma, M. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad2714 · Cited by 7
Yang, L., Yang, X., Ye, H., Kaula, N. F., Jin, Y., Zheng, J., Kainz, W., & Chen, J. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30470 · Cited by 7
“12,13 14–17 With the development of high-resolution anatomical human body models, 18,19 it is possible to conduct more accurate electromagnetic (EM) simulations to obtain clinically relevant electric field distributions along realistic nerve fibers.”
Self-citationMagnetic Resonance-Based Electric Properties Tomography via Green’s Integral Identity
Zilberti, L., Arduino, A., Zanovello, U., Martinez, J., Moulin, K., Troia, A., & Bottauscio, O. (2025) · IEEE Access · doi:10.1109/access.2025.3546036 · Cited by 7
“The Duke model of the Virtual Population [30] was positioned inside a two-channel, 16-leg high-pass shielded birdcage body coil (diameter: 713 mm, height: 450 mm) tuned at 128 MHz.”
A purpose-built neck coil for black-blood DANTE-prepared carotid artery imaging at 7 T
Papoutsis, K., Li, L., Near, J., Payne, S. J., & Jezzard, P. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2017.04.011 · Cited by 7
Destruel, A., Fuentes, M., Ewald, W., O’Brien, K., Jin, J., Liu, F., Barth, M., & Crozier, . (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27688 · Cited by 7
Kozlov, M., Kalloch, B., Horner, M., Bazin, P., Weiskopf, N., & Möller, H. E. (2019) · Springer eBooks · doi:10.1007/978-3-030-21293-3_13 · Cited by 7
Meliadò, E. F., Sbrizzi, A., van den Berg, C. A. T., Luijten, P. R., & Raaijmakers, A. J. E. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28635 · Cited by 7
On the Optimal Matching Medium and the Working Frequency in Deep Pelvic Hyperthermia
Bellizzi, G. G., Sümser, K., & Bevacqua, M. T. (2020) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2020.3047980 · Cited by 7
Bottauscio, O., Rubia‐Rodríguez, I., Arduino, A., Zilberti, L., Chiampi, M., & Ortega, D. (2022) · International Journal of Hyperthermia · doi:10.1080/02656736.2022.2121863 · Cited by 7
“The human model used for the simulations was Duke from IT’IS Foundation virtual family [14,15].”
MethodProof-of-Concept of Microwave-Based Bladder State Detection Using Realistic Pelvic Models
Farshkaran, A., Fry, A., Raterink, A., Santorelli, A., & Porter, E. (2023) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2023.3305838 · Cited by 8
Universal modes: Calibration‐free time‐interleaved acquisition of modes
Schmidt, S., He, X., & Metzger, G. J. (2024) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30032 · Cited by 7
Xie, T., Kuster, N., & Zaidi, H. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa75b4 · Cited by 7
Self-citationErtürk, M. A., Panken, E., Conroy, M. J., Edmonson, J., Kramer, J., Chatterton, J., & Banerjee, S. R. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.00034 · Cited by 7
“, virtual population (Gosselin et al., 2014)] are simulated (Zhao et al.”
MethodInfluentialDiao, Y., Rashed, E. A., & Hirata, A. (2020) · IEEE Access · doi:10.1109/access.2020.3017773 · Cited by 7
“Commonly used models include the TARO and HANOKO models developed by NICT, Japan [17], Virtual population models developed by IT’IS foundation, Swiss [18], NORMAN [19], and NAOMI [20] developed by the NRPB, UK.”
MethodHernandez, D., Han, Y., Son, S., & Kim, K. (2021) · Journal of Electromagnetic Waves and Applications · doi:10.1080/09205071.2021.1871779 · Cited by 7
“(sim4life) [56,57], is composed of over 120 tissues and segmented organs, allowing us to study the spinal cord in detail.”
BackgroundPosture-Transformed Monkey Phantoms Developed from a Visible Monkey
Kim, C. Y., Lee, A., Choi, H., & Park, J. S. (2021) · Applied Sciences · doi:10.3390/app11104430 · Cited by 7
Dolciotti, N., Colella, M., D’Agostino, S., Apollonio, F., & Liberti, M. (2022) · IEEE Mediterranean Electrotechnical Conference (MELECON) · doi:10.1109/melecon53508.2022.9843025 · Cited by 7
Modeling Endovascular MRI Coil Coupling With Transmit RF Excitation
Venkateswaran, M., Ünal, O., Hurley, S. A., Samsonov, A. A., Wang, P., Fain, S. B., & Kurpad, K. N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2538279 · Cited by 7
“For instance, we can replace the homogeneous phantom model with an exact model for a particular organ [35].”
Cabello, M. R., Abaļenkovs, M., Angulo, L. D., Sánchez, C. C., Moglie, F., & García, S. G. (2020) · PLoS ONE · doi:10.1371/journal.pone.0238115 · Cited by 7
“The CAD data has been provided by IT’IS from the virtual family [20] (codenamed as Ella v2.”
MethodJacobs, S., Prompers, J. J., van der Kemp, W. J. M., van der Velden, T. A., Gosselink, M. W. J. M., Meliadò, E. F., Hoogduin, H. M., Mason, G. F., de Graaf, R. A., Miller, C. O., et al. (2024) · NMR in Biomedicine · doi:10.1002/nbm.5195 · Cited by 6
Electromagnetic compatibility study of trackside antenna array miniaturization in the subway tunnel
Zhou, W.-Y., Xu, J.-J., Lu, M., & Li, Y. (2024) · Physica Scripta · doi:10.1088/1402-4896/ad8b74 · Cited by 6
Jung, K., Meerbothe, T. G., Cui, C., Park, M., van den Berg, C. A. T., Mandija, S., & Kim, D. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121054 · Cited by 6
“These data consisted of electromagnetic fields simulated in Sim4Life (Zurich Med Tech, Zurich Switzerland) at 128MHz (Christ et al., 2009; Gosselin et al., 2014).”
On the RF safety of titanium mesh head implants in 7 T MRI systems: an investigation
Mustafa, M. M., Zulkarnain, N. I. H., Sadeghi‐Tarakameh, A., Grant, A., Darrow, D., Özütemiz, C., & Eryaman, Y. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30477 · Cited by 6
“34,35 Those models are shown in Figure 1D,H inside the head coil Tx model with a titanium mesh implant.”
Open‐Source Simulator of Imaging Near Metal at Arbitrary Magnetic Field Strengths
Keskin, K., Sanson, A. R., Hargreaves, B. A., & Nayak, K. S. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70163 · Cited by 6
Human Body Exposure to a Vehicular Antenna: a Numerical Study in a Realistic Military Scenario
Colella, M., Biscarini, M., de Meis, M., Patrizi, R., Ciallella, T., Cavagnaro, M., Apollonio, F., & Liberti, M. (2022) · Mediterranean Microwave Symposium · doi:10.1109/mms55062.2022.9825581 · Cited by 6
Berangi, M., Kuehne, A., Waiczies, H., & Niendorf, T. (2023) · Tomography · doi:10.3390/tomography9020049 · Cited by 6
“The eight-loop–dipole configuration (H) was selected for the simulation of a realistic human model (Duke [54]) with a sample screw (L = 70 mm, outer diameter Dout = 1 mm) implanted in the right tibia.”
MethodThe coax monopole antenna: A flexible end‐fed antenna for ultrahigh field transmit/receive arrays
Budé, L. M. I., Steensma, B. R., Zivkovic, I., & Raaijmakers, A. J. E. (2024) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30036 · Cited by 6
Kozlov, M., Bode, J., Bazin, P., Kalloch, B., Weiskopf, N., & Möller, H. E. (2017) · IEEE International Conference on Microwaves, Communications, Antennas and Electronic Systems (COMCAS) · doi:10.1109/comcas.2017.8244808 · Cited by 6
Fagan, A. J., Jacobs, P. S., Hulshizer, T. C., Rossman, P. J., Frick, M. A., Amrami, K. K., & Felmlee, J. P. (2020) · Medical Physics · doi:10.1002/mp.14641 · Cited by 6
Paepe, S. D., Borre, E. D., Toribio, D., Bell, D., & Thielens, A. (2022) · International Journal of Radiation Biology · doi:10.1080/09553002.2022.2113838 · Cited by 6
Spronk, T., Kraff, O., Schaefers, G., & Quick, H. H. (2023) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-023-01074-2 · Cited by 6
“Exemplarily, the human model “Duke” (a 34-year-old male) from IT’IS foundation [15] was imported to the simulation with the tissue parameters provided in Table 1.”
MethodFast and Reliable Human Exposure Assessment Around High Power Systems Using Surrogate Modeling
Lagouanelle, P., Freschi, F., Pichon, L., & Giaccone, L. (2024) · IEEE Access · doi:10.1109/access.2024.3366654 · Cited by 6
“This computation can be made by any solver: a specific Boundary Element Method solver for the WPT case [14] or a classical FDTD Low-Frequency solver using the Sim4Life software from SPEAG [4] for the MFDC spot welding gun case.”
MethodNeufeld, E., Oikonomidis, I. V., Iacono, M. I., Akinnagbe, E., Angelone, L. M., Kainz, W., & Kuster, N. (2015) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2015.7146673 · Cited by 6
Self-citationSuitability of eigenvalue beam‐forming for discrete multi‐frequency hyperthermia treatment planning
Zanoli, M., & Trefná, H. D. (2021) · Medical Physics · doi:10.1002/mp.15220 · Cited by 6
Asymmetrical Planar Folded Dipole Antennas for Human Body MRI at 7 T
Chen, H., Guo, L., Lou, F., Gao, Y., Quan, Z., Liu, C., Boulant, N., Liu, F., & Zhang, X. (2024) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2024.3513639 · Cited by 5
“An eight-channel APFD coil array and a corresponding eight-channel FD array were positioned around the kidneys on a realistic human body model provided by the IT’IS Foundation [27], [28].”
Li, W., Kuhar, S., Seo, J.-H., & Mittal, R. (2025) · Journal of Biomechanical Engineering · doi:10.1115/1.4068373 · Cited by 5
“This stomach model was segmented from the Virtual Population Library (VPL) [16] for an adult male ("Duke").”
InfluentialFetal MRI : Radiofrequency Safety Assessment at 3 Tesla
Yetişir, F., Türk, E. A., Feldman, H. A., Gagoski, B. A., Didier, R. A., Barnewolt, C. E., Estroff, J. A., Wald, L. L., Adalsteinsson, E., & Grant, P. E. (2025) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.29797 · Cited by 5
Zhou, W.-Y., Li, Y.-X., Li, W., Lu, M., & Xu, J.-J. (2025) · PLoS ONE · doi:10.1371/journal.pone.0323299 · Cited by 5
Assessment of Electromagnetic Exposure Levels for Humans from Electric Vehicle DC Charging Stations
Dong, S., & Lu, M. (2025) · Sensors · doi:10.3390/s25185735 · Cited by 5
“Duke has a standing height of 1.77 m, while Thelonious has a standing height of 1.15 m [40].”
InfluentialCuffless hemodynamic monitoring with physics-informed machine learning models
Crandall, H., Schuessler, T., Bělík, F., Fabregas, A., Stults, B. M., Boyadzhiev, A. M., Zhang, H., Wu, J. S., Rodan, A. R., Juraschek, S. P., et al. (2026) · Nature Communications · doi:10.1038/s41467-026-72693-1 · Cited by 5
“16 – 19).”
InfluentialRF Exposure Assessment for Various Poses of Patient Assistant in Open MRI Environment
Hong, S., Oh, S., & Choi, H. (2021) · Applied Sciences · doi:10.3390/app11114967 · Cited by 5
Lê, T. P., Gruetter, R., Jorge, J., & İpek, Ö. (2022) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29298 · Cited by 5
“The imaging object was either the realistic human model Duke 3.0 from the virtual family 25 or a digitized version of the agar-gel phantom to match the MR measurements.”
MethodInfluentialColella, M., Meo, S. D., Marracino, P., Liberti, M., Pasian, M., & Apollonio, F. (2022) · European Microwave Conference (EuMC) · doi:10.23919/eumc50147.2022.9784198 · Cited by 5
Jeong, H., Andersson, J., Hess, A. T., & Jezzard, P. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29589 · Cited by 5
Akter, M. K., Guo, R., Islam, M. Z., Zheng, J., Kainz, W., Long, S. A., & Chen, J. (2024) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2024.3403508 · Cited by 5
Self-citationEnhancing Female Breast Modelling: Advanced Strategies in the Case Study of a Plane Wave Exposure
Dolciotti, N., Colella, M., D’Agostino, S., Apollonio, F., & Liberti, M. (2024) · IEEE MTT-S International Microwave Biomedical Conference (IMBioC) · doi:10.1109/imbioc60287.2024.10590407 · Cited by 5
“…from simplified objects, virtual human body models have been progressively developed over the years to use in a wide range of applications [4], [5], both to obtain representations of an increasingly broad population and to have models that are ever more detailed and anatomically accurate [6], [7].”
BackgroundMethodInfluentialYang, Y., Masini, B. M., Vermeeren, G., van den Akker, D., Aerts, S., Verloock, L., Chiaramello, E., Bonato, M., Wiart, J., Tognola, G., et al. (2024) · IEEE Access · doi:10.1109/access.2024.3435566 · Cited by 5
“The adult and child human models used the ViP v.3.0 Duke [38] and ViP v.1.0 Billie models [39] respectively, with the dielectric properties ( ε r and σ ) of different tissues at the frequencies of each transmitting antenna were assigned according to [41], and each human model was meshed with a step…”
InfluentialZilberti, L., Curreli, C., Arduino, A., Zanovello, U., Baruffaldi, F., & Bottauscio, O. (2024) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30263 · Cited by 5
“In order to move these implants along realistic trajectories, they were placed in the left leg of the Glenn body model, 29 following a “virtual surgery” procedure.”
Exposure to 5G mmWaves of a Base Station Operator: Dosimetric Study of the Influence of Posture
Bellosono, L., D’Agostino, S., Colella, M., Contessa, G. M., Polichetti, A., Liberti, M., & Apollonio, F. (2024) · International Symposium on Electromagnetic Compatibility - EMC Europe (EMC Europe) · doi:10.1109/emceurope59828.2024.10722266 · Cited by 5
“D anatomical model used for this study is the Virtual Population human male model Duke (ViP, v. 3.1) [17].”
MethodInfluentialEvaluation of SAR induced by a Planar Inverted-F Antenna based on a Realistic Human Model
Vieira, V. F., Pessoa, L. M., & Carvalho, M. I. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-5122-7_150 · Cited by 5
Babich, M. V., & Kublanov, V. (2019) · Ural Symposium on Biomedical Engineering, Radioelectronics and Information Technology (USBEREIT) · doi:10.1109/usbereit.2019.8736569 · Cited by 5
Park, J. S. (2019) · Health Physics · doi:10.1097/hp.0000000000001186 · Cited by 5
Fiocchi, S., Chiaramello, E., Priori, A., Ravazzani, P., & Parazzini, M. (2020) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2020.2967595 · Cited by 5
“Six computational whole-body anatomical human models, of the “Virtual Population” [27], [28] were used (see details in Table I).”
MethodShang, Y., Theilenberg, S., Terekhov, M., Mattar, W., Peng, B., Jambawalikar, S., Schreiber, W., & Juchem, C. (2022) · NMR in Biomedicine · doi:10.1002/nbm.4739 · Cited by 5
In silico study of the dynamics of solid food particles in the stomach during gastric digestion
Kuhar, S., Seo, J.-H., & Mittal, R. (2025) · Journal of The Royal Society Interface · doi:10.1098/rsif.2025.0291 · Cited by 4
“Similar to our previous study [23], the stomach anatomy used in the current work was generated by modifying publicly available imaging data—Virtual Population Library (VPL) [35].”
Syrek, P., & Skowron, M. (2025) · Applied Sciences · doi:10.3390/app16010107 · Cited by 4
Jeong, H., Guag, J. W., & Kumar, A. (2024) · IEEE Access · doi:10.1109/access.2024.3518974 · Cited by 4
“We utilized the Duke human model (34-year-old male) [15] at nine different imaging positions (or landmarks); position z = 0 corresponds to a location inside the model’s head at the eyebrow level centered in QBC, then moved every 200 mm distance to 1600 mm towards the feet.”
Quantifying the Effect of Body Habitus on Cardiac Auscultation Via Computational Hemoacoustics
Lee, D., Seo, J.-H., & Mittal, R. (2022) · Journal of Biomechanical Engineering · doi:10.1115/1.4055513 · Cited by 4
Esmaeili, H., Yang, C. F., & Schuster, C. (2022) · International Symposium on Electromagnetic Compatibility - EMC Europe (EMC Europe) · doi:10.1109/emceurope51680.2022.9900973 · Cited by 4
Fall, A. K., Guraliuc, A. R., Monfret, N., & Setzu, R. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29583 · Cited by 4
Semi-automatic Framework for Voxel Human Deformation Modeling
Gao, Y., Xu, X., Li, C., Liu, J., & Wu, T. (2023) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/1573405620666230613103727 · Cited by 4
Terekhov, M., Elabyad, I. A., Lohr, D., Reiter, T., Kögler, C., Lanz, T. E., & Schreiber, W. (2023) · NMR in Biomedicine · doi:10.1002/nbm.5023 · Cited by 4
“31 For the reference simulations, the arrays were positioned such that the centers of both anterior and posterior arrays were located on the body's vertical axes and matched the center of the heart in the head-foot direction.”
MethodOptimal Frequency and Wireless Power Budget for Miniature Receivers in Obese People
de Steene, T. V., Tanghe, E., Martens, L., Garripoli, C., Stanzione, S., & Joseph, W. (2023) · Sensors · doi:10.3390/s23198084 · Cited by 4
“2 software [61], using a model of the coil and the adult Duke body model from the Virtual Population [53], as shown in Figure 9.”
Method
Metadata
- Authors
- Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., Cherubini, E., Szczerba, D., Kainz, W., & Kuster, N.
- Affiliations
- ETH Zurich (CH)
- Foundation for Research on Information Technologies in Society (CH)
- United States Food and Drug Administration (US)
- Corresponding author
- Gosselin, Marie-Christine
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-08-21
- Volume
- 59
- Issue
- 18
- Pages
- 5287-5303
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2102862641
- Cited by
- 520
- References
- 52
- Citations by year
- 2026: 34 · 2025: 64 · 2024: 44 · 2023: 50 · 2022: 61 · 2021: 52 · 2020: 53 · 2019: 45 · 2018: 42 · 2017: 35 · 2016: 20 · 2015: 14 · 2014: 3
- FWCI
- 12.45
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- European Commission (FP7/2007, 282891)
- Eidgenössische Technische Hochschule Zürich
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
- Keywords
- virtual population, MRI safety, spinal implants, surface processing, electromagnetic dosimetry, radiofrequency exposure, unstructured grid
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Child, Child, Preschool, Computer Simulation, Equipment and Supplies, Female, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Male, Middle Aged, Models, Anatomic, Models, Theoretical, Radiometry, Surface Properties, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.