Frequency and damping adaptation of a TMD with controlled MR damper
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
This paper describes the new concept of a semi-active tuned mass damper with magnetorheological damper (MR-STMD). The real-time controlled MR damper force emulates controlled damping and a superimposed controllable stiffness force to augment or diminish the force of the passive spring stiffness which enables us to control the MR-STMD natural frequency. Both the damping and natural frequency are tuned according to Den Hartog’s formulae to the actual dominant frequency of the main structure irrespective of whether it is a resonance or a forced frequency. The MR-STMD is experimentally validated on the Empa bridge with a 15.6 m main span for different added masses to shift its resonance frequency −12.2% and +10.4% away from its nominal value. The experimental results are compared to those obtained when the MR-STMD is operated as a passive TMD that is precisely tuned to the nominal bridge. The comparison shows that the MR-STMD outperforms the TMD both in the tuned and all de-tuned cases by up to 63%. Simulations of the MR-STMD concept point out that the proposed semi-active control algorithm is most suitable for MR-STMDs due to the small amount of clipped active forces. A sensitivity analysis demonstrates that the real MR-STMD could be even more powerful if the force tracking errors in the MR damper force due to the current driver and MR fluid dynamics and remanent magnetization effects could be further reduced. The MR-STMD under consideration represents the prototype of the 12 MR-STMDs that have been running on the Volgograd Bridge since late fall 2011.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smart structures: Part I—Active and semi-active control
Fisco, N. R., & Adeli, H. (2011) · Scientia Iranica · doi:10.1016/j.scient.2011.05.034 · Cited by 270
Nagarajaiah, S. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.349 · Cited by 256
Nagarajaiah, S., & Varadarajan, N. (2005) · Engineering Structures · doi:10.1016/j.engstruct.2004.10.015 · Cited by 212
Structures with Semiactive Variable Stiffness Single/Multiple Tuned Mass Dampers
Nagarajaiah, S., & Sonmez, E. (2007) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2007)133:1(67 · Cited by 190 · cited 1×
“Piezo stacks and other actuators are adopted to actively change the geometrical boundary conditions of passive springs which enable us to control the STMD natural frequency [14–16].”
Smart structures: Part II — Hybrid control systems and control strategies
Fisco, N. R., & Adeli, H. (2011) · Scientia Iranica · doi:10.1016/j.scient.2011.05.035 · Cited by 177
(1958) · Journal of the Franklin Institute · doi:10.1016/0016-0032(58)90641-0 · Cited by 169
In Search of Suitable Control Methods for Semi-Active Tuned Vibration Absorbers
Koo, J., Ahmadian, M., Setareh, M., & Murray, T. M. (2004) · Journal of Vibration and Control · doi:10.1177/107754604773732133 · Cited by 133
Weber, F., Boston, C., & Maślanka, M. (2011) · Smart Materials and Structures · doi:10.1088/0964-1726/20/1/015012 · Cited by 97
Self-citationAssessment of long-term behavior of tuned mass dampers by system identification
Weber, B., & Feltrin, G. (2010) · Engineering Structures · doi:10.1016/j.engstruct.2010.08.011 · Cited by 97 · cited 1×
“Small de-tuning effects can also occur due to the temperature dependency of the viscous damping coefficient of the oil damper [8].”
Clipped viscous damping with negative stiffness for semi-active cable damping
Weber, F., & Boston, C. (2011) · Smart Materials and Structures · doi:10.1088/0964-1726/20/4/045007 · Cited by 95 · cited 3×
“Comparing the measured FTEs with the results presented in [30, 33, 43, 44], the FTEs can be denoted as reasonably small.”
Self-citationVibration control of seismic structures using semi-active friction multiple tuned mass dampers
Lin, C.-C., Lu, L., Lin, G., & Yang, T.-W. (2010) · Engineering Structures · doi:10.1016/j.engstruct.2010.07.014 · Cited by 85
Loading models and response control of footbridges excited by running pedestrians
Occhiuzzi, A., Spizzuoco, M., & Ricciardelli, F. (2008) · Structural Control and Health Monitoring · doi:10.1002/stc.248 · Cited by 83
Negative stiffness friction damping for seismically isolated structures
Iemura, H., Igarashi, A., Pradono, M. H., & Kalantari, A. (2006) · Structural Control and Health Monitoring · doi:10.1002/stc.111 · Cited by 75
Semiactive Control of Building Structures with Semiactive Tuned Mass Damper
Lin, P. Y., Chung, L. L., & Loh, C. H. (2005) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/j.1467-8667.2005.00375.x · Cited by 71
Optimal Tuning of Amplitude Proportional Coulomb Friction Damper for Maximum Cable Damping
Weber, F., Høgsberg, J., & Krenk, S. (2010) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2010)136:2(123 · Cited by 67 · cited 1×
“The desired viscous damping coefficient c̃des 2 is emulated by the MR damper by energy equivalent friction damping [41, 42]”
Self-citationWeber, F., & Maślanka, M. (2013) · Smart Materials and Structures · doi:10.1088/0964-1726/23/1/015019 · Cited by 66
Self-citationDamping Torsional Interharmonic Effects of Large Drives
Schramm, S., Sihler, C., Song‐Manguelle, J., & Rotondo, P. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2033274 · Cited by 63
Seismic response control of a cable-stayed bridge using negative stiffness dampers
Li, H., Liu, J., & Ou, J. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.368 · Cited by 62
Mitigation of wind response of a tall building using semi‐active tuned mass dampers
Kang, J., Kim, H., & Lee, D. (2011) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.609 · Cited by 58
Re-tuning tuned mass dampers using ambient vibration measurements
Hazra, B., Sadhu, A., Lourenco, R., & Narasimhan, S. (2010) · Smart Materials and Structures · doi:10.1088/0964-1726/19/11/115002 · Cited by 51 · cited 1×
“All these effects will result in suboptimal TMD tuning and thereby reduced damping of the target mode [5–7].”
Protection of seismic structures using semi‐active friction TMD
Lin, C., Lin, G., & Wang, J. (2009) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.961 · Cited by 50
Tse, K. T., Kwok, K. C. S., Hitchcock, P. A., Samali, B., & Huang, M. F. (2007) · Advances in Structural Engineering · doi:10.1260/136943307781422208 · Cited by 49
Performance of tuned mass dampers against near-field earthquakes
Matta, E. (2011) · Structural Engineering and Mechanics · doi:10.12989/sem.2011.39.5.621 · Cited by 39
Wu, B., Shi, P., & Ou, J. (2011) · Structural Control and Health Monitoring · doi:10.1002/stc.504 · Cited by 39
Optimal semi-active damping of cables: evolutionary algorithms and closed-form solutions
Boston, C., Weber, F., & Guzzella, L. (2009) · Smart Materials and Structures · doi:10.1088/0964-1726/18/5/055006 · Cited by 27
Self-citationDesign of frictional pendulum TMD and its wind control effectiveness
Li, Y. (2009) · Dizhen gongcheng yu gongcheng zhendong · Cited by 27
Adaptive Tuned Mass Damper based on Pre-stressable Leaf-springs
Gsell, D., Feltrin, G., & Motavalli, M. (2007) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x06073641 · Cited by 24 · cited 1×
“Piezo stacks and other actuators are adopted to actively change the geometrical boundary conditions of passive springs which enable us to control the STMD natural frequency [14–16].”
Koo, J., Ahmadian, M., & Setareh, M. (2005) · Journal of vibration and acoustics · doi:10.1115/1.2128647 · Cited by 24
Adaptive Tuned Mass Damper for the Construction of Concrete Piers
Casado, C. M., Poncela, A. V., & Lorenzana, A. (2007) · Structural Engineering International · doi:10.2749/101686607781645806 · Cited by 22
Active mass damper control for cable stayed bridge under construction: an experimental study
Chen, H., Sun, Z., & Sun, L. (2011) · STRUCTURAL ENGINEERING AND MECHANICS · doi:10.12989/sem.2011.38.2.141 · Cited by 16 · cited 1×
“Please notice that the control algorithm should be formulated differently for TMDs with active control devices such as in [11, 12].”
Adaptive Flüssigkeitstilger für Vertikalschwingungen von Ingenieurstrukturen – Teil 2 – Feldversuche
Reiterer, M., Altay, O., Wan‐Wendner, R., Hoffmann, S., & Strauß, A. (2008) · Stahlbau · doi:10.1002/stab.200810022 · Cited by 15
Experimental evaluation of magnetorheological dampers for semi-active tuned vibration absorbers
Koo, J., Ahmadian, M., & Setareh, M. (2003) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.483986 · Cited by 13
Woo, S.-S., Lee, S., & Chung, L. (2011) · Smart Structures and Systems · doi:10.12989/sss.2011.8.3.239 · Cited by 11 · cited 1×
“According to [32], the improvement, which depends on the magnitude of de-tuning, can be up to 45%.”
Semi-active TMD with piezoelectric friction dampers in floor vibration control
Jiang, G., & Hanagan, L. M. (2006) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.657754 · Cited by 11 · cited 1×
“Also variable damping is produced by STMD concepts with piezo-electrics or controllable friction devices as described in [20–22].”
TMD semi-active control with shape memory alloy
Li, Q. (2009) · Ha'erbin gongye daxue xuebao · Cited by 9
Research works printed but not linked: 21
- Qin L, 2009, Earthq. Eng. Eng. Vib., 29, 153
- Hazra B, 2010, Smart Mater. Struct., 19, 10.1088/0964-1726/19/4/049801 · doi:10.1088/0964-1726/19/4/049801
- 10.1002/stc.49 · doi:10.1002/stc.49
- Sun W-Q, 2009, Harbin Gongye Daxue Xuebao/J. Harbin Inst. Technol., 41, 164
- Xu Z B, 2011, Adv. Vib. Eng., 10, 229
- Li D, 2005, Proc. SPIE—Int. Soc. Opt. Eng., 5760, 501
- Chen Y-H, 2008, Struct. Eng. Mech., 30, 1, 10.1016/j.engstruct.2007.02.016 · doi:10.1016/j.engstruct.2007.02.016
- Jiang G, 2006, Proc. SPIE—Int. Soc. Opt. Eng., 6169
- Koo J H, 2003, Proc. SPIE—Int. Soc. Opt. Eng., 5052, 83
- Kang J, 2010, Struct. Eng. Mech., 36, 381, 10.12989/sem.2010.36.3.381 · doi:10.12989/sem.2010.36.3.381
- Sui L-l, 2006, J. Shenzhen Univ. Sci. Eng., 23, 291
- Weber F, 2011, Smart Mater. Struct., 20
- Albanese A M, 2003, Proc. SPIE—Int. Soc. Opt. Eng., 5052, 36
- Weber F, 2011, Smart Mater. Struct., 20
- 10.1177/1077546304032020 · DOI
- Arrigan J Pakrashi V Basu B Nagarajaiah S, 2009, Proc. IET Irish Signals and Systems Conf. (ISSC 2009), 6
- Weber F, 2010, Smart Mater. Struct., 19, 10.1088/0964-1726/19/4/045025 · doi:10.1088/0964-1726/19/4/045025
- Weber F, 2009, Smart Mater. Struct., 18, 10.1088/0964-1726/18/1/015005 · doi:10.1088/0964-1726/18/1/015005
- Wu B, 2011, Struct. Control Health Monit.
- Weber F, 2008, J. Struct. Eng. Mech., 30, 787, 10.12989/sem.2008.30.6.787 · doi:10.12989/sem.2008.30.6.787
- Maslanka M, Smart Mater. Struct.
Cited by
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Vibration Mechanisms and Controls of Long-Span Bridges: A Review
Fujino, Y., & Siringoringo, D. (2013) · Structural Engineering International · doi:10.2749/101686613x13439149156886 · Cited by 198
Semi-active vibration absorber based on real-time controlled MR damper
Weber, F. (2014) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2014.01.017 · Cited by 180
Self-citationDai, J., Xu, Z.-D., & Gai, P.-P. (2019) · Engineering Structures · doi:10.1016/j.engstruct.2019.109585 · Cited by 163
Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review
Rahimi, F., Aghayari, R., & Samali, B. (2020) · Civil Engineering Journal · doi:10.28991/cej-2020-03091571 · Cited by 138
Metadata
- Authors
- Weber, F., & Maślanka, M.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2012-04-24
- Volume
- 21
- Issue
- 5
- Pages
- 055011
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2112245266
- Cited by
- 158
- References
- 35
- FWCI
- 28.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.