Characterization of textile electrodes and conductors using standardized measurement setups
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Textile electrodes and conductors are being developed and used in different monitoring scenarios, such as ECG or bioimpedance spectroscopy measurements. Compared to standard materials, conductive textile materials offer improved wearing comfort and enable long-term measurements. Unfortunately, the development and investigation of such materials often suffers from the non-reproducibility of the test scenarios. For example, the materials are generally tested on human skin which is difficult since the properties of human skin differ for each person and can change within hours. This study presents two test setups which offer reproducible measurement procedures for the systematic analysis of textile electrodes and conductors. The electrode test setup was designed with a special skin dummy which allows investigation of not only the electrical properties of textile electrodes but also the contact behavior between electrode and skin. Using both test setups, eight textile electrodes and five textile conductors were analyzed and compared.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270 · cited 1×
“Such conductivity is equivalent to the conductance of wet skin tissue at 10 kHz (see Gabriel et al 1996).”
BackgroundMedical instrumentation: Application and design
Undar, A., Calhoon, J. H., & Rocha, A. D. (1997) · Control Engineering Practice · doi:10.1016/s0967-0661(97)90030-7 · Cited by 1,015
A direct comparison of wet, dry and insulating bioelectric recording electrodes
Searle, A., & Kirkup, L. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/307 · Cited by 725 · cited 1×
“Searle and Kirkup (2000) and Rattfaelt et al (2007) investigated the properties of different textile electrodes regarding their impedance, polarization and performance despite motion artifacts, and Riistama and Lekkala (2006) recently compared the noise characteristics of several textile electrodes.”
BackgroundELECTRODE POLARIZATION IMPEDANCE AND MEASUREMENTS IN BIOLOGICAL MATERIALS*
Schwan, H. P. (1968) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1968.tb20349.x · Cited by 368 · cited 1×
“The electrode potential is time independent, assuming that the electrode–skin system is stabilized (Schwan 1968).”
BackgroundPerformance Evaluation of Sensing Fabrics for Monitoring Physiological and Biomechanical Variables
Scilingo, E. P., Gemignani, A., Paradiso, R., Taccini, N., Ghelarducci, B., & DeRossi, D. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854506 · Cited by 247
Electrical characterization of textile transmission lines
Cottet, D., Grzyb, J., Kirstein, T., & Troster, G. (2003) · IEEE Transactions on Advanced Packaging · doi:10.1109/tadvp.2003.817329 · Cited by 219
Lymberis, A., & Olsson, S. (2003) · Telemedicine Journal and e-Health · doi:10.1089/153056203772744716 · Cited by 130 · cited 2×
“unobstrusively and reliably monitor the vital parameters of a person (Lymberis and Olsson 2003).”
BackgroundInfluentialElectrical characteristics of conductive yarns and textile electrodes for medical applications
Rattfält, L., Lindén, M., Hult, P., Berglin, L., & Ask, P. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0266-y · Cited by 123 · cited 1×
“Searle and Kirkup (2000) and Rattfaelt et al (2007) investigated the properties of different textile electrodes regarding their impedance, polarization and performance despite motion artifacts, and Riistama and Lekkala (2006) recently compared the noise characteristics of several textile electrodes.”
BackgroundPrinciples of Applied Biomedical Instrumentation
Smale, A. J. (1969) · Electronics and Power · doi:10.1049/ep.1969.0230 · Cited by 102
Dry electrodes for monitoring of vital signs in functional textiles
Mühlsteff, J., & Such, O. (2005) · doi:10.1109/iembs.2004.1403645 · Cited by 66
Cited by
Flexible Organic Electronics in Biology: Materials and Devices
Liao, C., Zhang, M., Yao, M. Y., Hua, T., Li, L., & Yan, F. (2015) · Advanced Materials · doi:10.1002/adma.201402625 · Cited by 438
Review of Flexible Temperature Sensing Networks for Wearable Physiological Monitoring
Li, Q., Zhang, L., Tao, X., & Ding, X. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601371 · Cited by 354
Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement
Lin, C.-T., Liao, L.-D., Liu, Y.-H., Wang, I.-J., Lin, B.-S., & Chang, J.-Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2102353 · Cited by 336
Wearable and Flexible Textile Electrodes for Biopotential Signal Monitoring: A review
Acar, G., Ozturk, O., Golparvar, A. J., Elboshra, T. A., Böhringer, K., & Yapici, M. K. (2019) · Electronics · doi:10.3390/electronics8050479 · Cited by 315
Cognition in action: imaging brain/body dynamics in mobile humans
Gramann, K., Gwin, J. T., Ferris, D. P., Oie, K., Jung, T.-P., Lin, C.-T., Liao, L.-D., & Makeig, S. (2011) · Reviews in the Neurosciences · doi:10.1515/rns.2011.047 · Cited by 302
Fabric-Based Wearable Dry Electrodes for Body Surface Biopotential Recording
Yokus, M. A., & Jur, J. S. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2462312 · Cited by 214
“A similar inverse pressure and impedance relation is observed in [7].”
BackgroundLi, G., Wang, S., & Duan, Y. Y. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.08.155 · Cited by 203
Fully Textile, PEDOT:PSS Based Electrodes for Wearable ECG Monitoring Systems
Pani, D., Dessi, A., Saenz-Cogollo, J. F., Barabino, G., Fraboni, B., & Bonfiglio, A. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2465936 · Cited by 192
“textile electrodes reveal a strong capacitive behavior mitigated by physiological (or artificial) skin wetting, resulting in a parallel conductive path [34].”
BackgroundInfluentialLiao, L.-D., Wang, I.-J., Chen, S.-F., Chang, J.-Y., & Lin, C.-T. (2011) · Sensors · doi:10.3390/s110605819 · Cited by 181
“As with conventional wet electrodes, the proposed dry EEG sensor exhibits conductivity only because of its electrically conductive probes [34].”
BackgroundReview of semi-dry electrodes for EEG recording
Li, G.-L., Wu, J.-T., Xia, Y.-H., He, Q.-G., & Jin, H.-G. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abbd50 · Cited by 178
“Cs represents the capacitive coupling between the conductive metal electrode and the underlying conductive tissues, incorporating the stratum corneum dielectric properties and its thinness; Rs represents the resistance of the channels, sweat glands, and hair follicles in the layered structured skin; Rsub represents th…”
MethodAngelucci, A., Cavicchioli, M., Cintorrino, I., Lauricella, G., Rossi, C., Strati, S., & Aliverti, A. (2021) · Sensors · doi:10.3390/s21030814 · Cited by 170
“The models of the skin and electrode-electrolyte interface [41] are based on the combination of equivalent circuits for the electrode-electrolyte interface [42] and equivalent circuits of the skin [43].”
Biosensor Technologies for Augmented Brain–Computer Interfaces in the Next Decades
Liao, L.-D., Lin, C.-T., McDowell, K., Wickenden, A. E., Gramann, K., Jung, T.-P., Ko, L.-W., & Chang, J.-Y. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2184829 · Cited by 169
Nanomaterial-Enabled Dry Electrodes for Electrophysiological Sensing: A Review
Yao, S., & Zhu, Y. (2016) · JOM · doi:10.1007/s11837-016-1818-0 · Cited by 166
Fully Implantable Multi-Channel Measurement System for Acquisition of Muscle Activity
Lewis, S., Russold, M., Dietl, H., Ruff, R., Audi, J. M. C., Hoffmann, K.-P., Abu-Saleh, L., Schroeder, D., Krautschneider, W. H., Westendorff, S., et al. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2253992 · Cited by 52
“More comfortable solutions for longterm monitoring might be flexible dry electrodes [11], textile electrodes that can be directly integrated into clothes [12] or capacitive electrodes that are separated from the skin by a dielectric layer and are capable of measuring sEMG through thin layers of garment [13].”
Background
Metadata
- Authors
- Beckmann, L., Neuhaus, C., Medrano, G., Jungbecker, N., Walter, M., Gries, T., & Leonhardt, S.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2010-01-20
- Volume
- 31
- Issue
- 2
- Pages
- 233-247
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1994883634
- Cited by
- 192
- References
- 14
- FWCI
- 11.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.