Physics and biology of ultrahigh dose-rate (FLASH) radiotherapy: a topical review
The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
Ultrahigh dose-rate radiotherapy (RT), or ‘FLASH’ therapy, has gained significant momentum following various in vivo studies published since 2014 which have demonstrated a reduction in normal tissue toxicity and similar tumor control for FLASH-RT when compared with conventional dose-rate RT. Subsequent studies have sought to investigate the potential for FLASH normal tissue protection and the literature has been since been inundated with publications on FLASH therapies. Today, FLASH-RT is considered by some as having the potential to ‘revolutionize radiotherapy’. FLASH-RT is considered by some as having the potential to ‘revolutionize radiotherapy’. The goal of this review article is to present the current state of this intriguing RT technique and to review existing publications on FLASH-RT in terms of its physical and biological aspects. In the physics section, the current landscape of ultrahigh dose-rate radiation delivery and dosimetry is presented. Specifically, electron, photon and proton radiation sources capable of delivering ultrahigh dose-rates along with their beam delivery parameters are thoroughly discussed. Additionally, the benefits and drawbacks of radiation detectors suitable for dosimetry in FLASH-RT are presented. The biology section comprises a summary of pioneering in vitro ultrahigh dose-rate studies performed in the 1960s and early 1970s and continues with a summary of the recent literature investigating normal and tumor tissue responses in electron, photon and proton beams. The section is concluded with possible mechanistic explanations of the FLASH normal-tissue protection effect (FLASH effect). Finally, challenges associated with clinical translation of FLASH-RT and its future prospects are critically discussed; specifically, proposed treatment machines and publications on treatment planning for FLASH-RT are reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Compression of amplified chirped optical pulses
Strickland, D., & Mourou, G. (1985) · Optics Communications · doi:10.1016/0030-4018(85)90120-8 · Cited by 3,937
The novel object recognition memory: neurobiology, test procedure, and its modifications
Antunes, M., & Biala, G. (2012) · Cognitive Processing · doi:10.1007/s10339-011-0430-z · Cited by 2,390
A laser–plasma accelerator producing monoenergetic electron beams
Faure, J., Glinec, Y., Pukhov, A., Kiselev, S., Gordienko, S., Lefebvre, E., Rousseau, J.-P., Burgy, F., & Malka, V. (2004) · Nature · doi:10.1038/nature02963 · Cited by 2,129
High-quality electron beams from a laser wakefield accelerator using plasma-channel guiding
Geddes, C. G. R., Toth, C., van Tilborg, J., Esarey, E., Schroeder, C. B., Bruhwiler, D., Nieter, C., Cary, J., & Leemans, W. P. (2004) · Nature · doi:10.1038/nature02900 · Cited by 2,001
Monoenergetic beams of relativistic electrons from intense laser–plasma interactions
Mangles, S. P. D., Murphy, C. D., Najmudin, Z., Thomas, A. G. R., Collier, J. L., Dangor, A. E., Divall, E. J., Foster, P. S., Gallacher, J. G., Hooker, C. J., et al. (2004) · Nature · doi:10.1038/nature02939 · Cited by 1,977
One Hundred and Twenty-Seven Cultured Human Tumor Cell Lines Producing Tumors in Nude Mice23
Fogh, J., Fogh, J. M., & Orfeo, T. (1977) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/59.1.221 · Cited by 1,599
Favaudon, V., Caplier, L., Monceau, V., Pouzoulet, F., Sayarath, M., Fouillade, C., Poupon, M.-F., Brito, I., Hupé, P., Bourhis, J., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008973 · Cited by 1,476
Defining normoxia, physoxia and hypoxia in tumours—implications for treatment response
McKeown, S. R. (2014) · The British Journal of Radiology · doi:10.1259/bjr.20130676 · Cited by 1,050
Generation of ultrahigh peak power pulses by chirped pulse amplification
Maine, P., Strickland, D., Bado, P., Pessot, M., & Mourou, G. (1988) · IEEE Journal of Quantum Electronics · doi:10.1109/3.137 · Cited by 941
Controlled injection and acceleration of electrons in plasma wakefields by colliding laser pulses
Faure, J., Rechatin, C., Norlin, A., Lifschitz, A., Glinec, Y., & Malka, V. (2006) · Nature · doi:10.1038/nature05393 · Cited by 838
Montay-Gruel, P., Petersson, K., Jaccard, M., Boivin, G., Germond, J.-F., Petit, B., Doenlen, R., Favaudon, V., Bochud, F., Bailat, C., et al. (2017) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.05.003 · Cited by 692
Long-term neurocognitive benefits of FLASH radiotherapy driven by reduced reactive oxygen species
Montay-Gruel, P., Acharya, M. M., Petersson, K., Alikhani, L., Yakkala, C., Allen, B. D., Ollivier, J., Petit, B., Jorge, P. G., Syage, A. R., et al. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1901777116 · Cited by 599
Principles and applications of compact laser–plasma accelerators
Malka, V., Faure, J., Gauduel, Y. A., Lefebvre, E., Rousse, A., & Phuoc, K. T. (2008) · Nature Physics · doi:10.1038/nphys966 · Cited by 507
Biological Benefits of Ultra-high Dose Rate FLASH Radiotherapy: Sleeping Beauty Awoken
Vozenin, M.-C., Hendry, J. H., & Limoli, C. L. (2019) · Clinical Oncology · doi:10.1016/j.clon.2019.04.001 · Cited by 484
Clinical translation of FLASH radiotherapy: Why and how?
Bourhis, J., Montay-Gruel, P., Gonçalves Jorge, P., Bailat, C., Petit, B., Ollivier, J., Jeanneret-Sozzi, W., Ozsahin, M., Bochud, F., Moeckli, R., et al. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.04.008 · Cited by 474
Ultra-High Dose Rate (FLASH) Radiotherapy: Silver Bullet or Fool's Gold?
Wilson, J. D., Hammond, E. M., Higgins, G. S., & Petersson, K. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2019.01563 · Cited by 473
Montay-Gruel, P., Bouchet, A., Jaccard, M., Patin, D., Serduc, R., Aim, W., Petersson, K., Petit, B., Bailat, C., Bourhis, J., et al. (2018) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2018.08.016 · Cited by 405
MeV x-ray generation with a femtosecond laser
Kmetec, J. D., Gordon, C. L., Macklin, J. J., Lemoff, B. E., Brown, G. S., & Harris, S. E. (1992) · Physical Review Letters · doi:10.1103/physrevlett.68.1527 · Cited by 374
Spitz, D. R., Buettner, G. R., Petronek, M. S., St-Aubin, J. J., Flynn, R. T., Waldron, T. J., & Limoli, C. L. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.03.028 · Cited by 308
Biological effects in normal cells exposed to FLASH dose rate protons
Buonanno, M., Grilj, V., & Brenner, D. J. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.02.009 · Cited by 306
FLASH Irradiation Spares Lung Progenitor Cells and Limits the Incidence of Radio-induced Senescence
Fouillade, C., Curras-Alonso, S., Giuranno, L., Quelennec, E., Heinrich, S., Bonnet-Boissinot, S., Beddok, A., Leboucher, S., Karakurt, H. U., Bohec, M., et al. (2020) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-19-1440 · Cited by 303
Experimental Set-up for FLASH Proton Irradiation of Small Animals Using a Clinical System
Patriarca, A., Fouillade, C., Auger, M., Martin, F., Pouzoulet, F., Nauraye, C., Heinrich, S., Favaudon, V., Meyroneinc, S., Dendale, R., et al. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.06.403 · Cited by 284
Simmons, D. A., Lartey, F. M., Schüler, E., Rafat, M., King, G., Kim, A., Ko, R., Semaan, S., Gonzalez, S., Jenkins, M., et al. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.06.006 · Cited by 278
The FLASH effect depends on oxygen concentration
Adrian, G., Konradsson, E., Lempart, M., Bäck, S., Ceberg, C., & Petersson, K. (2020) · The British Journal of Radiology · doi:10.1259/bjr.20190702 · Cited by 245
Evaluation of Gafchromic® EBT3 films characteristics in therapy photon, electron and proton beams
Sorriaux, J., Kacperek, A., Rossomme, S., Lee, J. A., Bertrand, D., Vynckier, S., & Sterpin, E. (2013) · Physica Medica · doi:10.1016/j.ejmp.2012.10.001 · Cited by 236
Faster and safer? FLASH ultra-high dose rate in radiotherapy
Durante, M., Brauer-Krisch, E., & Hill, M. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20170628 · Cited by 220
Relativistic electron beams driven by kHz single-cycle light pulses
Guénot, D., Gustas, D., Vernier, A., Beaurepaire, B., Böhle, F., Bocoum, M., Lozano, M., Jullien, A., Lopez-Martens, R., Lifschitz, A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2017.46 · Cited by 197
Serduc, R., Vérant, P., Vial, J., Farion, R., Rocas, L., Rémy, C., Fadlallah, T., Bräuer‐Krisch, E., Bravin, A., Laissue, J. A., et al. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.11.047 · Cited by 187
Pittman, M., Ferré, S., Rousseau, J. P., Notebaert, L., Chambaret, J. P., & Chériaux, G. (2002) · Applied Physics B · doi:10.1007/s003400200838 · Cited by 170
Pratx, G., & Kapp, D. S. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab3769 · Cited by 170
Yogo, A., Sato, K., Nishikino, M., Mori, M., Teshima, T., Numasaki, H., Murakami, M., Demizu, Y., Akagi, S., Nagayama, S., et al. (2009) · Applied Physics Letters · doi:10.1063/1.3126452 · Cited by 132
Sharplin, J., & Franko, A. J. (1989) · Radiation Research · doi:10.2307/3577364 · Cited by 130
Yogo, A., Maeda, T., Hori, T., Sakaki, H., Ogura, K., Nishiuchi, M., Sagisaka, A., Kiriyama, H., Okada, H., Kanazawa, S., et al. (2011) · Applied Physics Letters · doi:10.1063/1.3551623 · Cited by 117
Dose-controlled irradiation of cancer cells with laser-accelerated proton pulses
Zeil, K., Baumann, M. A., Beyreuther, E., Burris-Mog, T., Cowan, T. E., Enghardt, W., Karsch, L., Kraft, S., Laschinsky, L., Metzkes-Ng, J., et al. (2012) · Applied Physics B · doi:10.1007/s00340-012-5275-3 · Cited by 114
Zlobinskaya, O., Siebenwirth, C., Greubel, C., Hable, V., Hertenberger, R., Humble, N., Reinhardt, S. C. M., Michalski, D., Röper, B., Multhoff, G., et al. (2014) · Radiation Research · doi:10.1667/rr13464.1 · Cited by 113
Favaudon, V., TOURBEZ, H., Houée‐Levin, C., & Lhoste, J. M. (1990) · Biochemistry · doi:10.1021/bi00501a016 · Cited by 112
Sharplin, J., & Franko, A. J. (1989) · Radiation Research · doi:10.2307/3577363 · Cited by 109
Glinec, Y., Faure, J., Malka, V. A., Fuchs, T., Szymanowski, H., & Oelfke, U. (2005) · Medical Physics · doi:10.1118/1.2140115 · Cited by 104
Stevenson, A. W., Crosbie, J. C., Hall, C. J., Häusermann, D. M., Livingstone, J., & Lye, J. (2016) · Journal of Synchrotron Radiation · doi:10.1107/s1600577516015563 · Cited by 102
Jackson, I. L., Vujašković, Ž., & Down, J. D. (2009) · Radiation Research · doi:10.1667/rr1911.1 · Cited by 101
Ultra-High-Dose-Rate FLASH Irradiation May Spare Hypoxic Stem Cell Niches in Normal Tissues
Pratx, G., & Kapp, D. S. (2019) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2019.05.030 · Cited by 94
Subiel, A., Moskvin, V. P., Welsh, G. H., et al. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/19/5811 · Cited by 69
High-charge relativistic electron bunches from a kHz laser-plasma accelerator
Gustas, D., Guénot, D., Vernier, A., Dutt, S., Böhle, F., López-Martens, R., Lifschitz, A. F., & Faure, J. (2018) · Physical Review Accelerators and Beams · doi:10.1103/physrevaccelbeams.21.013401 · Cited by 63
Bazalova‐Carter, M., Liu, M. B., Palma, B., Dunning, M., McCormick, D., Hemsing, E., Nelson, J. L., Jobe, K., Colby, E. R., Koong, A. C., et al. (2015) · Medical Physics · doi:10.1118/1.4914371 · Cited by 62
Self-citationLaser electron accelerators for radiation medicine: A feasibility study
Chiu, C. B., Fomyts’kyi, M. V., Grigsby, F., Raischel, F., Downer, M. C., & Tajima, T. (2004) · Medical Physics · doi:10.1118/1.1739301 · Cited by 52
Schmid, T. E., Dollinger, G., Hable, V., Greubel, C., Zlobinskaya, O., Michalski, D., Auer, S., Friedl, A. A., Schmid, E. W., Molls, M., et al. (2011) · Radiation Research · doi:10.1667/rr2465.1 · Cited by 51
Under-response correction for EBT3 films in the presence of proton spread out Bragg peaks
Fiorini, F., Kirby, D., Thompson, J. M., Green, S., Parker, D. J., Jones, B., & Hill, M. A. (2014) · Physica Medica · doi:10.1016/j.ejmp.2013.12.006 · Cited by 51
Generation of quasi-monoenergetic electron beams using ultrashort and ultraintense laser pulses
Glinec, Y., Faure, J., Pukhov, A., KISELEV, S., Gordienko, S. N., Mercier, B., & Malka, V. A. (2005) · Laser and Particle Beams · doi:10.1017/s0263034605050275 · Cited by 51
Towards ion beam therapy based on laser plasma accelerators
Karsch, L., Beyreuther, E., Enghardt, W., Gotz, M. D., Masood, U., Schramm, U., Zeil, K., & Pawelke, J. (2017) · Acta Oncologica · doi:10.1080/0284186x.2017.1355111 · Cited by 51
Lundh, O., Rechatin, C., Faure, J., Ben-Ismail, A., Lim, J., Wagter, C. D., Neve, W. D., & Malka, V. A. (2012) · Medical Physics · doi:10.1118/1.4719962 · Cited by 50
Dose properties of a laser accelerated electron beam and prospects for clinical application
Kainz, K. K., Hogstrom, K. R., Antolak, J. A., Almond, P. R., Bloch, C., Chiu, C., Fomyts’kyi, M. V., Raischel, F., Downer, M. C., & Tajima, T. (2004) · Medical Physics · doi:10.1118/1.1690194 · Cited by 49
Tillman, C., Grafström, G., Jönsson, A.-C., Jönsson, B.-A., Mercer, I. P., Mattsson, S., Strand, S., & Svanberg, S. R. (1999) · Radiology · doi:10.1148/radiology.213.3.r99dc13860 · Cited by 48
FLASH radiotherapy: Newsflash or flash in the pan?
Maxim, P. G., Keall, P., & Cai, J. (2019) · Medical Physics · doi:10.1002/mp.13685 · Cited by 48
Beyreuther, E., Enghardt, W., Kaluza, M. C., et al. (2010) · Medical Physics · doi:10.1118/1.3301598 · Cited by 40
Das, T. N., Ghanty, T. K., & Pal, H. (2003) · The Journal of Physical Chemistry A · doi:10.1021/jp022614r · Cited by 35
Hill, M. A., Stevens, D. L., Marsden, S. J., Allott, R. M., Turcu, I. C. E., & GOODHEAD, D. T. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/19/308 · Cited by 31
Assessment of optical CT as a future QA tool for synchrotron x-ray microbeam therapy
McErlean, C. M., Bräuer‐Krisch, E., Adamovics, J. A., & Doran, S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/1/320 · Cited by 27
The role of a microDiamond detector in the dosimetry of proton pencil beams
Gomà, C., Marinelli, M., Safai, S., et al. (2015) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2015.08.003 · Cited by 26
Optimization of an on‐board imaging system for extremely rapid radiation therapy
Cherry, E. M., Wu, M., Yang, H., Maxim, P. G., Loo, B. W., & Fahrig, R. (2015) · Medical Physics · doi:10.1118/1.4934377 · Cited by 7
Monte Carlo calculated kilovoltage x-ray arc therapy plans for three lung cancer patients
Breitkreutz, D. Y., Renaud, M., Weil, M., Zavgorodni, S., Han, J., Baxter, H., Seuntjens, J. P., Song, S. M.-H., Boyd, D. P., & Bazalova‐Carter, M. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab4dc5 · Cited by 7
Self-citation
Cited by
Does FLASH deplete oxygen? Experimental evaluation for photons, protons, and carbon ions
Jansen, J., Knoll, J., Beyreuther, E., Pawelke, J., Skuza, R., Hanley, R., Brons, S., Pagliari, F., & Seco, J. (2021) · Medical Physics · doi:10.1002/mp.14917 · Cited by 164
Metadata
- Authors
- Esplen, N., Mendonca, M. S., & Bazalova-Carter, M.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2020-12-01
- Volume
- 65
- Issue
- 23
- Pages
- 23TR03
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W3045635238
- Cited by
- 270
- References
- 60
- FWCI
- 22.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.