A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Open accessThe DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
We have measured the absolute frequency of the optical lattice clock based on 87 Sr at PTB with an uncertainty of using two caesium fountain clocks. This is close to the accuracy of todayʼs best realizations of the SI second. The absolute frequency of the 5 s 2 1 S 0 – 5s5p 3 P 0 transition in 87 Sr is .13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach , opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy or optical clock evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This international all-optical clock measurement surpasses the accuracy of the best possible comparison achievable by measurements against primary caesium clocks by one order of magnitude5212223.”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [21]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Several optical frequency ratio measurements as well as independent absolute frequency measurements of optical lattice clocks have been made locally at the following NMIs”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [166]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The accuracy of the former method is limited by the caesium microwave clocks with the most stringent bound set by our groups5212223 at an agreement within 4 × 10−16”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [21]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Today, several groups operate transportable optical clocks [16, 17, 25-31].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [31]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The details of the actual implementation of state preparation and interrogation being quite different in the two experimental realizations of a Sr lattice clock5212223, systematic and statistical uncertainties are highly independent and uncorrelated.”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [21]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
Standard, S. (2006) · Cited by 6,460
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · cited 4×
“In addition to their role as future primary standards, optical clocks are of interest as sensitive probes in areas such as relativistic geodesy [9], tests of relativity [10, 11], and searches for variations of fundamental constants [1, 12, 13, 14, 15].”
BackgroundInfluentialAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073 · cited 4×
“However, a recent study placed strontium lattice clocks into the accuracy regime of the best ion clocks [22].”
BackgroundInfluentialFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Self-citationA sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Self-citationUltrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572
Sr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554
Self-citation
Cited by
Items 201–216 of 216
Yingxin, 陈. C., Lu, X., & Chang, H. (2023) · Acta Optica Sinica · doi:10.3788/aos230444
Hogan, P. A., & Puetzfeld, D. (2021) · Lecture notes in physics · doi:10.1007/978-3-030-69370-1_5
Operation and optical frequency comparisons with an ytterbium optical lattice clock
Condio, S. (2025) · PORTO@Iris · doi:10.13121/polito/porto/3002616
Optical Signals Synthesized from an Optical Lattice Clock with Uncertainty of 1.3E-17Preprint
Yao, Y., Jinpeng, Z., Shi, H., Yu, H., Ma, L., & Jiang, Y. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2610.11178
HUANG, 黄. Y., LEI, 雷. Y., Qi, J., ZHANG, 张. X., WANG, 王. J., & WU, 武. H. (2026) · Acta Sinica Quantum Optica · doi:10.3788/jqo20263202.0601
Design and implementation of a modular laser system for AMO experimentsPreprint
Theophilo, K., Thomas, S., Croft, G., Lekhai, Y., Owens, A., Smith, D. S., Muralidharan, S., & Deans, C. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2603.17697
Photoassociation of 40Ca at high laser intensities
Dahlke, V. P. (2020) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/9856
Hochauflösende Spektroskopie und Stabilitätsanalyse eines Magnesium-Frequenzstandards
Zipfel, K. (2019) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/4548
Atom interferometry for tests of general relativity
Fard, L. (2020) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/10142
Lachmann, K. E., Müller, J., Vollmair, P., & Schlicht, A. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2609.21786
Quantum simulator for spin-orbital magnetism
Bühler, A. (2015) · OPUS Publication Server of the University of Stuttgart (University of Stuttgart) · doi:10.18419/opus-8727
Sub-kHz linewidth free-running monolithic cavity VECSEL with 10⁻¹² stabilityPreprint
Moriya, P. H., Lee, M., & Hastie, J. E. (2024) · doi:10.1364/opticaopen.25480285.v1
One and two-color photoassociation spectroscopy of ultracold 40Ca
Pachomow, E. (2017) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/9035
Supporting information 1 of Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · doi:10.1364/optica.3.000563.s001
Self-citation
Metadata
- Authors
- Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., Vogt, S., Sterr, U., & Lisdat, C.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Corresponding author
- Grebing, Christian
- Hagemann, Christian
- Lisdat, Christian
- Venue
- New Journal of Physics
- Publisher
- IOP Publishing
- Published
- 2014-07-17
- Volume
- 16
- Issue
- 7
- Pages
- 073023
- ISSN
- 1367-2630 (ISSN-L)
- OpenAlex
- W1969928411
- Semantic Scholar
- d109d54b2516d8e6592a83228e183d05552a9a4b
- Cited by
- 182
- References
- 76
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 10 · 2023: 15 · 2022: 14 · 2021: 7 · 2020: 11 · 2019: 14 · 2018: 20 · 2017: 16 · 2016: 29 · 2015: 29 · 2014: 10
- FWCI
- 13.88
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- creativecommons.org/licenses/by/3.0/ (vor)
- Locations
- New Journal of Physics (publishedVersion, cc-by)
- arXiv (Cornell University) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- arXiv (Cornell University)
- Funders
- Pennsylvania State University
- European Association of National Metrology Institutes
- Deutsche Forschungsgemeinschaft (RTG 1729)
- Leibniz-Gemeinschaft
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- 87Sr, optical lattice clock, absolute frequency measurement, frequency standards, systematic uncertainties, SI second, frequency ratio measurement, optical clocks
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.