Development of a new generation of high-resolution anatomical models for medical device evaluation: the Virtual Population 3.0
Open accessThe DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.
Abstract
The Virtual Family computational whole-body anatomical human models were originally developed for electromagnetic (EM) exposure evaluations, in particular to study how absorption of radiofrequency radiation from external sources depends on anatomy. However, the models immediately garnered much broader interest and are now applied by over 300 research groups, many from medical applications research fields. In a first step, the Virtual Family was expanded to the Virtual Population to provide considerably broader population coverage with the inclusion of models of both sexes ranging in age from 5 to 84 years old. Although these models have proven to be invaluable for EM dosimetry, it became evident that significantly enhanced models are needed for reliable effectiveness and safety evaluations of diagnostic and therapeutic applications, including medical implants safety. This paper describes the research and development performed to obtain anatomical models that meet the requirements necessary for medical implant safety assessment applications. These include implementation of quality control procedures, re-segmentation at higher resolution, more-consistent tissue assignments, enhanced surface processing and numerous anatomical refinements. Several tools were developed to enhance the functionality of the models, including discretization tools, posing tools to expand the posture space covered, and multiple morphing tools, e.g., to develop pathological models or variations of existing ones. A comprehensive tissue properties database was compiled to complement the library of models. The results are a set of anatomically independent, accurate, and detailed models with smooth, yet feature-rich and topologically conforming surfaces. The models are therefore suited for the creation of unstructured meshes, and the possible applications of the models are extended to a wider range of solvers and physics. The impact of these improvements is shown for the MRI exposure of an adult woman with an orthopedic spinal implant. Future developments include the functionalization of the models for specific physical and physiological modeling tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Each model is made up of over 300 tissues, with a supporting database of electromagnetic properties for each tissue.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The Virtual Population [30] is a set of human models for electromagnetic simulations that have been created for these purposes.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
The cited source says what the claim attributes to it.
In the citing paper
“MR-induced heating ISCTs using the virtual patients such as the Virtual Population [30] often focus validation efforts on the device model (e.g., clause 8.7.5 in ISO/TS 10974 [28]), rather than the patient model or coupled device-patient model.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“The assignment of the dielectric tissue properties at 64 MHz was done according to the material database (see section 2.2.4), which includes work presented in Gabriel et al (1996), and all metallic parts of the coil and the implant were treated as perfect electrical conductors.”
MethodInfluentialde Onís, M., Onyango, A. W., Borghi, E., Siyam, A., Pinol, A., Garza, C., Martines, J., Martorell, R., Victora, C. G., Bhan, M. K., et al. (2006) · (2006) · Cited by 3,401
Lanczos Filtering in One and Two Dimensions
Duchon, C. E. (1979) · Journal of Applied Meteorology · doi:10.1175/1520-0450(1979)018<1016:lfioat>2.0.co;2 · Cited by 2,398 · cited 3×
“It was tuned with lumped elements placed at the end rings between the rungs to match previously performed measurements (Cabot et al 2013). Due to the high resolution required by the implant and the large simulation domain required by the birdcage coil, the computation was performed in two steps: the fields in the bird…”
MethodInfluentialEfficient Management of Parallelism in Object-Oriented Numerical Software Libraries
Balay, S., Gropp, W. D., McInnes, L. C., & Smith, B. F. (1997) · Modern Software Tools for Scientific Computing · doi:10.1007/978-1-4612-1986-6_8 · Cited by 2,009 · cited 1×
“Dedicated high performance computing-enabled solvers, based on the PETSc framework (Balay et al 1997), have been developed for this purpose.”
MethodReport of the task group on reference man
(1979) · Annals of the ICRP · doi:10.1016/0146-6453(79)90123-4 · Cited by 1,706
Medical Image Computing and Computer-Assisted Intervention
Yang, G., Hawkes, D. J., Rueckert, D., Noble, J. A., & Taylor, C. (2009) · Research Explorer (The University of Manchester) · Cited by 1,591
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439 · cited 2×
“Pregnant women models at three gestational stages presented in Christ et al (2012) are included in the Virtual Population.”
BackgroundMethodSelf-citationComputerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Automatic three‐dimensional mesh generation by the finite octree technique
Shephard, M. S., & Georges, M. K. (1991) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.1620320406 · Cited by 732
amira: A Highly Interactive System for Visual Data Analysis
STALLING, D., WESTERHOFF, M., & HEGE, H.-C. (2005) · Visualization Handbook · doi:10.1016/b978-012387582-2/50040-x · Cited by 569 · cited 1×
“Also, the surface extraction and processing have been updated: previously, the surface extraction, simplification, and smoothing routines from the Amira software (Stalling et al 2005) were used.”
Method
Research works printed but not linked: 6
- Benkler S, Chavannes N and Kuster N 2009 New powerful FDTD source based on Huygens surface: highly complex EM simulations performed on an ordinary PC Abstract Collection of BioEM 2009 Davos: the Joint Meeting of the Bioelectromagnetics Society and the European BioElectromagnetics Association (Davos, Switzerland 14-19 June) (Poster presentation P-262 in Poster session 2: Theoretical and Practical Modeling (June 16)) pp 736-7
- Cherubini E, Chavannes N and Kuster N 2008 Realistic skeleton based deformation of high-resolution anatomical human models for electromagnetic simulation BEMS 2008: Abstracts of the 30th Annu. Meeting of the Bioelectromagnetics Society (San Diego, CA, USA, 9-12 June) pp 505-7 (Poster Presentation P-149 in Poster Session: Theoretical and Practical Modeling) (10 June))
- Cristy M 1980 Mathematical phantoms representing children of various ages for use in estimates of internal dose Oak Ridge National Laboratory Technical Report ORNL (Oak Ridge, TN: ORNL)
- Neufeld E, Szczerba D and Kuster N 2013b Mechanical simulation-based approach for realistic model shape and posture parametrization CP'13: 4th Int. Workshop on Computational Phantoms for Radiation Protection, Imaging and Radiotherapy (Zurich, 20-22 May) pp 14-5
- Sempé M, Pédron G and Roy-Pernot M-P 1979 Auxologie: méthode et séquences Théraplix (Paris: Theraplix)
- Spurway J F, 2004, ASUM Ultrasound Bull., 7, 15
Cited by
Items 401–500 of 601
Kodama, M., & Muramatsu, D. (2025) · AIP Advances · doi:10.1063/5.0242285 · Cited by 1
Zradziński, P., Karpowicz, J., & Gryz, K. (2025) · Applied Sciences · doi:10.3390/app15126602 · Cited by 1
Karatsi, I., Bakogianni, S., & Koulouridis, S. (2025) · Telecom · doi:10.3390/telecom6030052 · Cited by 1
Alvar whole-body model: impact of muscle anisotropy on computational dosimetry
Kangasmaa, O., Lehtinen, T., & Laakso, I. (2025) · Physics in Medicine and Biology · doi:10.1088/1361-6560/adfe31 · Cited by 1
“…and HANAKO (Nagaoka et al 2003); the HDRK-Man (Kim et al 2008) and HDRK-Woman (Yeom et al 2014); a virtual population which includes, e.g. adults Duke and Ella, and several other models with various ages (Christ et al 2009, Gosselin et al 2014); and a Chinese adult male and female (Wu et al 2011).”
Assessing exposure from different vehicular antennas in military applications: a computational study
Colella, M., Biscarini, M., Ferrante, D., Pellegrino, G., de Meis, M., Mei, L., Cavagnaro, M., Apollonio, F., & Liberti, M. (2025) · Frontiers in Public Health · doi:10.3389/fpubh.2025.1620240 · Cited by 1
“Subsequently, operator exposure was investigated using the whole-body male model Duke [Virtual Population, ViP v.3.1 (32)] representing a 34-year-old man, 1.77 m tall and weighing 70 kg.”
InfluentialElectrical anisotropy of fascicles in a realistic neck model for phrenic nerve stimulation
Wegert, L., Ziółkowski, M., Hunold, A., Lange, I., Kalla, T., & Haueisen, J. (2025) · COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · doi:10.1108/compel-12-2024-0528 · Cited by 1
Shen, A., Akter, M. K., Zuo, Z., Zhang, L., Zheng, J., Steckner, M., Du, M., & Chen, J. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70123 · Cited by 1
Physical and mechanical evaluation of medical devices
Ali, K. A., Shaw, T. K., Sarkar, S., Bishal, A., Mukherjee, R., & Hossain, C. M. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-32828-2.00013-2 · Cited by 1
Ultimate Intrinsic SNR in the Torso of Realistic Body Models
Wang, Y., May, M. W., Gratz, M., Ladd, M. E., & Orzada, S. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70202 · Cited by 1
“The Duke and the Ella body models from the Virtual Family [22, 23] (IT’IS Foundation, Zürich, Switzerland) were used for the uiSNR simulations.”
Electromagnetic Exposure from RF Antennas on Subway Station Attendant: A Thermal Analysis
Li, J., Zhang, Q., & Lu, M. (2026) · Sensors · doi:10.3390/s26020709 · Cited by 1
“The human body model used in this study is obtained from the Virtual Family Project and consists of a high-resolution, MRI-based anatomical model of an adult female, Ella [34], as shown in Figure 8.”
Lv, Z., Zhao, K., Li, J. H., Li, S., Zhao, X., Xu, A., Wu, Y., Gao, H., Li, J. H., Sun, H., et al. (2026) · Stem Cell Research & Therapy · doi:10.1186/s13287-026-04937-2 · Cited by 1
Schneeweiss, P., Hirtl, R., Jhala, T., Überbacher, R., Cecil, S., Becker, C., Bömmels, I., Alteköster, C., & Schmid, G. (2026) · Journal of Radiological Protection · doi:10.1088/1361-6498/ae553b · Cited by 1
“The high-resolution possible whole-body models ‘Duke’ (34 year-old man), ‘Ella’ (26 year-old woman), and ‘Roberta’ (5 year-old girl) from the Virtual Population V3 were used for computations of induced current densities and induced electric field strengths (Christ et al 2010, Gosselin et al 2014).”
Dolciotti, N., Colella, M., Marracino, P., Paffi, A., Caramazza, L., Fontana, S., Mannino, L., Moreno‐Manzano, V., Consales, C., Apollonio, F., et al. (2026) · Bioelectricity · doi:10.1177/25763113261441510 · Cited by 1
“It counts 179 structures segmented from MRI and CT scans, providing high-resolution anatomical detail, 35 including nerve trajectories, necessary for the neurofunctionalized study.”
Zhou, W.-Y., Luo, M.-F., Wang, P., Li, Y. X., & Lu, M. (2026) · Bioelectromagnetics · doi:10.1002/bem.70055 · Cited by 1
“To better analyze the radiation dose absorbed by different tissues in male and female bodies, adult male and female models were created using COMSOL Multiphysics, based on international standards (Gosselin et al. 2014), as shown in Figure 3a.”
Aldelemy, A., Al-Dulaimi, A., Adjei, E., Siaw, P. O., Ali, N. T., Walukiewicz, I., Doychinov, V., Twigg, P. C., & Abd‐Alhameed, R. A. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3706360 · Cited by 1
“Virtual population models, including the IT’IS Foundation’s ViP series, o ff er age-and gender-specific anatomical representations suitable for dosimetry and imaging studies [41].”
Wydaeghe, R., Stroobandt, B., Gallucci, S., Parazzini, M., Tognola, G., Wiart, J., Vermeeren, G., Guxens, M., Tanghe, E., & Joseph, W. (2026) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ae97ac · Cited by 1
“This study addresses these gaps with FDTD simulations covering 15 frequencies (450 MHz–26 GHz), four virtual population (ViP) phantoms (Gosselin et al 2014) (two adults, two children), and two exposure scenarios: environmental (isotropic plane-wave illumination from 12 directions with two…”
InfluentialBarretto, E. C. S., Chavannes, N., & Douglas, M. G. (2016) · European Conference on Antennas and Propagation · doi:10.1109/eucap.2016.7481826 · Cited by 1
Zradziński, P. (2016) · Podstawy i Metody Oceny Środowiska Pracy · doi:10.5604/1231868x.1222127 · Cited by 1
Temperature variations for adults and child human models inside elevator cabin
Karatsi, I., Bakogianni, S., & Koulouridis, S. (2016) · Digest - IEEE Antennas and Propagation Society. International Symposium · doi:10.1109/aps.2016.7696523 · Cited by 1
Sensitivity-Controlled Electrical Impedance Tomography for Abdomen Lesion Imaging
Yu, H., Ren, S., & Dong, F. (2018) · Chinese Control Conference (CCC) · doi:10.23919/chicc.2018.8484207 · Cited by 1
Influence of Lesions in Human Abdomen on Ultrasonic Echo Signal
Guo, D., Ren, S., & Dong, F. (2018) · Chinese Control Conference (CCC) · doi:10.23919/chicc.2018.8482975 · Cited by 1
Xu, X. G. (2018) · Health Physics · doi:10.1097/hp.0000000000001007 · Cited by 1
Implant Safety: Novel Mechanistic Model and Approach for Safety Assessment at WPT Frequencies
Liorni, I., Neufeld, E., Kühn, S., & Kuster, N. (2018) · IEEE Wireless Power Transfer Conference · doi:10.1109/wpt.2018.8639464 · Cited by 1
Self-citationFiocchi, S., Bonato, M., Chiaramello, E., Gallucci, S., Tognola, G., Ravazzani, P., & Parazzini, M. (2020) · IEEE Mediterranean Electrotechnical Conference (MELECON) · doi:10.1109/melecon48756.2020.9140639 · Cited by 1
Lubba, C. H. (2020) · Spiral (Imperial College London) · doi:10.25560/80541 · Cited by 1
Computational and Phantom-Based Feasibility Study of 3D dcNCI With Ultra-Low-Field MRI
Höfner, N., Storm, J.-H., Hömmen, P., Cassara, A. M., & Körber, R. (2021) · Frontiers in Physics · doi:10.3389/fphy.2021.647376 · Cited by 1
“This could be done replacing simplified phantom models with high-resolution anatomical human head models, such as the ones of the Virtual Population (IT’IS Foundation, Zurich, Switzerland) [43] or the MIDA head model [44], combined with realistic electrophysiological models of neuronal networks.”
MethodNew CTIA Standard Phantoms for OTA Testing
Foegelle, M. D., Kuster, N., Rouholahnejad, F., Ofli, E., & Li, K. (2021) · European Conference on Antennas and Propagation · doi:10.23919/eucap51087.2021.9411203 · Cited by 1
Self-citationEfficient and Flexible Huygens’ Source Replacement of mm-scale Human Brain Implants
Yang, C. F., Schierholz, M., Trunczik, E., Helmich, L. M., Brüns, H., & Schuster, C. (2021) · IEEE International Symposium on Electromagnetic Compatibility · doi:10.1109/emc/si/pi/emceurope52599.2021.9559298 · Cited by 1
Simplified Human Body Models with Reduced Types of Tissues for MRI at 1.5T
Xia, M., Guo, R., Zheng, J., Shrivastava, D., Kainz, W., & Chen, J. (2021) · Digest - IEEE Antennas and Propagation Society. International Symposium · doi:10.1109/aps/ursi47566.2021.9703743 · Cited by 1
Self-citationOn Anatomical Human Models for Evaluation of Exposure to Electromagnetic Fields
Ponti, C., & Schettini, G. (2022) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroind4.0iot54413.2022.9831656 · Cited by 1
RF-induced Heating Evaluation for Passive Device in Tissue-Reduced Virtual Family Models at 1.5 T
Xia, M., Guo, R., Zheng, J., & Chen, J. (2022) · IEEE International Symposium on Electromagnetic Compatibility · doi:10.1109/emcsi39492.2022.9889637 · Cited by 1
An Optimization of a Circular Antenna Array for On-Body Communication
Herssens, H., & Thielens, A. (2023) · European Conference on Antennas and Propagation · doi:10.23919/eucap57121.2023.10133253 · Cited by 1
Possible differences in exposure from TMS treatment between male and female operators
D’Agostino, S., Colella, M., Falsaperla, R., Liberti, M., & Apollonio, F. (2023) · URSI General Assembly and Scientific Symposium · doi:10.23919/ursigass57860.2023.10265602 · Cited by 1
“From what was found in the literature, it was deemed worthwhile to analyze the possible differences between male (Duke) and female (Ella) models of the Virtual Population (ViP) [8] in terms of induced quantities in clinicians during TMS treatments.”
BackgroundKuang, J., Qin, Y., & Zhang, S. (2023) · Recent Patents on Engineering · doi:10.2174/0118722121269816230926120046 · Cited by 1
A 3D surface coil with deep learning‐based noise reduction for parotid gland imaging at 7T
Gökyar, S., Zhao, C., Shajan, G., Tang, L., West, J. D., Kokot, N., & Wang, D. J. J. (2024) · iRadiology · doi:10.1002/ird3.79 · Cited by 1
“[12], a full wave electromagnetic solver, and realistic body models (i.e., Duke and Ella) from the library of IT’IS [13] to calculate the necessary circuit parameters [6], RF transmit field (B 1 þ ) of the 3D Coil, and RF receive fields (B 1”
Computational dosimetry on military crew exposed to HF vehicular antenna in near field condition
Colella, M., Biscarini, M., Pellegrino, G., de Meis, M., Cavagnaro, M., Apollonio, F., & Liberti, M. (2024) · URSI Atlantic Radio Science Conference · doi:10.46620/ursiatrasc24/lqyy7601 · Cited by 1
“The standard adult male Duke from the Virtual Population (ViP v.3 [13], i.e., 34-year-old, 1.77 m tall and 70 kg) modeled the operator and was placed through the manhole, with 70 cm of the body (i.e. the trunk) standing outside the vehicle, and leaning towards the edge of the manhole, with one arm…”
MethodInfluentialNumerical Exposure to Realistic and Planar Body Models: Effect of the Polarization
Colella, M., Meo, S. D., Liberti, M., Pasian, M., & Apollonio, F. (2024) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea60663.2024.10596904 · Cited by 1
“As anthropomorphic model, the Virtual Population (ViP v.3.1) Duke [15] was considered.”
MethodInfluentialSynthetic pulse wave dataset for analysis of vascular ageing in elderly patients
Rogov, A. A., Gamilov, T. M., Bragina, A. E., Abdullaev, M., Дружинина, Н. А., Rodionova, Y., Shikhmagomedov, R., Tyulin, M., & Podzolkov, V. I. (2024) · Mathematical Modelling of Natural Phenomena · doi:10.1051/mmnp/2024017 · Cited by 1
“There are a number of virtual population datasets suitable for various tasks: anatomy studies and meshing [3], pharmacology [4], pulse wave analysis [5].”
BackgroundDesign of a Cryogenic RF Coil Prototype for a Full Body 1.5T MRI Receive Array
Zhurbenko, V., Gosselink, M. W. J. M., Voogt, I. J., Alborahal, C., Hoogduin, H. M., Jepsen, R. A., Sanchez-Heredia, J. D., & Klomp, D. W. J. (2024) · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition · doi:10.58530/2024/1598 · Cited by 1
“The field in the loop is analyzed with CST frequency domain solver using adaptive tetrahedral mesh refinement and a Virtual Family Duke v2 shell phantom 3, 4 .”
An evaluation of the coax monopole antenna as a transmit array element for head imaging at 14 T
Budé, L. M. I., Vat, K., Voogt, I. J., Zivkovic, I., & Raaijmakers, A. J. E. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30464 · Cited by 1
Dosimetry Computation Based on Near-Field Measurements on a Huygens Box Surrounding the Antenna
Lopes, L. D. N., Ijjeh, A., Mifdal, S., Debard, A., Cueille, M., Dubard, J.-L., Bagheriasl, M., Richard, L., Gouriou, C., & Pannetrat, S. (2025) · European Conference on Antennas and Propagation · doi:10.23919/eucap63536.2025.10999870 · Cited by 1
“Moreover, as the simulation tools, the human phantoms (digital [21] or physical [22] [23]), and the measurements tools advance, the field of dosimetry advances as well.”
3D–1D modelling of cranial mesh heating induced by low or medium frequency magnetic fields
Arduino, A., Bottauscio, O., Grappein, D., Scialò, S., Vicini, F., Zanovello, U., & Zilberti, L. (2025) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2025.109009 · Cited by 1
“To this end, the anatomical human model Glenn from the Virtual Population [33] was equipped with the geometrical model of the semi-rigid cranial mesh described in Section 2.2.1.”
InfluentialA CG-FFT Based Fast Full Wave Imaging Method and its Potential Industrial Applications
Yu, Z. (2015) · DukeSpace (Duke University) · Cited by 1
Numeric Analysis of Temperature Distribution in Man using a 3D Human ModelPreprint
Mfolozi, S., Malan, A. G., Bello‐Ochende, T., & Martin, L. J. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/330357 · Cited by 1
“0––a set of fifteen high end, high resolution, whole-body computational human avatars built from MRIs of healthy male and female, adult and children volunteers [19].”
BackgroundAnalytic on-body antenna and propagation models
Grimm, M. (2019) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/4317 · Cited by 1
Lloyd, B., Farcito, S., Cassara, A. M., Zhuang, K., Neufeld, E., & Kuster, N. (2020) · The FASEB Journal · doi:10.1096/fasebj.2020.34.s1.07492 · Cited by 1
Self-citationDunne, E. (2021) · Arrow@dit (Dublin Institute of Technology) · doi:10.13025/15946 · Cited by 1
Pophof, B., & Brix, G. (n.d.) · Imaging and Radiation Research · doi:10.24294/irr.v5i2.1757 · Cited by 1
Jimenez, H. (2018) · WakeSpace Scholarship (Wake Forest University) · Cited by 1
Laakso, I., Paulides, M. M., Kodera, S., Ahn, S., Brace, C. L., Cavagnaro, M., Chen, J., Deng, Z., Santis, V. D., Diao, Y., et al. (2025) · TU/e Research Portal · doi:10.48550/arxiv.2509.21165 · Cited by 1
Métamodélisation pour le calcul rapide d'exposition des personnes aux systèmes haute puissance
Lagouanelle, P. (2023) · theses.fr (ABES) · doi:10.70675/9c2cf1cdz80b6z4dc2z87ffz303f4b130465 · Cited by 1
Human exposure to low-frequency magnetic field: new methodologies for numerical dosimetry
Gubernati, A. C. (2022) · PORTO@Iris · Cited by 1
Numerical simulations in virtual anatomical models: The devil is in the details
Gosselin, M., Neufeld, E., Payne, D., & Kuster, N. (2015) · Asia-Pacific International Symposium on Electromagnetic Compatibility (APEMC) · doi:10.1109/apemc.2015.7175297
Self-citationYu, Z., & Liu, Q. H. (2015) · IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications · doi:10.1109/imws-bio.2015.7303792
Fourth international workshop on computational phantoms: special issue
Xu, X. G., & Kuster, N. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/5207
Self-citationZhang, Y., Feng, Y., Zhang, Y., Ming, X. G., Yu, J. B., Carlson, D. J., Kim, J., & Deng, J. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.04.010
Slovák, M. (2015) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York)
Effect of electromagnetic fields induced by mobile devices in the human brain
Vieira, V. F. M. (2017) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/h3g9-ct68
The role of the skin modeling in LF dosimetry
Santis, V. D., Campi, T., Cruciani, S., & Feliziani, M. (2017) · International Applied Computational Electromagnetics Society Symposium - Italy · doi:10.23919/ropaces.2017.7916319
“In this work we focus on the validity of the skin layer currently implemented in up-to-date human-body anatomical models like the Virtual Population (ViP), from the IT’IS Foundation [1], or the Japanese models from the NICT Group [2].”
MethodEmerging Technologies for Mobile Health
Karathanasis, K. T., & Nikita, K. S. (2017) · CRC Press eBooks · doi:10.1201/9781315155821-14
Comparison of human EM-exposure in fifth generation wireless technologies : ATTO vs. massive MIMO
Shikhantsov, S., Thielens, A., Vermeeren, G., Demeester, P., Martens, L., & Joseph, W. (2017) · Ghent University Academic Bibliography (Ghent University)
Cassara, A. M., Neufeld, E., Montanaro, H., & Kuster, N. (2017) · URSI General Assembly and Scientific Symposium · doi:10.23919/ursigass.2017.8105347
“Detailed anatomical computational models, such as the Virtual Population [1] and MIDA models [2], have been functionalized through anatomically realistic integration of electrophysiologically and morphologically realistic cortical pyramidal neuronal models relevant to transcranial stimulation (e.”
MethodSelf-citationNumerical assessment of human electromagnetic exposure in ATTO-cell wireless networks
Shikhantsov, S., Thielens, A., Vermeeren, G., Demeester, P., Martens, L., Torfs, G., & Joseph, W. (2017) · Ghent University Academic Bibliography (Ghent University)
Ultrasonic testing on interface information of human abdominal organs
Guo, D., Ren, S., & Dong, F. (2018) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2018.8409520
“The specimen is from IT’S FOUNDATION [21].”
A volume integral equation method for MRI-based electrical properties tomography
Hong, R., Li, S., Zhang, J., Zhang, Y., Liu, N., Yu, Z., & Liu, Q. H. (2017) · Asia-Pacific Conference on Antennas and Propagation (APCAP) · doi:10.1109/apcap.2017.8420782
Validation of Electromagnetic CAD Human Phantoms
Tankaria, H. V. (2017) · Digital WPI
Development of CAD Human Model for Medical Electromagnetic Simulations
Zagalskaya, M. M. (2017) · Digital WPI
Full-body Shell Creation for CAD Virtual Humans including Tightly-Spaced, Enclosed Shells
Htet, A. T. (2018) · Digital WPI
Martins, A. C. D. S. (2018) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Foerster, M. (2017) · edoc (University of Basel) · doi:10.5451/unibas-006849073
Novel Approach for Compliance Testing of WPT Systems with Basic Restrictions
Liorni, I., Capstick, M. H., Kühn, S., & Kuster, N. (2018) · IEEE Wireless Power Transfer Conference · doi:10.1109/wpt.2018.8639099
Self-citationBirks, L. E. (2018) · Repositori digital de la UPF (Universitat Pompeu Fabra)
Religi, A. (2018) · Archive ouverte UNIGE (University of Geneva) · doi:10.13097/archive-ouverte/unige:112464
Computational Human Models in Cardiovascular Imaging: From Design to Generations
Salih, N. M., & Dewi, D. E. O. (2019) · Series in bioengineering · doi:10.1007/978-981-10-8405-8_3
Shikhantsov, S., Thielens, A., Vermeeren, G., Tanghe, E., Demeester, P., Torfs, G., Martens, L., & Joseph, W. (2019) · Ghent University Academic Bibliography (Ghent University)
An Abdominal Imaging Method Combined Electrical with Ultrasound Tomography
Li, P., Zhao, S., & Dong, F. (2019) · Chinese Control Conference (CCC) · doi:10.23919/chicc.2019.8866433
RF Exposure Due to Mobile Devices Operated Close to the Human Body
Rodríguez, C. E. F., Bulla, G., & de Salles, Á. A. A. (2019) · European Microwave Conference (EuMC) · doi:10.23919/eumc.2019.8910925
“8 software from SPEAG and CST-Studio from Dassault) together with realistic human models for different ages [10] and a Specific Anthropomorphic Mannequin – SAM [11] are employed.”
Menelik: A detailed anatomical human head model for electromagnetic computations
Kibret, B., & Premaratne, M. (2019) · doi:10.1109/iemantenna.2019.8928875
“There are more than thirty computational human models reported in the literature [8], [9], [10], [11], [12], [13], [14], [15], [16], [17], [18], [19], [20], [21], [22], [23], [24], [25], [26], [7], [27], [28], [29].”
Antennas and Wave Propagation in Wireless Body Area Networks: Design and Evaluation Techniques
Alemaryeen, A. (2019) · UND Scholarly Commons (University of North Dakota)
Ultrasound-Guided Weighting of Regularization Parameters for EIT Image Reconstruction
Han, J., Zhao, S., Ren, S., & Dong, F. (2020) · Chinese Control Conference (CCC) · doi:10.23919/ccc50068.2020.9189275
Chiaramello, E., Tognola, G., Bonato, M., Gallucci, S., Magne, I., Souques, M., Fiocchi, S., Parazzini, M., & Ravazzani, P. (2020) · URSI General Assembly and Scientific Symposium · doi:10.23919/ursigass49373.2020.9232237
Development of a Method for Thermal Simulations Using USARIEM Avatars in COMSOL Multiphysics
Sanford, D. P., & Zientara, G. P. (2020)
Plumley, A., Watkins, L., & Kopanoğlu, E. (2020) · ORCA Online Research @Cardiff (Cardiff University)
Highly Efficient Wireless Power Transfer Systems for Wearable and Implantable Devices
Barreto, J., Kaddour, A.-S., & Georgakopoulos, S. V. (2021) · The ... IEEE Annual Wireless and Microwave Technology Conference · doi:10.1109/wamicon47156.2021.9443592
Motion-resolved B1+ prediction using deep learning for real-time pTx pulse-design
Plumley, A., Watkins, L., Murphy, K., & Kopanoğlu, E. (2021) · ORCA Online Research @Cardiff (Cardiff University)
Parallel transmit coil dimensions affect SAR sensitivity to motion at 7T
Plumley, A., Schmid, P., & Kopanoğlu, E. (2021) · ORCA Online Research @Cardiff (Cardiff University)
Novel Conformal Strongly Coupled Magnetic Resonance Systems
Barreto, J. (2020) · FIU - Digital Commons (Florida International University) · doi:10.25148/etd.fidc009223
Lee, P.-C. (2019) · University of Minnesota Digital Conservancy (University of Minnesota)
Arduino, A., Bottauscio, O., & Zilberti, L. (2021) · URSI General Assembly and Scientific Symposium · doi:10.23919/ursigass51995.2021.9560241
Review of Existing Research on the Effects of Human Exposure to RF EMF
Lee, A., & Choi, H. (2021) · The Journal of Korean Institute of Electromagnetic Engineering and Science · doi:10.5515/kjkiees.2021.32.10.857
Rafols, R. M., Gallego, A. G., Orantes, G. C., & Torres, G. (1994) · Cuadernos de pedagogía
Yao, A., Yang, P., Ma, M., & Pei, Y. (2021) · Frontiers in Public Health · doi:10.3389/fpubh.2021.793418
“RF-Exposure Big-Data Library Five high-resolution anatomical models from Virtual Population (ViP) (15) representing a large population range are selected and listed in Table 1.”
BackgroundStaebler, P. (2017) · Wiley eBooks · doi:10.1002/9781119384533.biblio
Emerging Technologies for Mobile Health
Karathanasis, K. T., & Nikita, K. S. (2017) · CRC Press eBooks · doi:10.1201/9781315155821-15
Wiart, J. (2016) · Wiley eBooks · doi:10.1002/9781119285137.biblio
Seidenbusch, M. C., Rösenberger, V., & Schneider, K. O. (2019) · Springer eBooks · doi:10.1007/978-3-030-18504-6_28
Far-Field Numerical Radio-Frequency Dosimetry of Insects
Thielens, A. (2022) · URSI Atlantic Radio Science Conference · doi:10.23919/at-ap-rasc54737.2022.9814369
“Numerical dosimetry has been very successful for vertebrates [5], [6] for which several highly-detailed models exist [7], [8].”
BackgroundHuman RF-EMF Exposure Assessment for a Wearable Device by Stochastic Dosimetry
Gallucci, S., Bonato, M., Benini, M., Chiaramello, E., Fiocchi, S., Tognola, G., & Parazzini, M. (2022) · Mediterranean Microwave Symposium · doi:10.1109/mms55062.2022.9825623
Metadata
- Authors
- Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., Cherubini, E., Szczerba, D., Kainz, W., & Kuster, N.
- Affiliations
- ETH Zurich (CH)
- Foundation for Research on Information Technologies in Society (CH)
- United States Food and Drug Administration (US)
- Corresponding author
- Gosselin, Marie-Christine
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-08-21
- Volume
- 59
- Issue
- 18
- Pages
- 5287-5303
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2102862641
- Cited by
- 520
- References
- 52
- Citations by year
- 2026: 34 · 2025: 64 · 2024: 44 · 2023: 50 · 2022: 61 · 2021: 52 · 2020: 53 · 2019: 45 · 2018: 42 · 2017: 35 · 2016: 20 · 2015: 14 · 2014: 3
- FWCI
- 12.45
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- European Commission (FP7/2007, 282891)
- Eidgenössische Technische Hochschule Zürich
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
- Keywords
- virtual population, MRI safety, spinal implants, surface processing, electromagnetic dosimetry, radiofrequency exposure, unstructured grid
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Child, Child, Preschool, Computer Simulation, Equipment and Supplies, Female, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Male, Middle Aged, Models, Anatomic, Models, Theoretical, Radiometry, Surface Properties, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.