Toward a hybrid brain–computer interface based on imagined movement and visual attention
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Brain-computer interface (BCI) systems do not work for all users. This article introduces a novel combination of tasks that could inspire BCI systems that are more accurate than conventional BCIs, especially for users who cannot attain accuracy adequate for effective communication. Subjects performed tasks typically used in two BCI approaches, namely event-related desynchronization (ERD) and steady state visual evoked potential (SSVEP), both individually and in a 'hybrid' condition that combines both tasks. Electroencephalographic (EEG) data were recorded across three conditions. Subjects imagined moving the left or right hand (ERD), focused on one of the two oscillating visual stimuli (SSVEP), and then simultaneously performed both tasks. Accuracy and subjective measures were assessed. Offline analyses suggested that half of the subjects did not produce brain patterns that could be accurately discriminated in response to at least one of the two tasks. If these subjects produced comparable EEG patterns when trying to use a BCI, these subjects would not be able to communicate effectively because the BCI would make too many errors. Results also showed that switching to a different task used in BCIs could improve accuracy in some of these users. Switching to a hybrid approach eliminated this problem completely, and subjects generally did not consider the hybrid condition more difficult. Results validate this hybrid approach and suggest that subjects who cannot use a BCI should consider switching to a different BCI approach, especially a hybrid BCI. Subjects proficient with both approaches might combine them to increase information throughput by improving accuracy, reducing selection time, and/or increasing the number of possible commands.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Self-citationThe ten-twenty electrode system of the international federation
Jasper, H. H. (1958) · Electroencephalography and Clinical Neurophysiology · Cited by 6,567
Henry, M. A. (1995) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1995.0108 · Cited by 3,416
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Floating search methods in feature selection
Pudil, P., Novovičová, J., & Kittler, J. (1994) · Pattern Recognition Letters · doi:10.1016/0167-8655(94)90127-9 · Cited by 3,098
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
An EEG-based brain-computer interface for cursor control
Wolpaw, J. R., McFarland, D. J., Neat, G. W., & Forneris, C. A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90040-b · Cited by 1,114
Toward Brain-Computer Interfacing
(2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.001.0001 · Cited by 785
Brain–computer interfaces: communication and restoration of movement in paralysis
Birbaumer, N., & Cohen, L. G. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.125633 · Cited by 754
(2009) · The MIT Press eBooks · doi:10.7551/mitpress/8029.001.0001 · Cited by 743
Neuper, C., Scherer, R., Reiner, M., & Pfurtscheller, G. (2005) · Cognitive Brain Research · doi:10.1016/j.cogbrainres.2005.08.014 · Cited by 721
Self-citationBrain-computer interfaces based on the steady-state visual-evoked response
Middendorf, M., McMillan, G., Calhoun, G., & Jones, K. S. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847819 · Cited by 685
How many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652 · cited 1×
“Demographic information might help identify the best BCI approach and parameters for each user [57, 58].”
BackgroundA P300-based brain–computer interface for people with amyotrophic lateral sclerosis
Nijboer, F., Sellers, E. W., Mellinger, J., Jordan, M. A., Matuz, T., Furdea, A., Halder, S., Mochty, U., Krusienski, D. J., Vaughan, T. M., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.034 · Cited by 633 · cited 2×
“All four BCI approaches have been validated with target users in field settings (e.g. [4–7, 9, 15–19]).”
BackgroundMethodPfurtscheller, G. (2010) · Frontiers in Neuroscience · doi:10.3389/fnpro.2010.00003 · Cited by 625
Self-citationA practical VEP-based brain-computer interface
Wang, Y., Wang, R., Gao, X., Hong, B., & Gao, S. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875576 · Cited by 617
Brain–Computer Communication: Motivation, Aim, and Impact of Exploring a Virtual Apartment
Leeb, R., Lee, F., Keinrath, C., Scherer, R., Bischof, H., & Pfurtscheller, G. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.906956 · Cited by 513
Self-citationKübler, A., & Birbaumer, N. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.06.019 · Cited by 441 · cited 1×
“We defined 70% accuracy as the threshold for acceptable performance [36, 37], and other thresholds could substantially affect results.”
BackgroundBrain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420
Self-citationAllison, B. Z., & Neuper, C. (2010) · Human-Computer Interaction Series · doi:10.1007/978-1-84996-272-8_3 · Cited by 350
Self-citationBrain-computer communication: Self-regulation of slow cortical potentials for verbal communication
Kübler, A., Neumann, N., Kaiser, J., Kotchoubey, B., Hinterberger, T., & Birbaumer, N. P. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.26621 · Cited by 350
BCI demographics: how many (and what kinds of) people can use an SSVEP BCI?
Allison, B., Luth, T., Valbuena, D., Teymourian, A., Volosyak, I., & Graser, A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039495 · Cited by 344 · cited 1×
“Demographic information might help identify the best BCI approach and parameters for each user [57, 58].”
BackgroundSelf-citationAn Asynchronously Controlled EEG-Based Virtual Keyboard: Improvement of the Spelling Rate
Scherer, R., Muller, G. R., Neuper, C., Graimann, B., & Pfurtscheller, G. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827062 · Cited by 340
Self-citationThe Berlin brain-computer Interface: accurate performance from first-session in BCI-naive subjects
Blankertz, B., Losch, F., Krauledat, M., Dornhege, G., Curio, G., & Muller, K.-R. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923152 · Cited by 338 · cited 2×
“Improved signal processing can also make BCIs work for most but not all users [21].”
BackgroundMethodTowards an independent brain–computer interface using steady state visual evoked potentials
Allison, B. Z., McFarland, D. J., Schalk, G., Zheng, S. D., Jackson, M. M., & Wolpaw, J. R. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.09.121 · Cited by 327
Self-citationNeuper, C., Müller, G. R., Kübler, A., Birbaumer, N., & Pfurtscheller, G. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00387-5 · Cited by 317
Self-citationA Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Brain-Computer Interfacing for Intelligent Systems
Nijholt, A., & Tan, D. (2008) · IEEE Intelligent Systems · doi:10.1109/mis.2008.41 · Cited by 279
Pfurtscheller, G., Solis-Escalante, T., Ortner, R., Linortner, P., & Muller-Putz, G. R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2040837 · Cited by 276
Self-citationRehabilitation with Brain-Computer Interface Systems
Pfurtscheller, G., Muller-Putz, G. R., Scherer, R., & Neuper, C. (2008) · Computer · doi:10.1109/mc.2008.432 · Cited by 222
Self-citationMotor imagery and EEG-based control of spelling devices and neuroprostheses
Neuper, C., Müller-Putz, G. R., Scherer, R., & Pfurtscheller, G. (2006) · Progress in Brain Research · doi:10.1016/s0079-6123(06)59025-9 · Cited by 208
Self-citationEmulation of computer mouse control with a noninvasive brain–computer interface
McFarland, D. J., Krusienski, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/001 · Cited by 202
Brunner, C., Naeem, M., Leeb, R., Graimann, B., & Pfurtscheller, G. (2007) · Pattern Recognition Letters · doi:10.1016/j.patrec.2007.01.002 · Cited by 187
Self-citationA multimodal brain-based feedback and communication system
Hinterberger, T., Neumann, N., Pham, M., K�bler, A., Grether, A., Hofmayer, N., Wilhelm, B., Flor, H., & Birbaumer, N. (2004) · Experimental Brain Research · doi:10.1007/s00221-003-1690-3 · Cited by 171
Online Control of a Brain-Computer Interface Using Phase Synchronization
Brunner, C., Scherer, R., Graimann, B., Supp, G., & Pfurtscheller, G. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.881775 · Cited by 168
Self-citation15 years of BCI research at graz university of technology: current projects
Pfurtscheller, G., Muller-Putz, G. R., Schlogl, A., Graimann, B., Scherer, R., Leeb, R., Brunner, C., Keinrath, C., Lee, F., Townsend, G., et al. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875528 · Cited by 164
Self-citationAn Introduction to Brain-Computer Interfacing
Kübler, A., & Müller, K.-R. (2007) · Toward Brain-Computer Interfacing · doi:10.7551/mitpress/7493.003.0003 · Cited by 161
Sellers, E. W., Kubler, A., & Donchin, E. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875580 · Cited by 160
A binary spelling interface with random errors
Perelmouter, J., & Birbaumer, N. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847824 · Cited by 124
Improved signal processing approaches in an offline simulation of a hybrid brain–computer interface
Brunner, C., Allison, B. Z., Krusienski, D. J., Kaiser, V., Müller-Putz, G., Pfurtscheller, G., & Neuper, C. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.02.002 · Cited by 122
Self-citationEnzinger, C., Ropele, S., Fazekas, F., Loitfelder, M., Gorani, F., Seifert‐Held, T., Reiter, G., Neuper, C., Pfurtscheller, G., & Müller-Putz, G. (2008) · Experimental Brain Research · doi:10.1007/s00221-008-1465-y · Cited by 111
Self-citationBrain-computer interfaces — the key for the conscious brain locked into a paralyzed body
Kübler, A., & Neumann, N. (2005) · Progress in brain research · doi:10.1016/s0079-6123(05)50035-9 · Cited by 98
Feature Selection and Blind Source Separation in an EEG-Based Brain-Computer Interface
Peterson, D. A., Knight, J. N., Kirby, M. J. L., Anderson, C. W., & Thaut, M. H. (2005) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/asp.2005.3128 · Cited by 87
Vaughan, T. M., & Wolpaw, J. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875649 · Cited by 78
Self-initiation of EEG-based brain–computer communication using the heart rate response
Scherer, R., Müller-Putz, G., & Pfurtscheller, G. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/l01 · Cited by 74
Self-citationMüller-Putz, G., Eder, E., Wriessnegger, S. C., & Pfurtscheller, G. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.09.024 · Cited by 64
Self-citationThe Third International Meeting on Brain-Computer Interface Technology: making a difference.
Vaughan, T. M., & Wolpaw, J. R. (2006) · PubMed · Cited by 63
A scanning protocol for a sensorimotor rhythm-based brain–computer interface
Friedrich, E. V. C., McFarland, D. J., Neuper, C., Vaughan, T. M., Brunner, P., & Wolpaw, J. R. (2008) · Biological Psychology · doi:10.1016/j.biopsycho.2008.08.004 · Cited by 62
Self-citationPfurtscheller, G., Flotzinger, D., Pregenzer, M., Wolpaw, J. R., & McFarland, D. J. (1995) · PubMed · Cited by 58
Self-citationTowards ambulatory brain-computer interfaces: a pilot study with P300 signals
Lotte, F., Fujisawa, J., Touyama, H., Ito, R., Hirose, M., & Lécuyer, A. (2009) · International Conference on Advances in Computer Entertainment Technology (ACE) · doi:10.1145/1690388.1690452 · Cited by 57
Uşaklı, A. B., Gürkan, S., Fabio Aloise, A., Vecchiato, G., & Babiloni, F. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333742 · Cited by 47
Classification of movement-related EEG in a memorized delay task experiment
Müller-Gerking, J., Pfurtscheller, G., & Flyvbjerg, H. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00345-x · Cited by 34
Self-citationThe TOBI Hybrid BCI – The Data Acquisition Module
Breitwieser, C., Kreilinger, A., Neuper, C., & Müller-Putz, G. (2010) · Cited by 10
Self-citation
Cited by
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Pfurtscheller, G. (2010) · Frontiers in Neuroscience · doi:10.3389/fnpro.2010.00003 · Cited by 625
Self-citationA Hybrid BCI System Combining P300 and SSVEP and Its Application to Wheelchair Control
Li, Y., Pan, J., Wang, F., & Yu, Z. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2270283 · Cited by 421
“demonstrated that by detecting MI and SSVEP simultaneously, classification accuracy can be improved, especially for BCI-blind subjects [19].”
BackgroundEEG-Based Brain-Controlled Mobile Robots: A Survey
Bi, L., Fan, X.-A., & Liu, Y. (2013) · IEEE Transactions on Human-Machine Systems · doi:10.1109/tsmcc.2012.2219046 · Cited by 386
Metadata
- Authors
- Allison, B. Z., Brunner, C., Kaiser, V, Müller-Putz, G. R., Neuper, C., & Pfurtscheller, G.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2010-03-23
- Volume
- 7
- Issue
- 2
- Pages
- 026007
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1989513763
- Cited by
- 291
- References
- 53
- FWCI
- 15.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.