Investigation of tDCS volume conduction effects in a highly realistic head model
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We investigate volume conduction effects in transcranial direct current stimulation (tDCS) and present a guideline for efficient and yet accurate volume conductor modeling in tDCS using our newly-developed finite element (FE) approach. APPROACH: We developed a new, accurate and fast isoparametric FE approach for high-resolution geometry-adapted hexahedral meshes and tissue anisotropy. To attain a deeper insight into tDCS, we performed computer simulations, starting with a homogenized three-compartment head model and extending this step by step to a six-compartment anisotropic model. MAIN RESULTS: We are able to demonstrate important tDCS effects. First, we find channeling effects of the skin, the skull spongiosa and the cerebrospinal fluid compartments. Second, current vectors tend to be oriented towards the closest higher conducting region. Third, anisotropic WM conductivity causes current flow in directions more parallel to the WM fiber tracts. Fourth, the highest cortical current magnitudes are not only found close to the stimulation sites. Fifth, the median brain current density decreases with increasing distance from the electrodes. SIGNIFICANCE: Our results allow us to formulate a guideline for volume conductor modeling in tDCS. We recommend to accurately model the major tissues between the stimulating electrodes and the target areas, while for efficient yet accurate modeling, an exact representation of other tissues is less important. Because for the low-frequency regime in electrophysiology the quasi-static approach is justified, our results should also be valid for at least low-frequency (e.g., below 100 Hz) transcranial alternating current stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Beckmann, C. F., Behrens, T. E. J., Woolrich, M. W., & Smith, S. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.015 · Cited by 11,314
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Effects of non-invasive cortical stimulation on skilled motor function in chronic stroke
Hummel, F. (2005) · Brain · doi:10.1093/brain/awh369 · Cited by 1,114
Fregni, F., & Pascual-Leone, A. (2007) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0530 · Cited by 823 · cited 1×
“An interesting question, raised in many tDCS experiments, is whether weak direct currents introduced to big electrodes positioned at the head surface can have therapeutic effects (Fregni and Pascual-Leone 2007).”
BackgroundTranscranial Alternating Current Stimulation Enhances Individual Alpha Activity in Human EEG
Zaehle, T., Rach, S., & Herrmann, C. S. (2010) · PLoS ONE · doi:10.1371/journal.pone.0013766 · Cited by 803
Self-citationJones, D. K. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20033 · Cited by 773
Modeling the current distribution during transcranial direct current stimulation
Miranda, P. C., Lomarev, M., & Hallett, M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.009 · Cited by 762
Shaping the Effects of Transcranial Direct Current Stimulation of the Human Motor Cortex
Nitsche, M. A., Doemkes, S., Karaköse, T., Antal, A., Liebetanz, D., Lang, N., Tergau, F., & Paulus, W. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01312.2006 · Cited by 738
Radman, T., Ramos, R. L., Brumberg, J. C., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.007 · Cited by 702
Safety and cognitive effect of frontal DC brain polarization in healthy individuals
Iyer, M. B., Mattu, U., Grafman, J., Lomarev, M., Sato, S., & Wassermann, E. M. (2005) · Neurology · doi:10.1212/01.wnl.0000152986.07469.e9 · Cited by 686
Boggio, P. S., Ferrucci, R., Rigonatti, S. P., Covre, P., Nitsche, M., Pascual-Leone, A., & Fregni, F. (2006) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2006.05.062 · Cited by 643
Considerations of quasi-stationarity in electrophysiological systems
Plonsey, R., & Heppner, D. B. (1967) · The Bulletin of Mathematical Biophysics · doi:10.1007/bf02476917 · Cited by 619
Optimized multi-electrode stimulation increases focality and intensity at target
Dmochowski, J. P., Datta, A., Bikson, M., Su, Y., & Parra, L. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046011 · Cited by 590
Transcranial direct current stimulation: A computer-based human model study
Wagner, T., Fregni, F., Fecteau, S., Grodzinsky, A., Zahn, M., & Pascual-Leone, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.027 · Cited by 567
The electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494
Transcranial direct current stimulation improves recognition memory in Alzheimer disease
Ferrucci, R., Mameli, F., Guidi, I., Mrakic-Sposta, S., Vergari, M., Marceglia, S., Cogiamanian, F., Barbieri, S., Scarpini, E., & Priori, A. (2008) · Neurology · doi:10.1212/01.wnl.0000317060.43722.a3 · Cited by 457
In Vivo Measurement of Cortical Impedance Spectrum in Monkeys: Implications for Signal Propagation
Logothetis, N. K., Kayser, C., & Oeltermann, A. (2007) · Neuron · doi:10.1016/j.neuron.2007.07.027 · Cited by 453
Windhoff, M., Opitz, A., & Thielscher, A. (2013) · Human Brain Mapping · doi:10.1002/hbm.21479 · Cited by 441
Conductivity tensor mapping of the human brain using diffusion tensor MRI
Tuch, D. S., Wedeen, V. J., Dale, A. M., George, J. S., & Belliveau, J. W. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.171473898 · Cited by 432
Correlation functions in the QCD vacuum
Shuryak, E. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.1 · Cited by 341
Datta, A., Baker, J. M., Bikson, M., & Fridriksson, J. (2011) · Brain Stimulation · doi:10.1016/j.brs.2010.11.001 · Cited by 325
Lang, N., Nitsche, M. A., Paulus, W., Rothwell, J. C., & Lemon, R. N. (2004) · Experimental Brain Research · doi:10.1007/s00221-003-1800-2 · Cited by 315
Sensitivity of Neurons to Weak Electric Fields
Francis, J. T., Gluckman, B. J., & Schiff, S. J. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-19-07255.2003 · Cited by 301
A Controlled Clinical Trial of Cathodal DC Polarization in Patients with Refractory Epilepsy
Fregni, F., Thome‐Souza, S., Nitsche, M. A., Freedman, S. D., Valente, K. D., & Pascual‐Leone, A. (2006) · Epilepsia · doi:10.1111/j.1528-1167.2006.00426.x · Cited by 295
Modeling of the human skull in EEG source analysis
Dannhauer, M., Lanfer, B., Wolters, C. H., & Knösche, T. R. (2011) · Human Brain Mapping · doi:10.1002/hbm.21114 · Cited by 268
Self-citationGood vibrations: Oscillatory phase shapes perception
Neuling, T., Rach, S., Wagner, S., Wolters, C. H., & Herrmann, C. S. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.07.024 · Cited by 265
Self-citationConductivities of Three-Layer Live Human Skull
Akhtari, M., Bryant, H. C., Mamelak, A. N., Flynn, E. R., Heller, L., Shih, J. J., Mandelkem, M., Matlachov, A., Ranken, D. M., Best, E. D., et al. (2002) · Brain Topography · doi:10.1023/a:1014590923185 · Cited by 240
Bossetti, C. A., Birdno, M. J., & Grill, W. M. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/005 · Cited by 232
Transcranial direct current stimulation (tDCS) in a realistic head model
Sadleir, R. J., Vannorsdall, T. D., Schretlen, D. J., & Gordon, B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.052 · Cited by 232
Neuling, T., Wagner, S., Wolters, C. H., Zaehle, T., & Herrmann, C. S. (2012) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2012.00083 · Cited by 227
Self-citationManipulation of phosphene thresholds by transcranial direct current stimulation in man
Antal, A., Kincses, T. Z., Nitsche, M. A., & Paulus, W. (2003) · Experimental Brain Research · doi:10.1007/s00221-003-1459-8 · Cited by 227
Chaturvedi, A., Butson, C. R., Lempka, S. F., Cooper, S. E., & McIntyre, C. C. (2010) · Brain Stimulation · doi:10.1016/j.brs.2010.01.003 · Cited by 211
The physics of hearing: fluid mechanics and the active process of the inner ear
Reichenbach, T., & Hudspeth, A. J. (2014) · Reports on Progress in Physics · doi:10.1088/0034-4885/77/7/076601 · Cited by 194
Chapter 26 Transcranial direct current stimulation (tDCS)
Paulus, W. (2003) · Supplements to Clinical Neurophysiology · doi:10.1016/s1567-424x(09)70229-6 · Cited by 191
Bifrontal transcranial direct current stimulation slows reaction time in a working memory task
Marshall, L., Mölle, M., Siebner, H. R., & Born, J. (2005) · BMC Neuroscience · doi:10.1186/1471-2202-6-23 · Cited by 168 · cited 1×
“A small (0.5–2 mA) or low intensity ( 0.5 mA, see, e.g., Jaeger et al 1987, Marshall et al 2005) current is introduced to the human head by at least one electrode (anode) and removed at another (cathode).”
InfluentialRULLMANN, M., ANWANDER, A., DANNHAUER, M., WARFIELD, S., DUFFY, F., & WOLTERS, C. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.009 · Cited by 161
Self-citationPredicted current densities in the brain during transcranial electrical stimulation
Holdefer, R. N., Sadleir, R., & Russell, M. J. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.02.020 · Cited by 154
Parazzini, M., Fiocchi, S., Rossi, E. G., Paglialonga, A., & Ravazzani, P. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2116019 · Cited by 142
Manola, L., Roelofsen, B. H., Holsheimer, J., Marani, E., & Geelen, J. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345810 · Cited by 132
Diffeomorphic susceptibility artifact correction of diffusion-weighted magnetic resonance images
Ruthotto, L., Kugel, H., Olesch, J., Fischer, B., Modersitzki, J., Burger, M., & Wolters, C. H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/18/5715 · Cited by 126
Self-citationSalvador, R., Mekonnen, A., Ruffini, G., & Miranda, P. C. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626315 · Cited by 99
Wolters, C. H., Anwander, A., Berti, G., & Hartmann, U. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.890736 · Cited by 98
Self-citationCamacho, D., Hopper, R. H., Lin, G. M., & Myers, B. S. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00073-0 · Cited by 98
Target Optimization in Transcranial Direct Current Stimulation
Sadleir, R. J., Vannorsdall, T. D., Schretlen, D. J., & Gordon, B. (2012) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2012.00090 · Cited by 94
Role of Soft Bone, CSF and Gray Matter in EEG Simulations
Ramon, C., Schimpf, P. H., Haueisen, J., Holmes, M., & Ishimaru, A. (2004) · Brain Topography · doi:10.1023/b:brat.0000032859.68959.76 · Cited by 91
Modeling transcranial DC stimulation
Oostendorp, T. F., Hengeveld, Y. A., Wolters, C. H., Stinstra, J. G., van Elswijk, G., & Stegeman, D. F. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650142 · Cited by 41
Self-citationSuh, H. S., Kim, S. H., Lee, W. H., & Kim, T.-S. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333686 · Cited by 36
Jaeger, D., Elbert, T. R., Lutzenberger, W., & Birbaumer, N. (1987) · Journal of Psychophysiology · Cited by 26
Cited by
Antal, A., Alekseichuk, I., Bikson, M., Brockmöller, J., Brunoni, A. R., Chen, R., Cohen, L. G., Dowthwaite, G., Ellrich, J., Flöel, A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.001 · Cited by 1,301
Self-citationDeterminants of the electric field during transcranial direct current stimulation
Opitz, A., Paulus, W., Will, S., Antunes, A., & Thielscher, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.033 · Cited by 690
Huang, Y., Liu, A. A., Lafon, B., Friedman, D., Dayan, M., Wang, X., Bikson, M., Doyle, W. K., Devinsky, O., & Parra, L. C. (2017) · eLife · doi:10.7554/elife.18834 · Cited by 556
Applications of transcranial direct current stimulation for understanding brain function
Filmer, H. L., Dux, P. E., & Mattingley, J. B. (2014) · Trends in Neurosciences · doi:10.1016/j.tins.2014.08.003 · Cited by 519
Li, L. M., Uehara, K., & Hanakawa, T. (2015) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2015.00181 · Cited by 477
“A comprehensive discussion of the development of such simulations is outside the scope of this paper and is reviewed in detail elsewhere (Bikson et al., 2012, 2013; Wagner et al., 2014).”
Method
Metadata
- Authors
- Wagner, S., Rampersad, S. M., Aydin, Ü., Vorwerk, J., Oostendorp, T. F., Neuling, T., Herrmann, C. S., Stegeman, D. F., & Wolters, C. H.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-12-05
- Volume
- 11
- Issue
- 1
- Pages
- 016002
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2107315764
- Cited by
- 177
- References
- 51
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.