Functional stimuli responsive hydrogel devices by self-folding
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
We describe a photolithographic approach to create functional stimuli responsive, self-folding, microscale hydrogel devices using thin, gradient cross-linked hinges and thick, fully cross-linked panels. The hydrogels are composed of poly ( N -isopropylacrylamide-co-acrylic acid) (pNIPAM-AAc) with reversible stimuli responsive properties just below physiological temperatures. We show that a variety of three-dimensional structures can be formed and reversibly actuated by temperature or pH. We experimentally characterized the swelling and mechanical properties of pNIPAM-AAc and developed a finite element model to rationalize self-folding and its variation with hinge thickness and swelling ratio. Finally, we highlight applications of this approach in the creation of functional devices such as self-folding polymeric micro-capsules, untethered micro-grippers and thermally steered micro-mirror systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Emerging applications of stimuli-responsive polymer materials
Stuart, M. A. C., Huck, W. T. S., Genzer, J., Müller, M., Ober, C., Stamm, M., Sukhorukov, G. B., Szleifer, I., Tsukruk, V. V., Urban, M., et al. (2010) · Nature Materials · doi:10.1038/nmat2614 · Cited by 5,707
Poly(N-isopropylacrylamide): experiment, theory and application
Schild, H. G. (1992) · Progress in Polymer Science · doi:10.1016/0079-6700(92)90023-r · Cited by 5,147
Thermodynamics of High Polymer Solutions
Flory, P. J. (1942) · The Journal of Chemical Physics · doi:10.1063/1.1723621 · Cited by 4,374
Statistical Mechanics of Cross-Linked Polymer Networks II. Swelling
Flory, P. J., & Rehner, J. (1943) · The Journal of Chemical Physics · doi:10.1063/1.1723792 · Cited by 3,865
Stimuli-reponsive polymers and their bioconjugates
GIL, E., & HUDSON, S. (2004) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.08.003 · Cited by 2,385
Solutions of Long Chain Compounds
Huggins, M. L. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750930 · Cited by 1,919
Stimuli responsive polymers for biomedical applications
Alarcón, C. D. L. H., Pennadam, S., & Alexander, C. (2005) · Chem. Soc. Rev. · doi:10.1039/b406727d · Cited by 1,690
(2006) · Advanced Materials · doi:10.1002/(issn)1521-4095 · Cited by 1,662
Tee, B. C.-K., Wang, C., Allen, R., & Bao, Z. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.192 · Cited by 1,419
Ilievski, F., Mazzeo, A. D., Shepherd, R. F., Chen, X., & Whitesides, G. M. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201006464 · Cited by 1,381
Graft copolymers that exhibit temperature-induced phase transitions over a wide range of pH
Chen, G., & Hoffman, A. S. (1995) · Nature · doi:10.1038/373049a0 · Cited by 1,219
Forterre, Y., Skotheim, J. M., Dumais, J., & Mahadevan, L. (2005) · Nature · doi:10.1038/nature03185 · Cited by 1,093
A theory of coupled diffusion and large deformation in polymeric gels
Hong, W., Zhao, X., Zhou, J., & Suo, Z. (2008) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2007.11.010 · Cited by 1,067 · cited 1×
“The polymer volume fraction is represented as φ= 1/ (1 + vc) [47], where v is the volume per solute molecule and c is the number of solute molecules per reference volume.”
BackgroundPhase transition in polymer gels induced by visible light
Suzuki, A., & Tanaka, T. (1990) · Nature · doi:10.1038/346345a0 · Cited by 1,035
Designing Responsive Buckled Surfaces by Halftone Gel Lithography
Kim, J., Hanna, J. A., Byun, M., Santangelo, C. D., & Hayward, R. C. (2012) · Science · doi:10.1126/science.1215309 · Cited by 883 · cited 3×
“We note that these films are thinner than the previously utilized pNIPAM self-folding structures which typically had thickness between 10 μm [33] and 225 μm [37].”
MethodResultVolume-phase transitions of ionized N-isopropylacrylamide gels
Hirotsu, S., Hirokawa, Y., & Tanaka, T. (1987) · The Journal of Chemical Physics · doi:10.1063/1.453267 · Cited by 856
Stimuli-responsive polymer gels
Ahn, S.-K., Kasi, R. M., Kim, S.-C., Sharma, N., & Zhou, Y. (2008) · Soft Matter · doi:10.1039/b714376a · Cited by 649
Shaping of Elastic Sheets by Prescription of Non-Euclidean Metrics
Klein, Y., Efrati, E., & Sharon, E. (2007) · Science · doi:10.1126/science.1135994 · Cited by 642
Maeda, S., Hara, Y., Sakai, T., Yoshida, R., & Hashimoto, S. (2007) · Advanced Materials · doi:10.1002/adma.200700625 · Cited by 640
Cheng, B., Jin, Y., Wang, R., Xu, P., Wu, X., Wang, N., Xu, H., & Guang, S. (2006) · Advanced Functional Materials · doi:10.1002/(issn)1616-3028 · Cited by 590
Synthesis and Application of Modulated Polymer Gels
Hu, Z., Zhang, X., & Li, Y. (1995) · Science · doi:10.1126/science.269.5223.525 · Cited by 544
Zhang, X., Pint, C. L., Lee, M. H., Schubert, B. E., Jamshidi, A., Takei, K., Ko, H., Gillies, A., Bardhan, R., Urban, J. J., et al. (2011) · Nano Letters · doi:10.1021/nl201503e · Cited by 529
Biomimetic Hydrogel‐Based Actuating Systems
Ionov, L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203692 · Cited by 469
Stretchable, elastic materials and devices for solar energy conversion
Lipomi, D. J., & Bao, Z. (2011) · Energy & Environmental Science · doi:10.1039/c1ee01881g · Cited by 392
Self-folding all-polymer thermoresponsive microcapsules
Stoychev, G., Puretskiy, N., & Ionov, L. (2011) · Soft Matter · doi:10.1039/c1sm05109a · Cited by 348
Reversible phase transitions in polymer gels induced by radiation forces
Juodkazis, S., Mukai, N., Wakaki, R., Yamaguchi, A., Matsuo, S., & Misawa, H. (2000) · Nature · doi:10.1038/35041522 · Cited by 346
An Integrated Microrobotic Platform for On‐Demand, Targeted Therapeutic Interventions
Fusco, S., Sakar, M. S., Kennedy, S., Peters, C., Bottani, R., Starsich, F., Mao, A., Sotiriou, G. A., Pané, S., Pratsinis, S. E., et al. (2014) · Advanced Materials · doi:10.1002/adma.201304098 · Cited by 321
Chester, S. A., & Anand, L. (2011) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2011.07.005 · Cited by 317
Self-folding polymeric containers for encapsulation and delivery of drugs
Fernandes, R., & Gracias, D. H. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.02.012 · Cited by 285
Self-citationKim, J., Yoon, J., & Hayward, R. C. (2010) · Nature Materials · doi:10.1038/nmat2606 · Cited by 277
Fujimoto, K. L., Ma, Z., Nelson, D. M., Hashizume, R., Guan, J., Tobita, K., & Wagner, W. R. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.055 · Cited by 269
Stimuli‐Responsive Theragrippers for Chemomechanical Controlled Release
Malachowski, K., Breger, J., Kwag, H. R., Wang, M. O., Fisher, J. P., Selaru, F. M., & Gracias, D. H. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201311047 · Cited by 257
Self-citationA Hybrid Combining Hard and Soft Robots
Stokes, A. A., Shepherd, R. F., Morin, S. A., Ilievski, F., & Whitesides, G. M. (2014) · Soft Robotics · doi:10.1089/soro.2013.0002 · Cited by 251
Differentially photo-crosslinked polymers enable self-assembling microfluidics
Jamal, M., Zarafshar, A. M., & Gracias, D. H. (2011) · Nature Communications · doi:10.1038/ncomms1531 · Cited by 249 · cited 1×
“In addition to being thinner, the flexible hinge also has a cross-link gradient [46] while the interconnecting panels are fully cross-linked and thicker.”
BackgroundSelf-citationPhotolithographically patterned smart hydrogel based bilayer actuators
Bassik, N., Abebe, B. T., Laflin, K. E., & Gracias, D. H. (2010) · Polymer · doi:10.1016/j.polymer.2010.10.035 · Cited by 242
Self-citationThermally responsive rolling of thin gel strips with discrete variations in swelling
Kim, J., Hanna, J. A., Hayward, R. C., & Santangelo, C. D. (2012) · Soft Matter · doi:10.1039/c2sm06681e · Cited by 214 · cited 1×
“Kim et al demonstrated buckled gel surfaces using differential swelling of pNIPAM hydrogels using half-tone lithography [33, 34].”
MethodStimuli responsive self-folding using thin polymer films
Gracias, D. H. (2013) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2012.10.003 · Cited by 183
Self-citationZhang, J., Chu, L.-Y., Li, Y.-K., & Lee, Y. M. (2007) · Polymer · doi:10.1016/j.polymer.2007.01.055 · Cited by 182
Fabrication of Micrometer-Scale, Patterned Polyhedra by Self-Assembly
Gracias, D. H., Kavthekar, V., Love, J. C., Paul, K. E., & Whitesides, G. M. (2002) · Advanced Materials · doi:10.1002/1521-4095(20020205)14:3<235::aid-adma235>3.0.co;2-b · Cited by 171
Self-citationSelf-folding micropatterned polymeric containers
Azam, A., Laflin, K. E., Jamal, M., Fernandes, R., & Gracias, D. H. (2011) · Biomedical Microdevices · doi:10.1007/s10544-010-9470-x · Cited by 169
Self-citationSurface Tension-Driven Self-Folding Polyhedra
Leong, T. G., Lester, P. A., Koh, T. L., Call, E. K., & Gracias, D. H. (2007) · Langmuir · doi:10.1021/la700913m · Cited by 165
Self-citationZakharchenko, S., Puretskiy, N., Stoychev, G., Stamm, M., & Ionov, L. (2010) · Soft Matter · doi:10.1039/c0sm00088d · Cited by 153
Beam-steering micromirrors for large optical cross-connects
Aksyuk, V., Pardo, F., Carr, D. W., Greywall, D. S., Chan, H. B., Simon, M. E., Gasparyan, A., Shea, H. R., Lifton, V. A., Bolle, C., et al. (2003) · Journal of Lightwave Technology · doi:10.1109/jlt.2003.811792 · Cited by 138
Fujigaya, T., Morimoto, T., Niidome, Y., & Nakashima, N. (2008) · Advanced Materials · doi:10.1002/adma.200800494 · Cited by 137
Unconventional applications of wire bonding create opportunities for microsystem integration
Fischer, A. C., Korvink, J. G., Roxhed, N., Stemme, G., Wallrabe, U., & Niklaus, F. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/8/083001 · Cited by 118
Leaf Closure in the Venus Flytrap: An Acid Growth Response
Williams, S. E., & Bennett, A. B. (1982) · Science · doi:10.1126/science.218.4577.1120 · Cited by 89
Zhang, Y., & Yarin, A. L. (2009) · Journal of Materials Chemistry · doi:10.1039/b902000d · Cited by 67
Thermonastic leaf movements: a synthesis of research with Rhododendron
Nilsen, E. T. (1992) · Botanical Journal of the Linnean Society · doi:10.1111/j.1095-8339.1992.tb00291.x · Cited by 42
Cited by
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Multimaterial 4D Printing with Tailorable Shape Memory Polymers
Ge, Q., Sakhaei, A. H., Lee, H., Dunn, C. K., Fang, N. X., & Dunn, M. L. (2016) · Scientific Reports · doi:10.1038/srep31110 · Cited by 1,160
Poly(N-isopropylacrylamide)-based smart hydrogels: Design, properties and applications
Tang, L., Wang, L., Yang, X., Feng, Y., Li, Y., & Feng, W. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100702 · Cited by 866
Mechanical properties of PNIPAM based hydrogels: A review
Haq, M. A., Su, Y., & Wang, D. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.09.081 · Cited by 695
Self-Folding Thermo-Magnetically Responsive Soft Microgrippers
Breger, J. C., Yoon, C., Xiao, R., Kwag, H. R., Wang, M. O., Fisher, J. P., Nguyen, T. D., & Gracias, D. H. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/am508621s · Cited by 655
Self-citation
Metadata
- Authors
- Yoon, C., Xiao, R., Park, J., Cha, J., Nguyen, T. D., & Gracias, D. H.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2014-08-11
- Volume
- 23
- Issue
- 9
- Pages
- 094008
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2053958022
- Cited by
- 171
- References
- 48
- FWCI
- 17.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.