Pressure-diameter relationships of segments of human finger arteries
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Pressure-diameter relationships of segments of human finger arteries, aged 57-85 years, were measured in vitro. The arteries, obtained at autopsy within 48 h after death, were stored in glucose-free Tyrode at 4 degrees C. Experiments began within 40 h after autopsy. The diameter responses to various transmural pressure changes, with and without the addition of noradrenaline to the Tyrode solution in the specimen chamber, were compared with the responses of freshly excised rat tail arteries. In general, pressure-diameter relations of human finger artery segments were similar to those of rat tail artery segments, with a steep slope in the collapse region near zero pressure. Also, spontaneous rhythmic contractions and myogenic activity induced by high transmural pressures were similar to those observed in the fresh rat tail arteries. Human finger arteries, however, could contract to complete closure both spontaneously and after addition of noradrenaline, while rat tail arteries did not. The diameter changes of the arterial segments during forced 1 Hz oscillations of 20-50 mm Hg (2.7-6.7 kPa) amplitude superimposed on a mean transmural pressure were substantially smaller than those during quasi-steady inflation-deflation ramps over the same pressure range, indicating the presence of a strong viscous wall component.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yamakoshi, K., Shimazu, H., Shibata, M., & Kamiya, A. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442797 · Cited by 129
Cited by
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 366
Tardy, Y., Meister, J. J., Perret, F., Brunner, H. R., & Arditi, M. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/1/003 · Cited by 270
Optical blood pressure estimation with photoplethysmography and FFT-based neural networks
Xing, X., & Sun, M. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003007 · Cited by 265
Omboni, S., Parati, G., Frattola, A., Mutti, E., Di Rienzo, M., Castiglioni, P., & Mancia, G. (1993) · Hypertension · doi:10.1161/01.hyp.22.1.26 · Cited by 224
Ding, X.-R., Zhao, N., Yang, G.-Z., Pettigrew, R. I., Lo, B., Miao, F., Li, Y., Liu, J., & Zhang, Y.-T. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2620995 · Cited by 181
The effect of contacting force on photoplethysmographic signals
Teng, X. F., & Zhang, Y. T. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/5/020 · Cited by 171
Boehmer, R. D. (1987) · Journal of Clinical Monitoring · doi:10.1007/bf03337384 · Cited by 160
“Studies of these characteristics, done both noninvasively and in vitro on excised arteries from a human finger [6], have indicated a nonlinear relation between P, and volume (Fig 2).”
BackgroundTheoretical study on the effect of sensor contact force on pulse transit time
Teng, X.-F., & Zhang, Y.-T. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.900815 · Cited by 94
“This model has been adopted by other researchers for finger - relationship analysis [38], [39] and supported by the experimental results [32], [33], [40].”
Wearable, Cuff-less PPG-Based Blood Pressure Monitor with Novel Height Sensor
Shaltis, P. A., Reisner, A., & Asada, H. H. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260027 · Cited by 77
“It has been suggested that the PPG-based, volumetric changes are related to the patient’s ABP through a nonlinear vascular compliance relationship [ 5 ].”
BackgroundThe effect of applied sensor contact force on pulse transit time
Teng, X. F., & Zhang, Y. T. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/8/002 · Cited by 53
Metadata
- Authors
- Langewouters, G. J., Zwart, A., Busse, R., & Wesseling, K. H.
- Venue
- Clinical Physics and Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1986-02
- Volume
- 7
- Issue
- 1
- Pages
- 43-55
- ISSN
- 0143-0815 (ISSN-L)
- OpenAlex
- W2071224021
- Cited by
- 91
- References
- 1
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.