ERP-XTTN: interpretable prototype-guided cross-attention for cross-subject ERP classification
Open accessThe DOI matches its Crossref record; 37 of the 39 references it cites were found in a registry or an index; 25 of the 49 sources its claims cite were checked for support.
Abstract
OBJECTIVE: Interpretable brain-computer interface classifiers that generalize across subjects without calibration remain an open challenge. We evaluated whether prototype-based cross-attention can provide competitive, inherently interpretable event-related potential (ERP) classification across diverse paradigms under deployment-compatible conditions. APPROACH: We propose ERP-XTTN (ERP Cross-Attention), a cross-attention architecture that routes input electroencephalographic peaks to fixed difference-wave prototypes via query-key-only cross-attention with no value projection. Classification is based directly on prototype similarity and a separate measure of component amplitude, so that the prototype content contributes to every decision by construction. Prototypes are derived automatically from prominent extrema in the training-fold grand-average difference wave. We evaluated across three public sources (BNCI Horizon 2020, HRI Cursor, and ERP CORE) encompassing eight ERP components (ERN, LRP, ErrP, N170, P300, N2pc, MMN, N400). Evaluations used leave-one-subject-out (LOSO) cross-validation with causal filtering at a three-channel montage, compared against EEGNet, EEG-Deformer, ERP Prototypical Matching Net (EPMN), and xDAWN with Riemannian geometry (xDAWN+RG). MAIN RESULTS: At three channels, the mean performance gap between the best baseline and ERP-XTTN was 0.025 area under the receiver operating characteristic curve (AUROC). Prototype interventions confirmed that decisions depend on the physiological content of the prototypes rather than on the routing attention pattern alone. False positives morphologically resembled true positives more than true negatives did across all datasets, indicating classification errors are neurophysiologically explicable. SIGNIFICANCE: ERP-XTTN generalizes across diverse ERP morphologies under causal, calibration-free conditions, while retaining competitive performance and decisions that depend directly on physiological prototype content at a three-channel montage. Unlike post-hoc explanation methods for black-box models, the basis of each decision is directly observable in the trained model itself. To our knowledge, this is the first epoch-level LOSO benchmark on ERP CORE.
Overview
CoChat Summary
TL;DR
ERP-XTTN is a prototype-guided cross-attention classifier for cross-subject ERP decoding that routes detected EEG peaks to fixed difference-wave prototypes via query-key-only attention, making prototype content necessary to each decision. Across nine datasets and eight ERP components under causal, calibration-free LOSO evaluation at three channels, it was competitive with EEGNet, EEG-Deformer, EPMN, and xDAWN+RG, with a mean gap of 0.025 AUROC from the best baseline.
Key findings
- At the three-channel montage, ERP-XTTN achieved a mean AUROC of 0.709 across nine datasets, versus 0.732 for EEGNet, 0.724 for EEG-Deformer, 0.716 for xDAWN+RG, and 0.697 for EPMN; the descriptive gap from the best baseline averaged 0.025 AUROC (range 0.006–0.059).
- Prototype interventions showed decisions depended on physiological prototype content: polarity inversion drove routing below the noise null on all nine datasets (e.g., HRI 0.81 → 0.19 against a null near 0.50), while an unconstrained learned readout over the same attention tensor was unchanged by inversion (HRI 0.82 → 0.82).
- False positives morphologically resembled true positives more than true negatives did across all datasets: TP↔FP correlations were r = 0.60–0.86, TP↔TN was generally lower, and the ordering TP↔FP > TP↔TN held across all five seeds; MMN was an exception with TP↔TN r = −0.31.
- The paper reports the first epoch-level LOSO benchmark on ERP CORE under deployment-compatible causal preprocessing, to the authors’ knowledge.
Methods
- ERP-XTTN tokenizes each trial into detected peaks, embeds them, applies self-attention, then performs query-key-only cross-attention against prototypes derived automatically from the training-fold grand-average difference wave (up to K = 4). A routing factor based on whitened cosine similarity is combined with an amplitude factor from monopolar and bipolar matched filtering via L2-penalized logistic regression fit only on training subjects.
- Nine datasets from BNCI Horizon 2020, HRI Cursor, and ERP CORE covered eight ERP components (ERN, LRP, ErrP, N170, P300, N2pc, MMN, N400). All data were causally filtered (4th-order Butterworth, 1–10 Hz), epoched 0–800 ms, and evaluated at a targeted three-channel montage under LOSO cross-validation.
- Neural models were trained with AdamW, class-weighted BCE, temporal jitter, and Gaussian noise; AUROC was the primary metric, with balanced accuracy at a fixed 0.5 threshold. Comparisons used Wilcoxon signed-rank tests with Hodges-Lehmann estimates and Benjamini-Hochberg FDR correction across 36 tests.
Limitations
- Stated: routing patterns are not identifiable across independent retrainings; evaluations were offline; prototypes were frozen and may not capture individual variation; ERP CORE has 40 subjects, moderate for LOSO and insufficient for clinical or underrepresented populations; the LRP window captures post-response rather than canonical pre-response activity; hyperparameters were shared across neural models without per-model optimization; balanced accuracy lagged AUROC due to the fixed uncalibrated 0.5 threshold.
- Stated: at the full montage, amplitude-localization controls became uninformative, weakening the groundedness claim for the full model, and the amplitude feature space grows quadratically with channel count.
- Evident from the text: EPMN was reimplemented from the original description rather than using an official implementation, and no hyperparameter optimization was performed for any model.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
22 Valid · 3 Not valid · 13 Not checked · 170 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“and standard calibration pipelines fail to produce a functional classifier for a non-negligible portion of users [5].”
What the sources say
- Supportedcites [5] Vidaurre, 2010, Towards a cure for BCI illiteracy, Brain Topogr. source
The Introduction estimates that BCI control does not work for 15–30% of users. In its 80-participant screening study, some users had no classifier with acceptable accuracy, while others had a trained classifier that did not work well during feedback. The Conclusion also says offline calibration can yield a classifier that is non-functional during feedback. Page numbers are not supplied in our copy. (LLM, conf=0.92)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“To our knowledge, this is the first epoch-level LOSO benchmark on ERP CORE.”
- Also stated in: § 1 Introduction · p. 2 · hedged
“To our knowledge, this is the first epoch-level LOSO benchmark on ERP CORE under deployment-compatible constraints.”
What the sources say
- Partly supportedcites [28] Aristimunha, 2023, Evaluating the structure of cognitive tasks with transfer learning sourceExperimental — accuracy not yet measured
Our copy shows Aristimunha et al. (2023) do run epoch-level decoding on ERP CORE (Sec. 4.3 'EEG pre-processing and epoching': trials cropped into 1000 ms windows; Sec. 5.1 and Fig. 4: cross-subject balanced accuracy across the seven ERP CORE paradigms), so the source is indeed an epoch-level cross-subject benchmark on ERP CORE. But it does not use leave-one-subject-out: Sec. 4.4 'Data splitting' states a 56/24/20 subject-level split repeated under a 5-fold cross-validation scheme, not LOSO. Nor does the source make any primacy statement — 'the first such benchmark' is the citing authors' own conclusion, which our copy neither states nor contradicts. (LLM, conf=0.68)
- Could not verifycites [29] Qin, 2026, Evaluating spatial normalization for SVM-based EEG decoding: a within- and between-subjects perspective, Biomed. Signal Process. Control sourceExperimental — accuracy not yet measured
The cited sentence is a priority claim about the citing paper itself ('this is the first…'), and our copy of Qin et al. (2026) contains no statement about the publication history of epoch-level leave-one-subject-out benchmarks on ERP CORE. The closest thing in it is methodological: Section 2.3 (p. 6) and Fig. 2 (p. 5) describe a between-subjects leave-one-subject-out SVM evaluation on the seven binary ERP CORE paradigms, but its samples are formed by averaging F = 10 single-trial epochs into one ERP sample (p. 6), so the paper does not characterise itself as an 'epoch-level' LOSO benchmark, and the Introduction's contribution list (p. 3) is framed around spatial normalization, not around being first. Searched: 'leave-one-subject-out cross-validation between-subjects decoding', 'epoch-level decoding single-trial ERP epochs averaged', 'to our knowledge the first study / novel benchmark', 'single-trial epoch-level versus trial-averaged samples'. Nothing in our copy confirms the priority assertion, and nothing flatly contradicts it given the 'epoch-level' qualifier, so the claim cannot be settled from this source. (LLM, conf=0.66)
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: unclear — It is unclear why the paper says it holds.
- Also stated in: § 1 Introduction · p. 2 · hedged
Every source the paper cites for this claim was checked and supports it.
In the paper
“Note that the original ERP CORE publication [33] reports smaller per-component samples (N = 34-39) after exclusions based on behavioral-accuracy and artifact-rejection criteria tied to their ERP-averaging pipeline.”
What the sources say
- Supportedcites [33] Kappenman, 2021, ERP CORE: an open resource for human event-related potential research, NeuroImage source
The Materials and Methods—Participants section (page unavailable) reports 40 participants and exclusions of 1–6 participants per component, yielding samples of 34–39. It specifies task-level accuracy and artifact criteria, including an ERN criterion applied after artifact rejection; the Signal Processing and Averaging section describes the associated trial exclusions. (LLM, conf=0.94)
plainstates a causen = 34- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“ERP-XTTN (ERP Cross-Attention) [30] was introduced for error-related potentials, using a constrained, hand-specified polarity sequence to locate prototype windows based on the training subjects' grand-average difference wave.”
What the sources say
- Supportedcites [30] Wyman, 2026, ERP-XTTN: interpretable cross-subject error-related potential classification via cross-attention to data-driven ERP prototypes source
METHODS (p. 2) states that prototypes are derived from the grand-average training-set difference wave (mean error minus mean correct, recomputed per LOSO fold) and that peaks on the smoothed Cz difference wave are detected 'subject to a P-N-P-N polarity constraint reflecting the canonical ErrP morphology' (P1, Ne, Pe, LateN), with each peak expanded to a window bounded by smoothed zero-crossings and clamped to 40-200 ms — i.e. a fixed, author-specified polarity sequence locating the prototype windows. Figure 1 (METHODS, p. 2) and Figure 2 (p. 3) corroborate the K=4 P-N-P-N peak detection on the training set's grand-average difference wave, and the abstract (p. 1) confirms the architecture was proposed for ErrP classification. (LLM, conf=0.90)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Practical deployment often limits channel count, as many commercial and mobile devices lack research-grade electrode coverage [3].”
What the sources say
- Supportedcites [3] Sabio, 2024, A scoping review on the use of consumer-grade EEG devices for research, PLoS One source
The Method and results section states that research-grade EEG devices typically have dozens of scalp electrodes, whereas consumer-grade devices have fewer. Table 3 lists commercial devices with 1–16 channels, supporting the claimed difference in electrode coverage. (LLM, conf=0.93)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
67 more claims
Create a free account to see all 208 claims and to verify the 7 references still open.
- Probably not a substantial claim. 55
- It may state two separate claims as one. 89
- The quote only partly states this claim. 27
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ 1 Introduction · p. 2
“We additionally generalize ERP-XTTN to eight ERP components via automatic peak detection, requiring no component-specific architecture, preprocessing, or training choices.”
§ 2.2 Preprocessing · p. 3
“All datasets were evaluated using a 3-channel set tailored to the ERP of interest (Table 1)”
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“Event-related potentials (ERPs) are time-locked neural responses measurable via electroencephalography (EEG) that index sensory, attentional, and cognitive processing [1] and underlie a range of brain-computer interface (BCI) applications such as error detection and spelling systems [2].”
EEGNet: a compact convolutional neural network for EEG-based brain-computer interfaces
Lawhern, V. J., Solon, A. J., Waytowich, N. R., Gordon, S. M., Hung, C. P., & Lance, B. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aace8c · Cited by 5,115 · cited 6×
“General-purpose deep learning architectures such as EEGNet [6–8] have been evaluated across multiple BCI paradigms; CNN-transformer architectures have demonstrated competitive cross-subject ErrP performance under leave-one-subject-out (LOSO) evaluation [ 9, 10]; and dense convolutional transformers…”
InfluentialA review of classification algorithms for EEG-based brain–computer interfaces: A 10 year update
Lotte, F., Bougrain, L., Cichocki, A., Clerc, M., Congedo, M., Rakotomamonjy, A., & Yger, F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab2f2 · Cited by 2,239 · cited 2×
“General-purpose deep learning architectures such as EEGNet [6–8] have been evaluated across multiple BCI paradigms; CNN-transformer architectures have demonstrated competitive cross-subject ErrP performance under leave-one-subject-out (LOSO) evaluation [ 9, 10]; and dense convolutional transformers…”
Jain, S., & Wallace, B. (2019) · Conference of the North American Chapter of the Association for Computational Linguistics: Human Language Technologies (NAACL-HLT) · doi:10.18653/v1/n19-1357 · Cited by 1,987 · cited 1×
“Peak detection is performed inside the forward pass, on the augmented signal, rather than as a pre-processing step; tokenization is therefore part of the model and is subject to the same augmentation as the rest of the input (section 2.5).”
InfluentialSingle-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138 · cited 1×
“Classical pipelines such as shrinkage linear discriminant analysis (LDA) [12] achieve strong cross-subject ERP classification and can reveal discriminative spatial patterns, but their interpretability rests on a fixed decision rule rather than trial-specific evidence for each classification. xDAWN…”
Attention is not not Explanation
Wiegreffe, S., & Pinter, Y. (2019) · Proceedings of the 2019 Conference on Empirical Methods in Natural Language Processing and the 9th International Joint Conference on Natural Language Processing (EMNLP-IJCNLP) · doi:10.18653/v1/d19-1002 · Cited by 966 · cited 1×
“Peak detection is performed inside the forward pass, on the augmented signal, rather than as a pre-processing step; tokenization is therefore part of the model and is subject to the same augmentation as the rest of the input (section 2.5).”
InfluentialxDAWN Algorithm to Enhance Evoked Potentials: Application to Brain–Computer Interface
Rivet, B., Souloumiac, A., Attina, V., & Gibert, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2012869 · Cited by 537 · cited 2×
“…patterns, but their interpretability rests on a fixed decision rule rather than trial-specific evidence for each classification. xDAWN spatial filtering [13] with Riemannian geometry (xDAWN + RG) features also perform well cross-subject [14, 15] but lack obvious physiological interpretation [8].”
Towards a cure for BCI illiteracy
Vidaurre, C., & Blankertz, B. (2010) · Brain Topography · doi:10.1007/s10548-009-0121-6 · Cited by 501 · cited 1×
“Classification must generalize across subjects, since per-subject calibration delays setup and limits scalability [4], and standard calibration pipelines fail to produce a functional classifier for a non-negligible portion of users [5].”
Transfer Learning for EEG-Based Brain–Computer Interfaces: A Review of Progress Made Since 2016
Wu, D., Xu, Y., & Lu, B.-L. (2022) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2020.3007453 · Cited by 434
Lotte, F. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2404941 · Cited by 327 · cited 1×
“Classification must generalize across subjects, since per-subject calibration delays setup and limits scalability [4], and standard calibration pipelines fail to produce a functional classifier for a non-negligible portion of users [5].”
Learning From EEG Error-Related Potentials in Noninvasive Brain-Computer Interfaces
Chavarriaga, R., & Millan, J. D. R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2053387 · Cited by 277 · cited 1×
“They are drawn from three public sources: the BNCI Horizon 2020 dataset (BNCI) [31], the HRI Cursor ErrP dataset (HRI) [32], and ERP CORE [33].”
ERP CORE: An open resource for human event-related potential research
Kappenman, E. S., Farrens, J. L., Zhang, W., Stewart, A. X., & Luck, S. J. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2020.117465 · Cited by 223
ERP CORE: An Open Resource for Human Event-Related Potential ResearchPreprint
Kappenman, E., Farrens, J. L., Zhang, W., et al. (2020) · NeuroImage · doi:10.31234/osf.io/4azqm · Cited by 212 · cited 3×
“…channel is the single electrode on which prototype time windows are located by peak detection (section 2.3.2); for the ERP CORE datasets it is the canonical site reported for that component by Kappenman et al [33], and for BNCI and HRI it is Cz, the central midline site available in both montages.”
InfluentialEEG-Deformer: A Dense Convolutional Transformer for Brain-Computer Interfaces
Ding, Y., Li, Y., Sun, H., Liu, R., Tong, C., Liu, C., Zhou, X., & Guan, C. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3504604 · Cited by 120
Online and Offline Domain Adaptation for Reducing BCI Calibration Effort
Wu, D. (2017) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2016.2608931 · Cited by 114 · cited 1×
“Domain adaptation and domain generalization methods address cross-subject distribution shift in ERP-based BCIs [20–22], but are not designed for interpretability.”
Discriminative Canonical Pattern Matching for Single-Trial Classification of ERP Components
Xiao, X., Xu, M., Jin, J., Wang, Y., Jung, T.-P., & Ming, D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2958641 · Cited by 113 · cited 1×
“Discriminative canonical pattern matching with time-domain ERP templates has been demonstrated across multiple ERP paradigms but only within-subject [27].”
A Plug&Play P300 BCI Using Information Geometry
Barachant, A., & Congedo, M. (2014) · arXiv · doi:10.48550/arxiv.1409.0107 · Cited by 102 · cited 1×
“…patterns, but their interpretability rests on a fixed decision rule rather than trial-specific evidence for each classification. xDAWN spatial filtering [13] with Riemannian geometry (xDAWN + RG) features also perform well cross-subject [14, 15] but lack obvious physiological interpretation [8].”
A scoping review on the use of consumer-grade EEG devices for research
Sabio, J., Williams, N. S., McArthur, G. M., & Badcock, N. A. (2024) · PLOS ONE · doi:10.1371/journal.pone.0291186 · Cited by 98 · cited 1×
“Practical deployment often limits channel count, as many commercial and mobile devices lack research-grade electrode coverage [3].”
The Necessity of Leave One Subject Out (LOSO) Cross Validation for EEG Disease Diagnosis
Kunjan, S., Grummett, T. S., Pope, K. J., Powers, D. M. W., Fitzgibbon, S. P., Bastiampillai, T., Battersby, M., & Lewis, T. W. (2021) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-86993-9_50 · Cited by 80 · cited 1×
“All models were evaluated using LOSO cross-validation [36]: each subject served as the test set exactly once, with all remaining subjects forming the training set.”
Li, F., Xia, Y., Wang, F., Zhang, D., Li, X., & He, F. (2020) · Applied Sciences · doi:10.3390/app10051804 · Cited by 64 · cited 1×
“…patterns, but their interpretability rests on a fixed decision rule rather than trial-specific evidence for each classification. xDAWN spatial filtering [13] with Riemannian geometry (xDAWN + RG) features also perform well cross-subject [14, 15] but lack obvious physiological interpretation [8].”
A Feasibility Study for Validating Robot Actions Using EEG-Based Error-Related Potentials
Ehrlich, S. K., & Cheng, G. (2019) · International Journal of Social Robotics · doi:10.1007/s12369-018-0501-8 · Cited by 58 · cited 1×
“They are drawn from three public sources: the BNCI Horizon 2020 dataset (BNCI) [31], the HRI Cursor ErrP dataset (HRI) [32], and ERP CORE [33].”
A Generic Transferable EEG Decoder for Online Detection of Error Potential in Target Selection
Bhattacharyya, S., Konar, A., Tibarewala, D. N., & Hayashibe, M. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00226 · Cited by 43 · cited 1×
“Calibration-free cross-subject ErrP classification has been demonstrated with generalized LDA [16], an xDAWN + RG pipeline with a support vector machine classifier [17], ensemble classifiers [18], and online PCA-based pipelines [19], though without inherent inter-pretability.”
alexandrebarachant/pyRiemann: Minor release with bugfix and dependencies update
Barachant, A., Barthélemy, Q., Berg, G. W. V., Gramfort, A., Chevallier, S., Jean-Rémi, K. I. N. G., Rodrigues, P. L. C., Junqueira Lopes, B., maxdolle, gcattan, et al. (2015) · HAL · doi:10.5281/zenodo.593816 · Cited by 41
Lopes-Dias, C., Sburlea, A. I., Breitegger, K., Wyss, D., Drescher, H., Wildburger, R., & Müller-Putz, G. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abd1eb · Cited by 39 · cited 1×
“Calibration-free cross-subject ErrP classification has been demonstrated with generalized LDA [16], an xDAWN + RG pipeline with a support vector machine classifier [17], ensemble classifiers [18], and online PCA-based pipelines [19], though without inherent inter-pretability.”
Wei, W., Qiu, S., Zhang, Y., Mao, J., & He, H. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5eb7 · Cited by 24
Classification of error-related potentials evoked during stroke rehabilitation training
Kumar, A., Pirogova, E., Mahmoud, S. S., & Fang, Q. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1d32 · Cited by 17 · cited 1×
“Calibration-free cross-subject ErrP classification has been demonstrated with generalized LDA [16], an xDAWN + RG pipeline with a support vector machine classifier [17], ensemble classifiers [18], and online PCA-based pipelines [19], though without inherent inter-pretability.”
Schönleitner, F. M., Otter, L., Ehrlich, S. K., & Cheng, G. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2020.3012436 · Cited by 12 · cited 3×
“All results reported here use causal IIR filtering under calibration-free LOSO evaluation; many published LOSO benchmarks use acausal filtering instead [9, 16], so their reported performance is not reproducible in a forward-processing pipeline.”
InfluentialA framework for Interpretable deep learning in cross-subject detection of event-related potentials
Jalilpour, S., & Müller-Putz, G. (2024) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2024.109642 · Cited by 12 · cited 1×
“Post-hoc importance estimation has also been used to guide channel and time-window selection for ErrP decoding, with the estimates validated against error-processing neurophysiology [24].”
Evaluating the structure of cognitive tasks with transfer learning
Aristimunha, B., de Camargo, R. Y., Pinaya, W. H. L., Chevallier, S., Gramfort, A., & Rommel, C. (2023) · arXiv · doi:10.48550/arxiv.2308.02408 · Cited by 4 · cited 2×
“…and transformer architectures, metric-based prototype learning, and classical spatial filtering, and its agreement with prior cross-subject results on ERP CORE [28], suggests that the ordering primarily reflects ERP signal and paradigm properties rather than classifier-specific behavior.”
Ren, G., Kumar, A., Mahmoud, S. S., & Fang, Q. (2024) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2024.1394107 · Cited by 4 · cited 2×
“On BNCI, Ren et al [10] reported a best per-session LOSO AUROC of 0.755 with two channels (FCz, Cz); ERP-XTTN achieved 0.771 with three channels under causal filtering.”
InfluentialZhang, B., Xu, M., Zhang, Y., Ye, S., & Chen, Y. (2024) · Bioengineering · doi:10.3390/bioengineering11040347 · Cited by 4 · cited 1×
“Prototype-based approaches, including ERP pro-totypical matching net (EPMN) [25] and Attention-ProNet [26], achieve zero-calibration cross-subject decoding in P300-based rapid serial visual presentation tasks by matching trials to class prototypes in a learned embedding space.”
Qin, Y., Xu, Q., Kujala, T., Wang, X., & Cong, F. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.109535 · Cited by 1 · cited 1×
“Cross-subject evaluation on ERP CORE has been reported using fold-based splits [28] and time-point-wise LOSO decoding [ 29], but neither provides an epoch-level LOSO classification benchmark under deployment-compatible constraints such as causal filtering.”
Informing EEG-Based Error Decoding With Explainable AI
Jeremy Chan, H. T., Wimmer, M., Šimić, I., Müller-Putz, G. R., & Veas, E. (2025) · 2025 IEEE International Conference on Systems, Man, and Cybernetics (SMC) · doi:10.1109/smc58881.2025.11343575 · cited 1×
“These methods can identify features associated with a trained model’s predictions and map them to known neurophysiological phenomena, in some cases at the single-trial level, but because they are approximations computed after training, their faithfulness to the decision process is not guaranteed;…”
Ren, G., Mahmoud, S. S., Kumar, A., Fang, Q., & Yu, B. (2023) · 2023 IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10389146 · cited 2×
“All results reported here use causal IIR filtering under calibration-free LOSO evaluation; many published LOSO benchmarks use acausal filtering instead [9, 16], so their reported performance is not reproducible in a forward-processing pipeline.”
Luo, T.-J. (2026) · Cognitive Neurodynamics · doi:10.1007/s11571-026-10450-2 · cited 1×
“Domain adaptation and domain generalization methods address cross-subject distribution shift in ERP-based BCIs [20–22], but are not designed for interpretability.”
Wyman, C. G., & Hirshfield, L. (2026) · Verlag der Technischen Universität Graz · doi:10.3217/978-3-99161-093-9-053
Self-citationERP-XTTN: Interpretable Cross-Attention ERP Classifier
Wyman, C. G. (2026) · Zenodo · doi:10.5281/zenodo.21810709
Metadata
- Authors
- Genevier Wyman, C., & Hirshfield, L.
- Affiliations
- University of Colorado Boulder
- University of Colorado Boulder (US)
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2026-09-08
- Volume
- 23
- Issue
- 5
- Pages
- 056010
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W7163402782
- Cited by
- 0
- References
- 39
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- publishingsupport.iopscience.iop.org/questions/alternative-author-rights-policies/ (vor)
- Locations
- Journal of Neural Engineering (publishedVersion, cc-by)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University) (cc-by)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Keywords
- cross-attention, prototype-based classification, cross-subject generalization, ERP components, leave-one-subject-out cross-validation, causal filtering
- MeSH terms
- Attention, Electroencephalography, Evoked Potentials, Humans, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.