CoChat

First benchmarking of the BIANCA model for cell survival prediction in a clinical hadron therapy scenario

Open access
Carante, M P, Aricò, G, Ferrari, A, Kozlowska, W, Mairani, A, Ballarini, F · 2019 · Physics in Medicine & Biology

The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.

Abstract

In the framework of RBE modelling for hadron therapy, the BIANCA biophysical model was extended to O-ions and was used to construct a radiobiological database describing the survival of V79 cells as a function of ion type (1 ⩽ Z ⩽ 8) and energy. This database allowed performing RBE predictions in very good agreement with experimental data. A method was then developed to construct analogous databases for different cell lines, starting from the V79 database as a reference. Following interface to the FLUKA Monte Carlo radiation transport code, BIANCA was then applied for the first time to predict cell survival in a typical patient treatment scenario, consisting of two opposing fields of range-equivalent protons or C-ions. The model predictions were found to be in good agreement with CHO cell survival data obtained at the Heidelberg ion-beam therapy (HIT) centre, as well as predictions performed by the local effect model (version LEM IV). This work shows that BIANCA can be used to predict cell survival and RBE not only for V79 and AG01522 cells, as shown previously, but also, in principle, for any cell line of interest. Furthermore, following interface to a transport code like FLUKA, BIANCA can provide predictions of 3D biological dose distributions for hadron therapy treatments, thus laying the foundations for future applications in clinics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6560/ab490f

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Survival of V79 cells exposed to O-ion beams of 18 keV μ m -1 , 46 keV μ m -1 (panel (a)), 238 keV μ m -1 , 276 keV μ m -1 and 754 keV μ m -1 (panel (b)). The lines are simulation outcomes, the points are experimental data taken from Stoll et al (1995).
Figure 1 Survival of V79 cells exposed to O-ion beams of 18 keV μ m -1 , 46 keV μ m -1 (panel (a)), 238 keV μ m -1 , 276 keV μ m -1 and 754 keV μ m -1 (panel (b)). The lines are simulation outcomes, the points are experimental data taken from Stoll et al (1995).CC-BY · From the PDF
Figure 2 (a) The lines represent the RBE at 10% survival calculated for V79 cells exposed to protons (solid line) and He-ions (dashed line); the points are V79 experimental data for protons (full circles, taken from Folkard et al (1996) and Belli et al (1998)) and He-ions (empty circles, from Furusawa et al (2000)), as well as a Li-ion point at 60 keV μ m -1 (taken from Pathak et al (2007)). (b) The line represents the RBE at 10% survival calculated for V79 cells exposed to C-ions; the points are V79 experimental data for C-ions (full circles, taken from Furusawa et al (2000)), as well as O-ions (empty circles, from Stoll et al (1995)), B-ions (asterisks, from Cox et al (1977)) and N-ions (empty square, Cox et al (1977)). The error bars, where available, represent one s.d.
Figure 2 (a) The lines represent the RBE at 10% survival calculated for V79 cells exposed to protons (solid line) and He-ions (dashed line); the points are V79 experimental data for protons (full circles, taken from Folkard et al (1996) and Belli et al (1998)) and He-ions (empty circles, from Furusawa et al (2000)), as well as a Li-ion point at 60 keV μ m -1 (taken from Pathak et al (2007)). (b) The line represents the RBE at 10% survival calculated for V79 cells exposed to C-ions; the points are V79 experimental data for C-ions (full circles, taken from Furusawa et al (2000)), as well as O-ions (empty circles, from Stoll et al (1995)), B-ions (asterisks, from Cox et al (1977)) and N-ions (empty square, Cox et al (1977)). The error bars, where available, represent one s.d.CC-BY · From the PDF
Figure 3 (a) The lines represent the RBE at 50% survival calculated for V79 cells exposed to protons (solid line) and He-ions (dashed line); the points are V79 experimental data for protons (full circles, taken from Folkard et al (1996) and Belli et al (1998)) and He-ions (empty circles, from Furusawa et al (2000)), as well as a Li-ion point at 60 keV μ m -1 (taken from Pathak et al (2007)). (b) The line represents the RBE at 50% survival calculated for V79 cells exposed to C-ions. The points are V79 experimental data for C-ions (full circles, taken from Furusawa et al (2000)), as well as O-ions (empty circles, from Stoll et al (1995)), B-ions (asterisks, from Cox et al (1977)) and N-ions (empy square, Cox et al (1977)). The error bars, where available, represent one s.d.
Figure 3 (a) The lines represent the RBE at 50% survival calculated for V79 cells exposed to protons (solid line) and He-ions (dashed line); the points are V79 experimental data for protons (full circles, taken from Folkard et al (1996) and Belli et al (1998)) and He-ions (empty circles, from Furusawa et al (2000)), as well as a Li-ion point at 60 keV μ m -1 (taken from Pathak et al (2007)). (b) The line represents the RBE at 50% survival calculated for V79 cells exposed to C-ions. The points are V79 experimental data for C-ions (full circles, taken from Furusawa et al (2000)), as well as O-ions (empty circles, from Stoll et al (1995)), B-ions (asterisks, from Cox et al (1977)) and N-ions (empy square, Cox et al (1977)). The error bars, where available, represent one s.d.CC-BY · From the PDF
Figure 4 Surviving fraction for CHO cells in a typical two-port irradiation with carbon ions (panel (a)) and protons (panel (b)). The solid lines represent the predictions performed by BIANCA interfaced to FLUKA, the points are experimental data taken from Elsässer et al (2010), and the dashed lines, also taken from Elsässer et al (2010), represent the prediction performed by LEM integrated into TRiP98.
Figure 4 Surviving fraction for CHO cells in a typical two-port irradiation with carbon ions (panel (a)) and protons (panel (b)). The solid lines represent the predictions performed by BIANCA interfaced to FLUKA, the points are experimental data taken from Elsässer et al (2010), and the dashed lines, also taken from Elsässer et al (2010), represent the prediction performed by LEM integrated into TRiP98.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 23

Metadata

Authors
Carante, M. P., Aricò, G., Ferrari, A., Kozlowska, W., Mairani, A., & Ballarini, F.
Affiliations
  • Istituto Nazionale di Fisica Nucleare (IT)
  • European Organization for Nuclear Research (CH)
  • National Center for Oncological Hadrontherapy (IT)
Corresponding author
Ballarini, F
Venue
Physics in Medicine & Biology
Published
2019-10-31
Volume
64
Issue
21
Pages
215008
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2978013742
Cited by
23
References
47
Citations by year
2026: 3 · 2025: 1 · 2024: 6 · 2023: 4 · 2022: 3 · 2021: 3 · 2020: 3
FWCI
1.65
Type
journal article
Language
en
Open access
Licence
Locations
  • Physics in Medicine and Biology (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • International Linear Collider (submittedVersion, cc-by)
Funders
  • European Commission (675265)
  • Nuclear Physics
Topics
  • Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
Keywords
relative biological effectiveness, particle therapy, carbon ion radiotherapy, oxygen ions, V79 cells, CHO cells, FLUKA, local effect model, ion beam therapy
MeSH terms
Animals, Cell Survival, Cricetulus, Elementary Particles, Cricetinae, Humans, Monte Carlo Method, Radiotherapy Planning, Computer-Assisted, Relative Biological Effectiveness, CHO Cells, Benchmarking, Heavy Ion Radiotherapy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.