First benchmarking of the BIANCA model for cell survival prediction in a clinical hadron therapy scenario
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
In the framework of RBE modelling for hadron therapy, the BIANCA biophysical model was extended to O-ions and was used to construct a radiobiological database describing the survival of V79 cells as a function of ion type (1 ⩽ Z ⩽ 8) and energy. This database allowed performing RBE predictions in very good agreement with experimental data. A method was then developed to construct analogous databases for different cell lines, starting from the V79 database as a reference. Following interface to the FLUKA Monte Carlo radiation transport code, BIANCA was then applied for the first time to predict cell survival in a typical patient treatment scenario, consisting of two opposing fields of range-equivalent protons or C-ions. The model predictions were found to be in good agreement with CHO cell survival data obtained at the Heidelberg ion-beam therapy (HIT) centre, as well as predictions performed by the local effect model (version LEM IV). This work shows that BIANCA can be used to predict cell survival and RBE not only for V79 and AG01522 cells, as shown previously, but also, in principle, for any cell line of interest. Furthermore, following interface to a transport code like FLUKA, BIANCA can provide predictions of 3D biological dose distributions for hadron therapy treatments, thus laying the foundations for future applications in clinics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FLUKA: A Multi-Particle Transport Code
Ferrari, A., Sala, P. R., Fasso, A., & Ranft, J. (2005) · doi:10.2172/877507 · Cited by 2,536 · cited 1×
“Afterwards, BIANCA was interfaced to the FLUKA Monte Carlo radiation transport code (Ferrari et al 2005, Bohlen et al 2014, Battistoni et al 2016, Kozlowska et al 2019), which is currently used at HIT and at CNAO for treatment planning verification and re-calculation.”
MethodSelf-citationThe FLUKA Code: Developments and Challenges for High Energy and Medical Applications
Böhlen, T. T., Cerutti, F., Chin, M. P. W., Fassò, A., Ferrari, A., Ortega, P. G., Mairani, A., Sala, P. R., Smirnov, G., & Vlachoudis, V. (2014) · Nuclear Data Sheets · doi:10.1016/j.nds.2014.07.049 · Cited by 1,758
Self-citationRelative biological effectiveness (RBE) values for proton beam therapy
Paganetti, H., Niemierko, A., Ancukiewicz, M., Gerweck, L. E., Goitein, M., Loeffler, J. S., & Suit, H. D. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02754-2 · Cited by 1,364 · cited 1×
“Since these variations are much more pronounced for C-ions than for protons, a constant RBE value of 1.1 is currently adopted in proton therapy (e.g. Paganetti et al (2002)), whereas more detailed RBE models are required for carbon and possibly other heavy ions of interest like He- and O-ions…”
BackgroundInfluentialFurusawa, Y., Fukutsu, K., Aoki, M., Itsukaichi, H., Eguchi-Kasai, K., Ohara, H., Yatagai, F., Kanai, T., & Ando, K. (2000) · Radiation Research · doi:10.1667/0033-7587(2000)154[0485:ioaahc]2.0.co;2 · Cited by 474 · cited 7×
“…protons (solid line) and He-ions (dashed line); the points are V79 experimental data for protons (full circles, taken from Folkard et al (1996) and Belli et al (1998)) and He-ions (empty circles, from Furusawa et al (2000)), as well as a Li-ion point at 60 keV μm−1 (taken from Pathak et al (2007)).”
MethodResultInfluentialComputation of cell survival in heavy ion beams for therapy
Scholz, M., Kellerer, A. M., Kraft-Weyrather, W., & Kraft, G. (1997) · Radiation and Environmental Biophysics · doi:10.1007/s004110050055 · Cited by 464 · cited 1×
“Detailed descriptions of the different model versions can be found in the literature (e.g. Scholz et al (1997), Elsässer and Scholz (2007), Elsässer et al (2008) and Friedrich et al (2012)).”
MethodSorge, H., Stöcker, H., & Greiner, W. (1989) · Annals of Physics · doi:10.1016/0003-4916(89)90136-x · Cited by 458
Krämer, M., & Scholz, M. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/11/314 · Cited by 453
Irradiation of Mixed Beam and Design of Spread-Out Bragg Peak for Heavy-Ion Radiotherapy
Kanai, T., Furusawa, Y., Fukutsu, K., Itsukaichi, H., Eguchi-Kasai, K., & Ohara, H. (1997) · Radiation Research · doi:10.2307/3579446 · Cited by 422 · cited 1×
“On the other hand, a phenomenological model was first developed and used at NIRS in Japan (Kanai et al 1997).”
MethodElsässer, T., Weyrather, W. K., Friedrich, T., Durante, M., Iancu, G., Krämer, M., Kragl, G., Brons, S., Winter, M., Weber, K.-J., et al. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.05.014 · Cited by 351 · cited 8×
“…bars, where available, represent one s.d. nal beam energies available at HIT (e.g. Parodi et al (2012)) for carbon ions in the range 175–230 MeV/u, and for protons in the range 90–120 MeV/u (as in the experiment reported in Elsässer et al (2010)) were used in FLUKA to model the irradiation field.”
MethodResultInfluentialCornforth, M. N., & Bedford, J. S. (1987) · Radiation Research · doi:10.2307/3576926 · Cited by 332 · cited 1×
“…cell death and chromosome aberrations is derived from experimental observations indicating a one-to-one relationship between the logarithm of the surviving fraction and the mean number of dicentrics, rings and deletions visible in metaphase (e.g. Carrano (1973) and Cornforth and Bedford (1987)).”
BackgroundTreatment planning for a scanned carbon beam with a modified microdosimetric kinetic model
Inaniwa, T., Furukawa, T., Kase, Y., Matsufuji, N., Toshito, T., Matsumoto, Y., Furusawa, Y., & Noda, K. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/22/008 · Cited by 328
Schipler, A., & Iliakis, G. (2013) · Nucleic Acids Research · doi:10.1093/nar/gkt556 · Cited by 291 · cited 2×
“More specifically, a survey on the spectrum of possible DSB types (Schipler and Iliakis 2013) concluded that the various repair pathways can are likely to fail in case of DSB clusters, which undermine local chromatin stability leading to inaccurate rejoining, possibly via nonhomologous end-joining (NHEJ).”
BackgroundHawkins, R. B. (2003) · Radiation Research · doi:10.1667/rr3010 · Cited by 275
The FLUKA Code: An Accurate Simulation Tool for Particle Therapy
Battistoni, G., Bauer, J., Boehlen, T. T., Cerutti, F., Chin, M. P. W., Dos Santos Augusto, R., Ferrari, A., Ortega, P. G., Kozłowska, W., Magro, G., et al. (2016) · Frontiers in Oncology · doi:10.3389/fonc.2016.00116 · Cited by 272
Self-citationInaniwa, T., Kanematsu, N., Matsufuji, N., Kanai, T., Shirai, T., Noda, K., Tsuji, H., Kamada, T., & Tsujii, H. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/8/3271 · Cited by 263
A Statistical Theory of Cell Killing by Radiation of Varying Linear Energy Transfer
Hawkins, R. B. (1994) · Radiation Research · doi:10.2307/3579114 · Cited by 235
Chaudhary, P., Marshall, T. I., Perozziello, F. M., Manti, L., Currell, F. J., Hanton, F., McMahon, S. J., Kavanagh, J. N., Cirrone, G. A. P., Romano, F., et al. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.05.010 · Cited by 229
Elsässer, T., Krämer, M., & Scholz, M. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.02.037 · Cited by 225 · cited 1×
“Detailed descriptions of the different model versions can be found in the literature (e.g. Scholz et al (1997), Elsässer and Scholz (2007), Elsässer et al (2008) and Friedrich et al (2012)).”
MethodParodi, K., Mairani, A., Brons, S., Hasch, B. G., Sommerer, F., Naumann, J., Jäkel, O., Haberer, T., & Debus, J. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/12/3759 · Cited by 221
Self-citationRBE and related modeling in carbon-ion therapy
Karger, C. P., & Peschke, P. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa9102 · Cited by 211
Friedrich, T., Scholz, U., Elsässer, T., Durante, M., & Scholz, M. (2012) · International Journal of Radiation Biology · doi:10.3109/09553002.2011.611213 · Cited by 205 · cited 1×
“However, RBE is a complex quantity that depends on both physical and biological parameters. Since these variations are much more pronounced for C-ions than for protons, a constant RBE value of 1.1 is currently adopted in proton therapy (e.g. Paganetti et al (2002)), whereas more detailed RBE models are required for ca…”
BackgroundInfluentialCluster Effects within the Local Effect Model
Elsässer, T., & Scholz, M. (2007) · Radiation Research · doi:10.1667/rr0467.1 · Cited by 205 · cited 1×
“Detailed descriptions of the different model versions can be found in the literature (e.g. Scholz et al (1997), Elsässer and Scholz (2007), Elsässer et al (2008) and Friedrich et al (2012)).”
MethodBELLI F. CERA R. CHERUBINI M. DALLA, M. (1998) · International Journal of Radiation Biology · doi:10.1080/095530098141375 · Cited by 173 · cited 9×
“The RBE values calculated for protons were compared with experimental data taken from Belli et al (1998) (LET values: 7.”
MethodResultInfluentialThe synergistic effects of different radiations
Zaider, M., & Rossi, H. H. (1980) · Radiation Research · doi:10.2307/3575352 · Cited by 167 · cited 2×
“These values are then used to calculate the corresponding parameters αmix and βmix for a LET spectrum at a given depth within a SOBP, based on the Theory of Dual Radiation Action developed by Zaider and Rossi (1980).”
MethodInactivation of V79 cells by low-energy protons, deuterons and helium-3 ions
FOLKARD, M. (1996) · International Journal of Radiation Biology · doi:10.1080/095530096145472 · Cited by 161
Mutation and inactivation of mammalian cells by various ionising radiations
Cox, R., THACKER, J., GOODHEAD, D. T., & MUNSON, R. J. (1977) · Nature · doi:10.1038/267425a0 · Cited by 158 · cited 5×
“The points are V79 experimental data for C-ions (full circles, taken from Furusawa et al (2000)), as well as O-ions (empty circles, from Stoll et al (1995)), B-ions (asterisks, from Cox et al (1977)) and N-ions (empy square, Cox et al (1977)).”
BackgroundMethodInfluentialChromosome aberrations and radiation-induced cell death
Carrano, A. V. (1973) · Mutation research. Fundamental and molecular mechanisms of mutagenesis · doi:10.1016/0027-5107(73)90006-7 · Cited by 149 · cited 6×
“Extension to O-ions Up to now, the BIANCA model (version BIANCA II) has been applied to monochromatic beams of protons, C-ions and He ions, finding good agreement with experimental survival curves for V79 and AG01522 cells (e.g. Carante et al (2018)). In this work the approach was extended to O-ions, which are also of…”
BackgroundMethodInfluentialGiovannini, G., Böhlen, T. T., Cabal, G., Bauer, J., Tessonnier, T., Frey, K., Debus, J., Mairani, A., & Parodi, K. (2016) · Radiation Oncology · doi:10.1186/s13014-016-0642-6 · Cited by 125
Self-citationTommasino, F., Scifoni, E., & Durante, M. (2015) · International Journal of Particle Therapy · doi:10.14338/ijpt-15-00027.1 · Cited by 124
Mairani, A., Brons, S., Cerutti, F., Fassò, A., Ferrari, A., Krämer, M., Parodi, K., Scholz, M., & Sommerer, F. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/15/006 · Cited by 104
Self-citationA New Standard DNA Damage (SDD) Data Format
Schuemann, J., McNamara, A. L., Warmenhoven, J. W., Henthorn, N. T., Kirkby, K. J., Merchant, M. J., Ingram, S., Paganetti, H., Held, K. D., Ramos-Mendez, J., et al. (2018) · Radiation Research · doi:10.1667/rr15209.1 · Cited by 79
Self-citationX-rays vs. carbon-ion tumor therapy: cytogenetic damage in lymphocytes
Durante, M., Yamada, S., Ando, K., Furusawa, Y., Kawata, T., Majima, H., Nakano, T., & Tsujii, H. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00455-7 · Cited by 71
Kozłowska, W. S., Böhlen, T. T., Cuccagna, C., Ferrari, A., Fracchiolla, F., Magro, G., Mairani, A., Schwarz, M., Vlachoudis, V., & Georg, D. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab02cb · Cited by 58
Self-citationCarante, M. P., Aimè, C., Cajiao, J. J. T., & Ballarini, F. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aab45f · Cited by 52
Self-citationBallarini, F., Altieri, S., Bortolussi, S., Carante, M. P., Giroletti, E., & Protti, N. (2014) · Radiation and Environmental Biophysics · doi:10.1007/s00411-014-0537-6 · Cited by 49 · cited 1×
“…been fixed to the mean distance between two adjacent chromosome territories) has been shown to work well if the main purpose is to model cell death (Ballarini et al 2014, Carante et al 2015, 2018, 2019, Carante and Ballarini 2016), although some recent works have suggested that a (negative)…”
BackgroundSelf-citationModeling radiation-induced cell death: role of different levels of DNA damage clustering
Carante, M. P., Altieri, S., Bortolussi, S., Postuma, I., Protti, N., & Ballarini, F. (2015) · Radiation and Environmental Biophysics · doi:10.1007/s00411-015-0601-x · Cited by 48 · cited 1×
“…distance between two adjacent chromosome territories) has been shown to work well if the main purpose is to model cell death (Ballarini et al 2014, Carante et al 2015, 2018, 2019, Carante and Ballarini 2016), although some recent works have suggested that a (negative) exponential function works…”
BackgroundSelf-citationChromosome aberrations and cell death by ionizing radiation: evolution of a biophysical model
Ballarini, F., & Carante, M. P. (2016) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2016.06.009 · Cited by 45 · cited 1×
“A detailed discussion on these assumptions can be found elsewhere (Ballarini and Carante 2016, Carante and Ballarini 2016), and only a few key issues will be reported herein.”
BackgroundSelf-citationKilling and mutation of chinese hamster v79 cells exposed to accelerated oxygen and neon ions
Stoll, U., Schmidt, A., Schneider, E., & Kiefer, J. (1995) · Radiation Research · doi:10.2307/3579138 · Cited by 43 · cited 5×
“The points are V79 experimental data for C-ions (full circles, taken from Furusawa et al (2000)), as well as O-ions (empty circles, from Stoll et al (1995)), B-ions (asterisks, from Cox et al (1977)) and N-ions (empy square, Cox et al (1977)).”
BackgroundMethodInfluentialA model of chromosome aberration induction: applications to space research
Ballarini, F., & Ottolenghi, A. (2005) · Radiation Research · doi:10.1667/rr3365.1 · Cited by 33 · cited 1×
“Another on-going project is the construction of a radiobiological database specific for normal tissues based on dicentric aberrations in blood lymphocytes, which are widely considered as indicators of normal tissue damage (Durante et al 2000, Ballarini and Ottolenghi 2005).”
BackgroundSelf-citationCalculating Variations in Biological Effectiveness for a 62 MeV Proton Beam
Carante, M. P., & Ballarini, F. (2016) · Frontiers in Oncology · doi:10.3389/fonc.2016.00076 · Cited by 26
Self-citationProximity effects in chromosome aberration induction by low-LET ionizing radiation
Tello Cajiao, J. J., Carante, M. P., Bernal Rodriguez, M. A., & Ballarini, F. (2017) · DNA Repair · doi:10.1016/j.dnarep.2017.08.007 · Cited by 25
Self-citationTello Cajiao, J. J., Carante, M. P., Bernal Rodriguez, M. A., & Ballarini, F. (2018) · DNA Repair · doi:10.1016/j.dnarep.2018.02.006 · Cited by 19 · cited 1×
“…al 2015, 2018, 2019, Carante and Ballarini 2016), although some recent works have suggested that a (negative) exponential function works better if the purpose is to predict different aberration categories, in particular to distinguish between interand intra-arm exchanges (Tello et al 2017, 2018).”
BackgroundSelf-citationBallarini, F., Altieri, S., Bortolussi, S., Carante, M. P., Giroletti, E., & Protti, N. (2015) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncv135 · Cited by 16 · cited 1×
“Although the aforementioned critical lesions are likely to be DSB clusters (Ballarini et al 2015) and they have been called ‘cluster lesions’ in previous publications, their features are still unclear.”
BackgroundSelf-citationModelling cell death for cancer hadrontherapy
P. Carante, M., 1 Department of Physics, U. O. P., Ballarini, F., & 2 INFN-National Institute of Nuclear Physics, S. O. P. (2017) · AIMS Biophysics · doi:10.3934/biophy.2017.3.465 · Cited by 16
Self-citationTesta, A., Ballarini, F., Giesen, U., Gil, O. M., Carante, M. P., Cajiao, J. J. T., Langner, F., Rabus, H., Palma, V., Pinto, M., et al. (2018) · Radiation Research · doi:10.1667/rr15005.1 · Cited by 15 · cited 1×
“…pronounced for C-ions than for protons, a constant RBE value of 1.1 is currently adopted in proton therapy (e.g. Paganetti et al (2002)), whereas more detailed RBE models are required for carbon and possibly other heavy ions of interest like He- and O-ions (Tommasino et al 2015, Testa et al 2018).”
BackgroundInfluentialSelf-citationPathak, R., Dey, S. K., Sarma, A., & Khuda‐Bukhsh, A. R. (2007) · Mutation Research/Genetic Toxicology and Environmental Mutagenesis · doi:10.1016/j.mrgentox.2006.11.010 · Cited by 13 · cited 3×
“Concerning light ions, the proton results were compared with data taken from Folkard et al (1996) and Belli et al (1998), whereas the He-ion results were compared with 3He data taken from Furusawa et al (2000), as well as a 7Li point taken from Pathak et al (2007).”
MethodResultInfluentialPREDICTING BIOLOGICAL EFFECTS ALONG HADRONTHERAPY DOSE PROFILES BY THE BIANCA BIOPHYSICAL MODEL
Carante, M. P., Cajiao, J. J. T., & Ballarini, F. (2018) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncy263 · Cited by 5 · cited 7×
“In a previous work (Carante et al 2018), this approach has been successfully applied to AG01522 and U87 cells exposed to proton beams of different LET. In the present work we adopted the same approach for CHO cells irradiated at HIT by two opposing fields of protons or C-ions mimicking a typical patient treatment scen…”
MethodResultInfluentialSelf-citation
Cited by
Dose Calculation Algorithms for External Radiation Therapy: An Overview for Practitioners
Martino, F. D., Clemente, S., Graeff, C., Palma, G., & Cella, L. (2021) · Applied Sciences · doi:10.3390/app11156806 · Cited by 82
Challenges in Monte Carlo Simulations as Clinical and Research Tool in Particle Therapy: A Review
Muraro, S., Battistoni, G., & Kraan, A. C. (2020) · Frontiers in Physics · doi:10.3389/fphy.2020.567800 · Cited by 61
A Mission to Mars: Prediction of GCR Doses and Comparison with Astronaut Dose Limits
Ramos, R. L., Carante, M. P., FERRARI, A., SALA, P. R., Vercesi, V. I., & Ballarini, F. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24032328 · Cited by 37
Self-citationFukui, R., Saga, R., Matsuya, Y., Tomita, K., Kuwahara, Y., Ohuchi, K., Sato, T., Okumura, K., Date, H., Fukumoto, M., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-05172-4 · Cited by 34
In vivo validation of the BIANCA biophysical model: benchmarking against rat spinal cord RBE data
Carante, M. P., Aricò, G., Ferrari, A., Karger, C. P., Kozlowska, W., Mairani, A., Sala, P., & Ballarini, F. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21113973 · Cited by 21
Self-citation
Metadata
- Authors
- Carante, M. P., Aricò, G., Ferrari, A., Kozlowska, W., Mairani, A., & Ballarini, F.
- Affiliations
- Istituto Nazionale di Fisica Nucleare (IT)
- European Organization for Nuclear Research (CH)
- National Center for Oncological Hadrontherapy (IT)
- Corresponding author
- Ballarini, F
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2019-10-31
- Volume
- 64
- Issue
- 21
- Pages
- 215008
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2978013742
- Semantic Scholar
- f1728523465f20d4ef0c463137ab8fa60199c6cd
- Cited by
- 23
- References
- 47
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 6 · 2023: 4 · 2022: 3 · 2021: 3 · 2020: 3
- FWCI
- 1.65
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/3.0/ (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Physics in Medicine and Biology (publishedVersion, cc-by)
- PubMed (publishedVersion)
- International Linear Collider (submittedVersion, cc-by)
- Funders
- European Commission (675265)
- Nuclear Physics
- Topics
- Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
- Keywords
- relative biological effectiveness, particle therapy, carbon ion radiotherapy, oxygen ions, V79 cells, CHO cells, FLUKA, local effect model, ion beam therapy
- MeSH terms
- Animals, Cell Survival, Cricetulus, Elementary Particles, Cricetinae, Humans, Monte Carlo Method, Radiotherapy Planning, Computer-Assisted, Relative Biological Effectiveness, CHO Cells, Benchmarking, Heavy Ion Radiotherapy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.