Receiver operating characteristic (ROC) curves: review of methods with applications in diagnostic medicine
Open accessThe DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Abstract
Receiver operating characteristic (ROC) analysis is a tool used to describe the discrimination accuracy of a diagnostic test or prediction model. While sensitivity and specificity are the basic metrics of accuracy, they have many limitations when characterizing test accuracy, particularly when comparing the accuracies of competing tests. In this article we review the basic study design features of ROC studies, illustrate sample size calculations, present statistical methods for measuring and comparing accuracy, and highlight commonly used ROC software. We include descriptions of multi-reader ROC study design and analysis, address frequently seen problems of verification and location bias, discuss clustered data, and provide strategies for testing endpoints in ROC studies. The methods are illustrated with a study of transmission ultrasound for diagnosing breast lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · cited 1×
“We can control the type I error by using the Holm’s correction (Holm 1979).”
MethodHanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Basic principles of ROC analysis
Metz, C. E. (1978) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(78)80014-2 · Cited by 6,026
STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · BMJ · doi:10.1136/bmj.h5527 · Cited by 3,660 · cited 1×
“Note that the STARD group (Bossuyt 2015) has published a list of features (study design and analysis items) that serves to standardize the reporting of diagnostic test accuracy studies but is also a helpful aid during the planning phase.”
BackgroundTime‐Dependent ROC Curves for Censored Survival Data and a Diagnostic Marker
Heagerty, P. J., Lumley, T., & Pepe, M. S. (2000) · Biometrics · doi:10.1111/j.0006-341x.2000.00337.x · Cited by 2,854
The Statistical Evaluation of Medical Tests for Classification and Prediction
Pepe, M. S. (2003) · doi:10.1093/oso/9780198509844.001.0001 · Cited by 2,198
The Statistical Evaluation of Medical Tests for Classification and Prediction
(2005) · Technometrics · doi:10.1198/tech.2005.s278 · Cited by 1,899
Statistical Methods in Diagnostic Medicine
Zhou, X., Obuchowski, N. A., & McClish, D. K. (2011) · Wiley Series in Probability and Statistics · doi:10.1002/9780470906514 · Cited by 1,784
Self-citationSignal detection theory and ROC analysis
Egan, J. P. (1975) · Academic Press eBooks · Cited by 1,659
ROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642
STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · Radiology · doi:10.1148/radiol.2015151516 · Cited by 1,337
A decision-making theory of visual detection.
Tanner, W. P., & Swets, J. A. (1954) · Psychological Review · doi:10.1037/h0058700 · Cited by 1,317
The Efficacy of Diagnostic Imaging
Fryback, D. G., & Thornbury, J. R. (1991) · Medical Decision Making · doi:10.1177/0272989x9101100203 · Cited by 1,291
(1982) · Cited by 1,288
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Dorfman, D. D., & Alf, E. (1969) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(69)90019-4 · Cited by 874
The theory of signal detectability
Peterson, W., Birdsall, T., & Fox, W. (1954) · Transactions of the IRE Professional Group on Information Theory · doi:10.1109/tit.1954.1057460 · Cited by 867
Metz, C. E., Herman, B. A., & Shen, J.-H. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19980515)17:9<1033::aid-sim784>3.0.co;2-z · Cited by 793
Signal Detection Theory and ROC Analysis in Psychology and Diagnostics: Collected Papers
Swets, J. A. (1996) · Medical Entomology and Zoology · Cited by 767
Guidelines for Meta-analyses Evaluating Diagnostic Tests
Irwig, L., Tosteson, A. N. A., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T. C., & Mosteller, F. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-8-199404150-00008 · Cited by 753
Assessment of diagnostic tests when disease verification is subject to selection bias
Begg, C. B., & Greenes, R. A. (1983) · Biometrics · doi:10.2307/2530820 · Cited by 708
Analyzing a Portion of the ROC Curve
McClish, D. K. (1989) · Medical Decision Making · doi:10.1177/0272989x8900900307 · Cited by 707
Nonparametric Analysis of Clustered ROC Curve Data
Obuchowski, N. A. (1997) · Biometrics · doi:10.2307/2533958 · Cited by 429
Self-citationMetz, C. E., Wang, P.-L., & Kronman, H. B. (1984) · Information Processing in Medical Imaging · doi:10.1007/978-94-009-6045-9_25 · Cited by 356
Partial AUC Estimation and Regression
Dodd, L. E., & Pepe, M. S. (2003) · Biometrics · doi:10.1111/1541-0420.00071 · Cited by 346
Beam, C. A. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.1996.00440020119016 · Cited by 337
The Robustness of the "Binormal" Assumptions Used in Fitting ROC Curves
Hanley, J. A. (1988) · Medical Decision Making · doi:10.1177/0272989x8800800308 · Cited by 309
Lusted, L. B. (1971) · Science · doi:10.1126/science.171.3977.1217 · Cited by 304
Combining diagnostic test results to increase accuracy
Pepe, M. S. (2000) · Biostatistics · doi:10.1093/biostatistics/1.2.123 · Cited by 303
Mossman, D. (1999) · Medical Decision Making · doi:10.1177/0272989x9901900110 · Cited by 302
GREENES, R. A., & BEGG, C. B. (1985) · Investigative Radiology · doi:10.1097/00004424-198510000-00018 · Cited by 292
A General Regression Methodology for ROC Curve Estimation
Tosteson, A. N. A., & Begg, C. B. (1988) · Medical Decision Making · doi:10.1177/0272989x8800800309 · Cited by 272
Obuchowski, N. A., & Rockette, H. E. (1995) · Communications in Statistics - Simulation and Computation · doi:10.1080/03610919508813243 · Cited by 234
Self-citationJanes, H., & Pepe, M. S. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwn099 · Cited by 212
Distribution-free ROC analysis using binary regression techniques
Alonzo, T. A. (2002) · Biostatistics · doi:10.1093/biostatistics/3.3.421 · Cited by 203
Statistical significance tests for binormal ROC curves
Metz, C. E., & Kronman, H. B. (1980) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(80)90020-6 · Cited by 175
Hillis, S. L., Obuchowski, N. A., Schartz, K. M., & Berbaum, K. S. (2005) · Statistics in Medicine · doi:10.1002/sim.2024 · Cited by 155
Self-citationROC analysis in medical imaging: a tutorial review of the literature
Metz, C. E. (2007) · Radiological Physics and Technology · doi:10.1007/s12194-007-0002-1 · Cited by 154
A comparison of denominator degrees of freedom methods for multiple observer ROC analysis
Hillis, S. L. (2007) · Statistics in Medicine · doi:10.1002/sim.2532 · Cited by 151
One-Shot Estimate of MRMC Variance: AUC
Gallas, B. D. (2006) · Academic Radiology · doi:10.1016/j.acra.2005.11.030 · Cited by 146
Janes, H., & Pepe, M. S. (2009) · Biometrika · doi:10.1093/biomet/asp002 · Cited by 142
Zhang, D. D., Zhou, X., Freeman, D. H., & Freeman, J. L. (2002) · Statistics in Medicine · doi:10.1002/sim.1011 · Cited by 137
Statistical Evaluation of Diagnostic Performance: Topics in Roc Analysis
Rockette, H. E. (2011) · Medical Entomology and Zoology · Cited by 135
Estimating and Comparing Diagnostic Tests’ Accuracy When the Gold Standard Is Not Binary1
Obuchowski, N. A. (2005) · Academic Radiology · doi:10.1016/j.acra.2005.05.013 · Cited by 130
Self-citationNakas, C. T., Alonzo, T. A., & Yiannoutsos, C. T. (2010) · Statistics in Medicine · doi:10.1002/sim.4044 · Cited by 129
An ROC-type measure of diagnostic accuracy when the gold standard is continuous-scale
Obuchowski, N. A. (2005) · Statistics in Medicine · doi:10.1002/sim.2228 · Cited by 128
Self-citationBeiden, S. V., Wagner, R. F., & Campbell, G. (2000) · Academic Radiology · doi:10.1016/s1076-6332(00)80008-2 · Cited by 126
Multireader, multicase receiver operating characteristic analysis:
Obuchowski, N. A., Beiden, S. V., Berbaum, K. S., Hillis, S. L., Ishwaran, H., Song, H. H., & Wagner, R. F. (2004) · Academic Radiology · doi:10.1016/j.acra.2004.04.014 · Cited by 108
Self-citationMu, W., Chen, Z., Liang, Y., Shen, W., Yang, F., Dai, R., Wu, N., & Tian, J. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/13/5123 · Cited by 100
Modern statistical approaches to reception in communication theory
Meter, D. V., & Middleton, D. (1954) · Transactions of the IRE Professional Group on Information Theory · doi:10.1109/tit.1954.1057471 · Cited by 95
Semiparametric Regression for the Area Under the Receiver Operating Characteristic Curve
Dodd, L. E., & PEPE, M. S. (2003) · Journal of the American Statistical Association · doi:10.1198/016214503000198 · Cited by 94
Ishwaran, H., & Gatsonis, C. A. (2000) · Canadian Journal of Statistics · doi:10.2307/3315913 · Cited by 89
Multireader receiver operating characteristic studies: A comparison of study designs
Obuchowski, N. A. (1995) · Academic Radiology · doi:10.1016/s1076-6332(05)80441-6 · Cited by 88
Self-citationAssessing Accuracy of a Continuous Screening Test in the Presence of Verification Bias
Alonzo, T. A., & PEPE, M. S. (2004) · Journal of the Royal Statistical Society Series C (Applied Statistics) · doi:10.1111/j.1467-9876.2005.00477.x · Cited by 88
A Framework for Random-Effects ROC Analysis: Biases with the Bootstrap and Other Variance Estimators
Gallas, B. D., Bandos, A. I., Samuelson, F. W., & Wagner, R. F. (2009) · Communication in Statistics- Theory and Methods · doi:10.1080/03610920802610084 · Cited by 73
Continuous versus Categorical Data for ROC Analysis
Wagner, R. F., Beiden, S. V., & Metz, C. E. (2001) · Academic Radiology · doi:10.1016/s1076-6332(03)80502-0 · Cited by 71
Ideal Observers and Optimal ROC Hypersurfaces in $N$ -Class Classification
Edwards, D. C., Metz, C. E., & Kupinski, M. A. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828358 · Cited by 64
Power Estimation for Multireader ROC Methods
Hillis, S. L., Obuchowski, N. A., & Berbaum, K. S. (2011) · Academic Radiology · doi:10.1016/j.acra.2010.09.007 · Cited by 63
Self-citationShiraishi, J., Pesce, L. L., Metz, C. E., & Doi, K. (2009) · Radiology · doi:10.1148/radiol.2533081632 · Cited by 60
Shiu, S., & Gatsonis, C. (2008) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2008.0043 · Cited by 52
He, H., Lyness, J. M., & McDermott, M. (2008) · Statistics in Medicine · doi:10.1002/sim.3388 · Cited by 46
Rotnitzky, A. G., Faraggi, D., & Schisterman, E. F. (2006) · Journal of the American Statistical Association · doi:10.1198/016214505000001339 · Cited by 44
Hypothesis Testing in Noninferiority and Equivalence MRMC ROC Studies
Chen, W., Petrick, N., & Sahiner, B. (2012) · Academic Radiology · doi:10.1016/j.acra.2012.04.011 · Cited by 43
Toledano, A. Y., & Gatsonis, C. (1999) · Biometrics · doi:10.1111/j.0006-341x.1999.00488.x · Cited by 43
Dendumrongsup, T., Plumb, A., Halligan, S., Fanshawe, T. R., Altman, D. G., & Mallett, S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0116018 · Cited by 42
Analysis of rating data from multiple-alternative tasks
Kijewski, M. F., Swensson, R. G., & Judy, P. F. (1989) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(89)90020-5 · Cited by 38
ROC Curve Estimation When Covariates Affect the Verification Process
Rodenberg, C., & Zhou, X. (2000) · Biometrics · doi:10.1111/j.0006-341x.2000.01256.x · Cited by 38
Allen, J., Murray, A., Maria, C. D., & Newton, J. L. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/231 · Cited by 30
Liu, D., & Zhou, X. (2010) · Biometrics · doi:10.1111/j.1541-0420.2010.01397.x · Cited by 30
Reducing the Number of Reader Interpretations in MRMC Studies
Obuchowski, N. A. (2009) · Academic Radiology · doi:10.1016/j.acra.2008.05.014 · Cited by 27
Self-citationIuanow, E., Smith, K., Obuchowski, N. A., Bullen, J. A., & Klock, J. (2017) · Academic Radiology · doi:10.1016/j.acra.2017.03.024 · Cited by 25
Self-citationReceiver Operating Characteristic Analysis for the Evaluation of Diagnosis and Prediction
Gatsonis, C. A. (2009) · Radiology · doi:10.1148/radiol.2533091633 · Cited by 16
Assessing Accuracy of Mammography in the Presence of Verification Bias and Intrareader Correlation
Zheng, Y., Barlow, W. E., & Cutter, G. (2005) · Biometrics · doi:10.1111/j.0006-341x.2005.031139.x · Cited by 16
McGowan, L. D., Bullen, J. A., & Obuchowski, N. A. (2016) · Statistics in Biopharmaceutical Research · doi:10.1080/19466315.2016.1173583 · Cited by 8
Self-citation
Cited by
Carrington, A. M., Manuel, D. G., Fieguth, P. W., Ramsay, T., Osmani, V., Wernly, B., Bennett, C., Hawken, S., Magwood, O., Sheikh, Y., et al. (2023) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2022.3145392 · Cited by 339
Biomarker-Guided Imaging and AI-Augmented Diagnosis of Degenerative Joint Disease
Kumar, R., Sporn, K., Borole, A., Khanna, A., Gowda, C., Paladugu, P., Ngo, A., Jagadeesan, R., Zaman, N., & Tavakkoli, A. (2025) · Diagnostics · doi:10.3390/diagnostics15111418 · Cited by 13
Giordani, A. S., Pontara, E., Vicenzetto, C., Baritussio, A., Peloso Cattini, M. G., Bison, E., Re, F., Marcolongo, R., Joseph, S., Chatterjee, D., et al. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13226736 · Cited by 8
Zhang, T., Ji, C., Zhu, J., Wang, X., Shen, C., Liang, F., Hou, Y., Sun, Y., Wang, C., Wang, P., et al. (2025) · BMC Psychiatry · doi:10.1186/s12888-025-06516-w · Cited by 5
Metadata
- Authors
- Obuchowski, N. A., & Bullen, J. A.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2018-03-29
- Volume
- 63
- Issue
- 7
- Pages
- 07TR01
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2791209104
- Cited by
- 542
- References
- 78
- FWCI
- 26.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.