The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex
Open accessAbstract
The viability of chronic neural microelectrodes for electrophysiological recording and stimulation depends on several factors, including the encapsulation of the implant by a reactive tissue response. We postulate that mechanical strains induced around the implant site may be one of the leading factors responsible for the sustained tissue response in chronic implants. The objectives of this study were to develop a finite-element model of the probe-brain tissue interface and analyze the effects of tethering forces, probe-tissue adhesion and stiffness of the probe substrate on the interfacial strains induced around the implant site. A 3D finite-element model of the probe-brain tissue microenvironment was developed and used to simulate interfacial strains created by 'micromotion' of chronically implanted microelectrodes. Three candidate substrates were considered: (a) silicon, (b) polyimide and (c) a hypothetical 'soft' material. Simulated tethering forces resulted in elevated strains both at the tip and at the sharp edges of the probe track in the tissue. The strain fields induced by a simulated silicon probe were similar to those induced by a simulated polyimide probe, albeit at higher absolute values for radial tethering forces. Simulations of poor probe-tissue adhesion resulted in elevated strains at the tip and delamination of the tissue from the probe. A tangential tethering force results in 94% reduction in the strain value at the tip of the polyimide probe track in the tissue, whereas the simulated 'soft' probe induced two orders of magnitude smaller values of strain compared to a simulated silicon probe. The model results indicate that softer substrates reduce the strain at the probe-tissue interface and thus may also reduce tissue response in chronic implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the polyimide material demonstrated a 94% reduction in applied strain to the surrounding tissue, while strain with the theoretical 6 MPa material was reduced by two orders of magnitude.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [169]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Mechanical Behavior of Materials
Hosford, W. F. (2005) · Cambridge University Press eBooks · doi:10.1017/cbo9780511810930 · Cited by 1,795
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Self-citationBrain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S. T., Spence, A. J., Isaacson, M. S., Craighead, H. G., Turner, J. N., & Shain, W. G. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 811
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Self-citationRegional, Directional, and Age-Dependent Properties of the Brain Undergoing Large Deformation
Prange, M. T., & Margulies, S. S. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1449907 · Cited by 636
Mechanical properties of brain tissue in tension
Miller, K., & Chinzei, K. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00234-2 · Cited by 636
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W. G., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M. S., & Craighead, H. G. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 603
Constitutive modelling of brain tissue: Experiment and theory
Miller, K., & Chinzei, K. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00092-4 · Cited by 525
Research works printed but not linked: 5
- Stensaas S S, 1976, Acta Neuropathol., 35, 187
- Muthuswamy J, 2003, 25th Annual Int. Conf. of EMBS
- Uwe Meyer J, 1996, 18th Annual Int. Conf. of the IEEE Engineering in Medicine and Biology Society
- Edell D J Kuzma J Petraitis D, 1996, 18th Annual Int. Conference of the IEEE Engineering in Medicine and Biology Society
- Hetke J F, 2003, 25th Annual Int. Conf. of the IEEE Engineering in Medicine and Biology Society
Cited by
Sorted by citations
Items 101–200 of 367
Chen, N., Luo, B., Patil, A. C., Wang, J., Gammad, G. G. L., Yi, Z., Liu, X., Yen, S.-C., Ramakrishna, S., & Thakor, N. V. (2020) · ACS Nano · doi:10.1021/acsnano.0c00672 · Cited by 64
SU-8 microprobe with microelectrodes for monitoring electrical impedance in living tissues
Tijero, M., Gabriel, G., Caro, J., Altuna, A., Hernández, R., Villa, R., Berganzo, J., Blanco, F. J., Salido, R., & Fernández, L. J. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.12.019 · Cited by 63
Influence of resveratrol release on the tissue response to mechanically adaptive cortical implants
Nguyen, J. K., Jorfi, M., Buchanan, K. L., Park, D. J., Foster, E. J., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.11.001 · Cited by 63
Foley, C. P., Nishimura, N., Neeves, K. B., Schaffer, C. B., & Olbricht, W. L. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9308-6 · Cited by 60
Hara, S. A., Kim, B. J., Kuo, J. T. W., Lee, C. D., Meng, E., & Pikov, V. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066020 · Cited by 57
Design and demonstration of an intracortical probe technology with tunable modulus
Simon, D., Charkhkar, H., John, C. S., Rajendran, S. H., Kang, T. H., Reit, R., Arreaga‐Salas, D., McHail, D. G., Knaack, G. L., Sloan, A. M., et al. (2016) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35896 · Cited by 59
Neural Probes for Chronic Applications
Kook, G., Lee, S., Lee, H., Cho, I., & Lee, H. J. (2016) · Micromachines · doi:10.3390/mi7100179 · Cited by 61
Cutrone, A., & Micera, S. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801345 · Cited by 58
Host response to microgel coatings on neural electrodes implanted in the brain
Gutowski, S. M., Templeman, K. L., South, A. B., Gaulding, J. C., Shoemaker, J. T., LaPlaca, M. C., Bellamkonda, R. V., Lyon, L. A., & Garcı́a, A. J. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34799 · Cited by 57
Highly-compliant, microcable neuroelectrodes fabricated from thin-film gold and PDMS
McClain, M. A., Clements, I. P., Shafer, R. H., Bellamkonda, R. V., LaPlaca, M. C., & Allen, M. G. (2011) · Biomedical Microdevices · doi:10.1007/s10544-010-9505-3 · Cited by 57
Shen, W., Karumbaiah, L., Liu, X., Saxena, T. K., Chen, S., Patkar, R., Bellamkonda, R. V., & Allen, M. G. (2015) · Microsystems & Nanoengineering · doi:10.1038/micronano.2015.10 · Cited by 61
Progress and challenges of implantable neural interfaces based on nature-derived materials
Riva, E. R., & Micera, S. (2021) · Bioelectronic Medicine · doi:10.1186/s42234-021-00067-7 · Cited by 59
A comparison of polymer substrates for photolithographic processing of flexible bioelectronics
Simon, D., Ware, T. H., Marcotte, R. J., Lund, B. R., Smith, D. W., Prima, M. A. D., Rennaker, R. L., & Voit, W. (2013) · Biomedical Microdevices · doi:10.1007/s10544-013-9782-8 · Cited by 57
Stiller, A. M., Usoro, J. O., Frewin, C. L., Danda, V. R., Ecker, M., Joshi‐Imre, A., Musselman, K. C., Voit, W. E., Modi, R., Pancrazio, J. J., et al. (2018) · Micromachines · doi:10.3390/mi9100500 · Cited by 56
Sillay, K. A., Kumbier, L., Ross, C., Brady, M., Alexander, A. L., Gupta, A. K., Adluru, N., Miranpuri, G. S., & Williams, J. C. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0650-0 · Cited by 54
Design and Implementation Challenges of Microelectrode Arrays: A Review
Ghane-Motlagh, B., & Sawan, M. (2013) · Materials Sciences and Applications · doi:10.4236/msa.2013.48059 · Cited by 57
McConnell, G. C., Schneider, T. M., Owens, D. J., & Bellamkonda, R. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895373 · Cited by 53
Novel diamond shuttle to deliver flexible neural probe with reduced tissue compression
Na, K., Sperry, Z. J., Lu, J., Vöröslakos, M., Parizi, S. S., Bruns, T. M., Yoon, E., & Seymour, J. P. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-0149-z · Cited by 51
Chen, C., Chuang, S.-C., Su, H., Hsu, W.-L., Yew, T., Chang, Y., Yeh, S., & Yao, D. (2011) · Lab on a Chip · doi:10.1039/c0lc00718h · Cited by 51
Khilwani, R., Gilgunn, P. J., Kozai, T. D. Y., Ong, X. C., Korkmaz, E., Gunalan, P. K., Cui, X. T., Fedder, G. K., & Özdoğanlar, O. B. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0125-4 · Cited by 51
Graudejus, O., Morrison, B., Goletiani, C. J., Yu, Z., & Wagner, S. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201102290 · Cited by 50
Engineering strategies towards overcoming bleeding and glial scar formation around neural probes
Otte, E., Vlachos, A., & Asplund, M. (2022) · Cell and Tissue Research · doi:10.1007/s00441-021-03567-9 · Cited by 54
Wireless opto-electro neural interface for experiments with small freely behaving animals
Jia, Y., Khan, W., Lee, B., Fan, B., Madi, F., Weber, A., Li, W., & Ghovanloo, M. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac810 · Cited by 47
Micro- and Nanotechnologies for Optical Neural Interfaces
Pisanello, F., Sileo, L., & Vittorio, M. D. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00070 · Cited by 49
Sommakia, S., Lee, H. C., Gaire, J., & Otto, K. J. (2014) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2014.07.005 · Cited by 48
Influence of strain rate on indentation response of porcine brain
Qian, L., Zhao, H., Guo, Y., Li, Y., Zhou, M., Yang, L., Wang, Z., & Sun, Y. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.03.031 · Cited by 45
Carnicer-Lombarte (2019) · doi:10.1101/829648 · Cited by 46
Spencer, K. C., Sy, J. C., Falcón‐Banchs, R., & Cima, M. J. (2017) · Lab on a Chip · doi:10.1039/c6lc01411a · Cited by 47
Physiological properties of brain-machine interface input signals
Slutzky, M. W., & Flint, R. D. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00070.2017 · Cited by 47
SU-8-based microneedles forin vitroneural applications
Altuna, A., Gabriel, G., de la Prida, L. M., Tijero, M., Guimerà‐Brunet, A., Berganzo, J., Salido, R., Villa, R., & Fernández, L. J. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/6/064014 · Cited by 45
Malekoshoaraie, M. H., Wu, B., Krahe, D. D., Ahmed, Z., Pupa, S., Jain, V., Cui, X. T., & Chamanzar, M. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-024-00685-6 · Cited by 48
Maiolo, L., Guarino, V., Saracino, E., Convertino, A., Melucci, M., Muccini, M., Ambrosio, L., Zamboni, R., & Benfenati, V. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202001268 · Cited by 49
Mechanically Matched Silicone Brain Implants Reduce Brain Foreign Body Response
Zhang, E. N., Clément, J., Alameri, A., Ng, A., Kennedy, T. E., & Juncker, D. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202000909 · Cited by 43
Nanostructured Coatings for Improved Charge Delivery to Neurons
Kozai, T. D. Y., Alba, N. A., Zhang, H., Kotov, N. A., Gaunt, R. A., & Cui, X. T. (2014) · Springer eBooks · doi:10.1007/978-1-4899-8038-0_4 · Cited by 43
Conducting polymer electrodes for auditory brainstem implants
Guex, A., Vachicouras, N., Hight, A. E., Brown, M. C., Lee, D. J., & Lacour, S. P. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00099h · Cited by 45
Integration of High-Charge-Injection-Capacity Electrodes onto Polymer Softening Neural Interfaces
Arreaga‐Salas, D., Avendaño-Bolívar, A., Simon, D., Reit, R., Garcia‐Sandoval, A., Rennaker, R. L., & Voit, W. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b08139 · Cited by 41
Brain-Machine Interface Engineering
Sanchez, J. C., & Príncipe, J. C. (2007) · Synthesis lectures on biomedical engineering · doi:10.1007/978-3-031-01621-9 · Cited by 42
Yousif, N., Bayford, R. H., Shuo, W. A. N. G., & Liu, X. (2008) · Neuroscience · doi:10.1016/j.neuroscience.2008.01.023 · Cited by 40
Thompson, C. H., Riggins, T. E., Patel, P. R., Chestek, C. A., Li, W., & Purcell, E. K. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab7030 · Cited by 38
Next-Generation Diamond Electrodes for Neurochemical Sensing: Challenges and Opportunities
Purcell, E. K., Becker, M., Guo, Y., Hara, S. A., Ludwig, K. A., McKinney, C., Monroe, E., Rechenberg, R., Rusinek, C. A., Saxena, A., et al. (2021) · Micromachines · doi:10.3390/mi12020128 · Cited by 41
Engineering and commercialization of human-device interfaces, from bone to brain
Tate, M. L. K., Detamore, M. S., Capadona, J. R., Woolley, A. J., & Knothe, U. R. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.03.038 · Cited by 40
Vitale, F., Shen, W., Driscoll, N., Burrell, J. C., Richardson, A. G., Adewole, D. O., Murphy, B. B., Ananthakrishnan, A., Oh, H., Wang, T., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0206137 · Cited by 39
Computational assessment of neural probe and brain tissue interface under transient motion.
Polanco, M., Bawab, S., & Yoon, H. (2016) · Biosensors · doi:10.3390/bios6020027 · Cited by 36
Research Progress on the Flexibility of an Implantable Neural Microelectrode
Zhao, H., Liu, R., Zhang, H., Cao, P., Liu, Z., & Li, Y. (2022) · Micromachines · doi:10.3390/mi13030386 · Cited by 37
Fabrication and evaluation of conductive elastomer electrodes for neural stimulation
Keohan, F. L., Wei, X. F., Wongsarnpigoon, A., Lazaro, E., Darga, J. E., & Grill, W. M. (2007) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856207781494395 · Cited by 36
Magnetic PEDOT hollow capsules with single holes
Luo, S., Jiang, J., Liour, S. S., Gao, S., Ying, J. Y., & Yu, H. (2009) · Chemical Communications · doi:10.1039/b821989c · Cited by 36
Thiol‐ C lick Chemistries for Responsive Neural Interfaces
Ware, T. H., Simon, D., Hearon, K., Kang, T. H., Maitland, D. J., & Voit, W. E. (2013) · Macromolecular Bioscience · doi:10.1002/mabi.201300272 · Cited by 35
Ejserholm, F., Stegmayr, J., Bauer, P., Johansson, F., Wallman, L., Bengtsson, M., & Oredsson, S. (2015) · Biomaterials Research · doi:10.1186/s40824-015-0041-3 · Cited by 35
Singh, S., Lo, M.-C., Damodaran, V. B., Kaplan, H. M., Kohn, J., Zahn, J. D., & Shreiber, D. I. (2016) · Sensors · doi:10.3390/s16030330 · Cited by 34
From softening polymers to multimaterial based bioelectronic devices
Ecker, M., Joshi-Imre, A., Modi, R., Frewin, C. L., Garcia-Sandoval, A., Maeng, J., Gutierrez-Heredia, G., Pancrazio, J. J., & Voit, W. E. (2019) · Multifunctional Materials · doi:10.1088/2399-7532/aaed58 · Cited by 34
Paralikar, K. J., & Clement, R. S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923150 · Cited by 34
3D-printed flexible neural probes for recordings at single-neuron level
Momin, M., Feng, L., Ahmed, S., Ren, J., Hossain, A., Zhang, S., & Zhou, T. (2024) · Device · doi:10.1016/j.device.2024.100519 · Cited by 33
Mechanical Cycling Stability of Organic Thin Film Transistors on Shape Memory Polymers
Avendaño-Bolívar, A., Ware, T. H., Arreaga‐Salas, D., Simon, D., & Voit, W. (2013) · Advanced Materials · doi:10.1002/adma.201203976 · Cited by 33
CHIME: CMOS-Hosted in vivo Microelectrodes for Massively Scalable Neuronal Recordings
Köllő, M., Rácz, R., Hanna, M.-E., Obaid, A., Angle, M. R., Wray, W., Kong, Y., Hierlemann, A. R., Müller, J., Melosh, N. A., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00834 · Cited by 31
Huang, S.-H., Lin, S., & Chen, J. J. (2014) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2014.06.005 · Cited by 33
Overcoming failure: improving acceptance and success of implanted neural interfaces
Dalrymple, A. N., Jones, S. T., Fallon, J. B., Shepherd, R. K., & Weber, D. J. (2025) · Bioelectronic Medicine · doi:10.1186/s42234-025-00168-7 · Cited by 38
Degradable, silyl ether thiol–ene networks
Ware, T. H., Jennings, A. R., Bassampour, Z. S., Simon, D., Son, D. Y., & Voit, W. (2014) · RSC Advances · doi:10.1039/c4ra06997h · Cited by 32
Advancements in Biological Neural Interfaces Using Conducting Polymers: A Review
Parashar, K., Prajapati, D. G., McIntyre, R., & Kandasubramanian, B. (2020) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.0c00174 · Cited by 32
Hess‐Dunning, A., & Tyler, D. J. (2018) · Micromachines · doi:10.3390/mi9110583 · Cited by 32
Mechanically Robust, Softening Shape Memory Polymer Probes for Intracortical Recording
Stiller, A. M., Usoro, J. O., Lawson, J. M., Araya, B., González‐González, M. A., Danda, V. R., Voit, W. E., Black, B., & Pancrazio, J. J. (2020) · Micromachines · doi:10.3390/mi11060619 · Cited by 30
Intracortical Microelectrode Array Unit Yield under Chronic Conditions: A Comparative Evaluation
Usoro, J. O., Sturgill, B. S., Musselman, K. C., Capadona, J. R., & Pancrazio, J. J. (2021) · Micromachines · doi:10.3390/mi12080972 · Cited by 34
He, W. J., & Bellamkonda, R. V. (2007) · Frontiers in neuroengineering series/Frontiers in neuroengineering · doi:10.1201/9781420009309.pt4 · Cited by 32
CMOS Neural Probe With 1600 Close-Packed Recording Sites and 32 Analog Output Channels
Herbawi, A. S., Christ, O., Kiessner, L., Mottaghi, S., Hofmann, U., Paul, O., & Ruther, P. (2018) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2018.2872619 · Cited by 30
Ceyssens, F., Carmona, M. B., Kil, D., Deprez, M., Tooten, E., Nuttin, B., Takeoka, A., Balschun, D., Kraft, M. D., & Puers, R. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.12.030 · Cited by 29
Perna, A., Angotzi, G. N., Berdondini, L., & Ribeiro, J. F. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1275908 · Cited by 30
An intrinsically stretchable power-source system for bioelectronics
Cheng, P., Dai, S., Liu, Y., Li, Y., Hayashi, H., Papani, R., Su, Q., Li, N., Dai, Y., Liu, W., et al. (2023) · Device · doi:10.1016/j.device.2023.100216 · Cited by 29
Nicolai, E. N., Michelson, N. J., Settell, M. L., Hara, S. A., Trevathan, J. K., Asp, A. J., Stocking, K. C., Luján, J. L., Kozai, T. D. Y., & Ludwig, K. A. (2018) · Micromachines · doi:10.3390/mi9100494 · Cited by 26
Bedell, H. W., Song, S., Li, X., Molinich, E., Lin, S., Stiller, A. M., Danda, V. R., Ecker, M., Shoffstall, A. J., Voit, W. E., et al. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00772 · Cited by 29
Dunlap, C. F., Colachis, S. C., Meyers, E., Bockbrader, M. A., & Friedenberg, D. A. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.558987 · Cited by 30
Soft optical fiber curvature sensor for finger joint angle proprioception
Li, H., Li, H., Lou, X., Meng, F., & Zhu, L. (2018) · Optik · doi:10.1016/j.ijleo.2018.10.187 · Cited by 28
Design and Fabrication of a Flexible Substrate Microelectrode Array for Brain Machine Interfaces
Patrick, E. E., Ordonez, M., Alba, N. A., Sanchez, J. C., & Nishida, T. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260581 · Cited by 28
Srikantharajah, K., Quintela, R. M., Doerenkamp, K., Kampa, B. M., Musall, S., Rothermel, M., & Offenhäusser, A. (2021) · Scientific Reports · doi:10.1038/s41598-021-97940-x · Cited by 28
Biocompatibility of common implantable sensor materials in a tumor xenograft model
Gray, M., Meehan, J., Blair, E. O., Ward, C., Langdon, S. P., Morrison, L. R., Marland, J. R. K., Tsiamis, A., Kunkler, I. H., Murray, A., et al. (2018) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34254 · Cited by 25
Biological Considerations of Optical Interfaces for Neuromodulation
Hart, W. L., Kameneva, T., Wise, A. K., & Stoddart, P. R. (2019) · Advanced Optical Materials · doi:10.1002/adom.201900385 · Cited by 25
Trotier, A., Bagnoli, E., Walski, T., Evers, J., Pugliese, E., Lowery, M. M., Kilcoyne, M., FitzGerald, U., & Biggs, M. J. P. (2023) · Advanced Science · doi:10.1002/advs.202301352 · Cited by 28
Polymer SU-8-Based Microprobes for Neural Recording and Drug Delivery
Altuna, A., Berganzo, J., & Fernández, L. J. (2015) · Frontiers in Materials · doi:10.3389/fmats.2015.00047 · Cited by 25
Insertion mechanics of amorphous SiC ultra-micro scale neural probes
Geramifard, N., Dousti, B., Nguyen, C. K., Abbott, J., Cogan, S. F., & Varner, V. D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5bf4 · Cited by 24
Lee, J. Y., Khaing, Z. Z., Siegel, J. J., & Schmidt, C. E. (2015) · RSC Advances · doi:10.1039/c5ra03294f · Cited by 25
Lo, M.-C., Wang, S., Singh, S., Damodaran, V. B., Ahmed, I., Coffey, K. R., Barker, D., Saste, K., Kals, K., Kaplan, H. M., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9fad · Cited by 22
Development of a Polydimethylsiloxane‐Based Electrode Array for Electrocorticography
Lee, K. Y., Moon, H., Kim, B., Kang, Y. N., Jang, J. W., Choe, H. K., & Kim, S. (2020) · Advanced Materials Interfaces · doi:10.1002/admi.202001152 · Cited by 25
Electrode sharpness and insertion speed reduce tissue damage near high-density penetrating arrays
McNamara, I., Wellman, S. M., Li, L., Eles, J. R., Savya, S. P., Sohal, H. S., Angle, M. R., & Kozai, T. D. Y. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad36e1 · Cited by 24
Biomechanical Strain Analysis at the Interface of Brain and Nanowire Electrodes on a Neural Probe
Zhu, R., Huang, G. L., Yoon, H., Smith, C. S., & Varadan, V. K. (2011) · Journal of Nanotechnology in Engineering and Medicine · doi:10.1115/1.4005484 · Cited by 23
Hassler, C., Guy, J., Nietzschmann, M., Staiger, J. F., & Stieglitz, T. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090143 · Cited by 23
Gabran, S. R. I., Salam, M. T., Dian, J. A., El-Hayek, Y. H., Velázquez, J. L. P., Genov, R., Carlen, P. L., Salama, M. M. A., & Mansour, R. R. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2322077 · Cited by 23
Placing Sites on the Edge of Planar Silicon Microelectrodes Enhances Chronic Recording Functionality
Lee, H. C., Gaire, J., Roysam, B., & Otto, K. J. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2715811 · Cited by 23
Brain–Machine Interface Engineering
Sanchez, J. C., & Príncipe, J. C. (2007) · Synthesis lectures on biomedical engineering · doi:10.2200/s00053ed1v01y200710bme017 · Cited by 25
PEDOT/CNT Flexible MEAs Reveal New Insights into the Clock Gene's Role in Dopamine Dynamics
Wu, B., Castagnola, E., McClung, C. A., & Cui, X. T. (2024) · Advanced Science · doi:10.1002/advs.202308212 · Cited by 22
Advances in Penetrating Multichannel Microelectrodes Based on the Utah Array Platform
Leber, M., Körner, J., Reiche, C. F., Yin, M., Bhandari, R., Franklin, R. K., Negi, S., & Solzbacher, F. (2019) · Advances in experimental medicine and biology · doi:10.1007/978-981-13-2050-7_1 · Cited by 24
Flexible optoelectric neural interfaces
Ahmed, Z., Reddy, J. W., Malekoshoaraie, M. H., Hassanzade, V., Kimukin, Ï., Jain, V., & Chamanzar, M. (2021) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2021.11.001 · Cited by 25
Gregory, B. A., Thompson, C. H., Salatino, J. W., Railing, M. J., Zimmerman, A. F., Gupta, B., Williams, K., Beatty, J. A., Cox, C. L., & Purcell, E. K. (2023) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.07.027 · Cited by 24
Sankar, V., Sanchez, J. C., McCumiskey, E. J., Brown, N., Taylor, C. R., Ehlert, G. J., Sodano, H. A., & Nishida, T. (2013) · Frontiers in Neurology · doi:10.3389/fneur.2013.00124 · Cited by 21
Subbaroyan, J., & Kipke, D. R. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260517 · Cited by 21
Self-citationLi, Y., Deng, J., Zhou, J., & Li, X. (2016) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-016-5775-5 · Cited by 21
Hydrolytically Stable Thiol–ene Networks for Flexible Bioelectronics
Reit, R., Zamorano, D., Parker, S., Simon, D., Lund, B. R., Voit, W., & Ware, T. H. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b10593 · Cited by 20
Abed, A. A., Amatoury, J., & Khraiche, M. L. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.727715 · Cited by 20
Thin flexible arrays for long-term multi-electrode recordings in macaque primary visual cortex
Merken, L., Schelles, M., Ceyssens, F., Kraft, M. D., & Janssen, P. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac98e2 · Cited by 19
Emerging Penetrating Neural Electrodes: In Pursuit of Large Scale and Longevity
Luan, L., Yin, R., Zhu, H., & Xie, C. (2023) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-090622-050507 · Cited by 23
Kim, B., Gutierrez, C. A., & Meng, E. F. (2015) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2015.2420043 · Cited by 20
Materials and Structural Designs for Neural Interfaces
Kim, S., Kwon, Y. W., Seo, H., Chung, W. G., Kim, E., Park, W., Song, H., Lee, D. H., Lee, J., Lee, S., et al. (2023) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.2c01608 · Cited by 20
A Benchtop System to Assess Cortical Neural Interface Micromechanics
Das, R., Gandhi, D., Krishnan, S., Saggere, L., & Rousche, P. J. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897139 · Cited by 19
Metadata
- Authors
- Subbaroyan, J., Martin, D. C., & Kipke, D. R.
- Affiliations
- University of Michigan (US)
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2005-10-11
- Volume
- 2
- Issue
- 4
- Pages
- 103-113
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1982562840
- Cited by
- 368
- References
- 46
- Citations by year
- 2026: 13 · 2025: 20 · 2024: 14 · 2023: 17 · 2022: 15 · 2021: 21 · 2020: 27 · 2019: 19 · 2018: 29 · 2017: 15 · 2016: 24 · 2015: 23 · 2014: 20 · 2013: 24 · 2012: 14
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- Funders
- National Science Foundation (9986866)
- National Aeronautics and Space Administration
- National Institutes of Health
- National Nanotechnology Coordinating Office
- National Institute of Biomedical Imaging and Bioengineering (P41 EB-00 230-10)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- implantable microelectrodes, cerebral cortex, interfacial strain, silicon probes, tissue encapsulation, electrophysiological recording, neurostimulation
- MeSH terms
- Animals, Biomechanical Phenomena, Cerebral Cortex, Computer Simulation, Elasticity, Electrodes, Implanted, Humans, Microelectrodes, Models, Neurological, Motion, Physical Stimulation, Stress, Mechanical, Finite Element Analysis, Mechanotransduction, Cellular
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review