CoChat

Improvement of signal-to-interference ratio and signal-to-noise ratio in nerve cuff electrode systems

Chu, Jun-Uk, Song, Kang-Il, Han, Sungmin, Lee, Soo Hyun, Kim, Jinseok, Kang, Ji Yoon, Hwang, Dosik, Suh, Jun-Kyo Francis, Choi, Kuiwon, Youn, Inchan · 2012 · Physiological Measurement
Cited by 47

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Cuff electrodes are effective for chronic electroneurogram (ENG) recording while minimizing nerve damage. However, the ENG signals are usually contaminated by electromyogram (EMG) activity from the surrounding muscles, stimulus artifacts produced by the electrical stimulation and noise generated in the first stage of the neural signal amplifier. This paper proposed a new cuff electrode to reduce the interference from EMG signals and stimulus artifacts. As a result, when an additional middle electrode was placed at the center of the cuff electrode, a significant improvement in the signal-to-interference ratio was achieved at 11% for the EMG signals and 12% for the stimulus artifacts when compared to a conventional tripolar cuff. Furthermore, a new low-noise amplifier was proposed to improve the signal-to-noise ratio. The circuit was designed based on a noise analysis to minimize the noise, and the results show that the total noise of the amplifier was below 1 μV for a cuff impedance of 1 kΩ and a frequency bandwidth of 300 to 5000 Hz.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/33/6/943

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 47

Metadata

Authors
Chu, J.-U., Song, K.-I., Han, S., Lee, S. H., Kim, J., Kang, J. Y., Hwang, D., Suh, J.-K. F., Choi, K., & Youn, I.
Venue
Physiological Measurement
Published
2012-05-03
Volume
33
Issue
6
Pages
943-967
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2024049244
Cited by
47
References
5
FWCI
1.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improvement of signal-to-interference ratio and signal-to-noise ratio in nerve cuff electrode systems. https://app.cochat.ai/papers/10.1088/0967-3334/33/6/943
The paper
Chu, J.-U., Song, K.-I., Han, S., Lee, S. H., Kim, J., Kang, J. Y., Hwang, D., Suh, J.-K. F., Choi, K., & Youn, I. (2012). Improvement of signal-to-interference ratio and signal-to-noise ratio in nerve cuff electrode systems. Physiological Measurement. https://doi.org/10.1088/0967-3334/33/6/943

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.