Motor neuron activation in peripheral nerves using infrared neural stimulation
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Localized activation of peripheral axons may improve selectivity of peripheral nerve interfaces. Infrared neural stimulation (INS) employs localized delivery to activate neural tissue. This study investigated INS to determine whether localized delivery limited functionality in larger mammalian nerves. APPROACH: The rabbit sciatic nerve was stimulated extraneurally with 1875 nm wavelength infrared light, electrical stimulation, or a combination of both. Infrared-sensitive regions (ISR) of the nerve surface and electromyogram (EMG) recruitment of the Medial Gastrocnemius, Lateral Gastrocnemius, Soleus, and Tibialis Anterior were the primary output measures. Stimulation applied included infrared-only, electrical-only, and combined infrared and electrical. MAIN RESULTS: 81% of nerves tested were sensitive to INS, with 1.7 ± 0.5 ISR detected per nerve. INS was selective to a single muscle within 81% of identified ISR. Activation energy threshold did not change significantly with stimulus power, but motor activation decreased significantly when radiant power was decreased. Maximum INS levels typically recruited up to 2-9% of any muscle. Combined infrared and electrical stimulation differed significantly from electrical recruitment in 7% of cases. SIGNIFICANCE: The observed selectivity of INS indicates that it may be useful in augmenting rehabilitation, but significant challenges remain in increasing sensitivity and response magnitude to improve the functionality of INS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode
Tyler, D. J., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569263 · Cited by 144
Self-citationPolasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142 · cited 2×
“Peripheral nerve interfaces are useful in restoring function to paralyzed limbs by stimulating the axons of lower motor neurons (Polasek et al 2009, Popovic et al 2007, Weber et al 2005).”
BackgroundSelf-citationSelective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130
Self-citationFisher, L. E., Tyler, D. J., Anderson, J. S., & Triolo, R. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046010 · Cited by 89
Self-citationCombined optical and electrical stimulation of neural tissue in vivo
Duke, A. R., Cayce, J. M., Malphrus, J. D., Konrad, P., Mahadevan-Jansen, A., & Jansen, E. D. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3257230 · Cited by 76
FitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73
Duke, A. R., Peterson, E., Mackanos, M. A., Atkinson, J., Tyler, D., & Jansen, E. D. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066006 · Cited by 45
Self-citation
Cited by
Optical Stimulation of Neurons
C. Thompson, A., R. Stoddart, P., & Jansen, E. D. (2015) · Current Molecular Imaging · doi:10.2174/2211555203666141117220611 · Cited by 105
“Hybrid electrical-optical stimulation has been used to show inhibition of electrical responses in vivo [72, 119] and spontaneous neural activity in vitro [100].”
BackgroundMethodCompliant peripheral nerve interfaces.
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcdbe · Cited by 60
“[164] Peterson E J and Tyler D J 2014 Motor neuron activation in”
BackgroundTransdermal optogenetic peripheral nerve stimulation
Maimon, B. E., Zorzos, A. N., Bendell, R., Harding, A., Fahmi, M., Srinivasan, S., Calvaresi, P., & Herr, H. M. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5e20 · Cited by 42
Metadata
- Authors
- Peterson, E. J., & Tyler, D. J.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-12-05
- Volume
- 11
- Issue
- 1
- Pages
- 016001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2121213838
- Cited by
- 54
- References
- 7
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Motor neuron activation in peripheral nerves using infrared neural stimulation. https://app.cochat.ai/papers/10.1088/1741-2560/11/1/016001
- The paper
- Peterson, E. J., & Tyler, D. J. (2014). Motor neuron activation in peripheral nerves using infrared neural stimulation. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/11/1/016001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.