A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Open accessThe DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
We have measured the absolute frequency of the optical lattice clock based on 87 Sr at PTB with an uncertainty of using two caesium fountain clocks. This is close to the accuracy of todayʼs best realizations of the SI second. The absolute frequency of the 5 s 2 1 S 0 – 5s5p 3 P 0 transition in 87 Sr is .13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach , opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy or optical clock evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This international all-optical clock measurement surpasses the accuracy of the best possible comparison achievable by measurements against primary caesium clocks by one order of magnitude5212223.”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [21]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Several optical frequency ratio measurements as well as independent absolute frequency measurements of optical lattice clocks have been made locally at the following NMIs”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [166]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The accuracy of the former method is limited by the caesium microwave clocks with the most stringent bound set by our groups5212223 at an agreement within 4 × 10−16”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [21]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Today, several groups operate transportable optical clocks [16, 17, 25-31].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [31]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The details of the actual implementation of state preparation and interrogation being quite different in the two experimental realizations of a Sr lattice clock5212223, systematic and statistical uncertainties are highly independent and uncorrelated.”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [21]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
Standard, S. (2006) · Cited by 6,460
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · cited 4×
“In addition to their role as future primary standards, optical clocks are of interest as sensitive probes in areas such as relativistic geodesy [9], tests of relativity [10, 11], and searches for variations of fundamental constants [1, 12, 13, 14, 15].”
BackgroundInfluentialAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073 · cited 4×
“However, a recent study placed strontium lattice clocks into the accuracy regime of the best ion clocks [22].”
BackgroundInfluentialFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Self-citationA sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Self-citationUltrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572
Sr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554
Self-citation
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Ultralow-noise mode-locked fiber lasers and frequency combs: principles, status, and applications
Kim, J., & Song, Y. (2016) · Advances in Optics and Photonics · doi:10.1364/aop.8.000465 · Cited by 567
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Self-citationGodun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
A clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460
“By counting the rf (radio frequency) beat-note signals of the lasers with the frequency combs, the optical frequency ratios between each Sr clock and the associated transfer laser are determined accurately with less than 10 −18 uncertainty (7,19).”
BackgroundInfluentialSelf-citationA Fermi-degenerate three-dimensional optical lattice clock
Campbell, S. L., Hutson, R. B., Marti, G. E., Goban, A., Darkwah Oppong, N., McNally, R. L., Sonderhouse, L., Robinson, J. M., Zhang, W., Bloom, B. J., et al. (2017) · Science · doi:10.1126/science.aam5538 · Cited by 384
“554499(8) THz, respectively, in agreement with [125, 59, 149].”
BackgroundMethodInfluentialImproved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Self-citation8 × 10^−17 fractional laser frequency instability with a long room-temperature cavity
Häfner, S., Falke, S., Grebing, C., Vogt, S., Legero, T., Merimaa, M., Lisdat, C., & Sterr, U. (2015) · Optics Letters · doi:10.1364/ol.40.002112 · Cited by 286
“0 of 50 mK, these frequency deviations correspond to temperature fluctuations of ±120 µK. 3 This resonator setup is the central part of the interrogation laser system for a 87Sr optical lattice clock [13]. The frequency of a filter-stabilized 698nm extendedcavity laser diode [19, 20] is locked via the PoundDrever-Hall (…”
BackgroundMethodSelf-citationThe CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“Such measurements are typically limited by the accuracy of the Cs fountain clocks to a few parts in 1016 (Campbell et al., 2008; Falke et al., 2014; Huntemann et al., 2014; Kim et al., 2017; Oskay et al., 2006; Pizzocaro et al., 2017; Tamm et al., 2014, Le Targat et al., 2013).”
Self-citationTransportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238
Self-citationTest of Special Relativity Using a Fiber Network of Optical Clocks
Delva, P., Lodewyck, J., Bilicki, S., Bookjans, E., Vallet, G., Le Targat, R., Pottie, P.-E., Guerlin, C., Meynadier, F., Le Poncin-Lafitte, C., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.221102 · Cited by 227
Self-citationFrequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221
Towards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
High Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.263004 · Cited by 154
Self-citationRealization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Self-citationAtomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty
Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M., Oates, C. W., & Ludlow, A. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.260801 · Cited by 137
Towards the optical second: verifying optical clocks at the SI limit
McGrew, W. F., Zhang, X., Leopardi, H., Fasano, R. J., Nicolodi, D., Beloy, K., Yao, J., Sherman, J. A., Schäffer, S. A., Savory, J., et al. (2019) · Optica · doi:10.1364/optica.6.000448 · Cited by 135
Filzinger, M., Dörscher, S., Lange, R., Klose, J., Steinel, M., Benkler, E., Peik, E., Lisdat, C., & Huntemann, N. (2023) · Physical Review Letters · doi:10.1103/physrevlett.130.253001 · Cited by 133
Self-citationBelenchia, A., Carlesso, M., Bayraktar, Ö., Dequal, D., Derkach, I. D., Gasbarri, G., Herr, W., Li, Y. L., Rademacher, M., Sidhu, J. S., et al. (2022) · Physics Reports · doi:10.1016/j.physrep.2021.11.004 · Cited by 129
Schioppo, M., Kronjäger, J., Silva, A., Ilieva, R., Paterson, J. W., Baynham, C. F. A., Bowden, W., Hill, I. R., Hobson, R., Vianello, A., et al. (2022) · Nature Communications · doi:10.1038/s41467-021-27884-3 · Cited by 118
Self-citationFrequency Comparison of TwoCa+40Optical Clocks with an Uncertainty at the10−17Level
Huang, Y., Guan, H., Liu, P., Bian, W., Ma, L., Liang, K., Li, T., & Gao, K. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.013001 · Cited by 106
Frequency Ratio ofHg199andSr87Optical Lattice Clocks beyond the SI Limit
Yamanaka, K., Ohmae, N., Ushijima, I., Takamoto, M., & Katori, H. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.230801 · Cited by 104
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102
Hyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock
Brown, R. C., Phillips, N. B., Beloy, K., McGrew, W. F., Schioppo, M., Fasano, R. J., Milani, G., Zhang, X., Hinkley, N., Leopardi, H., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.253001 · Cited by 101
Testing physics beyond the standard model through additional clock transitions in neutral ytterbium
Dzuba, V. A., Flambaum, V. V., & Schiller, S. (2018) · Physical Review A · doi:10.1103/physreva.98.022501 · Cited by 91
Comparing a mercury optical lattice clock with microwave and optical frequency standards
Tyumenev, R., Favier, M., Bilicki, S., Bookjans, E., Targat, R. L., Lodewyck, J., Nicolodi, D., Coq, Y. L., Abgrall, M., Guéna, J., et al. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/11/113002 · Cited by 85
Frequency ratios of Sr, Yb, and Hg based optical lattice clocks and their applications
Takamoto, M., Ushijima, I., Das, M., Nemitz, N., Ohkubo, T., Yamanaka, K., Ohmae, N., Takano, T., Akatsuka, T., Yamaguchi, A., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.04.003 · Cited by 85
Noise and instability of an optical lattice clock
Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2015) · Physical Review A · doi:10.1103/physreva.92.063814 · Cited by 84
Self-citationOptical frequency standards for time and length applications
Hong, F.-L. (2017) · Measurement Science and Technology · doi:10.1088/1361-6501/28/1/012002 · Cited by 82
Ultrastable laser with average fractional frequency drift rate below 5 × 10^−19/s
Hagemann, C., Grebing, C., Lisdat, C., Falke, S., Legero, T., Sterr, U., Riehle, F., Martin, M. J., & Ye, J. (2014) · Optics Letters · doi:10.1364/ol.39.005102 · Cited by 77
Self-citationMorzyński, P., Bober, M., Bartoszek-Bober, D., Nawrocki, J., Krehlik, P., Śliwczyński, Ł., Lipiński, M., Masłowski, P., Cygan, A., Dunst, P., et al. (2015) · Scientific Reports · doi:10.1038/srep17495 · Cited by 77
Atomic source selection in space-borne gravitational wave detection
Loriani, S., Schlippert, D., Schubert, C., Abend, S., Ahlers, H., Ertmer, W. A., Rudolph, J., Hogan, J. M., Kasevich, M. A., Rasel, E. M., et al. (2019) · New Journal of Physics · doi:10.1088/1367-2630/ab22d0 · Cited by 69
Kobayashi, T., Takamizawa, A., Akamatsu, D., Kawasaki, A., Nishiyama, A., Hosaka, K., Hisai, Y., Wada, M., Inaba, H., Tanabe, T., et al. (2022) · Physical Review Letters · doi:10.1103/physrevlett.129.241301 · Cited by 66
First Evaluation and Frequency Measurement of the Strontium Optical Lattice Clock at NIM
Lin, Y.-G., Wang, Q., Li, Y., Meng, F., Lin, B.-K., Zang, E.-J., Sun, Z., Fang, F., Li, T.-C., & Fang, Z.-J. (2015) · Chinese Physics Letters · doi:10.1088/0256-307x/32/9/090601 · Cited by 65
Long term measurement of theSr87clock frequency at the limit of primary Cs clocks
Schwarz, R., Dörscher, S., Al-Masoudi, A., Benkler, E., Legero, T., Sterr, U., Weyers, S., Rahm, J., Lipphardt, B., & Lisdat, C. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033242 · Cited by 64
Self-citationKulosa, A. P., Fim, D., Zipfel, K. H., Rühmann, S., Sauer, S., Jha, N., Gibble, K., Ertmer, W., Rasel, E. M., Safronova, M. S., et al. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.240801 · Cited by 64
Pizzocaro, M., Bregolin, F., Barbieri, P., Rauf, B., Levi, F., & Calonico, D. (2020) · Metrologia · doi:10.1088/1681-7575/ab50e8 · Cited by 63
Cold atoms in space: community workshop summary and proposed road-map
Alonso, I., Alpigiani, C., Altschul, B., Araújo, H. M., Arduini, G., Arlt, J., Badurina, L., Balaž, A., Bandarupally, S., Barish, B. C., et al. (2022) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-022-00147-w · Cited by 61
Lattice-induced photon scattering in an optical lattice clock
Dörscher, S., Schwarz, R., Al-Masoudi, A., Falke, S., Sterr, U., & Lisdat, C. (2018) · Physical Review A · doi:10.1103/physreva.97.063419 · Cited by 60
Self-citationHobson, R., Bowden, W., Vianello, A., Silva, A., Baynham, C. F. A., Margolis, H. S., Baird, P. E. G., Gill, P., & Hill, I. R. (2020) · Metrologia · doi:10.1088/1681-7575/abb530 · Cited by 60
Additively manufactured ultra-high vacuum chamber for portable quantum technologies
Cooper, N., Coles, L. A., Everton, S. K., Maskery, I., Campion, R. P., Madkhaly, S., Morley, C. P., O’Shea, J. N., Evans, W. D., Saint, R., et al. (2021) · Additive manufacturing · doi:10.1016/j.addma.2021.101898 · Cited by 58
Long-term stable optical cavity for special relativity tests in space
Sanjuán, J., Abich, K., Gohlke, M., Resch, A., Schuldt, T., Wegehaupt, T., Barwood, G. P., Gill, P., & Braxmaier, C. (2019) · Optics Express · doi:10.1364/oe.27.036206 · Cited by 56
A pyramid MOT with integrated optical cavities as a cold atom platform for an optical lattice clock
Bowden, W., Hobson, R., Hill, I. R., Vianello, A., Schioppo, M., Silva, A., Margolis, H. S., Baird, P. E. G., & Gill, P. (2019) · Scientific Reports · doi:10.1038/s41598-019-48168-3 · Cited by 55
Hachisu, H., Petit, G., Nakagawa, F., Hanado, Y., & Ido, T. (2017) · Optics Express · doi:10.1364/oe.25.008511 · Cited by 53
Direct comparison of optical lattice clocks with an intercontinental baseline of 9000 km
Hachisu, H., Fujieda, M., Nagano, S., Gotoh, T., Nogami, A., Ido, T., Falke, S., Huntemann, N., Grebing, C., Lipphardt, B., et al. (2014) · Optics Letters · doi:10.1364/ol.39.004072 · Cited by 53
Self-citationOptical frequency ratio of a 171Yb+ single-ion clock and a 87Sr lattice clock
Dörscher, S., Huntemann, N., Schwarz, R., Lange, R., Benkler, E., Lipphardt, B., Sterr, U., Peik, E., & Lisdat, C. (2021) · Metrologia · doi:10.1088/1681-7575/abc86f · Cited by 53
Self-citationAtomic fountains and optical clocks at SYRTE: Status and perspectives
Abgrall, M., Chupin, B., De Sarlo, L., Guéna, J., Laurent, P., Le Coq, Y., Le Targat, R., Lodewyck, J., Lours, M., Rosenbusch, P., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.010 · Cited by 53
Fibre-optic delivery of time and frequency to VLBI station
Krehlik, P., Buczek, Ł., Kołodziej, J., Lipiński, M., Śliwczyński, Ł., Nawrocki, J., Nogaś, P., Marecki, A., Pazderski, E., Ablewski, P., et al. (2017) · Astronomy and Astrophysics · doi:10.1051/0004-6361/201730615 · Cited by 51
Absolute frequency measurement of the 171Yb optical lattice clock at KRISS using TAI for over a year
Kim, H., Heo, M.-S., Park, C. Y., Yu, D.-H., & Lee, W.-K. (2021) · Metrologia · doi:10.1088/1681-7575/ac1950 · Cited by 51
Terahertz Vibrational Molecular Clock with Systematic Uncertainty at the 10−14 Level
Leung, K. H., Iritani, B., Tiberi, E., Majewska, I., Borkowski, M., Moszyński, R., & Zelevinsky, T. (2023) · Physical Review X · doi:10.1103/physrevx.13.011047 · Cited by 50
Intermittent optical frequency measurements to reduce the dead time uncertainty of frequency link
Hachisu, H., & Ido, T. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.112401 · Cited by 48
The CIPM list ‘Recommended values of standard frequencies’: 2021 update
Margolis, H. S., Panfilo, G., Petit, G., Oates, C. W., Ido, T., & Bize, S. (2024) · Metrologia · doi:10.1088/1681-7575/ad3afc · Cited by 48
Floquet Engineering Hz-Level Rabi Spectra in Shallow Optical Lattice Clock
Yin, M.-J., Lu, X., Li, T., Xia, J., Wang, T., Zhang, X., & Chang, H. (2022) · Physical Review Letters · doi:10.1103/physrevlett.128.073603 · Cited by 46
Optical frequency transfer via a 660 km underground fiber link using a remote Brillouin amplifier
Raupach, S. M. F., Koczwara, A., & Grosche, G. (2014) · Optics Express · doi:10.1364/oe.22.026537 · Cited by 45
Guidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertaintyPreprint
Hafiz, M. A., Ablewski, P., Al-Masoudi, A., Martínez, H. Á., Balling, P., Barwood, G. P., Benkler, E., Bober, M., Borkowski, M., Bowden, W., et al. (2019) · arXiv · doi:10.15488/5553 · Cited by 45
Self-citationThermometry via Light Shifts in Optical Lattices
McDonald, M., McGuyer, B. H., Iwata, G. Z., & Zelevinsky, T. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.023001 · Cited by 43
A 87 Sr optical lattice clock with 2.9 × 10 − 17 uncertainty and its absolute frequency measurement
Lin, Y., Wang, Q., Meng, F., Cao, S., Wang, Y., Li, Y., Sun, Z. G., Lu, B.-K., Yang, T., Lin, B.-K., et al. (2021) · Metrologia · doi:10.1088/1681-7575/abf33e · Cited by 42
Margolis, H. S., & Gill, P. (2015) · Metrologia · doi:10.1088/0026-1394/52/5/628 · Cited by 40
Bober, M., Morzyński, P., Cygan, A., Lisak, D., Masłowski, P., Prymaczek, M., Wcisło, P., Ablewski, P., Piwiński, M., Wójtewicz, S., et al. (2015) · Measurement Science and Technology · doi:10.1088/0957-0233/26/7/075201 · Cited by 39
Kim, H., Heo, M.-S., Lee, W.-K., Park, C. Y., Hong, H.-G., Hwang, S.-W., & Yu, D.-H. (2017) · Japanese Journal of Applied Physics · doi:10.7567/jjap.56.050302 · Cited by 38
Polarizabilities of theSr87clock transition
Shi, C., Robyr, J.-L., Eismann, U., Zawada, M., Lorini, L., Le Targat, R., & Lodewyck, J. (2015) · Physical Review A · doi:10.1103/physreva.92.012516 · Cited by 37
Performance-Optimized Components for Quantum Technologies via Additive Manufacturing
Madkhaly, S. H., Coles, L. A., Morley, C., Colquhoun, C. D., Fromhold, T. M., Cooper, N., & Hackermüller, L. (2021) · PRX Quantum · doi:10.1103/prxquantum.2.030326 · Cited by 37
Studying the fundamental limit of optical fiber links to the 10−21 level
Xu, D., Lee, W.-K., Stefani, F., Lopez, O., Amy-Klein, A., & Pottie, P.-E. (2018) · Optics Express · doi:10.1364/oe.26.009515 · Cited by 35
Takano, T., Mizushima, R., & Katori, H. (2017) · Applied Physics Express · doi:10.7567/apex.10.072801 · Cited by 35
Two-Color Grating Magneto-Optical Trap for Narrow-Line Laser Cooling
Bondza, S., Lisdat, C., Kroker, S., & Leopold, T. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.044002 · Cited by 34
Self-citationLong-distance chronometric leveling with a portable optical clock
Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.l061001 · Cited by 33
“In a local measurement, two transportable lattice clocks were used to measure the gravitational red-shift induced by 450 m of height difference at the Tokyo Skytree and achieved a height resolution of about 4 cm FIG.”
Self-citationLu, B.-K., Sun, Z. G., Yang, T., Lin, Y., Wang, Q., Li, Y., Meng, F., Lin, B.-K., Li, T., & Fang, Z. (2022) · Chinese Physics Letters · doi:10.1088/0256-307x/39/8/080601 · Cited by 33
Hachisu, H., Petit, G., & Ido, T. (2017) · Applied Physics B · doi:10.1007/s00340-016-6603-9 · Cited by 31
Subrecoil Clock-Transition Laser Cooling Enabling Shallow Optical Lattice Clocks
Zhang, X., Beloy, K., Hassan, Y. S., McGrew, W. F., Chen, C.-C., Siegel, J. L., Grogan, T., & Ludlow, A. D. (2022) · Physical Review Letters · doi:10.1103/physrevlett.129.113202 · Cited by 30
Synthetic frequency protocol for Ramsey spectroscopy of clock transitions
Yudin, V. I., Taǐchenachev, A. V., Basalaev, M. Y., & Zanon-Willette, T. (2016) · Physical Review A · doi:10.1103/physreva.94.052505 · Cited by 29
Midinfrared magneto-optical trap of metastable strontium for an optical lattice clock
Hobson, R., Bowden, W., Vianello, A., Hill, I. R., & Gill, P. (2020) · Physical Review A · doi:10.1103/physreva.101.013420 · Cited by 29
Chronometric Geodesy: Methods and Applications
Delva, P., Denker, H., & Lion, G. (2019) · Fundamental Theories of Physics · doi:10.1007/978-3-030-11500-5_2 · Cited by 28
Tanabe, T., Akamatsu, D., Kobayashi, T., Takamizawa, A., Yanagimachi, S., Ikegami, T., Suzuyama, T., Inaba, H., Okubo, S., Yasuda, M., et al. (2015) · Journal of the Physical Society of Japan · doi:10.7566/jpsj.84.115002 · Cited by 28
Rydberg electrometry for optical lattice clocks
Bowden, W., Hobson, R., Huillery, P. H., Gill, P., Jones, M. P. A., & Hill, I. R. (2017) · Physical Review A · doi:10.1103/physreva.96.023419 · Cited by 28
Super- and subradiance of clock atoms in multimode optical waveguides
Ostermann, L., Meignant, C., Genes, C., & Ritsch, H. (2019) · New Journal of Physics · doi:10.1088/1367-2630/ab05fb · Cited by 28
Reducing the Instability of an Optical Lattice Clock Using Multiple Atomic Ensembles
Zheng, X., Dolde, J., & Kolkowitz, S. (2024) · Physical Review X · doi:10.1103/physrevx.14.011006 · Cited by 27
Transportable optical atomic clocks for use in out-of-the-lab environments
Gellesch, M., Jones, J., Barron, R., Singh, A., Sun, Q., Bongs, K., & Singh, Y. (2020) · Advanced Optical Technologies · doi:10.1515/aot-2020-0023 · Cited by 26
Towards an exact relativistic theory of Earth's geoid undulation
Kopeikin, S. M., Михайловна, М. Е., & Karpik, A. P. (2015) · Physics Letters A · doi:10.1016/j.physleta.2015.02.046 · Cited by 25
Improved systematic evaluation of a strontium optical clock with uncertainty below 1 × 10 − 18
Jia, Z.-P., Li, J., Kong, D.-Q., Zhang, X., Yu, H.-W., Liu, X.-Y., Zhang, Y.-C., Wang, Y., Zhu, X.-Q., Zhang, J.-H., et al. (2026) · Metrologia · doi:10.1088/1681-7575/ae449e · Cited by 26
Lu, X., Guo, F., Wang, Y., Xu, Q., Zhou, C., Xia, J., Wu, W., & Chang, H. (2023) · Metrologia · doi:10.1088/1681-7575/acb05c · Cited by 24
Cold atom clocks and their applications in precision measurements*
Dai, S., Zheng, F., Liu, K., Chen, W., Lin, Y., Li, T., & Fang, F. (2020) · Chinese Physics B · doi:10.1088/1674-1056/abbbee · Cited by 24
Rapid evaluation of time scale using an optical clock
Ido, T., Hachisu, H., Nakagawa, F., & Hanado, Y. (2016) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/723/1/012041 · Cited by 23
International comparison of optical frequencies with transportable optical lattice clocksPreprint
Clock, I., Networking, O., Collaboration, :, Amy‐Klein, A., Benkler, E., Blondé, P., Bongs, K., Cantin, E., Chardonnet, C., et al. (2024) · arXiv · doi:10.48550/arxiv.2410.22973 · Cited by 23
Self-citationCancellation of collisional frequency shifts in optical lattice clocks with Rabi spectroscopy
Lee, S., Park, C. Y., Lee, W.-K., & Yu, D.-H. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/3/033030 · Cited by 22
Precision spectroscopy with a single 40 Ca + ion in a Paul trap
Guan, H., Huang, Y., Liu, P., Wu, B., Shao, H., & Gao, K. (2015) · Chinese Physics B · doi:10.1088/1674-1056/24/5/054213 · Cited by 22
Zero-Dead-Time Strontium Lattice Clock with a Stability at 10 − 19 Level
Liu, X.-Y., Liu, P., Li, J., Zhang, Y.-C., Wang, Y.-B., Jia, Z.-P., Zhang, X., Zhu, X.-Q., Kong, D.-Q., Song, W.-L., et al. (2025) · Physical Review Letters · doi:10.1103/zbpb-6qxb · Cited by 24
Huang, Y., Guan, H., Bian, W., Ma, L., Liang, K., Li, T., & Gao, K. (2017) · Applied Physics B · doi:10.1007/s00340-017-6731-x · Cited by 21
A Sub-ps Stability Time Transfer Method Based on Optical Modems
Frank, F., Stefani, F., Tuckey, P. A., & Pottie, P.-É. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2833389 · Cited by 21
Faraday-Shielded dc Stark-Shift-Free Optical Lattice Clock
Beloy, K., Zhang, X., McGrew, W. F., Hinkley, N., Yoon, T. H., Nicolodi, D., Fasano, R. J., Schäffer, S. A., Brown, R. C., & Ludlow, A. D. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.183201 · Cited by 20
Optical Atomic Clocks for Redefining SI Units of Time and Frequency
Sharma, L., Rathore, H. K., Utreja, S., Neelam, N., Roy, A., De, S., & Panja, S. (2020) · MAPAN · doi:10.1007/s12647-020-00397-y · Cited by 20
Dual-Mode Operation of an Optical Lattice Clock Using Strontium and Ytterbium Atoms
Akamatsu, D., Kobayashi, T., Hisai, Y., Tanabe, T., Hosaka, K., Yasuda, M., & Hong, F.-L. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2819888 · Cited by 19
Quantum treatment of two-stage sub-Doppler laser cooling of magnesium atoms
Prudnikov, O. N., Brazhnikov, D. V., Тайченачев, А. В., Yudin, V. I., Bonert, A. E., Ilenkov, R. Y., & Goncharov, A. (2015) · Physical Review A · doi:10.1103/physreva.92.063413 · Cited by 19
InGaN-diode-pumped AlGaInP VECSEL with sub-kHz linewidth at 689 nm
Moriya, P. H., Casula, R., Chappell, G. A., Parrotta, D. C., Ranta, S., Kahle, H., Guina, M. D., & Hastie, J. E. (2021) · Optics Express · doi:10.1364/oe.416210 · Cited by 19
Trapping, retention and laser cooling of Th3+ ions in a multisection linear quadrupole trap
Borisyuk, P. V., Vasil’ev, O. S., Derevyashkin, S. P., Kolachevsky, N., Lebedinskiǐ, Y. Y., Poteshin, S. S., Sysoev, A. A., Tkalya, E. V., Tregubov, D. O., Troyan, V. I., et al. (2017) · Quantum Electronics · doi:10.1070/qel16355 · Cited by 19
Post-Newtonian reference ellipsoid for relativistic geodesy
Kopeikin, S. M., Han, W.-B., & Михайловна, М. Е. (2016) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.93.044069 · Cited by 18
A New Record in Atomic Clock Performance
Nicholson, T., Bloom, B., Williams, J., Campbell, S., Bishof, M., Zhang, X., Zhang, W., Bromley, S., & Ye, J. (2013) · CU Scholar (University of Colorado Boulder) · Cited by 17
Metadata
- Authors
- Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., Vogt, S., Sterr, U., & Lisdat, C.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Corresponding author
- Grebing, Christian
- Hagemann, Christian
- Lisdat, Christian
- Venue
- New Journal of Physics
- Publisher
- IOP Publishing
- Published
- 2014-07-17
- Volume
- 16
- Issue
- 7
- Pages
- 073023
- ISSN
- 1367-2630 (ISSN-L)
- OpenAlex
- W1969928411
- Semantic Scholar
- d109d54b2516d8e6592a83228e183d05552a9a4b
- Cited by
- 182
- References
- 76
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 10 · 2023: 15 · 2022: 14 · 2021: 7 · 2020: 11 · 2019: 14 · 2018: 20 · 2017: 16 · 2016: 29 · 2015: 29 · 2014: 10
- FWCI
- 13.88
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- creativecommons.org/licenses/by/3.0/ (vor)
- Locations
- New Journal of Physics (publishedVersion, cc-by)
- arXiv (Cornell University) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- arXiv (Cornell University)
- Funders
- Pennsylvania State University
- European Association of National Metrology Institutes
- Deutsche Forschungsgemeinschaft (RTG 1729)
- Leibniz-Gemeinschaft
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- 87Sr, optical lattice clock, absolute frequency measurement, frequency standards, systematic uncertainties, SI second, frequency ratio measurement, optical clocks
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.