First experimental evidence of the feasibility of multi-color magnetic particle imaging
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Magnetic particle imaging is a new approach to visualizing magnetic nanoparticles. It is capable of 3D real-time in vivo imaging of particles injected into the blood stream and is a candidate for medical imaging applications. To date, only one particle type has been imaged at a time, however, the ability to separate signals acquired simultaneously from different particle types or from particles in different environments would substantially increase the scope of the method. Different colors could be assigned to different signal sources to allow for visualization in a single image. Successful signal separation has been reported in spectroscopic experiments, but it was unclear how well separation would work in conjunction with spatial encoding in an imaging experiment. This work presents experimental evidence of the separability of signals from different particle types and aggregation states (fluid versus powder) using a 'multi-color' reconstruction approach. Several mechanisms are discussed that may form the basis for successful signal separation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276 · cited 1×
“0031-9155/15/051775+17$33.00 © 2015 Institute of Physics and Engineering in Medicine Printed in the UK can spectrally separate signals from water and fat protons, because their chemical environment leads to different shifts of the resonance frequency (Dixon 1984).”
BackgroundInfluentialEnergy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,003
Self-citationClinical applications of magnetic nanoparticles for hyperthermia
Thiesen, B., & Jordan, A. (2008) · International Journal of Hyperthermia · doi:10.1080/02656730802104757 · Cited by 829 · cited 1×
“A potential application that could arise from this combination is the simultaneous visualization and temperature measurement based on the signal generated from particles used in magnetic hyperthermia applications (Thiesen and Jordan 2008).”
BackgroundSchlomka, J. P., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/002 · Cited by 801 · cited 3×
“The system has selection field gradients of J Rahmer et al Phys. Med. Biol. 60 (2015) 1775”
BackgroundInfluentialThree-dimensional real-time in vivo magnetic particle imaging
Weizenecker, J., Gleich, B., Rahmer, J., Dahnke, H., & Borgert, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/l01 · Cited by 651 · cited 2×
“For 3D MPI, these drive fields are typically applied in all three spatial directions and are operated at slightly different frequencies (Weizenecker et al 2009).”
BackgroundSelf-citationSignal encoding in magnetic particle imaging: properties of the system function
Rahmer, J., Weizenecker, J., Gleich, B., & Borgert, J. (2009) · BMC Medical Imaging · doi:10.1186/1471-2342-9-4 · Cited by 345 · cited 2×
“Its 3D shape has been determined for the cases of ideal particles having a step-like magnetization curve (Rahmer et al 2009) and for particles with a Langevin magnetization curve (Goodwill and Conolly 2011).”
BackgroundMethodSelf-citationMultidimensional X-Space Magnetic Particle Imaging
Goodwill, P. W., & Conolly, S. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2125982 · Cited by 319 · cited 4×
“Its 3D shape has been determined for the cases of ideal particles having a step-like magnetization curve (Rahmer et al 2009) and for particles with a Langevin magnetization curve (Goodwill and Conolly 2011).”
BackgroundMethodInfluentialA simulation study on the resolution and sensitivity of magnetic particle imaging
Weizenecker, J., Borgert, J., & Gleich, B. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/21/001 · Cited by 267 · cited 1×
“While MPI reconstruction for a single particle type is quantitative (Weizenecker et al 2007, Lu et al 2013), it has to be shown whether this holds for multi-color MPI as well.”
MethodSelf-citationMagnetization response spectroscopy of superparamagnetic nanoparticles for magnetic particle imaging
Biederer, S., Knopp, T., Sattel, T. F., Lüdtke-Buzug, K., Gleich, B., Weizenecker, J., Borgert, J., & Buzug, T. M. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/20/205007 · Cited by 248
Self-citation
Cited by
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,075
Tay, Z. W., Chandrasekharan, P., Chiu-Lam, A., Hensley, D. W., Dhavalikar, R., Zhou, X. Y., Yu, E. Y., Goodwill, P. W., Zheng, B., Rinaldi, C., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b00893 · Cited by 459
Magnetic Particle Imaging: A Novel in Vivo Imaging Platform for Cancer Detection
Yu, E. Y., Bishop, M., Zheng, B., Ferguson, R. M., Khandhar, A. P., Kemp, S. J., Krishnan, K. M., Goodwill, P. W., & Conolly, S. M. (2017) · Nano Letters · doi:10.1021/acs.nanolett.6b04865 · Cited by 366
Advances in the Application of Magnetic Nanoparticles for Sensing
Gloag, L., Mehdipour, M., Chen, D., Tilley, R. D., & Gooding, J. J. (2019) · Advanced Materials · doi:10.1002/adma.201904385 · Cited by 364
Zheng, B., von See, M. P., Yu, E., Gunel, B., Lu, K., Vazin, T., Schaffer, D. V., Goodwill, P. W., & Conolly, S. M. (2016) · Theranostics · doi:10.7150/thno.13728 · Cited by 322
Magnetic particle imaging: from proof of principle to preclinical applications
Knopp, T., Gdaniec, N., & Möddel, M. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa6c99 · Cited by 238
Superparamagnetic iron oxides as MPI tracers: A primer and review of early applications
Bulte, J. W. M. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.12.007 · Cited by 202
Chandrasekharan, P., Tay, Z. W., Hensley, D., Zhou, X. Y., Fung, B. K., Colson, C., Lu, Y., Fellows, B. D., Huynh, Q., Saayujya, C., et al. (2020) · Theranostics · doi:10.7150/thno.40858 · Cited by 197
“MPI is being developed in many academic labs including from Germany [19, 34, 35], Turkey [36], Japan [37], China [38], Canada [39, 40] and the USA [31, 41-45].”
Background
Metadata
- Authors
- Rahmer, J., Halkola, A., Gleich, B., Schmale, I., & Borgert, J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2015-02-06
- Volume
- 60
- Issue
- 5
- Pages
- 1775-1791
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1976014636
- Cited by
- 170
- References
- 33
- FWCI
- 9.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.