Optimal spacing of surface electrode arrays for brain–machine interface applications
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Brain-machine interfaces (BMIs) use signals recorded directly from the brain to control an external device, such as a computer cursor or a prosthetic limb. These control signals have been recorded from different levels of the brain, from field potentials at the scalp or cortical surface to single neuron action potentials. At present, the more invasive recordings have better signal quality, but also lower stability over time. Recently, subdural field potentials have been proposed as a stable, good quality source of control signals, with the potential for higher spatial and temporal bandwidth than EEG. Here we used finite element modeling in rats and humans and spatial spectral analysis in rats to compare the spatial resolution of signals recorded epidurally (outside the dura), with those recorded from subdural and scalp locations. Resolution of epidural and subdural signals was very similar in rats and somewhat less so in human models. Both were substantially better than signals recorded at the scalp. Resolution of epidural and subdural signals in humans was much more similar when the cerebrospinal fluid layer thickness was reduced. This suggests that the less invasive epidural recordings may yield signals of similar quality to subdural recordings, and hence may be more attractive as a source of control signals for BMIs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2020) · Electromagnetic Processes · doi:10.2307/j.ctv131bv37.5 · Cited by 21,966
Statistical pattern recognition: a review
Jain, A. K., Duin, P. W., & Mao, J. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824819 · Cited by 6,767 · cited 1×
“Moreover, adding too many electrodes could invoke the curse of dimensionality—given a fixed amount of input samples, increasing the dimension of the input space will eventually decrease the quality of classification [43].”
BackgroundGabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 2×
“Moreover, changes in skull conductivity within the ranges reported for cancellous and cortical bone [31] had little effect on subdural and epidural potentials, although they did affect scalp potentials.”
Background(1998) · Physics from Fisher Information · doi:10.1017/cbo9780511622670.006 · Cited by 4,018
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“single- and multi-unit action potentials (spikes) [3, 13, 14].”
The Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,599
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 6×
“Control signals for BMIs have been successfully derived from the scalp (electroencephalography; EEG) [1, 2, 6–8], the surface of the pia mater (subdural, electrocorticography; ECoG) [9–12] and from intracortical 1741-2560/10/026004+09$30.00 1 © 2010 IOP Publishing Ltd Printed in the UK single- and multi-unit action po…”
BackgroundMethodInfluentialDirect Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540 · cited 1×
“single- and multi-unit action potentials (spikes) [3, 13, 14].”
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512 · cited 1×
“Thus far, information rates from scalp- and spikecontrolled BMIs have been compared only indirectly, retrospectively, using widely different numbers of electrodes, species and behavioral tasks [2].”
BackgroundReal-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487 · cited 1×
“intracortical single- and multi-unit action potentials (spikes) [3,13,14].”
BackgroundSpatial filter selection for EEG-based communication
McFarland, D. J., McCane, L. M., David, S. V., & Wolpaw, J. R. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00022-2 · Cited by 936 · cited 1×
“Since referencing schemes can affect the properties of recorded signals, we also examined the effect on the spatial spectra of two commonly used methods: bipolar referencing, equivalent to the spatial difference of the signals, and common average referencing [39].”
MethodCurrent Practice of Clinical Electroencephalography.
(1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-92-4-582_3 · Cited by 732
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · cited 1×
“However, current intracortical arrays can record action potentials for only a limited time [15], typically a few years [16].”
BackgroundConsiderations of quasi-stationarity in electrophysiological systems
Plonsey, R., & Heppner, D. B. (1967) · The Bulletin of Mathematical Biophysics · doi:10.1007/bf02476917 · Cited by 619 · cited 1×
“Although these sources are time varying, the quasi-static approximation [26] states that for frequencies less than 1 kHz, brain impedances are predominantly resistive [27], and thus time-varying sources can be modeled electrostatically, i.”
BackgroundDirect control of paralysed muscles by cortical neurons
Moritz, C. T., Perlmutter, S. I., & Fetz, E. E. (2008) · Nature · doi:10.1038/nature07418 · Cited by 598 · cited 2×
“It is possible that increasing the density of subdural or epidural electrodes will enable BMIs to achieve more complex goals that require greater bandwidth and more degrees of freedom, such as restoring arm function with functional electrical stimulation [4, 5].”
BackgroundReview on solving the forward problem in EEG source analysis
Hallez, H., Vanrumste, B., Grech, R., Muscat, J., De Clercq, W., Vergult, A., D'Asseler, Y., Camilleri, K. P., Fabri, S. G., Van Huffel, S., et al. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-46 · Cited by 527
Current trends in Graz brain-computer interface (BCI) research
Pfurtscheller, G., Neuper, C., Guger, C., Harkam, W., Ramoser, H., Schlogl, A., Obermaier, B., & Pregenzer, M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847821 · Cited by 518 · cited 5×
“Control signals for BMIs have been successfully derived from the scalp (electroencephalography; EEG) [1, 2, 6–8], the surface of the pia mater (subdural, electrocorticography; ECoG) [9–12] and from intracortical 1741-2560/10/026004+09$30.00 1 © 2010 IOP Publishing Ltd Printed in the UK single- and multi-unit action po…”
MethodInfluentialTwo-dimensional movement control using electrocorticographic signals in humans
Schalk, G., Miller, K. J., Anderson, N. R., Wilson, J. A., Smyth, M. D., Ojemann, J. G., Moran, D. W., Wolpaw, J. R., & Leuthardt, E. C. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/008 · Cited by 482 · cited 6×
“We may, for example, be losing information by sampling ECoG with the standard 1 cm clinical electrode spacing.”
MethodInfluentialIn Vivo Measurement of Cortical Impedance Spectrum in Monkeys: Implications for Signal Propagation
Logothetis, N. K., Kayser, C., & Oeltermann, A. (2007) · Neuron · doi:10.1016/j.neuron.2007.07.027 · Cited by 453
Wolters, C. H., Anwander, A., Tricoche, X., Weinstein, D., Koch, M. A., & MacLeod, R. S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.10.014 · Cited by 452
Multichannel EEG-based brain-computer communication
Wolpaw, J. R., & McFarland, D. J. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90135-x · Cited by 449 · cited 5×
“Control signals for BMIs have been successfully derived from the scalp (electroencephalography; EEG) [1, 2, 6–8], the surface of the pia mater (subdural, electrocorticography; ECoG) [9–12] and from intracortical 1741-2560/10/026004+09$30.00 1 © 2010 IOP Publishing Ltd Printed in the UK single- and multi-unit action po…”
MethodInfluentialThe brain response interface: communication through visually-induced electrical brain responses
Sutter, E. E. (1992) · Journal of Microcomputer Applications · doi:10.1016/0745-7138(92)90045-7 · Cited by 417 · cited 1×
“One compared visual evoked potentials from occipital cortex to a template waveform [17] and the other detected threshold crossings of the signal recorded from a skull screw over motor”
BackgroundSpatial spectra of scalp EEG and EMG from awake humans
Freeman, W. J., Holmes, M. D., Burke, B. C., & Vanhatalo, S. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00045-2 · Cited by 370 · cited 1×
“It has also been used to analyze signals recorded at the scalp [41] and subdural levels in anesthetized [28] and awake [42] humans.”
MethodThree-Dimensional Head Model Simulation of Transcranial Magnetic Stimulation
Wagner, T. A., Zahn, M., Grodzinsky, A. J., & Pascual-Leone, A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827925 · Cited by 348 · cited 1×
“465 S/m, respectively (see Table 1), in accordance with the literature [31-35].”
Spatial spectral analysis of human electrocorticograms including the alpha and gamma bands
Freeman, W. J., Rogers, L. J., Holmes, M. D., & Silbergeld, D. L. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00160-0 · Cited by 323 · cited 5×
“The dipole was placed in layers II–III of the cortex, thought to be the origin of the field potential signals recorded outside the brain [28, 29].”
BackgroundMethodInfluentialThe Society for Neuroscience 1995 annual meeting.
Hu, R. J. (1996) · PubMed · Cited by 316
Current practice of clinical electroencephalography
Hynie, S. (1980) · Neuropharmacology · doi:10.1016/0028-3908(80)90127-6 · Cited by 296
The Biomedical Engineering Handbook: Second Edition.
Onaral, B. (1999) · Electrical Engineering Handbook · doi:10.1201/9781420049510.sec6 · Cited by 246
Electrocorticography-based brain computer Interface-the seattle experience
Leuthardt, E. C., Miller, K. J., Schalk, G., Rao, R. P. N., & Ojemann, J. G. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875536 · Cited by 245
Lai, Y., van Drongelen, W., Ding, L., Hecox, K. E., Towle, V. L., Frim, D. M., & He, B. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.08.017 · Cited by 215
Finite-element model of the human head: scalp potentials due to dipole sources
Yan, Y., Nunez, P. L., & Hart, R. T. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442317 · Cited by 208
Relation of olfactory EEG to behavior: Spatial analysis.
Freeman, W. J., & Baird, B. (1987) · Behavioral Neuroscience · doi:10.1037//0735-7044.101.3.393 · Cited by 201 · cited 3×
“We used both a cortical dipole computer model and spatial spectral analysis [20] of data recorded from rats to determine the optimal interelectrode spacing at each level.”
MethodMarin, G., Guerin, C., Baillet, S., Garnero, L., & Meunier, G. (1998) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1998)6:4<250::aid-hbm5>3.0.co;2-2 · Cited by 168
ECoG factors underlying multimodal control of a brain-computer interface
Wilson, J. A., Felton, E. A., Garell, P. C., Schalk, G., & Williams, J. C. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875570 · Cited by 163 · cited 1×
“This is considerably denser spacing than any surface arrays that have been used for online BMIs thus far—the closest subdural grid spacing reported was 5 mm [11].”
BackgroundDipole models for the EEG and MEG
Schimpf, P. H., Ramon, C., & Haueisen, J. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.995679 · Cited by 156
Manola, L., Roelofsen, B. H., Holsheimer, J., Marani, E., & Geelen, J. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345810 · Cited by 132
Toward a Direct Brain Interface Based on Human Subdural Recordings and Wavelet-Packet Analysis
Graimann, B., Huggins, J. E., Levine, S. P., & Pfurtscheller, G. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826671 · Cited by 120 · cited 1×
“electrocorticography; ECoG) [9–12] and from intracortical”
Fine spatiotemporal structure of phase in human intracranial EEG
Freeman, W. J., Holmes, M., West, G. A., & Vanhatalo, S. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.03.012 · Cited by 117 · cited 1×
“It has also been used to analyze signals recorded at the scalp [41] and subdural levels in anesthetized [28] and awake [42] humans.”
MethodUsing human extra-cortical local field potentials to control a switch
Kennedy, P., Andreasen, D., Ehirim, P., King, B., Kirby, T., Mao, H., & Moore, M. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/002 · Cited by 98 · cited 1×
“cortex when the subject moved his foot [18].”
BackgroundLeuthardt, E. C., Freudenberg, Z., Bundy, D., & Roland, J. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0980 · Cited by 92
Blakely, T., Miller, K. J., Rao, R. P. N., Holmes, M. D., & Ojemann, J. G. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4650328 · Cited by 89 · cited 1×
“However, offline decoding of phonemes performed with subdural electrodes spaced at 3 mm [44] and an offline study examining information about wrist flexion/extension movements from subdural microelectrodes at 1 mm [45] both provide some evidence to support the notion that information is present at a smaller spatial sc…”
BackgroundComputational modeling of epidural cortical stimulation
Wongsarnpigoon, A., & Grill, W. M. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/4/009 · Cited by 78 · cited 1×
“465 S m−1, respectively (see table 1), in accordance with the literature [31–35].”
ResultGoal selection versus process control in a brain–computer interface based on sensorimotor rhythms
Royer, A. S., & He, B. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/016005 · Cited by 58
Thévenet, M., Bertrand, O., Perrin, F., Dumont, T., & Pernier, J. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/a/017 · Cited by 54 · cited 1×
“Finite element (FE) methods have been used frequently to solve the forward problem in EEG analysis, that is, to compute the potential at the surface of the scalp that would result from a layer of current sources [21-25].”
MethodRouse, A. G., & Moran, D. W. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333180 · Cited by 50 · cited 1×
“A third group has shown some preliminary evidence that EFPs can be used for proportional cursor control [19].”
BackgroundUse of Intracortical Recordings to Control a Hand Neuroprosthesis
Pohlmeyer, E. A., Perreault, E. J., Slutzky, M. W., Kilgore, K. L., Kirsch, R. F., Taylor, D. M., & Miller, L. E. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369698 · Cited by 9 · cited 2×
“It is possible that increasing the density of subdural or epidural electrodes will enable BMIs to achieve more complex goals that require greater bandwidth and more degrees of freedom, such as restoring arm function with functional electrical stimulation [4, 5].”
BackgroundSelf-citationEEG/MEG forward simulation through h- and p-type finite elements
Pursiainen, S. (2008) · Journal of Physics Conference Series · doi:10.1088/1742-6596/124/1/012041 · Cited by 7 · cited 1×
“Finite element (FE) methods have been used frequently to solve the forward problem in EEG analysis, that is, to compute the potential at the surface of the scalp that would result from a layer of current sources [21-25].”
Method
Cited by
Brain-Computer Interfaces Using Electrocorticographic Signals
Schalk, G., & Leuthardt, E. C. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2172408 · Cited by 427
Brain–machine interfaces in neurorehabilitation of stroke
Soekadar, S. R., Birbaumer, N., Slutzky, M. W., & Cohen, L. G. (2015) · Neurobiology of Disease · doi:10.1016/j.nbd.2014.11.025 · Cited by 335
Self-citationDecoding spoken words using local field potentials recorded from the cortical surface
Kellis, S., Miller, K., Thomson, K., Brown, R., House, P., & Greger, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056007 · Cited by 235
“While optimal parameters of spacing and electrode count are the subject of recent and ongoing studies [56], our findings motivate continued investigation into using micro-ECoG for BCI applications.”
ResultAdvances in closed-loop deep brain stimulation devices
Parastarfeizabadi, M., & Kouzani, A. Z. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0295-1 · Cited by 232
“4 mm by placing the electrode on the epidural instead of subdural space [40, 41].”
BackgroundRecent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206
Metadata
- Authors
- Slutzky, M. W., Jordan, L. R., Krieg, T., Chen, M., Mogul, D. J., & Miller, L. E.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2010-03-02
- Volume
- 7
- Issue
- 2
- Pages
- 026004
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2080800494
- Cited by
- 161
- References
- 47
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.