Toward a hybrid brain–computer interface based on imagined movement and visual attention
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Brain-computer interface (BCI) systems do not work for all users. This article introduces a novel combination of tasks that could inspire BCI systems that are more accurate than conventional BCIs, especially for users who cannot attain accuracy adequate for effective communication. Subjects performed tasks typically used in two BCI approaches, namely event-related desynchronization (ERD) and steady state visual evoked potential (SSVEP), both individually and in a 'hybrid' condition that combines both tasks. Electroencephalographic (EEG) data were recorded across three conditions. Subjects imagined moving the left or right hand (ERD), focused on one of the two oscillating visual stimuli (SSVEP), and then simultaneously performed both tasks. Accuracy and subjective measures were assessed. Offline analyses suggested that half of the subjects did not produce brain patterns that could be accurately discriminated in response to at least one of the two tasks. If these subjects produced comparable EEG patterns when trying to use a BCI, these subjects would not be able to communicate effectively because the BCI would make too many errors. Results also showed that switching to a different task used in BCIs could improve accuracy in some of these users. Switching to a hybrid approach eliminated this problem completely, and subjects generally did not consider the hybrid condition more difficult. Results validate this hybrid approach and suggest that subjects who cannot use a BCI should consider switching to a different BCI approach, especially a hybrid BCI. Subjects proficient with both approaches might combine them to increase information throughput by improving accuracy, reducing selection time, and/or increasing the number of possible commands.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Self-citationThe ten-twenty electrode system of the international federation
Jasper, H. H. (1958) · Electroencephalography and Clinical Neurophysiology · Cited by 6,567
Henry, M. A. (1995) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1995.0108 · Cited by 3,416
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Floating search methods in feature selection
Pudil, P., Novovičová, J., & Kittler, J. (1994) · Pattern Recognition Letters · doi:10.1016/0167-8655(94)90127-9 · Cited by 3,098
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
An EEG-based brain-computer interface for cursor control
Wolpaw, J. R., McFarland, D. J., Neat, G. W., & Forneris, C. A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90040-b · Cited by 1,114
Toward Brain-Computer Interfacing
(2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.001.0001 · Cited by 785
Brain–computer interfaces: communication and restoration of movement in paralysis
Birbaumer, N., & Cohen, L. G. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.125633 · Cited by 754
(2009) · The MIT Press eBooks · doi:10.7551/mitpress/8029.001.0001 · Cited by 743
Cited by
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Pfurtscheller, G. (2010) · Frontiers in Neuroscience · doi:10.3389/fnpro.2010.00003 · Cited by 625
Self-citationA Hybrid BCI System Combining P300 and SSVEP and Its Application to Wheelchair Control
Li, Y., Pan, J., Wang, F., & Yu, Z. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2270283 · Cited by 421
“demonstrated that by detecting MI and SSVEP simultaneously, classification accuracy can be improved, especially for BCI-blind subjects [19].”
BackgroundEEG-Based Brain-Controlled Mobile Robots: A Survey
Bi, L., Fan, X.-A., & Liu, Y. (2013) · IEEE Transactions on Human-Machine Systems · doi:10.1109/tsmcc.2012.2219046 · Cited by 386
Progress in Brain Computer Interface: Challenges and Opportunities
Saha, S., Mamun, K. A., Ahmed, K., Mostafa, R., Naik, G. R., Darvishi, S., Khandoker, A. H., & Baumert, M. (2021) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2021.578875 · Cited by 365
P300 brain computer interface: current challenges and emerging trends
Fazel-Rezai, R., Allison, B. Z., Guger, C., Sellers, E. W., Kleih, S. C., & Kübler, A. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00014 · Cited by 359
Self-citationAllison, B. Z., & Neuper, C. (2010) · Human-Computer Interaction Series · doi:10.1007/978-1-84996-272-8_3 · Cited by 350
Self-citationBCI demographics: how many (and what kinds of) people can use an SSVEP BCI?
Allison, B., Luth, T., Valbuena, D., Teymourian, A., Volosyak, I., & Graser, A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039495 · Cited by 344
Self-citationPerformance variation in motor imagery brain–computer interface: A brief review
Ahn, M., & Jun, S. C. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.01.033 · Cited by 316
Brain–Computer Interfaces: A Gentle Introduction
Graimann, B., Allison, B., & Pfurtscheller, G. (2009) · The Frontiers Collection · doi:10.1007/978-3-642-02091-9_1 · Cited by 298
Self-citationAn EEG-Based BCI System for 2-D Cursor Control by Combining Mu/Beta Rhythm and P300 Potential
Li, Y., Long, J., Yu, T., Yu, Z., Wang, C., Zhang, H., & Guan, C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2055564 · Cited by 298
Long, J., Li, Y., Wang, H., Yu, T., Pan, J., & Li, F. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2197221 · Cited by 293
An SSVEP BCI to Control a Hand Orthosis for Persons With Tetraplegia
Ortner, R., Allison, B. Z., Korisek, G., Gaggl, H., & Pfurtscheller, G. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2076364 · Cited by 281
Self-citationPfurtscheller, G., Solis-Escalante, T., Ortner, R., Linortner, P., & Muller-Putz, G. R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2040837 · Cited by 276
Self-citationHong, K.-S., & Khan, M. J. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00035 · Cited by 267
EEG-Based Brain-Computer Interfaces: A Thorough Literature Survey
Hwang, H.-J., Kim, S., Choi, S., & Im, C.-H. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2013.780869 · Cited by 257
“Other BCI articles used more than two kinds of features: Some of them combined two feature types into one feature set in order to enhance the performance or efficiency of the BCI system (Allison et al., 2010; Brunner et al., 2010; Li, Long, et al., 2010; Pfurtscheller et al., 2010; Rebsamen et al., 2010; Wei, Wang, Ga…”
BackgroundMethodA Dynamically Optimized SSVEP Brain–Computer Interface (BCI) Speller
Yin, E., Zhou, Z., Jiang, J., Yu, Y., & Hu, D. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2320948 · Cited by 254
Khan, M. A., Das, R., Iversen, H. K., & Puthusserypady, S. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103843 · Cited by 250
“, the reorganizational processes in the brain) [39-41].”
BackgroundNoninvasive Brain-Computer Interfaces Based on Sensorimotor Rhythms
He, B., Baxter, B., Edelman, B. J., Cline, C. C., & Ye, W. W. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2407272 · Cited by 233
“User-centered BCI training approaches have been attempted recently [160], [161] focusing on the brain component of BCIs by emphasizing early focus on the users, tasks, and environment with the goal of improving the performance of BCIs.”
A novel hybrid BCI speller based on the incorporation of SSVEP into the P300 paradigm
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026012 · Cited by 225
“For example, Allison et al developed a hybrid BCI based on event-related desynchronization (ERD) and steady-state visual evoked potential (SSVEP) [21, 23].”
MethodHramov, A. E., Maksimenko, V. A., & Pisarchik, A. N. (2021) · Physics Reports · doi:10.1016/j.physrep.2021.03.002 · Cited by 213
Consumer grade EEG devices: are they usable for control tasks?
Maskeliunas, R., Damasevicius, R., Martisius, I., & Vasiljevas, M. (2016) · PeerJ · doi:10.7717/peerj.1746 · Cited by 210
High Theta and Low Alpha Powers May Be Indicative of BCI-Illiteracy in Motor Imagery
Ahn, M., Cho, H., Ahn, S., & Jun, S. C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0080886 · Cited by 209
“On the other hand, hybrid approaches may be introduced, since these methods facilitate the use of information from more than two paradigms [46–48].”
BackgroundA Review of Hybrid Brain-Computer Interface Systems
Amiri, S., Fazel-Rezai, R., & Asadpour, V. (2013) · Advances in Human-Computer Interaction · doi:10.1155/2013/187024 · Cited by 209
“Comparing the results of this experience with the previous one [15], improvement was seen in the ERD results as the performance of the task had been changed (right hand versus left hand movement imagination in the previous study and both hand versus both feet movement imagination in this study).”
MethodResultInfluentialMa, J., Zhang, Y., Cichocki, A., & Matsuno, F. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369483 · Cited by 209
“[17] [30] [31] [32] [33] ! !”
An Asynchronous P300 BCI With SSVEP-Based Control State Detection
Panicker, R. C., Puthusserypady, S., & Sun, Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2116018 · Cited by 203
McMullen, D. P., Hotson, G., Katyal, K. D., Wester, B. A., Fifer, M. S., McGee, T. G., Harris, A., Johannes, M. S., Vogelstein, R. J., Ravitz, A. D., et al. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2294685 · Cited by 188
“, combining electroencephalography (EEG)-based SSVEP and P300 potentials for BMI) or from physiological signals such as electromyography (EMG) or electrooculography (EOG) [14]–[18].”
BackgroundEEG-based BCI and video games: a progress report
Kerous, B., Skola, F., & Liarokapis, F. (2018) · Virtual Reality · doi:10.1007/s10055-017-0328-x · Cited by 179
“Hybrid BCI is defined in Allison et al. (2010) as pure hybrid BCIs that combine two or more BCI paradigms, physiological hybrid BCIs, which combine a BCI with another physiological signal, or mixed hybrid BCIs, which combine a BCI with non-physiological input (see Fig.”
BackgroundA Speedy Hybrid BCI Spelling Approach Combining P300 and SSVEP
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2281976 · Cited by 167
“Additional details of these hybrid stimulus mechanisms were provided in our previous study [23].”
Li, Y., Pan, J., Long, J., Yu, T., Wang, F., Yu, Z., & Wu, W. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2469106 · Cited by 117
“Multimodal BCIs combining MI and SSVEPs have also been reported [25], [26] and used in various applications, such as for controlling a cursor [26] or an orthosis [27].”
Method
Metadata
- Authors
- Allison, B. Z., Brunner, C., Kaiser, V, Müller-Putz, G. R., Neuper, C., & Pfurtscheller, G.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2010-03-23
- Volume
- 7
- Issue
- 2
- Pages
- 026007
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1989513763
- Cited by
- 291
- References
- 53
- FWCI
- 15.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.