CoChat

Adaptive self-healing electronic epineurium for chronic bidirectional neural interfaces

Open access

The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.

Abstract

Realizing a clinical-grade electronic medicine for peripheral nerve disorders is challenging owing to the lack of rational material design that mimics the dynamic mechanical nature of peripheral nerves. Electronic medicine should be soft and stretchable, to feasibly allow autonomous mechanical nerve adaptation. Herein, we report a new type of neural interface platform, an adaptive self-healing electronic epineurium (A-SEE), which can form compressive stress-free and strain-insensitive electronics-nerve interfaces and enable facile biofluid-resistant self-locking owing to dynamic stress relaxation and water-proof self-bonding properties of intrinsically stretchable and self-healable insulating/conducting materials, respectively. Specifically, the A-SEE does not need to be sutured or glued when implanted, thereby significantly reducing complexity and the operation time of microneurosurgery. In addition, the autonomous mechanical adaptability of the A-SEE to peripheral nerves can significantly reduce the mechanical mismatch at electronics-nerve interfaces, which minimizes nerve compression-induced immune responses and device failure. Though a small amount of Ag leaked from the A-SEE is observed in vivo (17.03 ppm after 32 weeks of implantation), we successfully achieved a bidirectional neural signal recording and stimulation in a rat sciatic nerve model for 14 weeks. In view of our materials strategy and in vivo feasibility, the mechanically adaptive self-healing neural interface would be considered a new implantable platform for a wide range application of electronic medicine for neurological disorders in the human nervous system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-020-18025-3

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 A-SEE and its nerve tissue modulus adaptability. Schematic (a) and photograph (b) show the A-SEE interfaced with a rat sciatic nerve. c Time-dependent normalized tensile stress relaxation of different materials at 30% strain. d Temperature dependence of stress relaxation in PDMS and A-SEE. e Schematic and H&E stained image of rat sciatic nerve tissue showing the effect of tissue modulus-adaptability of A-SEE on the nerve. Representative image from n = 3 biologically independent samples. FEA results showing the time-dependent distributions of compressive stress applied to the nerve interfaced with PDMS (f) and SHP (g). Confocal fluorescence (h) and TUNEL staining (i) images of sciatic nerve cross-sections. Representative images from n = 3 biologically independent samples. j, Thickness of fibrotic tissue formed around the nerve tissues interfaced without (week 0) and with PDMS or SHP for 1 and 6 weeks. Statistical analysis was performed using one-way analysis of variance (ANOVA) with Tukey’s multiple comparison test (n = 3 independent samples for each group, P(Week 1) = 0.0097, P(Week 6) = 0.0104, *P < 0.05). Top inset shows H&E stained images showing the fibrotic tissue formed around the nerve tissue. Representative images from n = 3 biologically independent samples. k SNR of sensory neural signals recorded by the A-SEE for 6 weeks (n = 5 independent animals). In, j, k, all data are represented as mean ± S.D. Source data are provided as a Source Data file.
Fig. 1 A-SEE and its nerve tissue modulus adaptability. Schematic (a) and photograph (b) show the A-SEE interfaced with a rat sciatic nerve. c Time-dependent normalized tensile stress relaxation of different materials at 30% strain. d Temperature dependence of stress relaxation in PDMS and A-SEE. e Schematic and H&E stained image of rat sciatic nerve tissue showing the effect of tissue modulus-adaptability of A-SEE on the nerve. Representative image from n = 3 biologically independent samples. FEA results showing the time-dependent distributions of compressive stress applied to the nerve interfaced with PDMS (f) and SHP (g). Confocal fluorescence (h) and TUNEL staining (i) images of sciatic nerve cross-sections. Representative images from n = 3 biologically independent samples. j, Thickness of fibrotic tissue formed around the nerve tissues interfaced without (week 0) and with PDMS or SHP for 1 and 6 weeks. Statistical analysis was performed using one-way analysis of variance (ANOVA) with Tukey’s multiple comparison test (n = 3 independent samples for each group, P(Week 1) = 0.0097, P(Week 6) = 0.0104, *P < 0.05). Top inset shows H&E stained images showing the fibrotic tissue formed around the nerve tissue. Representative images from n = 3 biologically independent samples. k SNR of sensory neural signals recorded by the A-SEE for 6 weeks (n = 5 independent animals). In, j, k, all data are represented as mean ± S.D. Source data are provided as a Source Data file.CC BY · PubMed Central
Fig. 2 AuNM-Ag flake-SHP composite as a nerve interfacing electrode for the A-SEE. a Photograph of AuNM-Ag flake-SHP composite, a schematic showing the transfer-printing of the AuNM onto the Ag flake-SHP composite, and an SEM image showing conformal interfaces between the transferred AuNM and the Ag flake-SHP composite. Representative images from n = 5 independent samples. b Cell viability test after 7 days culture. Data are represented as mean ± S.D. Statistical analysis was performed using one-way ANOVA with Tukey’s multiple comparison test (n = 104 cells/mL examined over five independent experiments, P(C2C12) = 0.0001, P(Raw 264.7) = 0.0004, ***P < 0.001). c Resistance-strain characteristics of the A-SEE in pristine and self-healed states. (Inset) Resistance changes in the A-SEE during a cyclic stretching test at 50% strain for 1000 cycles. d Resistance changes in the A-SEE in bending tests that mimic nerve interfacing. (Inset) Photograph showing the A-SEE bent to a bending radius (0.5 mm) of a rat sciatic nerve. e Impedance stability of the A-SEE immersed in PBS solution for 10 days. (Inset) Impedance-frequency characteristics of the A-SEE. f Strain-dependent impedance of the A-SEE at different frequencies. g Cyclic voltammetry curves of the A-SEE at 0 and 100% strain (n = 20). Source data are provided as a Source Data file.
Fig. 2 AuNM-Ag flake-SHP composite as a nerve interfacing electrode for the A-SEE. a Photograph of AuNM-Ag flake-SHP composite, a schematic showing the transfer-printing of the AuNM onto the Ag flake-SHP composite, and an SEM image showing conformal interfaces between the transferred AuNM and the Ag flake-SHP composite. Representative images from n = 5 independent samples. b Cell viability test after 7 days culture. Data are represented as mean ± S.D. Statistical analysis was performed using one-way ANOVA with Tukey’s multiple comparison test (n = 104 cells/mL examined over five independent experiments, P(C2C12) = 0.0001, P(Raw 264.7) = 0.0004, ***P < 0.001). c Resistance-strain characteristics of the A-SEE in pristine and self-healed states. (Inset) Resistance changes in the A-SEE during a cyclic stretching test at 50% strain for 1000 cycles. d Resistance changes in the A-SEE in bending tests that mimic nerve interfacing. (Inset) Photograph showing the A-SEE bent to a bending radius (0.5 mm) of a rat sciatic nerve. e Impedance stability of the A-SEE immersed in PBS solution for 10 days. (Inset) Impedance-frequency characteristics of the A-SEE. f Strain-dependent impedance of the A-SEE at different frequencies. g Cyclic voltammetry curves of the A-SEE at 0 and 100% strain (n = 20). Source data are provided as a Source Data file.CC BY · PubMed Central
Fig. 3 Chronic neural recording and stimulation using the A-SEE. a Schematic of sensory neural signal recording during mechanical stimulation. b Long-term neural signal recordings with strong and weak mechanical stimuli. c SNR of neural signals with strong and weak stimuli at 0, 3, and 6 weeks of implantation (n = 5 independent experiments). The centerline represents the median, the bounds of the box represent the upper and lower quartiles, the whiskers represent minimum and maximum values, and the hollow circle shows dot plots. Error bars represent S.D. d Sequential images for hind limb movement induced by electrical stimulation (80 μA, 100 Hz) at 7 weeks of implantation. e Plot of normalized muscle force as a function of stimulation frequency. The parameters involved in neural stimulation are pulse width (PW, 0.25 ms), biphasic pulse amplitude (PA, 80 μA), stimulation period (0.5 s), repetition stimulation periods (SP, 5, 10, 20, 50, and 100 Hz), and stimulation current (1.14 μC/cm2). f Changes in SNR performance before and after electrical stimulation (stimulation pulses: 100,000). Data are represented as mean ± S.D. Statistical analysis was performed using one-way ANOVA with Tukey’s multiple comparison test (n = 14 independent experiments, P = 0.7795, NS (not significant) P > 0.05). g Synchronous neural signal and joint position recording of treadmill gait after 7 weeks of implantation. Real-time analysis for joint position and knee/ankle angle changes of a live rat without (h) and with (i) electrical stimulation after 7 weeks of implantation. Source data are provided as a Source Data file.
Fig. 3 Chronic neural recording and stimulation using the A-SEE. a Schematic of sensory neural signal recording during mechanical stimulation. b Long-term neural signal recordings with strong and weak mechanical stimuli. c SNR of neural signals with strong and weak stimuli at 0, 3, and 6 weeks of implantation (n = 5 independent experiments). The centerline represents the median, the bounds of the box represent the upper and lower quartiles, the whiskers represent minimum and maximum values, and the hollow circle shows dot plots. Error bars represent S.D. d Sequential images for hind limb movement induced by electrical stimulation (80 μA, 100 Hz) at 7 weeks of implantation. e Plot of normalized muscle force as a function of stimulation frequency. The parameters involved in neural stimulation are pulse width (PW, 0.25 ms), biphasic pulse amplitude (PA, 80 μA), stimulation period (0.5 s), repetition stimulation periods (SP, 5, 10, 20, 50, and 100 Hz), and stimulation current (1.14 μC/cm2). f Changes in SNR performance before and after electrical stimulation (stimulation pulses: 100,000). Data are represented as mean ± S.D. Statistical analysis was performed using one-way ANOVA with Tukey’s multiple comparison test (n = 14 independent experiments, P = 0.7795, NS (not significant) P > 0.05). g Synchronous neural signal and joint position recording of treadmill gait after 7 weeks of implantation. Real-time analysis for joint position and knee/ankle angle changes of a live rat without (h) and with (i) electrical stimulation after 7 weeks of implantation. Source data are provided as a Source Data file.CC BY · PubMed Central
Fig. 4 Nerve-to-nerve interface. a Experimental set-up and flow diagram of nerve-to-nerve interfacing demonstration. b Transmission of neural signals recorded from one side of sciatic nerve to the other through nerve-to-nerve interface.
Fig. 4 Nerve-to-nerve interface. a Experimental set-up and flow diagram of nerve-to-nerve interfacing demonstration. b Transmission of neural signals recorded from one side of sciatic nerve to the other through nerve-to-nerve interface.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 50 references

Research works printed but not linked: 1

  1. Grill, W. M. & Mortimer, J. T. Neural and connective tissue response to long-term implantation of multiple contact nerve cuff electrodes. J. Biomed. Mater. Res. 50, 215–226 (2000). · doi:10.1002/(sici)1097-4636(200005)50:2<215::aid-jbm17>3.0.co;2-a

Cited by

See all 120

Metadata

Authors
Song, K.-I., Seo, H., Seong, D., Kim, S., Yu, K. J., Kim, Y.-C., Kim, J., Kwon, S. J., Han, H.-S., Youn, I., Lee, H., & Son, D.
Affiliations
  • Daegu-Gyeongbuk Medical Innovation Foundation (KR)
  • Korea Institute of Science and Technology (KR)
  • Sungkyunkwan University (KR)
  • Yonsei University (KR)
Corresponding author
  • Youn, Inchan
  • Lee, Hyojin
  • Son, Donghee
Venue
Nature Communications
Published
2020-08-21
Volume
11
Issue
1
Pages
4195-4195
ISSN
2041-1723 (ISSN-L)
OpenAlex
W3080891263
Cited by
120
References
50
Citations by year
2026: 16 · 2025: 23 · 2024: 29 · 2023: 16 · 2022: 15 · 2021: 21
FWCI
5.95
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • National Research Foundation
  • Korea Institute of Science and Technology (2020R1C1C1005567, 2E29680, 2E29300, 2E30341)
  • National Research Foundation of Korea (IITP-2020-0-01821, 2020R1C1C1005567, CAP-18-01-KIST, 2E30341)
  • Ministry of Science and ICT, South Korea (2020-0-01821, CAP-18-01-KIST, IITP-2020-0-01821, 2E30341, 2020R1C1C1005567)
  • Institute for Information and Communications Technology Promotion (IITP-2020-0-01821, 2020-0-01821)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
self-healing materials, stretchable electronics, peripheral nerve interfaces, implantable neural interfaces, mechanical mismatch, stress relaxation, sciatic nerve, peripheral nerve disorders
MeSH terms
Wearable Electronic Devices, Animals, Biomedical Engineering, Central Nervous System, Electronics, Medical, Gold, Humans, Male, Materials Testing, Nerve Tissue, Neurosurgery, Peripheral Nerves, Polymers, Sciatic Nerve, Prostheses and Implants, Models, Animal, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adaptive self-healing electronic epineurium for chronic bidirectional neural interfaces. https://app.cochat.ai/papers/10.1038/s41467-020-18025-3
The paper
Song, K.-I., Seo, H., Seong, D., Kim, S., Yu, K. J., Kim, Y.-C., Kim, J., Kwon, S. J., Han, H.-S., Youn, I., Lee, H., & Son, D. (2020). Adaptive self-healing electronic epineurium for chronic bidirectional neural interfaces. Nature Communications. https://doi.org/10.1038/s41467-020-18025-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.