Electrochemical polymerization of conducting polymers in living neural tissue
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
A number of biomedical devices require extended electrical communication with surrounding tissue. Significant improvements in device performance would be achieved if it were possible to maintain communication with target cells despite the reactive, insulating scar tissue that forms at the device-tissue interface. Here, we report that the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) can be polymerized directly within living neural tissue resulting in an electrically conductive network that is integrated within the tissue. Nano and microscale PEDOT filaments extend out from electrode sites, presumably forming within extracellular spaces. The cloud of PEDOT filaments penetrates out into the tissue far enough that it should be possible to bypass fibrous scar tissue and contact surrounding healthy neurons. These electrically functional, diffuse conducting polymer networks grown directly within tissue signify a new paradigm for creating soft, low impedance implantable electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oxidative mechanisms in the toxicity of metal ions
Stohs, S. J., & Bagchi, D. (1995) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(94)00159-h · Cited by 4,219
Reactive Oxygen Species and the Central Nervous System
Halliwell, B. (1992) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1992.tb10990.x · Cited by 2,947
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Self-citationChronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Self-citationSubbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368
Self-citation
Cited by
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Conductive polymers: Towards a smart biomaterial for tissue engineering
Balint, R., Cassidy, N. J., & Cartmell, S. H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.015 · Cited by 1,777
Stretchable Conductive Polymers and Composites Based on PEDOT and PEDOT:PSS
Kayser, L. V., & Lipomi, D. J. (2019) · Advanced Materials · doi:10.1002/adma.201806133 · Cited by 1,186
“Green” electronics: biodegradable and biocompatible materials and devices for sustainable future
Irimia-Vladu, M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60235d · Cited by 1,044
Feig, V. R., Tran, H., Lee, M., & Bao, Z. (2018) · Nature Communications · doi:10.1038/s41467-018-05222-4 · Cited by 585
Organic Bioelectronics: Bridging the Signaling Gap between Biology and Technology
Simon, D. T., Gabrielsson, E. O., Tybrandt, K., & Berggren, M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00146 · Cited by 568
Green and biodegradable electronics
Irimia-Vladu, M., Głowacki, E. D., Voss, G., Bauer, S., & Sariciftci, N. S. (2012) · Materials Today · doi:10.1016/s1369-7021(12)70139-6 · Cited by 474
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“Polymerization of PEDOT around living cells has been reported in vitro (318) as well as in vivo (319) through living tissue.”
BackgroundHydrogen-bonds in molecular solids – from biological systems to organic electronics
Głowacki, E. D., Irimia-Vladu, M., Bauer, S., & Sariciftci, N. S. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20193g · Cited by 355
Electroactive polymers for tissue regeneration: Developments and perspectives
Ning, C., Zhou, Z., Tan, G., Zhu, Y., & Mao, C. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.01.001 · Cited by 346
Luo, S.-C., Mohamed Ali, E., Tansil, N. C., Yu, H.-H., Gao, S., Kantchev, E. A. B., & Ying, J. Y. (2008) · Langmuir · doi:10.1021/la800333g · Cited by 323
Review paper: Progress in the Field of Conducting Polymers for Tissue Engineering Applications
Bendrea, A.-D., Cianga, L., & Cianga, I. (2011) · Journal of Biomaterials Applications · doi:10.1177/0885328211402704 · Cited by 322
Toward a comparison of microelectrodes for acute and chronic recordings
Ward, M. P., Rajdev, P., Ellison, C., & Irazoqui, P. P. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.052 · Cited by 296
Ludwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/014001 · Cited by 283
Self-citationOrganic electrode coatings for next-generation neural interfaces
Aregueta-Robles, U. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 254
Application of intrinsically conducting polymers in flexible electronics
Ouyang, J. (2021) · SmartMat · doi:10.1002/smm2.1059 · Cited by 197
“The PEDOT chains form a conductive network, and this can decrease the impedance by 1–2 orders by magnitude.(149) FIGURE 16 (A) Schematic structure and (B) photo of a strain sensor with three layers.”
BackgroundWilks, S. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.007.2009 · Cited by 188
“Further, bioactive molecules can be incorporated into PEDOT fi lms (Abidian et al., 2006; Cui and Martin, 2003; Kim et al., 2007) and PEDOT can be polymerized in and around living neural tissue, signifying the possibility of a hybrid polymer-live cell electrode (Richardson-Burns et al., 2007a,b).”
Parylene-based flexible neural probes with PEDOT coated surface for brain stimulation and recording
Castagnola, V., Descamps, E., Lecestre, A., Dahan, L., Remaud, J., Nowak, L. G., & Bergaud, C. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.004 · Cited by 183
The Morphology of Poly(3,4-Ethylenedioxythiophene)
Martin, D. C., Wu, J., Shaw, C. M., King, Z., Spanninga, S. A., Richardson-Burns, S., Hendricks, J., & Yang, J. (2010) · Polymer Reviews · doi:10.1080/15583724.2010.495440 · Cited by 182
“A related technique was developed to electropolymerize PEDOT within living tissue such as the skin, peripheral nerve, muscle, and brain, a tissue in which it was found that the PEDOT could be extended out from the active electrode for several hundreds of micrometers 95 , 96 ( Figure 33 ).”
MethodSelf-citationSasaki, M., Karikkineth, B. C., Nagamine, K., Kaji, H., Torimitsu, K., & Nishizawa, M. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400209 · Cited by 169
Kolarcik, C. L., Catt, K., Rost, E., Albrecht, I. N., Bourbeau, D., Du, Z., Kozai, T. D. Y., Luo, X., Weber, D. J., & Tracy Cui, X. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016008 · Cited by 126
“, brain, heart, skeletal muscle) has been investigated for a variety of applications including vagal nerve stimulation, retinal and cochlear implants, spinal cord stimulation and deep brain stimulation [1].”
BackgroundNeural interfaces engineered via micro- and nanostructured coatings
Chen, N., Tian, L., Patil, A. C., Peng, S., Yang, I. H., Thakor, N. V., & Ramakrishna, S. (2017) · Nano Today · doi:10.1016/j.nantod.2017.04.007 · Cited by 74
Metadata
- Authors
- Richardson-Burns, S. M., Hendricks, J. L., & Martin, D. C.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2007-02-02
- Volume
- 4
- Issue
- 2
- Pages
- L6-L13
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2166204573
- Cited by
- 195
- References
- 9
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.