The silicon photomultiplier: fundamentals and applications of a modern solid-state photon detector
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
The silicon photomultiplier (SiPM) is an established device of choice for a variety of applications, e.g. in time of flight positron emission tomography (TOF-PET), lifetime fluorescence spectroscopy, distance measurements in LIDAR applications, astrophysics, quantum-cryptography and related applications as well as in high energy physics (HEP). To fully utilize the exceptional performances of the SiPM, in particular its sensitivity down to single photon detection, the dynamic range and its intrinsically fast timing properties, a qualitative description and understanding of the main SiPM parameters and properties is necessary. These analyses consider the structure and the electrical model of a single photon avalanche diode (SPAD) and the integration in an array of SPADs, i.e. the SiPM. The discussion will include the front-end readout and the comparison between analog-SiPMs, where the array of SPADs is connected in parallel, and the digital SiPM, where each SPAD is read out and digitized by its own electronic channel. For several applications a further complete phenomenological view on SiPMs is necessary, defining several SiPM intrinsic parameters, i.e. gain fluctuation, afterpulsing, excess noise, dark count rate, prompt and delayed optical crosstalk, single photon time resolution (SPTR), photon detection effieciency (PDE) etc. These qualities of SiPMs influence directly and indirectly the time and energy resolution, for example in PET and HEP. This complete overview of all parameters allows one to draw solid conclusions on how best performances can be achieved for the various needs of the different applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical properties of intrinsic silicon at 300 K
Green, M. A., & Keevers, M. J. (1995) · Progress in Photovoltaics Research and Applications · doi:10.1002/pip.4670030303 · Cited by 1,364 · cited 1×
“(b) Light absorption length in Silicon (data from Green and Keevers 1995). n-doped region, connected to the positive pole of the bias voltage.”
BackgroundAvalanche photodiodes and quenching circuits for single-photon detection
Cova, S., Ghioni, M., Lacaita, A., Samori, C., & Zappa, F. (1996) · Applied Optics · doi:10.1364/ao.35.001956 · Cited by 1,114
Silicon photomultiplier and its possible applications
Buzhan, P., Dolgoshein, B., Filatov, L., Ilyin, A., Kantzerov, V., Kaplin, V., Karakash, A., Kayumov, F., Klemin, S., Popova, E., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)00749-6 · Cited by 636
Electric field effect on the thermal emission of traps in semiconductor junctions
Vincent, G., Chantre, A., & Bois, D. (1979) · Journal of Applied Physics · doi:10.1063/1.326601 · Cited by 535 · cited 1×
“In silicon the primary dark count rate is due to the thermal generation of carriers by states in the bandgap and it can be modeled using Shockley–Read–Hall (SRH) statistics (Vincent et al 1979).”
MethodGeiger-mode avalanche photodiodes, history, properties and problems
Renker, D. (2006) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2006.05.060 · Cited by 496
Advances in solid state photon detectors
Renker, D., & Lorenz, E. (2009) · Journal of Instrumentation · doi:10.1088/1748-0221/4/04/p04004 · Cited by 385 · cited 4×
“Picture modified from Renker and Lorenz (2009). photodiode (APD).”
BackgroundMethodInfluentialUnderstanding and simulating SiPMs
Acerbi, F., & Gundacker, S. (2018) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2018.11.118 · Cited by 385 · cited 2×
“Of course in the design of a SPAD additional factors like the exact doping profile, drift regions, field distribution and junction depth will influence the final detection efficiency (Acerbi and Gundacker 2019).”
BackgroundMethodSelf-citationTime of flight in PET revisited
Moses, W. W. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.817319 · Cited by 336
The digital silicon photomultiplier — Principle of operation and intrinsic detector performance
Frach, T., Prescher, G., Degenhardt, C., de Gruyter, R., Schmitz, A., & Ballizany, R. (2009) · 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) · doi:10.1109/nssmic.2009.5402143 · Cited by 317
On the bremsstrahlung origin of hot-carrier-induced photons in silicon devices
Lacaita, A. L., Zappa, F., Bigliardi, S., & Manfredi, M. (1993) · IEEE Transactions on Electron Devices · doi:10.1109/16.199363 · Cited by 288 · cited 2×
“The amount has been estimated to 3 · 10−5 photons per avalanche carrier (Lacaita et al 1993, Otte 2009).”
BackgroundPhoton counting techniques with silicon avalanche photodiodes
Dautet, H., Deschamps, P., Dion, B., MacGregor, A. D., MacSween, D., McIntyre, R. J., Trottier, C., & Webb, P. P. (1993) · Applied Optics · doi:10.1364/ao.32.003894 · Cited by 284
Gundacker, S., Martinez Turtos, R., Kratochwil, N., Pots, R. H., Paganoni, M., Lecoq, P., & Auffray, E. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab63b4 · Cited by 265 · cited 12×
“This is illustrated in figure 19 by comprehensive Monte-Carlo simulations (Gundacker et al 2016b, Gundacker et al 2020).”
BackgroundMethodInfluentialSelf-citationGrant, A. M., Deller, T. W., Khalighi, M. M., Maramraju, S. H., Delso, G., & Levin, C. S. (2016) · Medical Physics · doi:10.1118/1.4945416 · Cited by 247 · cited 2×
“Nevertheless, SiPMs have paved their way into TOF-PET due to the promise of excellent performances proven to deliver 100 ps CTR (in laboratory) and with the prospect of breaking this value even further towards 10 ps. Prominent examples of commercial systems are the Vereos Digital TOF-PET/CT developed by Philips using…”
MethodStudies of a Next-Generation Silicon-Photomultiplier–Based Time-of-Flight PET/CT System
Hsu, D. F. C., Ilan, E., Peterson, W. T., Uribe, J., Lubberink, M., & Levin, C. S. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.189514 · Cited by 241 · cited 1×
“…(Frach et al 2009) achieving a CTR of 300 ps FWHM, the Biograph Vision TOF-PET/CT from Siemens using analog SiPMs with refined readout architecture achieving a CTR of 210 ps FWHM (Conti and Bendriem 2019) and the launched whole body PET/CT from GE Healthcare named Discovery MI (Hsu et al 2017).”
MethodApplication of Silicon Photomultipliers to Positron Emission Tomography
Roncali, E., & Cherry, S. R. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0266-9 · Cited by 239 · cited 1×
“They are used in nuclear medical imaging (Roncali and Cherry 2011, Lecomte 2009, Vinke et al 2009, Gundacker et al 2016a, Cates et al 2015), for gamma spectroscopy and for time tagging of high energetic particles (Herbert et al 2006, Benaglia et al 2016, Garutti 2011, Pauwels et al 2013).”
MethodTriggering phenomena in avalanche diodes
Oldham, W. G., Samuelson, R. R., & Antognetti, P. (1972) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1972.17544 · Cited by 236
Novel type of avalanche photodetector with Geiger mode operation
Golovin, V., & Saveliev, V. (2004) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2003.11.085 · Cited by 233 · cited 1×
“…pixel photon counter, MPPC) is a solid state photodetector made of an array of hundreds or thousands of integrated single-photon avalanche diodes (SPADs), called microcells or pixels (Renker and Lorenz 2006, Renker and Lorenz 2009, Buzhan et al 2003, Golovin and Saveliev 2004, Herbert et al 2006).”
BackgroundNUV-Sensitive Silicon Photomultiplier Technologies Developed at Fondazione Bruno Kessler
Gola, A. G., Acerbi, F., Capasso, M., Marcante, M., Mazzi, A., Paternoster, G., Piemonte, C., Regazzoni, V., & Zorzi, N. (2019) · Sensors · doi:10.3390/s19020308 · Cited by 216 · cited 3×
“Newest developments of SiPMs lead to extented PDE in the VUV (Gola et al 2019), which was shown to open new doors in the study of cross-luminescence crystals (Laval et al 1983) for fastest timing applications (Gundacker et al 2020).”
BackgroundAn outlook on future design of hybrid PET/MRI systems: Design of hybrid PET/MRI scanners
Zaidi, H., & Del Guerra, A. (2011) · Medical Physics · doi:10.1118/1.3633909 · Cited by 193 · cited 1×
“However, due to the magnetic fields present in MR-systems and the demand of having a simultaneous hybrid system, PMTs were not an option anymore (Zaidi and Del Guerra 2011).”
BackgroundModel for the Electrical Behavior of a Microplasma
Haitz, R. H. (1964) · Journal of Applied Physics · doi:10.1063/1.1713636 · Cited by 193 · cited 1×
“The avalanche breakdown process has been studied in the ’60s and ’70s using avalanche photodiodes operated close to breakdown voltage or above (Haitz et al 1963, Haitz 1964, McIntyre 1961, Oldham et al 1972).”
MethodThe new opportunities for high time resolution clinical TOF PET
Conti, M., & Bendriem, B. (2019) · Clinical and Translational Imaging · doi:10.1007/s40336-019-00316-5 · Cited by 180 · cited 15×
“For example Cates and Levin (2016) showed a time resolution of 80 and 122 ps FWHMwith 3 and 20 mm long LGSO:Ce crystals coupled to NUV-HD SiPMs, respectively.”
MethodInfluentialTheory of Microplasma Instability in Silicon
McIntyre, R. J. (1961) · Journal of Applied Physics · doi:10.1063/1.1736199 · Cited by 180 · cited 1×
“The avalanche breakdown process has been studied in the ’60s and ’70s using avalanche photodiodes operated close to breakdown voltage or above (Haitz et al 1963, Haitz 1964, McIntyre 1961, Oldham et al 1972).”
MethodGundacker, S., Auffray, E., Pauwels, K., & Lecoq, P. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/7/2802 · Cited by 173 · cited 4×
“They are used in nuclear medical imaging (Roncali and Cherry 2011, Lecomte 2009, Vinke et al 2009, Gundacker et al 2016a, Cates et al 2015), for gamma spectroscopy and for time tagging of high energetic particles (Herbert et al 2006, Benaglia et al 2016, Garutti 2011, Pauwels et al 2013).”
BackgroundMethodResultInfluentialSelf-citationAdvances in time-of-flight PET
Surti, S., & Karp, J. S. (2016) · Physica Medica · doi:10.1016/j.ejmp.2015.12.007 · Cited by 173 · cited 2×
“Especially in PET, crystals like LYSO:Ce, LSO:Ce or BGO are comonly used (Surti and Karp 2016, Conti and Bendriem 2019, Bisogni et al 2019).”
MethodBGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET
Brünner, S., & Schaart, D. R. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa6a49 · Cited by 173 · cited 15×
“Furthermore new challenges in TOF-PET, high energy physics (HEP), time resolved x-ray detection and spectroscopy push developments of the SiPM to achieve single photon time resolutions (SPTRs) as much as physically possible to the few picosecond domain.”
BackgroundMethodInfluentialNovel detector technology for clinical PET
Lecomte, R. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-1054-0 · Cited by 165
Gundacker, S., Acerbi, F., Auffray, E., Ferri, A., Gola, A. G., Nemallapudi, M. V., Paternoster, G., Piemonte, C., & Lecoq, P. R. (2016) · Journal of Instrumentation · doi:10.1088/1748-0221/11/08/p08008 · Cited by 155 · cited 4×
“They are used in nuclear medical imaging (Roncali and Cherry 2011, Lecomte 2009, Vinke et al 2009, Gundacker et al 2016a, Cates et al 2015), for gamma spectroscopy and for time tagging of high energetic particles (Herbert et al 2006, Benaglia et al 2016, Garutti 2011, Pauwels et al 2013).”
BackgroundMethodResultInfluentialSelf-citationSub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with Ca
Nemallapudi, M. V., Gundacker, S., Lecoq, P. R., Auffray, E., Ferri, A., Gola, A. G., & Piemonte, C. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/12/4635 · Cited by 138 · cited 2×
“Further studies can be found in Vinke et al (2009), Powolny et al (2011), Seifert et al (2012), Gundacker et al (2013), Nemallapudi et al (2015), Gundacker et al (2016a), Cates and Levin (2016).”
BackgroundResultSelf-citation20-ps timing resolution with single-photon avalanche diodes
Cova, S., Lacaita, A. L., Ghioni, M., Ripamonti, G., & Louis, T. A. (1989) · Review of Scientific Instruments · doi:10.1063/1.1140324 · Cited by 136 · cited 1×
“The first avalanche photodiodes working above breakdown, in Geiger mode, have been proposed and studied in the ’80s and ’90s (McIntyre 1985, Cova et al 1989, Dautet et al 1993, Bondarenko et al 1998, Cova et al 1996).”
MethodComparison between new-generation SiPM-based and conventional PMT-based TOF-PET/CT
Wagatsuma, K., Miwa, K., Sakata, M., Oda, K., Ono, H., Kameyama, M., Toyohara, J., & Ishii, K. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.09.124 · Cited by 126 · cited 1×
“The fact that all major players are using SiPMs in their high end TOF-PET/CT products can be seen as a confirmation of the overall superiority of SiPMs over PMTs, both in cost effectiveness and performance (Wagatsuma et al 2017).”
BackgroundCates, J. W., Gundacker, S., Auffray, E., Lecoq, P. R., & Levin, C. S. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aadbcd · Cited by 123 · cited 5×
“An interesting concept is to use a balun tranformer to adapt the balanced SiPM signal to the unbalanced input of the amplifier (Cates et al 2018) which gives the additional advantage of suppressing common ground noise effectively, similar to a differential readout of the SiPM, e.g. as in the PETA…”
BackgroundMethodInfluentialSelf-citationPerformance of NUV-HD Silicon Photomultiplier Technology
Piemonte, C., Acerbi, F., Ferri, A., Gola, A. G., Paternoster, G., Regazzoni, V., Zappalà, G., & Zorzi, N. (2016) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2016.2516641 · Cited by 122
Weissler, B., Gebhardt, P., Duppenbecker, P. M., Goldschmidt, B., Salomon, A., Schug, D., Wehner, J., Lerche, C. W., Wirtz, D., Renz, W., et al. (2012) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2012.6551484 · Cited by 120
A Digital Preclinical PET/MRI Insert and Initial Results
Weissler, B., Gebhardt, P., Dueppenbecker, P. M., Wehner, J., Schug, D., Lerche, C. W., Goldschmidt, B., Salomon, A., Verel, I., Heijman, E., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2427993 · Cited by 106
Advances in coincidence time resolution for PET
Cates, J. W., & Levin, C. S. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/6/2255 · Cited by 104 · cited 2×
“Further studies can be found in Vinke et al (2009), Powolny et al (2011), Seifert et al (2012), Gundacker et al (2013), Nemallapudi et al (2015), Gundacker et al (2016a), Cates and Levin (2016).”
BackgroundPowolny, F., Auffray, E., Brünner, S., Garutti, E., Goettlich, M., Hillemanns, H., Jarron, P., Lecoq, P. R., Meyer, T., Schultz-Coulon, H.-C., et al. (2011) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2011.2119493 · Cited by 103
Advances in digital SiPMs and their application in biomedical imaging
Schaart, D. R., Edoardo Charbon, A., Frach, T., & Schulz, V. (2015) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2015.10.078 · Cited by 101 · cited 1×
“Further reading on the digital SiPM can be found e.g. in the excellent review paper (Schaart et al 2016).”
BackgroundPushing Cherenkov PET with BGO via coincidence time resolution classification and correction
Kratochwil, N., Gundacker, S., Lecoq, P. R., & Auffray, E. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab87f9 · Cited by 101 · cited 1×
“Nevertheless much attention is given to BGO and many groups performed extended studies on it (Brunner and Schaart 2017, Kwon et al 2016, Cates and Levin 2019, Gundacker et al 2020, Kratochwil et al 2020).”
BackgroundSelf-citationBismuth germanate coupled to near ultraviolet silicon photomultipliers for time-of-flight PET
Kwon, S. I., Gola, A. G., Ferri, A., Piemonte, C., & Cherry, S. R. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/18/l38 · Cited by 94 · cited 1×
“Nevertheless much attention is given to BGO and many groups performed extended studies on it (Brunner and Schaart 2017, Kwon et al 2016, Cates and Levin 2019, Gundacker et al 2020, Kratochwil et al 2020).”
BackgroundMora, A. D. D., Martinenghi, E., Contini, D., Tosi, A., Boso, G., Durduran, T., Arridge, S., Martelli, F., Farina, A., Torricelli, A. M., et al. (2015) · Optics Express · doi:10.1364/oe.23.013937 · Cited by 75
Zimmermann, R., Braun, F., Achtnich, T., Lambercy, O., Gassert, R., & Wolf, M. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.000659 · Cited by 68
Electronics method to advance the coincidence time resolution with bismuth germanate
Cates, J. W., & Levin, C. S. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab31e3 · Cited by 68 · cited 2×
“Nevertheless much attention is given to BGO and many groups performed extended studies on it (Brunner and Schaart 2017, Kwon et al 2016, Cates and Levin 2019, Gundacker et al 2020, Kratochwil et al 2020).”
BackgroundStudies on the Cherenkov Effect for Improved Time Resolution of TOF-PET
Brünner, S., Gruber, L., Marton, J., Suzuki, K., & Hirtl, A. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2013.2281667 · Cited by 66
Medical applications of silicon photomultipliers
Bisogni, M. G., Guerra, A. D., & Belcari, N. (2018) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2018.10.175 · Cited by 64 · cited 4×
“Hybrid systems combining SPECT with MR are rare, because SPECT has evolved to use different detectors like CdTe or CZT semiconductors for direct detection of the gamma rays (Bisogni et al 2019).”
BackgroundMethodInfluentialSilicon Photomultipliers and SPAD imagers in biophotonics: Advances and perspectives
Caccia, M., Nardo, L., Santoro, R., & Schaffhauser, D. (2018) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2018.10.204 · Cited by 58 · cited 1×
“Typical fields are time correlated single photon counting in physics (Moses 1993, Brunner and Schaart 2017, Gundacker et al 2018) and biology (Caccia et al 2019).”
BackgroundFast Self Triggered Multi Channel Readout ASIC for Time- and Energy Measurement
Fischer, P., Peric, I., Ritzert, M., & Koniczek, M. (2009) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2008.2008807 · Cited by 52
Re, R., Martinenghi, E., Mora, A. D. D., Contini, D., Pifferi, A., & Torricelli, A. M. (2016) · Neurophotonics · doi:10.1117/1.nph.3.4.045004 · Cited by 50
Degenhardt, C., Rodrigues, P., Trindade, A., Zwaans, B., Mülhens, O., Dorscheid, R., Thon, A., Salomon, A., & Frach, T. (2012) · 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC) · doi:10.1109/nssmic.2012.6551643 · Cited by 47
A Quantum Random Number Generator Based on the 100-Mbit/s Poisson Photocount Statistics
Balygin, K. A., Zaitsev, V. Y., Klimov, A. N., Kulik, S. P., & Molotkov, S. N. (2018) · Journal of Experimental and Theoretical Physics · doi:10.1134/s1063776118060018 · Cited by 33
Schug, D., Wehner, J., Dueppenbecker, P. M., Weissler, B., Gebhardt, P., Goldschmidt, B., Salomon, A., Kiessling, F. M., & Schulz, V. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/18/7045 · Cited by 30 · cited 1×
“Examples of successfull implementations of the d-SiPMs from Philips Digital Photon Counting into pre-clinical and clinical PET/MR systems was shown in (Weissler et al 2015, Schug et al 2015).”
MethodCombining endoscopic ultrasound with Time-Of-Flight PET: The EndoTOFPET-US Project
Frisch, B. (2013) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2013.05.027 · Cited by 28 · cited 1×
“As an example SiPMs were employed in the EndoTOFPET-US project, with the aim to built an endoscopic probe for pancreatic and prostate cancer, equiped with a PET head (Frisch 2013).”
MethodA comparative study of the time performance between NINO and FlexToT ASICs
Sarasola, I., Nemallapudi, M. V., Gundacker, S., Sánchez, D., Gascon, D., Mendes, P. R., Marin, J., & Auffray, E. (2017) · Journal of Instrumentation · doi:10.1088/1748-0221/12/04/p04016 · Cited by 26 · cited 1×
“Examples of ASICS using a current readout approach are the NINO ASIC (Powolny et al 2011, Anghinolfi et al 2004), STiC3 (Stankova et al 2015), FlexTOT (Comerma et al 2013, Sarasola et al 2017) and TOFPET2 (Francesco et al 2016).”
MethodSelf-citationSTIC3 – Silicon Photomultiplier Timing Chip with picosecond resolution
Stankova, V., Shen, W., Briggl, K., Chen, H., Fischer, P., Gil, A., Harion, T., Kiworra, V., Munwes, Y., Ritzert, M., et al. (2014) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2014.12.073 · Cited by 26 · cited 1×
“Examples of ASICS using a current readout approach are the NINO ASIC (Powolny et al 2011, Anghinolfi et al 2004), STiC3 (Stankova et al 2015), FlexTOT (Comerma et al 2013, Sarasola et al 2017) and TOFPET2 (Francesco et al 2016).”
MethodNolet, F., Lemaire, W., Dubois, F., Roy, N., Carrier, S., Samson, A., Charlebois, S. A., Fontaine, R., & Pratte, J. ‐. (2019) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2019.162891 · Cited by 24 · cited 1×
“Therefore newer research on the digital SiPM is moving in the direction of 3D assembling of the detector (Bérubé et al 2015, Nolet et al 2018, Nolet et al 2020).”
BackgroundPerformance of FBK SiPMs coupled to PETA3 read-out ASIC for PET application
Piemonte, C., Gola, A. G., Tarolli, A., Fisher, P., Ritzert, M., Schulz, V., & Solf, T. (2012) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2012.10.012 · Cited by 21 · cited 1×
“ASICs applying a voltage readout approach are for example SPIROC (Lorenzo et al 2013), EASIROC (Callier et al 2012), PETIROC (Fleury et al 2014) and PETA (Fischer et al 2009, Piemonte et al 2013).”
MethodMeasurement of photon correlations with multipixel photon counters
Kalashnikov, D. A., & Krivitsky, L. A. (2014) · Journal of the Optical Society of America B · doi:10.1364/josab.31.000b25 · Cited by 10
Metadata
- Authors
- Gundacker, S., & Heering, A.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2020-08-19
- Volume
- 65
- Issue
- 17
- Pages
- 17TR01
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W3007319830
- Cited by
- 237
- References
- 56
- FWCI
- 20.58
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.