Cited by 57Neuroscience and Neural EngineeringUndergraduate Neuroscience Education and ResearchAnalog and Mixed-Signal Circuit Design

Long-term stability of intracortical recordings using perforated and arrayed Parylene sheath electrodes.

Hara, Seth A, Kim, Brian J, Kuo, Jonathan T W, Lee, Curtis D, Meng, Ellis, Pikov, Victor·2016·Journal of Neural Engineering

Abstract

OBJECTIVE: Acquisition of reliable and robust neural recordings with intracortical neural probes is a persistent challenge in the field of neuroprosthetics. We developed a multielectrode array technology to address chronic intracortical recording reliability and present in vivo recording results. APPROACH: The 2 × 2 Parylene sheath electrode array (PSEA) was microfabricated and constructed from only Parylene C and platinum. The probe includes a novel three-dimensional sheath structure, perforations, and bioactive coatings that improve tissue integration and manage immune response. Coatings were applied using a sequential dip-coating method that provided coverage over the entire probe surface and interior of the sheath structure. A sharp probe tip taper facilitated insertion with minimal trauma. Fabricated probes were subject to examination by optical and electron microscopy and electrochemical testing prior to implantation. MAIN RESULTS: 1 × 2 arrays were successfully fabricated on wafer and then packaged together to produce 2 × 2 arrays. Then, probes having electrode sites with adequate electrochemical properties were selected. A subset of arrays was treated with bioactive coatings to encourage neuronal growth and suppress inflammation and another subset of arrays was implanted in conjunction with a virally mediated expression of Caveolin-1. Arrays were attached to a custom-made insertion shuttle to facilitate precise insertion into the rat motor cortex. Stable electrophysiological recordings were obtained during the period of implantation up to 12 months. Immunohistochemical evaluation of cortical tissue around individual probes indicated a strong correlation between the electrophysiological performance of the probes and histologically observable proximity of neurons and dendritic sprouting. SIGNIFICANCE: The PSEA demonstrates the scalability of sheath electrode technology and provides higher electrode count and density to access a greater volume for recording. This study provided support for the importance of creating a supportive biological environment around the probes to promote the long-term electrophysiological performance of flexible probes in the cerebral cortex. In particular, we demonstrated beneficial effects of the Matrigel coating and the long-term expression of Caveolin-1. Furthermore, we provided support to an idea of using an artificial acellular tissue compartment as a way to counteract the walling-off effect of the astrocytic scar formation around the probes as a means of establishing a more intimate and stable neural interface.

Integrity signals

Registry

Crossref · 10.1088/1741-2560/13/6/066020

Cites

61 of 61 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Modification of the chemical composition of the surface of the electrodes by using different polymers and nanomaterials is a relatively simple way to control biological responses and improve long-term biotolerability of neural electrodes.

    “Another relatively simple way to control the biological responses and improve the long-term biotolerability of neural electrodes is the modification of the chemical composition of the surface of the electrodes by using different polymers and nanomaterials (Hara et al., 2016; Fernandez and Botella, 2017; Gulino et al., 2019).”
  • Many flexible PNS implants have shown promising performance in long-term in vivo tests.

    “Many of them have shown promising performance in long-term in vivo tests (Sohal et al. 2016; Caravaca et al. 2017; Hara et al. 2016; Wurth et al. 2017; Pothhof et al. 2016).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Hara, S. A., Kim, B. J., Kuo, J. T. W., Lee, C. D., Meng, E., & Pikov, V.
Affiliations
  • University of Southern California (US)
  • Huntington Medical Research Institutes (US)
Corresponding author
Meng, Ellis
Venue
Journal of Neural Engineering
Published
2016-11-07
Volume
13
Issue
6
Pages
066020
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2552587715
Cited by
57
References
61
Citations by year
2026: 2 · 2025: 6 · 2024: 8 · 2023: 9 · 2022: 4 · 2021: 8 · 2020: 4 · 2019: 4 · 2018: 7 · 2017: 5
FWCI
2.99
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Neural Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
Defense Advanced Research Projects Agency (N66001-11-1-4207)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Undergraduate Neuroscience Education and Research
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
Keywords
intracortical recording, microelectrode arrays, neuroprosthetics, bioactive coatings, caveolin-1, viral gene expression, neural interfaces, flexible neural probes, microfabrication, dendritic sprouting
MeSH terms
Electrocorticography, Animals, Axons, Cerebral Cortex, Dendrites, Electrodes, Implanted, Immunohistochemistry, Platinum, Polymers, Prosthesis Design, Xylenes, Coated Materials, Biocompatible, Cell Proliferation, Caveolin 1, Rats, Electrochemical Techniques, Neural Prostheses, Signal-To-Noise Ratio

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›