A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Open accessThe DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
We have measured the absolute frequency of the optical lattice clock based on 87 Sr at PTB with an uncertainty of using two caesium fountain clocks. This is close to the accuracy of todayʼs best realizations of the SI second. The absolute frequency of the 5 s 2 1 S 0 – 5s5p 3 P 0 transition in 87 Sr is .13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach , opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy or optical clock evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This international all-optical clock measurement surpasses the accuracy of the best possible comparison achievable by measurements against primary caesium clocks by one order of magnitude5212223.”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [21]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Several optical frequency ratio measurements as well as independent absolute frequency measurements of optical lattice clocks have been made locally at the following NMIs”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [166]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The accuracy of the former method is limited by the caesium microwave clocks with the most stringent bound set by our groups5212223 at an agreement within 4 × 10−16”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [21]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Today, several groups operate transportable optical clocks [16, 17, 25-31].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [31]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The details of the actual implementation of state preparation and interrogation being quite different in the two experimental realizations of a Sr lattice clock5212223, systematic and statistical uncertainties are highly independent and uncorrelated.”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [21]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
Standard, S. (2006) · Cited by 6,460
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · cited 4×
“In addition to their role as future primary standards, optical clocks are of interest as sensitive probes in areas such as relativistic geodesy [9], tests of relativity [10, 11], and searches for variations of fundamental constants [1, 12, 13, 14, 15].”
BackgroundInfluentialAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073 · cited 4×
“However, a recent study placed strontium lattice clocks into the accuracy regime of the best ion clocks [22].”
BackgroundInfluentialFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Self-citationA sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Self-citationUltrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572
Sr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554
Self-citationMaking optical atomic clocks more stable with 10−16-level laser stabilization
Jiang, Y. Y., Ludlow, A. D., Lemke, N. D., Fox, R. W., Sherman, J. A., Ma, L.-S., & Oates, C. W. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.313 · Cited by 462
Self-citationNIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355 · cited 1×
“The accuracy of today’s best Cs fountain clocks of 2− 4× 10 [32, 33, 34, 35, 36] sets a limit for the achievable accuracy of frequency measurements.”
BackgroundNew Limits on Coupling of Fundamental Constants to Gravity UsingSr87Optical Lattice Clocks
Blatt, S., Ludlow, A. D., Campbell, G. K., Thomsen, J. W., Zelevinsky, T., Boyd, M. M., Ye, J., Baillard, X., Fouché, M., Le Targat, R., et al. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.140801 · Cited by 333
Progress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Limit on the Present Temporal Variation of the Fine Structure Constant
Peik, E., Lipphardt, B., Schnatz, H., Schneider, T., Tamm, C., & Karshenboim, S. G. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.170801 · Cited by 282
Self-citationPorsev, S. G., & Derevianko, A. (2006) · Physical Review A · doi:10.1103/physreva.74.020502 · Cited by 279
Lemke, N., Ludlow, A., Barber, Z., Fortier, T., Diddams, S., Jiang, Y., Jefferts, S., Heavner, T., Parker, T., & Oates, C. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.063001 · Cited by 274
Self-citationExperimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250 · cited 7×
“While the frequency stability of optical lattice clocks is superior [18, 19], their systematic uncertainty had been limited to approximately 10 16 − [3, 7, 20, 21].”
BackgroundMethodResultInfluentialObservation of Photon-Assisted Tunneling in Optical Lattices
Sias, C., Lignier, H., Singh, Y. P., Zenesini, A., Ciampini, D., Morsch, O., & Arimondo, E. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.040404 · Cited by 242
High-Accuracy Optical Clock Based on the Octupole Transition inYb+171
Huntemann, N., Okhapkin, M., Lipphardt, B., Weyers, S., Tamm, C., & Peik, E. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.090801 · Cited by 241
Self-citationFortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Stock, M. (2013) · Metrologia · doi:10.1088/0026-1394/50/1/r1 · Cited by 217
Comparison of Two Independent Sr Optical Clocks with1×10−17Stability at103 s
Nicholson, T. L., Martin, M. J., Williams, J. R., Bloom, B. J., Bishof, M., Swallows, M. D., Campbell, S. L., & Ye, J. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.230801 · Cited by 205
Sr87Lattice Clock with Inaccuracy below10−15
Boyd, M. M., Ludlow, A. D., Blatt, S., Foreman, S. M., Ido, T., Zelevinsky, T., & Ye, J. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.083002 · Cited by 187
Optical lattice clocks with non-interacting bosons and fermions
Akatsuka, T., Takamoto, M., & Katori, H. (2008) · Nature Physics · doi:10.1038/nphys1108 · Cited by 170
Rabi spectroscopy and excitation inhomogeneity in a one-dimensional optical lattice clock
Blatt, S., Thomsen, J. W., Campbell, G. K., Ludlow, A. D., Swallows, M. D., Martin, M. J., Boyd, M. M., & Ye, J. (2009) · Physical Review A · doi:10.1103/physreva.80.052703 · Cited by 167
Bjerhammar, A. (1985) · Bulletin Géodésique · doi:10.1007/bf02520327 · Cited by 165 · cited 1×
“very good agreement with the measurement in Paris [7]. In addition to their role as future primary standards, optical clocks are of interest as sensitive probes in areas such as relativistic geodesy [9], tests of relativity [10, 11], and searches for variations of fundamental constants [1, 12, 13, 14, 15]. Two types o…”
ResultUncertainty evaluation of the atomic caesium fountain CSF1 of the PTB
Weyers, S., H bner, U., Schr der, R., Tamm, C., & Bauch, A. (2001) · Metrologia · doi:10.1088/0026-1394/38/4/7 · Cited by 160
Self-citationMadej, A. A., Dubé, P., Zhou, Z., Bernard, J. E., & Gertsvolf, M. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.203002 · Cited by 155
High Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.263004 · Cited by 154
Self-citationThe absolute frequency of the87Sr optical clock transition
Campbell, G. K., Ludlow, A. D., Blatt, S., Thomsen, J. W., Martin, M. J., de Miranda, M. H. G., Zelevinsky, T., Boyd, M. M., Ye, J., Diddams, S. A., et al. (2008) · Metrologia · doi:10.1088/0026-1394/45/5/008 · Cited by 151
Blackbody-radiation shift in the Sr optical atomic clock
Safronova, M. S., Porsev, S. G., Safronova, U. I., Kozlov, M. G., & Clark, C. W. (2013) · Physical Review A · doi:10.1103/physreva.87.012509 · Cited by 140
Li, R., Gibble, K., & Szymaniec, K. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/007 · Cited by 138
Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the10−17Level
Westergaard, P. G., Lodewyck, J., Lorini, L., Lecallier, A., Burt, E. A., Zawada, M., Millo, J., & Lemonde, P. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.210801 · Cited by 137
Cold Collision Frequency Shifts in a87RbAtomic Fountain
Sortais, Y., Bize, S., Nicolas, C., Clairon, A., Salomon, C., & Williams, C. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.3117 · Cited by 132
Recoil-Limited Laser Cooling ofSr87Atoms near the Fermi Temperature
Mukaiyama, T., Katori, H., Ido, T., Li, Y., & Kuwata-Gonokami, M. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.113002 · Cited by 131
High-Accuracy Measurement of Atomic Polarizability in an Optical Lattice Clock
Sherman, J. A., Lemke, N. D., Hinkley, N., Pizzocaro, M., Fox, R. W., Ludlow, A. D., & Oates, C. W. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.153002 · Cited by 131
Self-citationUncertainty evaluation of the caesium fountain clock PTB-CSF2
Gerginov, V, Nemitz, N., Weyers, S., Schröder, R., Griebsch, D., & Wynands, R. (2010) · Metrologia · doi:10.1088/0026-1394/47/1/008 · Cited by 129
Self-citationThe87Sr optical frequency standard at PTB
Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., et al. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/022 · Cited by 129 · cited 6×
“1× 10 Hz/s(2)) according to equation (5) in [21].”
BackgroundMethodInfluentialSelf-citationCalcium optical frequency standard with ultracold atoms: Approaching10−15relative uncertainty
Degenhardt, C., Stoehr, H., Lisdat, C., Wilpers, G., Schnatz, H., Lipphardt, B., Nazarova, T., Pottie, P.-E., Sterr, U., Helmcke, J., et al. (2005) · Physical Review A · doi:10.1103/physreva.72.062111 · Cited by 117
Self-citationOptical lattice clock with atoms confined in a shallow trap
Lemonde, P., & Wolf, P. (2005) · Physical Review A · doi:10.1103/physreva.72.033409 · Cited by 114 · cited 2×
“Another uncertainty contribution related to the optical lattice arises from atoms tunnelling from site to site [48], thus introducing a first-order Doppler shift.”
BackgroundMethodMeasuring the frequency of a Sr optical lattice clock using a 120 km coherent optical transfer
Hong, F.-L., Musha, M., Takamoto, M., Inaba, H., Yanagimachi, S., Takamizawa, A., Watabe, K., Ikegami, T., Imae, M., Fujii, Y., et al. (2009) · Optics Letters · doi:10.1364/ol.34.000692 · Cited by 113
Generalized Ramsey Excitation Scheme with Suppressed Light Shift
Huntemann, N., Lipphardt, B., Okhapkin, M., Tamm, C., Peik, E., Taichenachev, A. V., & Yudin, V. I. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.213002 · Cited by 112
Self-citationEinstein Gravity Explorer–a medium-class fundamental physics mission
Schiller, S., Tino, G. M., Gill, P., Salomon, C., Sterr, U., Peik, E., Nevsky, A., Görlitz, A., Svehla, D., Ferrari, G., et al. (2009) · Experimental Astronomy · doi:10.1007/s10686-008-9126-5 · Cited by 110
Self-citationAccuracy evaluation of an optical lattice clock with bosonic atoms
Baillard, X., Fouché, M., Le Targat, R., Westergaard, P. G., Lecallier, A., Le Coq, Y., Rovera, G. D., Bize, S., & Lemonde, P. (2007) · Optics Letters · doi:10.1364/ol.32.001812 · Cited by 100
An optical lattice clock with spin-polarized 87Sr atoms
Baillard, X., Fouché, M., Le Targat, R., Westergaard, P. G., Lecallier, A., Chapelet, F., Abgrall, M., Rovera, G. D., Laurent, P., Rosenbusch, P., et al. (2008) · The European Physical Journal D · doi:10.1140/epjd/e2007-00330-3 · Cited by 96
Self-citationNeutral Atom Frequency Reference in the Deep Ultraviolet withFractional Uncertainty=5.7×10−15
McFerran, J. J., Yi, L., Mejri, S., Di Manno, S., Zhang, W., Guéna, J., Le Coq, Y., & Bize, S. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.183004 · Cited by 89
Collisional Losses, Decoherence, and Frequency Shifts in Optical Lattice Clocks with Bosons
Lisdat, C., Winfred, J. S. R. V., Middelmann, T., Riehle, F., & Sterr, U. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.090801 · Cited by 87
Self-citationMeasurement of a Superconducting Energy Gap in a Homogeneously Amorphous Insulator
Sherman, D. F., Kopnov, G., Shahar, D., & Frydman, A. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.177006 · Cited by 87
Weyers, S., Lipphardt, B., & Schnatz, H. (2009) · Physical Review A · doi:10.1103/physreva.79.031803 · Cited by 86
Self-citationDistributed cavity phase frequency shifts of the caesium fountain PTB-CSF2
Weyers, S., Gerginov, V, Nemitz, N., Li, R., & Gibble, K. (2012) · Metrologia · doi:10.1088/0026-1394/49/1/012 · Cited by 80
Self-citationMatsubara, K., Hachisu, H., Li, Y., Nagano, S., Locke, C., Nogami, A., Kajita, M., Hayasaka, K., Ido, T., & Hosokawa, M. (2012) · Optics Express · doi:10.1364/oe.20.022034 · Cited by 79
Scattering of Cold-Atom Coherences by Hot Atoms: Frequency Shifts from Background-Gas Collisions
Gibble, K. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.180802 · Cited by 72
Cs-based optical frequency measurement using cross-linked optical and microwave oscillators
Tamm, C., Huntemann, N., Lipphardt, B., Gerginov, V., Nemitz, N., Kazda, M., Weyers, S., & Peik, E. (2014) · Physical Review A · doi:10.1103/physreva.89.023820 · Cited by 72 · cited 2×
“CSF2 we utilized the Yb clock laser to transfer its stability to the microwave regime with the help of a fs-laser frequency comb [59, 60, 8].”
BackgroundMethodSelf-citationObservation and cancellation of a perturbing dc stark shift in strontium optical lattice clocks
Lodewyck, J., Zawada, M., Lorini, L., Gurov, M., & Lemonde, P. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2209 · Cited by 72
Determination of the5d6s3D1state lifetime and blackbody-radiation clock shift in Yb
Beloy, K., Sherman, J. A., Lemke, N. D., Hinkley, N., Oates, C. W., & Ludlow, A. D. (2012) · Physical Review A · doi:10.1103/physreva.86.051404 · Cited by 69
Self-citationTackling the Blackbody Shift in a Strontium Optical Lattice Clock
Middelmann, T., Lisdat, C., Falke, S., Winfred, J. S. R. V., Riehle, F., & Sterr, U. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2088470 · Cited by 62
Self-citationDelivering pulsed and phase stable light to atoms of an optical clock
Falke, S., Misera, M., Sterr, U., & Lisdat, C. (2012) · Applied Physics B · doi:10.1007/s00340-012-4952-6 · Cited by 57 · cited 2×
“The optical path lengths to frequency comb and optical lattice are actively stabilized utilizing AOMs [41].”
MethodSelf-citationThe total deviation approach to long-term characterization of frequency stability
Howe, D. A. (2000) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.869040 · Cited by 57
Taichenachev, A. V., Yudin, V. I., Ovsiannikov, V. D., Pal’chikov, V. G., & Oates, C. W. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.193601 · Cited by 56
Lipphardt, B., Grosche, G., Sterr, U., Tamm, C., Weyers, S., & Schnatz, H. (2009) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2008.2007051 · Cited by 54
Self-citationProviding $10^{-16}$ Short-Term Stability of a 1.5-$\mu\hbox{m}$ Laser to Optical Clocks
Hagemann, C., Grebing, C., Kessler, T., Falke, S., Lemke, N., Lisdat, C., Schnatz, H., Riehle, F., & Sterr, U. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2242597 · Cited by 52
Self-citationYtterbium in Quantum Gases and Atomic Clocks: van der Waals Interactions and Blackbody Shifts
Safronova, M. S., Porsev, S. G., & Clark, C. W. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.230802 · Cited by 51
Yamaguchi, A., Shiga, N., Nagano, S., Li, Y., Ishijima, H., Hachisu, H., Kumagai, M., & Ido, T. (2012) · Applied Physics Express · doi:10.1143/apex.5.022701 · Cited by 51
Effects of surface condition on the infrared absorptivity of 304 stainless steel
Wieting, T. J., & DeRosa, J. L. (1979) · Journal of Applied Physics · doi:10.1063/1.326083 · Cited by 50
Akamatsu, D., Inaba, H., Hosaka, K., Yasuda, M., Onae, A., Suzuyama, T., Amemiya, M., & Hong, F.-L. (2014) · Applied Physics Express · doi:10.7567/apex.7.012401 · Cited by 49
THE ATOMIC CAESIUM FOUNTAIN CSF1 OF PTB
Weyers, S., Bauch, A., Schröder, R., & Tamm, C. (2002) · Symposium on Frequency Standards and Metrology · doi:10.1142/9789812777713_0009 · Cited by 31
Self-citationDispersion and polarization interactions of the strontium atom
Mitroy, J., & Zhang, J. Y. (2010) · Molecular Physics · doi:10.1080/00268976.2010.501766 · Cited by 28
Long-range transport of ultracold atoms in a far-detuned one-dimensional optical lattice
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012) · New Journal of Physics · doi:10.1088/1367-2630/14/7/073020 · Cited by 28
Self-citationFundamental constants and units and the search for temporal variations
Peik, E. (2010) · Nuclear Physics B - Proceedings Supplements · doi:10.1016/j.nuclphysbps.2010.08.003 · Cited by 19
Porsev, S. G., & Derevianko, A. (2012) · Physical Review A · doi:10.1103/physreva.86.029904 · Cited by 19
Lattice Induced Frequency Shifts in Sr Optical Lattice Clocks at the $10^{-17}$ Level
Westergaard, P. G., Lodewyck, J., Lorini, L., Lecallier, A., Burt, E. A., Zawada, M., Millo, J., & Lemonde, P. (2011) · HAL · Cited by 16
Critically evaluated theoretical atomic properties of Y iii
Safronova, M. S., & Safronova, M. S. (2013) · Physical Review A · doi:10.1103/physreva.87.032501 · Cited by 10
Tackling the black body shift in a strontium optical lattice clock
Lisdat, C., Middelmann, T., Falke, S., Winfred, J. S. R. V., Riehle, F., & Sterr, U. (2010) · Conference on Precision Electromagnetic Measurements · doi:10.1109/cpem.2010.5544378 · Cited by 9
Self-citationYtterbium in quantum gases and atomic clocks: van der Waals interactions and blackbody shifts
Porsev, S. G., Safronova, M. S., & Clark, C. S. (2013) · Bulletin of the American Physical Society · Cited by 1
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Ultralow-noise mode-locked fiber lasers and frequency combs: principles, status, and applications
Kim, J., & Song, Y. (2016) · Advances in Optics and Photonics · doi:10.1364/aop.8.000465 · Cited by 567
Metadata
- Authors
- Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., Vogt, S., Sterr, U., & Lisdat, C.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Corresponding author
- Grebing, Christian
- Hagemann, Christian
- Lisdat, Christian
- Venue
- New Journal of Physics
- Publisher
- IOP Publishing
- Published
- 2014-07-17
- Volume
- 16
- Issue
- 7
- Pages
- 073023
- ISSN
- 1367-2630 (ISSN-L)
- OpenAlex
- W1969928411
- Semantic Scholar
- d109d54b2516d8e6592a83228e183d05552a9a4b
- Cited by
- 182
- References
- 76
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 10 · 2023: 15 · 2022: 14 · 2021: 7 · 2020: 11 · 2019: 14 · 2018: 20 · 2017: 16 · 2016: 29 · 2015: 29 · 2014: 10
- FWCI
- 13.88
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- creativecommons.org/licenses/by/3.0/ (vor)
- Locations
- New Journal of Physics (publishedVersion, cc-by)
- arXiv (Cornell University) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- arXiv (Cornell University)
- Funders
- Pennsylvania State University
- European Association of National Metrology Institutes
- Deutsche Forschungsgemeinschaft (RTG 1729)
- Leibniz-Gemeinschaft
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- 87Sr, optical lattice clock, absolute frequency measurement, frequency standards, systematic uncertainties, SI second, frequency ratio measurement, optical clocks
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.