The development of a novel apparatus to measure the emissivity of high-roughness materials at 82 K
Abstract
The emissivity of a material changes with temperature. The knowledge of emissivity plays an important role in the estimation of radiation heat load in cryogenic systems. As the emissivity values of different materials at cryogenic temperatures are scarcely available in the literature, room-temperature emissivity values have been extensively used to estimate the radiation heat load in cryogenic systems. This may lead to a significant deviation between the predicted and actual radiation properties at cryogenic temperatures. Therefore, in the present work, an apparatus is developed based on a calorimetric technique for measuring the emissivity of an opaque material around 82 K. The novelties of the apparatus are its compact size, ease of sample handling, shorter time required to reach thermal equilibrium and, most importantly, capacity to measure the emissivity of a sample of high roughness. To understand the effectiveness of low and high emissivity-coated heat radiators for the system, a theoretical and an experimental approach has been followed. It is found that the high-emissivity heat radiator leads to a significant reduction in the time required to reach thermal equilibrium compared to a low-emissivity heat radiator. To verify and validate this setup, the emissivities of Aeroglaze Z306 (high emissivity) and Cu (low emissivity) are measured and compared with the values reported in the literature. Finally, this work has been extended to measure emissivity at cryogenic temperature for the first time for PU1, SG121FD and indigenously developed novel materials, such as black paints, adhesive and activated charcoals of different granule sizes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Dewasi et al. showed that the use of high-emissivity radiators significantly shortened thermal equilibration times and improved overall testing efficiency.
“It was shown that the use of high-emissivity radiators significantly shortened thermal equilibration times and improved overall testing efficiency.”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [53]
The radiometric method avoids complex thermal process inversion and thus offers significantly faster testing speeds.
“This method avoids the need for complex thermal process inversion and thus offers significantly faster testing speeds [53].”
From Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review (2026) · cites this paper as [53]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 30
- Musilova, 2005, Low temperature radiative properties of materials used in cryogenics, Cryogenics, 45, 529, 10.1016/j.cryogenics.2004.11.010 · DOI · Paper page
- Fu, 2014, Research on surface modification and infrared emissivity of In2O3: w thin films, Thin Solid Films, 570, 68, 10.1016/j.tsf.2014.09.009 · DOI
- JET Contributors, 2017, The emissivity of W coatings deposited on carbon materials for fusion applications, Fusion Eng. Des., 114, 192, 10.1016/j.fusengdes.2016.12.015 · DOI
- Huang, 2023, Compatibility of low thermal conductivity and high infrared emissivity of plasma-sprayed Sm2Hf2O7 and Pr2Hf2O7 coatings, Surf. Coat. Technol., 457, 10.1016/j.surfcoat.2023.129312 · DOI
- Zhang, 2022, Ca-Mn co-doping LaCrO3 coating with high emissivity and good mechanical property for enhancing high-temperature radiant heat dissipation, J. Eur. Ceram. Soc., 42, 7288, 10.1016/j.jeurceramsoc.2022.08.033 · DOI
- Wu, 2016, A new high emissivity coating on Ni-based superalloy substrate, Rare Met. Mater. Eng., 45, 588, 10.1016/S1875-5372(16)30077-7 · DOI
- Zhang, 2022, A review of devices and methods for measuring thermal emissivity at cryogenic temperatures, IOP Conf. Ser.: Earth Environ. Sci., 1241, 10.1088/1757-899X/1241/1/012050 · DOI · Paper page
- Duckworth, 2006, Measurement of the emissivity of clean and contaminated silver plated copper surfaces at cryogenic temperatures, AIP Conf. Proc., 824, 61, 10.1063/1.2192334 · DOI · Paper page
- Kim, 2014, Emissivity measurement of coated copper and aluminum samples at 80 K, AIP Conf. Proc., 1573, 500, 10.1063/1.4860742 · DOI
- Gangradey, 2022, Design and development of a liquid nitrogen cooled test cryopump for application in steady-state superconducting Tokamak-1, Vacuum, 200, 10.1016/j.vacuum.2022.110986 · DOI
- Mukherjee, 2022, Design and development of LN2 cooled cryopump for application in high heat flux test facility, Fusion Eng. Des., 184, 10.1016/j.fusengdes.2022.113315 · DOI
- ITER Cryostat Team, 2011, ITER Cryostat—an overview and design progress, Fusion Eng. Des., 86, 1924, 10.1016/j.fusengdes.2011.01.037 · DOI
- Sarkar, 2006, Cryogenic system of steady state superconducting Tokamak SST-1: operational experience and controls, Fusion Eng. Des., 81, 2633, 10.1016/j.fusengdes.2006.07.020 · DOI
- Homan, 2010, The liquid nitrogen system for chamber A: a change from original forced flow design to a natural flow (Thermo siphon) system, AIP Conf. Proc., 1218, 207, 10.1063/1.3422355 · DOI
- Frolec, 2019, A database of metallic materials emissivities and absorptivities for cryogenics, Cryogenics, 97, 85, 10.1016/j.cryogenics.2018.12.003 · DOI · Paper page
- Gupta, 2020, Design and analysis of liquid nitrogen cooled sorption cryopump for SST-1 Tokamak, Fusion Eng. Des., 159, 10.1016/j.fusengdes.2020.111757 · DOI
- Mukherjee, 2021, Nitrogen and water vapor pumping study on a 400 mm opening LN2 cooled sorption cryopump, Vacuum, 184, 10.1016/j.vacuum.2020.109883 · DOI
- Gupta, 2022, Performance testing of the liquid nitrogen cooled sorption cryopump for application in SST-1 Tokamak, Fusion Eng. Des., 181, 10.1016/j.fusengdes.2022.113212 · DOI
- Gupta, 2020, A 2020 Thermo-structural analysis of SST-1 cryopump, Cryogenics, 110, 10.1016/j.cryogenics.2020.103132 · DOI
- Jo, 2017, Spectral emissivity of oxidized and roughened metal surfaces, Int. J. Heat Mass Transfer, 115, 1065, 10.1016/j.ijheatmasstransfer.2017.08.103 · DOI
- Honnerová, 2017, Method for emissivity measurement of semitransparent coatings at ambient temperature, Sci. Rep., 7, 1386, 10.1038/s41598-017-01574-x · DOI
- Králík, 2016, Method for measurement of emissivity and absorptivity of highly reflective surfaces from 20 K to room temperatures, Metrologia, 53, 743, 10.1088/0026-1394/53/2/743 · DOI · Paper page
- Hatti, 2018, Development of an experimental setup for emissivity measurement at cryogenic temperatures, Int. J. Eng. Dev. Res., 6, 218
- Shafi, 2018, Design and development of an emissivity measurement set-up for use at 100 K, Indian J. Cryog., 43, 45, 10.5958/2349-2120.2018.00007.9 · DOI
- Persky, 1999, Review of black surfaces for space-borne infrared systems, Rev. Sci. Instrum., 70, 2193, 10.1063/1.1149739 · DOI
- Gangradey, 2020, Activated charcoal cooled to liquid helium temperature exhibiting pumping for hydrogen and helium gases, Vacuum, 172, 10.1016/j.vacuum.2019.109026 · DOI
- Musilova, 2007, Effect of different treatments of copper surface on its total hemispherical absorptivity bellow 77 K, Cryogenics, 47, 257, 10.1016/j.cryogenics.2007.02.001 · DOI · Paper page
- Fabron, 2000, Measurements of low hemispheric emissivity at low temperatures—designing a cryogenic test bench, 10.4271/2000-01-2526 · DOI
- Ramasamy, 1992, Measurement of total hemispherical emittance on spacecraft thermal control coatings, 10.4271/921329 · DOI
- Kralik, 2009, Black surfaces for infrared, aerospace, and cryogenic applications, Proc. SPIE, 7298, 729813, 10.1117/12.819277 · DOI
Cited by
Sorted by citations
Thermal Radiation Testing Methods at Cryogenic Temperatures: A Review
Li, B., & Shen, F. (2026) · Cryo · doi:10.3390/cryo2010004 · Cited by 1
Metadata
- Authors
- Dewasi, A., Gangradey, R., Mukherjee, S. S., Gupta, V., Dutta, R., Desai, A. B., Mishra, J. S., Panchal, P., Nayak, P. A., & Agravat, H. S.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2023-09-01
- Volume
- 34
- Issue
- 12
- Pages
- 125908
- ISSN
- 0957-0233
- 1361-6501
- Cited by
- 6
- References
- 0
- Licence
- Funders
- Department of Atomic Energy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review