Intra-day signal instabilities affect decoding performance in an intracortical neural interface system
Open accessThe DOI matches its Crossref record; 66 of the 67 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Motor neural interface systems (NIS) aim to convert neural signals into motor prosthetic or assistive device control, allowing people with paralysis to regain movement or control over their immediate environment. Effector or prosthetic control can degrade if the relationship between recorded neural signals and intended motor behavior changes. Therefore, characterizing both biological and technological sources of signal variability is important for a reliable NIS. APPROACH: To address the frequency and causes of neural signal variability in a spike-based NIS, we analyzed within-day fluctuations in spiking activity and action potential amplitude recorded with silicon microelectrode arrays implanted in the motor cortex of three people with tetraplegia (BrainGate pilot clinical trial, IDE). MAIN RESULTS: 84% of the recorded units showed a statistically significant change in apparent firing rate (3.8 ± 8.71 Hz or 49% of the mean rate) across several-minute epochs of tasks performed on a single session, and 74% of the units showed a significant change in spike amplitude (3.7 ± 6.5 µV or 5.5% of mean spike amplitude). 40% of the recording sessions showed a significant correlation in the occurrence of amplitude changes across electrodes, suggesting array micro-movement. Despite the relatively frequent amplitude changes, only 15% of the observed within-day rate changes originated from recording artifacts such as spike amplitude change or electrical noise, while 85% of the rate changes most likely emerged from physiological mechanisms. Computer simulations confirmed that systematic rate changes of individual neurons could produce a directional 'bias' in the decoded neural cursor movements. Instability in apparent neuronal spike rates indeed yielded a directional bias in 56% of all performance assessments in participant cursor control (n = 2 participants, 108 and 20 assessments over two years), resulting in suboptimal performance in these sessions. SIGNIFICANCE: We anticipate that signal acquisition and decoding methods that can adapt to the reported instabilities will further improve the performance of intracortically-based NISs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In the CNS, small signal amplitudes, signal instability, and signal loss over time are often observed.14,15”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [15]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This may undermine the detection and decoding efficacy of brain-machine interfaces and closed-loop neurostimulation applications in which the stimulus is conditioned on a recorded neural signal.1,15”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [15]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“any differences in average firing rates observed between two behaviors collected in separate blocks could be due to spurious drifts in firing rates known to occur across time63,64.”
From Inner speech in motor cortex and implications for speech neuroprostheses (2025) · cites this paper as [64]
The cited source says what the claim attributes to it.
In the citing paper
“While the ‘isolated ’verbal behavior experiments (section 3) allowed us to explore a large number of behaviors, it did not allow us to assess differences in neural representation between behaviors, because any differences between blocks could also be caused by spurious neural nonstationarity known to be occur in microelectrode array recordings63,64.”
From Inner speech in motor cortex and implications for speech neuroprostheses (2025) · cites this paper as [64]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482 · cited 1×
“We used the Benjamini–Hochberg procedure (Benjamini and Hochberg 1995) with a correction for dependent statistics (Benjamini and Yekutieli 2001) to set the false discovery rate within a session at the level of 5% for all tests.”
The control of the false discovery rate in multiple testing under dependency
Benjamini, Y., & Yekutieli, D. (2001) · The Annals of Statistics · doi:10.1214/aos/1013699998 · Cited by 10,490 · cited 1×
“We used the Benjamini–Hochberg procedure (Benjamini and Hochberg 1995) with a correction for dependent statistics (Benjamini and Yekutieli 2001) to set the false discovery rate within a session at the level of 5% for all tests.”
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Self-citationReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Self-citationHigh-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591 · cited 1×
“…Taylor et al 2002, Lebedev et al 2005, Serruya et al 2002), in people with tetraplegia (Chadwick et al 2011, Kim et al 2008, Simeral et al 2011a, Hochberg et al 2006), or to perform actions with a robotic limb in macaques (Velliste et al 2008) or humans (Hochberg et al 2012, Collinger et al 2012).”
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409 · cited 1×
“…to control a computer cursor on a screen in intact macaques (Ganguly and Carmena 2009, Carmena et al 2003, Taylor et al 2002, Lebedev et al 2005, Serruya et al 2002), in people with tetraplegia (Chadwick et al 2011, Kim et al 2008, Simeral et al 2011a, Hochberg et al 2006), or to perform…”
BackgroundSelf-citationTruccolo, W., Eden, U. T., Fellows, M. R., Donoghue, J. P., & Brown, E. N. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00697.2004 · Cited by 1,049 · cited 1×
“Thus modeling the observed (Truccolo et al 2005, Wu and Hatsopoulos 2008) or hidden sources of variability (Stevenson et al 2010, Lawhern et al 2010, Wood et al 2005, Kulkarni and Paninski 2007) could provide further improvement in decoding performance.”
Self-citation
Research works printed but not linked: 3
- Homer ML, Perge JA, Hochberg LR. Mitigating nonstationarities during neural cursor control with noise offset correction. Society for Neuroscience Annual Meeting, 142.03/E18 2011 [Google Scholar]
- Nuyujukian P, Kao JC, Fan JM, Stavisky SD, Ryu S, Shenoy K. COSYNE. Salt Lake City, Utah: 2012. A high–performance, robust brain–machine interface without retraining. [Google Scholar]
- Simeral JD, Perge JA, Masse NY, Jarosiewicz B, Bacher D, Donoghue J, Hochberg LR. Some preliminary longitudinal findings from five trial participants using the BrainGate neural interface system. Society for Neuroscience. 2011b;41 [Google Scholar]
Cited by
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
“There is a growing consensus in the literature that research should continue into developing better recording technologies suitable for humans (251, 271, 391, 624, 646).”
BackgroundGlial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
“Many of these shifts seem to be related to device micromotion (based on simultaneous effects observed across electrode sites) 13 , but the vast majority were attributed to a physiological origin (85%).”
InfluentialUltraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612
Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
Xie, C., Liu, J., Fu, T.-M., Dai, X., Zhou, W., & Lieber, C. M. (2015) · Nature Materials · doi:10.1038/nmat4427 · Cited by 404
“Evidence suggests that mechanical mismatch is an important reason leading to abrupt and chronically unstable interfaces within the brain 4, 22 .”
BackgroundRestoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368
Jarosiewicz, B., Sarma, A. A., Bacher, D., Masse, N. Y., Simeral, J. D., Sorice, B., Oakley, E. M., Blabe, C., Pandarinath, C., Gilja, V., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac7328 · Cited by 340
Self-citationStable long-term chronic brain mapping at the single-neuron level
Fu, T.-M., Hong, G., Zhou, T., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2016) · Nature Methods · doi:10.1038/nmeth.3969 · Cited by 330
An Accurate and Rapidly Calibrating Speech Neuroprosthesis
Card, N. S., Wairagkar, M., Iacobacci, C., Hou, X., Singer-Clark, T., Willett, F. R., Kunz, E. M., Fan, C., Vahdati Nia, M., Deo, D. R., et al. (2024) · New England Journal of Medicine · doi:10.1056/nejmoa2314132 · Cited by 268
Self-citationAn accurate and rapidly calibrating speech neuroprosthesis
Card, N. S., Wairagkar, M., Iacobacci, C., Hou, X., Singer-Clark, T., Willett, F. R., Kunz, E. M., Fan, C., Vahdati Nia, M., Deo, D. R., et al. (2023) · doi:10.1101/2023.12.26.23300110 · Cited by 244
“Previous studies have reported that intracortical devices often require recalibration due to signal nonstationarities 28–30 .”
BackgroundSelf-citationAdvances in closed-loop deep brain stimulation devices
Parastarfeizabadi, M., & Kouzani, A. Z. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0295-1 · Cited by 232
“Moreover, there is a need for recalibration processes to keep the stability of feedback signal [44].”
BackgroundBrain–machine interfaces for controlling lower-limb powered robotic systems
He, Y., Eguren, D., Azorín, J. M., Grossman, R. G., Luu, T. P., & Contreras-Vidal, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa8c0 · Cited by 224
Making brain–machine interfaces robust to future neural variability
Sussillo, D., Stavisky, S. D., Kao, J. C., Ryu, S. I., & Shenoy, K. V. (2016) · Nature Communications · doi:10.1038/ncomms13749 · Cited by 213
Degenhart, A. D., Bishop, W. E., Oby, E. R., Tyler-Kabara, E. C., Chase, S. M., Batista, A. P., & Yu, B. M. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0542-9 · Cited by 212
Acute human brain responses to intracortical microelectrode arrays: challenges and future prospects
Fernández, E., Greger, B., House, P. A., Aranda, I., Botella, C., Albisua, J., Soto-Sánchez, C., Alfaro, A., & Normann, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00024 · Cited by 141
“The UEA has been used in BrainGate clinical trials (Hochberg et al., 2006; Homer et al., 2013; Perge et al., 2013) and in research with epilepsy patients (Normann et al.”
MethodRapid calibration of an intracortical brain–computer interface for people with tetraplegia
Brandman, D. M., Hosman, T., Saab, J., Burkhart, M. C., Shanahan, B. E., Ciancibello, J. G., Sarma, A. A., Milstein, D. J., Vargas-Irwin, C. E., Franco, B., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9ee7 · Cited by 153
Self-citationSimeral, J. D., Hosman, T., Saab, J., Flesher, S. N., Vilela, M., Franco, B., Kelemen, J. N., Brandman, D. M., Ciancibello, J. G., Rezaii, P. G., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3069119 · Cited by 165
“discrepancies were most plausibly attributed to nonstationarities in the recorded intracortical signals [17] rather than failures in the wired or wireless systems.”
BackgroundSelf-citationSchwemmer, M. A., Skomrock, N. D., Sederberg, P. B., Ting, J. E., Sharma, G., Bockbrader, M. A., & Friedenberg, D. A. (2018) · Nature Medicine · doi:10.1038/s41591-018-0171-y · Cited by 163
Highly scalable multichannel mesh electronics for stable chronic brain electrophysiology
Fu, T.-M., Hong, G., Viveros, R. D., Zhou, T., & Lieber, C. M. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1717695114 · Cited by 155
“In addition, while there are publications showing that conventional rigid probes occasionally report long-term stable chronic recording from a small portion (typically <10%) of the implanted electrodes (44), these results are more of an exception, as many researchers using the same type of probes reported intraday ins…”
Stable long-term BCI-enabled communication in ALS and locked-in syndrome using LFP signals
Milekovic, T., Sarma, A. A., Bacher, D., Simeral, J. D., Saab, J., Pandarinath, C., Sorice, B. L., Blabe, C., Oakley, E. M., Tringale, K. R., et al. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00493.2017 · Cited by 137
“It is difficult to reliably detect and isolate activity of single units within a day or from one day to the next (Dickey et al. 2009; Perge et al. 2013).”
BackgroundSelf-citationAutomated long-term recording and analysis of neural activity in behaving animals
Dhawale, A. K., Poddar, R., Wolff, S. B., Normand, V. A., Kopelowitz, E., & Ölveczky, B. P. (2017) · eLife · doi:10.7554/elife.27702 · Cited by 159
Mesh electronics: a new paradigm for tissue-like brain probes
Hong, G., Yang, X., Zhou, T., & Lieber, C. M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.11.007 · Cited by 159
Printing Flexible and Hybrid Electronics for Human Skin and Eye‐Interfaced Health Monitoring Systems
Kim, K., Kim, B., & Lee, C. H. (2020) · Advanced Materials · doi:10.1002/adma.201902051 · Cited by 147
Luan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
“In time scales as short as minutes (Gilletti and Muthuswamy, 2006) and hours (Fraser and Schwartz, 2012; Perge et al., 2013), substantial changes in recording condition can often occur due to the micro-movements of the implanted electrodes relative to the brain tissue (Gilletti and Muthuswamy, 2006).”
BackgroundIntracortical recording stability in human brain–computer interface users
Downey, J. E., Schwed, N., Chase, S. M., Schwartz, A. B., & Collinger, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab7a0 · Cited by 149
Recent Progress on Microelectrodes in Neural Interfaces
Kim, G. H., Kim, K., Lee, E., An, T., Choi, W., Lim, G., & Shin, J. H. (2018) · Materials · doi:10.3390/ma11101995 · Cited by 139
Hebb, A. O., Zhang, J. J., Mahoor, M. H., Tsiokos, C., Matlack, C., Chizeck, H. J., & Pouratian, N. (2013) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2013.08.006 · Cited by 133
Decoding Movement From Electrocorticographic Activity: A Review
Volkova, K., Lebedev, M. A., Kaplan, A., & Ossadtchi, A. (2019) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2019.00074 · Cited by 110
Jarosiewicz, B., Masse, N. Y., Bacher, D., Cash, S. S., Eskandar, E., Friehs, G., Donoghue, J. P., & Hochberg, L. R. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046012 · Cited by 104
Self-citationThe state of clinical trials of implantable brain–computer interfaces
Patrick-Krueger, K. M., Burkhart, I., & Contreras-Vidal, J. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00239-5 · Cited by 125
Sensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
“Eighty-four percent of the features exhibited such nonstationary behavior while people with tetraplegia operated an iBCI (54).”
Self-citationThe sinusoidal probe: a new approach to improve electrode longevity
Sohal, H. S., Jackson, A., Jackson, R., Clowry, G. J., Vassilevski, K., O’Neill, A., & Baker, S. N. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00010 · Cited by 106
“ORIGINAL RESEARCH ARTICLE published: 29 April 2014 doi: 10.3389/fneng.2014.00010 The sinusoidal probe: a new approach to improve electrode longevity”
InfluentialReview: Human Intracortical Recording and Neural Decoding for Brain–Computer Interfaces
Brandman, D. M., Cash, S. S., & Hochberg, L. R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2677443 · Cited by 103
“[134], [157].”
Self-citationPower-saving design opportunities for wireless intracortical brain–computer interfaces
Even-Chen, N., Muratore, D. G., Stavisky, S. D., Hochberg, L. R., Henderson, J. M., Murmann, B., & Shenoy, K. V. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0595-9 · Cited by 118
“63,69,72 ).”
Self-citationApplications of brain-computer interfaces to the control of robotic and prosthetic arms
Vilela, M., & Hochberg, L. R. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00008-1 · Cited by 118
Self-citationWillsey, M. S., Shah, N. P., Avansino, D. T., Hahn, N. V., Jamiolkowski, R. M., Kamdar, F. B., Hochberg, L. R., Willett, F. R., & Henderson, J. M. (2025) · Nature Medicine · doi:10.1038/s41591-024-03341-8 · Cited by 120
“As a control to understand how neural instabilities 46 could affect decoding performance, the stability of the 4D decoder was evaluated during two research sessions by training an initial decoder, fixing the parameters and using this fixed decoder on consecutive blocks until trials could not be…”
Self-citationStabilizing brain-computer interfaces through alignment of latent dynamics
Karpowicz, B. M., Ali, Y. H., Wimalasena, L. N., Sedler, A. R., Keshtkaran, M. R., Bodkin, K. L., Ma, X., Rubin, D. B., Williams, Z. M., Cash, S. S., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-59652-y · Cited by 115
“Despite these impressive demonstrations, a key challenge limiting the clinical deployment of iBCIs is their robustness to neuronal recording instabilities that cause changes in the particular neurons being monitored over time 7–10 .”
Self-citationDowney, J. E., Weiss, J. M., Muelling, K., Venkatraman, A., Valois, J.-S., Hebert, M., Bagnell, J. A., Schwartz, A. B., & Collinger, J. L. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0134-9 · Cited by 111
“changes in the recorded units [6].”
Perge, J. A., Zhang, S., Malik, W. Q., Homer, M. L., Cash, S., Friehs, G., Eskandar, E. N., Donoghue, J. P., & Hochberg, L. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046007 · Cited by 100
Self-citationUltraflexible Neural Electrodes for Long-Lasting Intracortical Recording
He, F., Lycke, R., Ganji, M., Xie, C., & Luan, L. (2020) · iScience · doi:10.1016/j.isci.2020.101387 · Cited by 105
Decoding spoken English from intracortical electrode arrays in dorsal precentral gyrus
Wilson, G. H., Stavisky, S. D., Willett, F. R., Avansino, D. T., Kelemen, J. N., Hochberg, L. R., Henderson, J. M., Druckmann, S., & Shenoy, K. V. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abbfef · Cited by 103
“Second, more slowly-varying artificial neural input feature drifts were added across the time bins of each snippet during training tomake the RNN robust to potential nonstationarities in the neural data (Perge et al 2013, Jarosiewicz et al 2015, Downey et al 2018a).”
BackgroundSelf-citationLatent Factors and Dynamics in Motor Cortex and Their Application to Brain–Machine Interfaces
Pandarinath, C., Ames, K. C., Russo, A. A., Farshchian, A., Miller, L. E., Dyer, E. L., & Kao, J. C. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.1669-18.2018 · Cited by 103
“Furthermore, motor adaptation to a visuomotor rotation (Vyas et al., 2018), visuomotor scaling (Stavisky et al., 2017a), or a curl field (Perich and Miller, 2017; Perich et al., 2017) has been shown to modify the motor preparatory state.”
BackgroundIntracortical Recording Interfaces: Current Challenges to Chronic Recording Function
Gunasekera, B., Saxena, T., Bellamkonda, R., & Karumbaiah, L. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn5002864 · Cited by 93
Conjugated Polymer for Implantable Electronics toward Clinical Application
Liu, Y., Feig, V. R., & Bao, Z. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202001916 · Cited by 95
Neural Decoding for Intracortical Brain–Computer Interfaces
Dong, Y., Wang, S., Huang, Q., Berg, R. W., Li, G., & He, J. (2023) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0044 · Cited by 92
“3) [48,49], so fixed decoders may not be suitable for iBCI systems over time.”
BackgroundSelectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88
“These changes can affect the stimulation and recording abilities of the electrodes for sensory feedback or decoding the attempted movements (Perge et al., 2013).”
The science and engineering behind sensitized brain-controlled bionic hands
Pandarinath, C., & Bensmaïa, S. J. (2021) · Physiological Reviews · doi:10.1152/physrev.00034.2020 · Cited by 91
Brain control of bimanual movement enabled by recurrent neural networks
Deo, D. R., Willett, F. R., Avansino, D. T., Hochberg, L. R., Henderson, J. M., & Shenoy, K. V. (2024) · Scientific Reports · doi:10.1038/s41598-024-51617-3 · Cited by 87
Self-citationReplay of Learned Neural Firing Sequences during Rest in Human Motor Cortex
Eichenlaub, J.-B., Jarosiewicz, B., Saab, J., Franco, B., Kelemen, J., Halgren, E., Hochberg, L. R., & Cash, S. S. (2020) · Cell Reports · doi:10.1016/j.celrep.2020.107581 · Cited by 69
“Prior to creating neural activity templates, each channel’s features were adaptively z-scored over time with a 120 s time constant to reduce the effects of any nonstationarities in feature means and standard deviations (Jarosiewicz et al., 2016; Perge et al., 2013) that might otherwise spuriously affect correlations a…”
BackgroundMethodSelf-citationBrain-computer interfaces for communication
Vansteensel, M. J., & Jarosiewicz, B. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00007-x · Cited by 85
“In other words, the relationship between movement intention and the recorded neural signals can change over time and across different contexts (Kim et al., 2006; Jarosiewicz et al., 2013, 2015; Perge et al., 2013).”
BackgroundDeep brain stimulation: a review of the open neural engineering challenges
Vissani, M., Isaias, I. U., & Mazzoni, A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abb581 · Cited by 81
“Solid-State Circuits 42 123–33 [239] Perge J A, Homer M L, Malik W Q, Cash S, Eskandar E, Friehs G, Donoghue J P and Hochberg L R 2013 Intra-day signal instabilities affect decoding performance in an intracortical neural interface system J.”
BackgroundBrain2Char: a deep architecture for decoding text from brain recordings
Sun, P., Anumanchipalli, G. K., & Chang, E. F. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abc742 · Cited by 77
Sohal, H. S., Clowry, G. J., Jackson, A., O’Neill, A., & Baker, S. N. (2016) · PLOS ONE · doi:10.1371/journal.pone.0165606 · Cited by 64
Long-term intracortical microelectrode array performance in a human: a 5 year retrospective analysis
Colachis, S. C., Dunlap, C. F., Annetta, N. V., Tamrakar, S. M., Bockbrader, M. A., & Friedenberg, D. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1add · Cited by 59
“For instance, we observed substantial day-to-day variability in the number of identified units and resting firing rate (figures 4(b) and (e)), consistent with previous NHP and human studies [48, 64, 65].”
ResultStabilizing brain-computer interfaces through alignment of latent dynamics
Karpowicz, B. M., Ali, Y. H., Wimalasena, L. N., Sedler, A. R., Keshtkaran, M. R., Bodkin, K., Ma, X., Miller, L. E., & Pandarinath, C. (2022) · doi:10.1101/2022.04.06.487388 · Cited by 71
Self-recalibrating classifiers for intracortical brain–computer interfaces
Bishop, W., Chestek, C. C., Gilja, V., Nuyujukian, P., Foster, J. D., Ryu, S. I., Shenoy, K. V., & Yu, B. M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026001 · Cited by 60
“Recently Perge et al (2013) investigated intracortical BCI signal stability within the context of decoding continuous control signals (i.e., regression) in closed-loop human experiments.”
BackgroundVansteensel, M. J., Klein, E., van Thiel, G., Gaytant, M., Simmons, Z., Wolpaw, J. R., & Vaughan, T. M. (2023) · Journal of Neurology · doi:10.1007/s00415-022-11464-6 · Cited by 59
Regenerative Electrode Interfaces for Neural Prostheses.
Thompson, C. H., Zoratti, M. J., Langhals, N. B., & Purcell, E. K. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0279 · Cited by 67
“14,15 This may undermine the detection and decoding efficacy of brain–machine interfaces and closed-loop neurostimulation applications in which the stimulus is conditioned on a recorded neural signal.”
Feedback control policies employed by people using intracortical brain–computer interfaces
Willett, F. R., Pandarinath, C., Jarosiewicz, B., Murphy, B. A., Memberg, W. D., Blabe, C. H., Saab, J., Walter, B. L., Sweet, J. A., Miller, J. P., et al. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2560/14/1/016001 · Cited by 57
“To account for changes in the mean value of neural features over time that can cause an offset (bias) to appear in u t [29], we updated our estimate of the feature means over the course of the session using methods similar to Jarosiewicz et al [7].”
MethodSelf-citationBullard, A. J., Hutchison, B. C., Lee, J., Chestek, C. A., & Patil, P. G. (2020) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.13069 · Cited by 65
Moly, A., Costecalde, T., Martel, F., Martin, M., Larzabal, C., Karakas, S., Verney, A., Charvet, G., Chabardes, S., Benabid, A. L., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac59a0 · Cited by 65
“They suffer from a decrease of signal-to-noise ratio over time [4, 5], a high across-day variation in the neural signals [6, 7] and still require wired recording systems despite recent efforts in this domain.”
BackgroundOstrow, M., Eisen, A. J., Kozachkov, L., & Fiete, I. (2023) · neural information processing systems · doi:10.52202/075280-1467 · Cited by 67
Syringe-injectable electronics with a plug-and-play input/output interface.
Schuhmann, T. G., Yao, J., Hong, G., Fu, T.-M., & Lieber, C. M. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b03081 · Cited by 63
Approaches to closed-loop deep brain stimulation for movement disorders
Kuo, C., White-Dzuro, G. A., & Ko, A. L. (2018) · Neurosurgical FOCUS · doi:10.3171/2018.5.focus18173 · Cited by 62
Bergeron, D., Iorio‐Morin, C., Bonizzato, M., Lajoie, G., Gaucher, N. O., Racine, É., & Weil, A. G. (2023) · Journal of Child Neurology · doi:10.1177/08830738231167736 · Cited by 61
Using adversarial networks to extend brain computer interface decoding accuracy over time
Ma, X., Rizzoglio, F., Bodkin, K. L., Perreault, E. J., Miller, L. E., & Kennedy, A. (2023) · eLife · doi:10.7554/elife.84296 · Cited by 59
Murphy, M. D., Guggenmos, D. J., Bundy, D. T., & Nudo, R. J. (2016) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2015.00497 · Cited by 59
“This problem of varying tuning is also seen in recordings from units in motor cortex (Perge et al., 2013).”
BackgroundMethodMotor cortex retains and reorients neural dynamics during motor imagery
Dekleva, B. M., Chowdhury, R. H., Batista, A. P., Chase, S. M., Yu, B. M., Boninger, M. L., & Collinger, J. L. (2024) · Nature Human Behaviour · doi:10.1038/s41562-023-01804-5 · Cited by 57
Tremblay, S., Doucet, G., Pieper, F., Sachs, A. J., & Martínez-Trujillo, J. (2015) · Journal of Neuroscience · doi:10.1523/jneurosci.1041-15.2015 · Cited by 57
“However, one problem with chronic MEA implants used in brain–machine interface applications is that the isolation of single units deteriorates over time (Dickey et al., 2009; Chestek et al., 2011; Perge et al., 2013).”
BackgroundInner speech in motor cortex and implications for speech neuroprostheses
Kunz, E. M., Abramovich Krasa, B., Kamdar, F., Avansino, D. T., Hahn, N., Yoon, S., Singh, A., Nason-Tomaszewski, S. R., Card, N. S., Jude, J. J., et al. (2025) · Cell · doi:10.1016/j.cell.2025.06.015 · Cited by 55
“59,60 In order to assess whether differences exist between the neural representation of attempted and inner speech (which could be a useful cue for a decoder to distinguish between them), we ran a follow-up task in which attempted speech, inner speech, and listening conditions were randomly…”
Self-citationRestoring Speech Using Brain–Computer Interfaces
Stavisky, S. D. (2025) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110122-012818 · Cited by 52
Hosman, T., Vilela, M., Milstein, D., Kelemen, J. N., Brandman, D. M., Hochberg, L. R., & Simeral, J. D. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8717140 · Cited by 51
Self-citationSommakia, S., Lee, H. C., Gaire, J., & Otto, K. J. (2014) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2014.07.005 · Cited by 47
“clinical studies offer unprecedented evaluation of device performance [47,113,46]; however, pre-clinical evaluation must still be conducted for new or modified devices.”
BackgroundTissue-like Neural Probes for Understanding and Modulating the Brain
Hong, G., Viveros, R. D., Zwang, T. J., Yang, X., & Lieber, C. M. (2018) · Biochemistry · doi:10.1021/acs.biochem.8b00122 · Cited by 43
Developing Next-Generation Brain Sensing Technologies—A Review
Robinson, J. T., Xie, C., Pohlmeyer, E. A., Gather, M. C., Kemere, C. T., Kitching, J. E., Malliaras, G. G., Marblestone, A. H., Shepard, K. L., & Stieglitz, T. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2931159 · Cited by 50
“to target neurons [56], which leads to sudden waveform changes on time scales as short as hours, preventing reliable tracking of individual neurons over days and longer [57], [58].”
BackgroundBrain–Machine Interfaces: Closed-Loop Control in an Adaptive System
Sorrell, E., Rule, M. E., & O’Leary, T. (2021) · Annual Review of Control Robotics and Autonomous Systems · doi:10.1146/annurev-control-061720-012348 · Cited by 51
Wang, S., Jiang, Q., Liu, H., Yu, C., Li, P., Pan, G., Xu, K., Xiao, R., Hao, Y., Wang, C., et al. (2024) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2403380121 · Cited by 46
Non-causal spike filtering improves decoding of movement intention for intracortical BCIs
Masse, N. Y., Jarosiewicz, B., Simeral, J. D., Bacher, D., Stavisky, S. D., Cash, S. S., Oakley, E. M., Berhanu, E., Eskandar, E., Friehs, G., et al. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.08.004 · Cited by 45
Self-citationGutiérrez-Martínez, J., Mercado-Gutierrez, J. A., Carvajal-Gámez, B. E., Rosas‐Trigueros, J. L., & Contreras-Martinez, A. E. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.772837 · Cited by 42
“However, this BCI approach face the risk of surgical complications and infections, short-term and longterm signal instabilities that degrade neural decoding of intent (Perge et al., 2013), and the challenge of maintaining stable chronic recordings (Meng et al.”
BackgroundCortivis approach for an Intracortical visual Prostheses
Fernández, E., & Normann, R. A. (2017) · Artificial Vision · doi:10.1007/978-3-319-41876-6_15 · Cited by 40
Neurophysiology and neural engineering: a review
Procházka, A. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00149.2017 · Cited by 40
“With current devices the recordings degrade within a year or so (Wodlinger et al. 2015), though it is possible to extract useful information even after this has occurred (Perge et al. 2013, 2014; Simeral et al. 2011).”
BackgroundAdaptive latent state modeling of brain network dynamics with real-time learning rate optimization
Yang, Y., Ahmadipour, P., & Shanechi, M. M. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcefd · Cited by 40
Wilson, G. H., Stein, E. A., Kamdar, F. B., Avansino, D. T., Pun, T. K., Gross, R., Hosman, T., Singer-Clark, T., Kapitonava, A., Hochberg, L. R., et al. (2025) · Nature Biomedical Engineering · doi:10.1038/s41551-025-01536-z · Cited by 40
Self-citationKey considerations in designing a somatosensory neuroprosthesis
Delhaye, B. P., Saal, H. P., & Bensmaïa, S. J. (2016) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2016.11.001 · Cited by 39
Thompson, C. H., Riggins, T. E., Patel, P. R., Chestek, C. A., Li, W., & Purcell, E. K. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab7030 · Cited by 38
Long-term independent use of an intracortical brain–computer interface for speech and cursor control
Card, N. S., Singer-Clark, T., Peracha, H., Iacobacci, C., Hou, X., Wairagkar, M., Fogg, Z., Offenberg, E. C., Hochberg, L. R., Stavisky, S. D., et al. (2026) · Nature Medicine · doi:10.1038/s41591-026-04414-6 · Cited by 39
“Second, neural recording sensors and decoding performance must remain stable over long durations despite the neural signal variability associated with chronic implants 19–21 .”
Self-citationSaalfrank, D., Konduri, A. K., Latifi, S., Habibey, R., Golabchi, A., Martiniuc, A. V., Knoll, A., Ingebrandt, S., & Blau, A. W. (2015) · Royal Society Open Science · doi:10.1098/rsos.150031 · Cited by 36
“Signal instability is a known issue and challenge in neuroprosthetics [39,40].”
BackgroundNeuroplasticity subserving the operation of brain–machine interfaces
Oweiss, K. G., & Badreldin, I. S. (2015) · Neurobiology of Disease · doi:10.1016/j.nbd.2015.05.001 · Cited by 36
Shaikh, S., So, R. Q., Sibindi, T. M., Libedinsky, C., & Basu, A. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2944486 · Cited by 36
Endovascular Brain-Computer Interfaces in Poststroke Paralysis
Brannigan, J., Fry, A., Opie, N. L., Campbell, B. C. V., Mitchell, P. J., & Oxley, T. J. (2023) · Stroke · doi:10.1161/strokeaha.123.037719 · Cited by 36
“17,19,20 Inherent instability of single unit recordings is believed to result from small device movements and changes to the regional extracellular milieu, 19 requiring frequent recalibration of devices.”
BackgroundFunctional remodeling of subtype-specific markers surrounding implanted neuroprostheses
Salatino, J. W., Winter, B. M., Drazin, M. H., & Purcell, E. K. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00162.2017 · Cited by 36
“The dynamic nature of the tissue response may contribute to fluctuations in detected signals and stimulation thresholds, which can occur on intra- and interday timescales (Chestek et al. 2011, Perge et al. 2013).”
BackgroundSyringe-injectable Mesh Electronics for Stable Chronic Rodent Electrophysiology
Schuhmann, T. G., Zhou, T., Hong, G., Lee, J. M., Fu, T.-M., Park, H., & Lieber, C. M. (2018) · Journal of Visualized Experiments · doi:10.3791/58003 · Cited by 35
3D-printed flexible neural probes for recordings at single-neuron level
Momin, M., Feng, L., Ahmed, S., Ren, J., Hossain, A., Zhang, S., & Zhou, T. (2024) · Device · doi:10.1016/j.device.2024.100519 · Cited by 34
Fan, C., Hahn, N. V., Kamdar, F. B., Avansino, D. T., Wilson, G. H., Hochberg, L. R., Shenoy, K. V., Henderson, J. M., & Willett, F. R. (2023) · neural information processing systems · doi:10.52202/075280-1831 · Cited by 34
“Nonstationarities are caused by various factors, including microelectrode array movement [40], device degradation [50], single neuron physiological changes [33, 9, 3], and variability at the behavioral level [7, 46].”
Self-citationPun, T. K., Khoshnevis, M., Hosman, T., Wilson, G. H., Kapitonava, A., Kamdar, F. B., Henderson, J. M., Simeral, J. D., Vargas-Irwin, C. E., Harrison, M. T., et al. (2024) · Communications Biology · doi:10.1038/s42003-024-06784-4 · Cited by 35
“Reviewer #2 (Remarks to the Author):”
InfluentialSelf-citationDunlap, C. F., Colachis, S. C., Meyers, E., Bockbrader, M. A., & Friedenberg, D. A. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.558987 · Cited by 33
Even-Chen, N., Stavisky, S. D., Pandarinath, C., Nuyujukian, P., Blabe, C. H., Hochberg, L. R., Henderson, J. M., & Shenoy, K. V. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2776204 · Cited by 29
“This can save training time and recalibration of the error-decoder, which is often needed for the kinematic decoder in a human BCI use [21], [62].”
BackgroundSelf-citationA neural network for online spike classification that improves decoding accuracy
Issar, D., Williamson, R. C., Khanna, S. B., & Smith, M. A. (2020) · Journal of Neurophysiology · doi:10.1152/jn.00641.2019 · Cited by 32
Mang, J., Xu, Z., Qi, Y., & Zhang, T. (2023) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2023.1271967 · Cited by 32
Biosignal-based co-adaptive user-machine interfaces for motor control
Madduri, M. M., Burden, S. A., & Orsborn, A. L. (2023) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2023.100462 · Cited by 32
“[22,23]).”
Metadata
- Authors
- Perge, J. A., Homer, M. L., Malik, W. Q., Cash, S., Eskandar, E., Friehs, G., Donoghue, J. P., & Hochberg, L. R.
- Affiliations
- Brown University (US)
- Harvard University (US)
- Rhode Island Hospital (US)
- Corresponding author
- Perge, János A
- Homer, Mark L
- Malik, Wasim Q
- Cash, Sydney
- Eskandar, Emad
- Friehs, Gerhard
- Donoghue, John P
- Hochberg, Leigh R
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-04-10
- Volume
- 10
- Issue
- 3
- Pages
- 036004
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC3693851
- OpenAlex
- W2047933600
- Cited by
- 243
- References
- 67
- Citations by year
- 2026: 20 · 2025: 17 · 2024: 31 · 2023: 19 · 2022: 13 · 2021: 16 · 2020: 25 · 2019: 14 · 2018: 19 · 2017: 21 · 2016: 15 · 2015: 11 · 2014: 16 · 2013: 5
- FWCI
- 7.69
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (n01hd53403-6-0-1)
- National Institute on Deafness and Other Communication Disorders (R01DC009899)
- National Institute of Neurological Disorders and Stroke (R01NS025074)
- National Institute of Biomedical Imaging and Bioengineering (R01EB007401)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (HHSN275201100018C, N01HD10018, N01 HD053403)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- motor cortex, tetraplegia, neural decoding, recording artifacts, adaptive decoding
- MeSH terms
- Adult, Algorithms, Circadian Rhythm, Electroencephalography, Female, Humans, Male, Middle Aged, Motor Cortex, Nerve Net, Quadriplegia, Sensitivity and Specificity, Reproducibility of Results, Evoked Potentials, Motor, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.