Investigation of tDCS volume conduction effects in a highly realistic head model
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We investigate volume conduction effects in transcranial direct current stimulation (tDCS) and present a guideline for efficient and yet accurate volume conductor modeling in tDCS using our newly-developed finite element (FE) approach. APPROACH: We developed a new, accurate and fast isoparametric FE approach for high-resolution geometry-adapted hexahedral meshes and tissue anisotropy. To attain a deeper insight into tDCS, we performed computer simulations, starting with a homogenized three-compartment head model and extending this step by step to a six-compartment anisotropic model. MAIN RESULTS: We are able to demonstrate important tDCS effects. First, we find channeling effects of the skin, the skull spongiosa and the cerebrospinal fluid compartments. Second, current vectors tend to be oriented towards the closest higher conducting region. Third, anisotropic WM conductivity causes current flow in directions more parallel to the WM fiber tracts. Fourth, the highest cortical current magnitudes are not only found close to the stimulation sites. Fifth, the median brain current density decreases with increasing distance from the electrodes. SIGNIFICANCE: Our results allow us to formulate a guideline for volume conductor modeling in tDCS. We recommend to accurately model the major tissues between the stimulating electrodes and the target areas, while for efficient yet accurate modeling, an exact representation of other tissues is less important. Because for the low-frequency regime in electrophysiology the quasi-static approach is justified, our results should also be valid for at least low-frequency (e.g., below 100 Hz) transcranial alternating current stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Beckmann, C. F., Behrens, T. E. J., Woolrich, M. W., & Smith, S. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.015 · Cited by 11,314
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Effects of non-invasive cortical stimulation on skilled motor function in chronic stroke
Hummel, F. (2005) · Brain · doi:10.1093/brain/awh369 · Cited by 1,114
Fregni, F., & Pascual-Leone, A. (2007) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0530 · Cited by 823 · cited 1×
“An interesting question, raised in many tDCS experiments, is whether weak direct currents introduced to big electrodes positioned at the head surface can have therapeutic effects (Fregni and Pascual-Leone 2007).”
BackgroundTranscranial Alternating Current Stimulation Enhances Individual Alpha Activity in Human EEG
Zaehle, T., Rach, S., & Herrmann, C. S. (2010) · PLoS ONE · doi:10.1371/journal.pone.0013766 · Cited by 803
Self-citationJones, D. K. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20033 · Cited by 773
Modeling the current distribution during transcranial direct current stimulation
Miranda, P. C., Lomarev, M., & Hallett, M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.009 · Cited by 762
Cited by
Antal, A., Alekseichuk, I., Bikson, M., Brockmöller, J., Brunoni, A. R., Chen, R., Cohen, L. G., Dowthwaite, G., Ellrich, J., Flöel, A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.001 · Cited by 1,301
Self-citationDeterminants of the electric field during transcranial direct current stimulation
Opitz, A., Paulus, W., Will, S., Antunes, A., & Thielscher, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.033 · Cited by 690
Huang, Y., Liu, A. A., Lafon, B., Friedman, D., Dayan, M., Wang, X., Bikson, M., Doyle, W. K., Devinsky, O., & Parra, L. C. (2017) · eLife · doi:10.7554/elife.18834 · Cited by 556
Applications of transcranial direct current stimulation for understanding brain function
Filmer, H. L., Dux, P. E., & Mattingley, J. B. (2014) · Trends in Neurosciences · doi:10.1016/j.tins.2014.08.003 · Cited by 519
Li, L. M., Uehara, K., & Hanakawa, T. (2015) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2015.00181 · Cited by 477
“A comprehensive discussion of the development of such simulations is outside the scope of this paper and is reviewed in detail elsewhere (Bikson et al., 2012, 2013; Wagner et al., 2014).”
MethodInter-subject Variability in Electric Fields of Motor Cortical tDCS
Laakso, I., Tanaka, S., Koyama, S., De Santis, V., & Hirata, A. (2015) · Brain Stimulation · doi:10.1016/j.brs.2015.05.002 · Cited by 372
Transcranial Alternating Current and Random Noise Stimulation: Possible Mechanisms
Antal, A., & Herrmann, C. S. (2016) · Neural Plasticity · doi:10.1155/2016/3616807 · Cited by 357
Self-citationSelective Modulation of Interhemispheric Functional Connectivity by HD-tACS Shapes Perception
Helfrich, R. F., Knepper, H., Nolte, G., Strüber, D., Rach, S., Herrmann, C. S., Schneider, T. R., & Engel, A. K. (2014) · PLoS Biology · doi:10.1371/journal.pbio.1002031 · Cited by 320
Self-citationOn the importance of electrode parameters for shaping electric field patterns generated by tDCS
Saturnino, G. B., Antunes, A., & Thielscher, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.06.067 · Cited by 263
Huang, Y., Parra, L. C., & Haufe, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.12.019 · Cited by 259
Non-invasive Brain Stimulation: A Paradigm Shift in Understanding Brain Oscillations
Vosskuhl, J., Strüber, D., & Herrmann, C. S. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00211 · Cited by 239
“…in Human Neuroscience | www.frontiersin.org 13 May 2018 | Volume 12 | Article 211 Simultaneous to the advancements in stimulation protocols, another key to reach more precise stimulation is to estimate the target of the electric currents more precisely (Miranda et al., 2003; Wagner et al., 2014).”
BackgroundMethodSelf-citationSimulating Transcranial Direct Current Stimulation With a Detailed Anisotropic Human Head Model
Rampersad, S. M., Janssen, A. M., Lucka, F., Aydin, U., Lanfer, B., Lew, S., Wolters, C. H., Stegeman, D. F., & Oostendorp, T. F. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2308997 · Cited by 206
Self-citationAlam, M., Truong, D. Q., Khadka, N., & Bikson, M. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/12/4506 · Cited by 197
Vergallito, A., Feroldi, S., Pisoni, A., & Romero Lauro, L. J. (2022) · Brain Sciences · doi:10.3390/brainsci12050522 · Cited by 179
“Indeed, the effect of the polarizing current is not always homogenous due to the orientation of neurons [73,74].”
BackgroundThe FieldTrip-SimBio pipeline for EEG forward solutions
Vorwerk, J., Oostenveld, R., Piastra, M. C., Magyari, L., & Wolters, C. H. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0463-y · Cited by 172
“Examples of the use of geometry-adapted hexahedral meshes can be found in the studies of [25–27]; evaluations of the numerical accuracy achieved using geometry-adapted hexahedral meshes in sphere models were performed by [24, 28].”
MethodSelf-citationLiu, Q., Farahibozorg, S., Porcaro, C., Wenderoth, N., & Mantini, D. (2017) · Human Brain Mapping · doi:10.1002/hbm.23688 · Cited by 171
“We opted for a solution involving 12 tissue classes (skin, eyes, muscle, fat, spongy bone, compact bone, cortical/subcortical gray matter, cerebellar gray matter, cortical/subcortical white matter, cerebellar white matter, cerebrospinal fluid and brain stem), which represents the current state-of-the-art for studies m…”
BackgroundMethodInfluentialDose-controlled tDCS reduces electric field intensity variability at a cortical target site
Evans, C., Bachmann, C., Lee, J. S. A., Gregoriou, E., Ward, N., & Bestmann, S. (2020) · Brain Stimulation · doi:10.1016/j.brs.2019.10.004 · Cited by 164
Kunze, T., Hunold, A., Haueisen, J., Jirsa, V., & Spiegler, A. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.02.015 · Cited by 162
Magnetoencephalography in Cognitive Neuroscience: A Primer
Gross, J. (2019) · Neuron · doi:10.1016/j.neuron.2019.07.001 · Cited by 160
“Stimulation of a specific target area is only possible with the use of computational models that are based on realistic volume conductor models (Huang et al., 2017; Wagner et al., 2014) ideally derived from individual anatomical MRIs (Liu et al.”
BackgroundSocial Psychology and Noninvasive Electrical Stimulation: A Promising Marriage
Boggio, P. S., Rêgo, G. G., Marques, L. M., & Costa, T. L. (2016) · European Psychologist · doi:10.1027/1016-9040/a000247 · Cited by 13
“…known to have a low spatial focality, as it uses large electrodes, and the current might spread beyond the targeted area (although recent current flow models suggest that most of the current density is concentrated below the electrodes and dissipates in between electrodes, see Wagner et al., 2014).”
Background
Metadata
- Authors
- Wagner, S., Rampersad, S. M., Aydin, Ü., Vorwerk, J., Oostendorp, T. F., Neuling, T., Herrmann, C. S., Stegeman, D. F., & Wolters, C. H.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-12-05
- Volume
- 11
- Issue
- 1
- Pages
- 016002
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2107315764
- Cited by
- 177
- References
- 51
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.