Mimicking the nanofeatures of bone increases bone-forming cell adhesion and proliferation
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
There is a great need to design better orthopaedic implant devices by modifying their surface properties. In this respect, one approach that has received much attention of late is the simulation of the surface roughness of bone in synthetic orthopaedic implant materials. Bone has numerous nanometre features due to the presence of nanostructured entities such as collagen and hydroxyapatite. Despite this fact, current orthopaedic implant materials are smooth at the nanoscale. Previous studies have measured increased osteoblast (bone-forming cell) functions on biologically inspired nanophase titania compared to conventional titania formulations. In fact, in vitro calcium deposition by osteoblasts was up to three times higher on nanostructured compared to conventional titania. However, it was unclear in those studies what underlying surface properties (roughness, crystallinity, crystal phase, chemistry, etc) promoted enhanced functions of osteoblasts on nanophase titania. For that reason, the objective of the present in vitro study was to specifically determine the role nanostructured surface roughness of titania had on increasing functions of osteoblasts. To achieve this, the surface roughness of nanophase and conventional titania was transferred to a model tissue engineering polymer: poly-lactic- co -glycolic acid (PLGA). Results of the present study demonstrated greater osteoblast adhesion and proliferation for up to 5 days of culture on PLGA moulds of nanophase compared to conventional titania. In this manner, this study elucidated that the property of nanophase titania which increased osteoblast function was a large degree of nanometre surface features that mimicked bone. For this reason, nanophase materials deserve more attention in improving orthopaedic implant applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Osteoblast adhesion on biomaterials
Anselme, K. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00242-2 · Cited by 2,500 · cited 1×
“For example, recent research has been conducted to determine how proteins adsorb and mediate bone cell function on titania, the oxidized layer that forms on titanium (Anselme 2000, Degasne et al 1999, Howlett et al 1994).”
BackgroundEnhanced functions of osteoblasts on nanophase ceramics
Webster, T. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00075-2 · Cited by 1,324 · cited 12×
“Specifically, studies have shown increased osteoblast and osteoclast functions on titania composed of nanometre particles (Webster et al 2000a, 2001b).”
BackgroundMethodResultSelf-citationSpecific proteins mediate enhanced osteoblast adhesion on nanophase ceramics
Webster, T. J., Ergun, C., Doremus, R. H., Siegel, R. W., & Bizios, R. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20000905)51:3<475::aid-jbm23>3.0.co;2-9 · Cited by 989 · cited 12×
“Specifically, studies have shown increased osteoblast and osteoclast functions on titania composed of nanometre particles (Webster et al 2000a, 2001b).”
BackgroundMethodResultSelf-citationOsteoblast adhesion on nanophase ceramics
Webster, T. J., Siegel, R. W., & Bizios, R. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00020-4 · Cited by 926 · cited 3×
“…implants that has received much attention to date is mimicking the surface nanoroughness of tissues on currently used orthopaedic implant materials (Webster et al 1999, 2000a, 2000b, 2001b, 2001a, Webster and Ejiofor 2004, de Oliveira and Nanci 2004, Supronowicz et al 2002, McManus et al 2005,…”
BackgroundMethodSelf-citationIncreased osteoblast adhesion on nanophase metals: Ti, Ti6Al4V, and CoCrMo
Webster, T. J., & Ejiofor, J. U. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.12.002 · Cited by 793 · cited 4×
“…is mimicking the surface nanoroughness of tissues on currently used orthopaedic implant materials (Webster et al 1999, 2000a, 2000b, 2001b, 2001a, Webster and Ejiofor 2004, de Oliveira and Nanci 2004, Supronowicz et al 2002, McManus et al 2005, Chang et al 2004, Lear Swan et al 2005, Zhu et al…”
BackgroundMethodSelf-citationMechanisms of Enhanced Osteoblast Adhesion on Nanophase Alumina Involve Vitronectin
Webster, T. J., Schadler, L. S., Siegel, R. W., & Bizios, R. (2001) · Tissue Engineering · doi:10.1089/10763270152044152 · Cited by 488 · cited 9×
“For example, by just decreasing ceramic grain size to below 100 nm, selective competitive vitronectin adsorption increased by 10% on alumina formulations (Webster et al 2001a); this may in part have promoted osteoblast adhesion on these nanophase alumina substrates.”
BackgroundMethodResultSelf-citationEnhanced osteoclast-like cell functions on nanophase ceramics
Webster, T. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00285-4 · Cited by 445 · cited 9×
“For example, by just decreasing ceramic grain size to below 100 nm, selective competitive vitronectin adsorption increased by 10% on alumina formulations (Webster et al 2001a); this may in part have promoted osteoblast adhesion on these nanophase alumina substrates.”
BackgroundMethodResultSelf-citationSupronowicz, P. R., Ajayan, P. M., Ullmann, K. R., Arulanandam, B. P., Metzger, D. W., & Bizios, R. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10015 · Cited by 366 · cited 2×
“…more conductive for osteoblast function and, subsequently, bone ingrowth (Webster et al 1999, 2000a, 2000b, 2001b, 2001a, Webster and Ejiofor 2004, de Oliveira and Nanci 2004, Supronowicz et al 2002, McManus et al 2005, Chang et al 2004, Lear Swan et al 2005, Wan et al 2005, Zhu et al 2004).”
BackgroundTambasco de Oliveira, P., & Nanci, A. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00539-8 · Cited by 360 · cited 3×
“…more conductive for osteoblast function and, subsequently, bone ingrowth (Webster et al 1999, 2000a, 2000b, 2001b, 2001a, Webster and Ejiofor 2004, de Oliveira and Nanci 2004, Supronowicz et al 2002, McManus et al 2005, Chang et al 2004, Lear Swan et al 2005, Wan et al 2005, Zhu et al 2004).”
BackgroundMethodWan, Y., Wang, Y., Liu, Z., Qu, X., Han, B., Bei, J., & Wang, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.016 · Cited by 342 · cited 2×
“…more conductive for osteoblast function and, subsequently, bone ingrowth (Webster et al 1999, 2000a, 2000b, 2001b, 2001a, Webster and Ejiofor 2004, de Oliveira and Nanci 2004, Supronowicz et al 2002, McManus et al 2005, Chang et al 2004, Lear Swan et al 2005, Wan et al 2005, Zhu et al 2004).”
BackgroundMethod
Cited by
Review on titanium and titanium based alloys as biomaterials for orthopaedic applications
Kaur, M., & Singh, K. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.04.064 · Cited by 1,451
Advancing dental implant surface technology – From micron- to nanotopography
Mendonça, G., Mendonça, D. B. S., Aragão, F. J. L., & Cooper, L. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.012 · Cited by 990
Gittens, R. A., McLachlan, T., Olivares-Navarrete, R., Cai, Y., Berner, S., Tannenbaum, R., Schwartz, Z., Sandhage, K. H., & Boyan, B. D. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.029 · Cited by 827
“The literature on this topic is dominated by studies on the initial interactions between osteoblasts and nanomodified polymeric substrates, and such work has indicated that nanoscale roughness can significantly affect cell adhesion [34], proliferation [35], and spreading [36].”
BackgroundBionanocomposites: A New Concept of Ecological, Bioinspired, and Functional Hybrid Materials
Darder, M., Aranda, P., & Ruiz‐Hitzky, E. (2007) · Advanced Materials · doi:10.1002/adma.200602328 · Cited by 671
Smart polymeric gels: Redefining the limits of biomedical devices
Chaterji, S., Kwon, I. K., & Park, K. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.018 · Cited by 615
Nanomedicine for implants: A review of studies and necessary experimental tools
Liu, H., & Webster, T. J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.049 · Cited by 579
Self-citationLim, J. Y., & Donahue, H. J. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0154 · Cited by 534
Polymer/bioactive glass nanocomposites for biomedical applications: A review
Boccaccini, A. R., Erol, M., Stark, W. J., Mohn, D., Hong, Z., & Mano, J. F. (2010) · Composites Science and Technology · doi:10.1016/j.compscitech.2010.06.002 · Cited by 520
Increased osteoblast and decreased Staphylococcus epidermidis functions on nanophase ZnO and TiO2
Colon, G., Ward, B. C., & Webster, T. J. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30789 · Cited by 425
Self-citationBiomaterials for Bone Regenerative Engineering
Yu, X., Tang, X., Gohil, S. V., & Laurencin, C. T. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400760 · Cited by 418
Bioactive Coatings for Orthopaedic Implants—Recent Trends in Development of Implant Coatings
Zhang, B., Myers, D., Wallace, G., Brandt, M., & Choong, P. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms150711878 · Cited by 394
RAJAGOPALAN, S., & ROBB, R. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.06.001 · Cited by 392
Nanobiomaterial applications in orthopedics
Christenson, E. M., Anseth, K. S., van den Beucken, J. J. J. P., Chan, C. K., Ercan, B., Jansen, J. A., Laurencin, C. T., Li, W., Murugan, R., Nair, L. S., et al. (2007) · Journal of Orthopaedic Research · doi:10.1002/jor.20305 · Cited by 354
Self-citationMisra, S. K., Mohn, D., Brunner, T. J., Stark, W. J., Philip, S. E., Roy, I., Salih, V., Knowles, J. C., & Boccaccini, A. R. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.040 · Cited by 340
Nanotechnology in regenerative medicine: the materials side
Engel, E., Michiardi, A., Navarro, M., Lacroix, D., & Planell, J. A. (2008) · Trends in Biotechnology · doi:10.1016/j.tibtech.2007.10.005 · Cited by 327
Bioactive Glass Nanoparticles: From Synthesis to Materials Design for Biomedical Applications
Vichery, C., & Nedelec, J.-M. (2016) · Materials · doi:10.3390/ma9040288 · Cited by 296
Dorozhkin, S. V. (2009) · Materials · doi:10.3390/ma2041975 · Cited by 267
Barthes, J., Özçelik, H., Hindié, M., Ndreu-Halili, A., Hasan, A., & Vrana, N. E. (2014) · BioMed Research International · doi:10.1155/2014/921905 · Cited by 230
“For instance, the average roughness of bone tissue is 32 nm and bone tissue has a hierarchical structure composed of collagen and hydroxyapatite [36].”
BackgroundCoelho, P. G., Jimbo, R., Tovar, N., & Bonfante, E. A. (2015) · Dental Materials · doi:10.1016/j.dental.2014.10.007 · Cited by 222
“been previously reported [90,106–109], showing unequivocal”
Lamers, E., Frank Walboomers, X., Domanski, M., te Riet, J., van Delft, F. C. M. J. M., Luttge, R., Winnubst, L. A. J. A., Gardeniers, H. J. G. E., & Jansen, J. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.034 · Cited by 215
Marelli, B., Ghezzi, C. E., Mohn, D., Stark, W. J., Barralet, J. E., Boccaccini, A. R., & Nazhat, S. N. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.08.016 · Cited by 204
“Nanosized particles and fibrils have also been demonstrated to induce accelerated mineralization in vivo as they mimic the nanostructural features of bone and teeth [37,38].”
BackgroundEnhancement of in vitro osteogenesis on titanium by chemically produced nanotopography
de Oliveira, P. T., Zalzal, S. F., Beloti, M. M., Rosa, A. L., & Nanci, A. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30955 · Cited by 203
Liberio, M. S., Sadowski, M. C., Soekmadji, C., Davis, R. A., & Nelson, C. C. (2014) · PLoS ONE · doi:10.1371/journal.pone.0112122 · Cited by 85
Hansen, J. C., Yul Lim, J., Xu, L.-C., Siedlecki, C. A., Mauger, D. T., & Donahue, H. J. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.03.018 · Cited by 80
Applications of nanobioceramics to healthcare technology
Feng, J., & Thian, E. S. (2013) · Nanotechnology Reviews · doi:10.1515/ntrev-2012-0065 · Cited by 16
Metadata
- Authors
- Palin, E., Liu, H., & Webster, T. J.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2005-07-18
- Volume
- 16
- Issue
- 9
- Pages
- 1828-1835
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2030550786
- Cited by
- 211
- References
- 22
- FWCI
- 8.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.