Evaluation of stimulus parameters and electrode geometry for an effective suprachoroidal retinal prosthesis
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Several approaches have been proposed for placement of retinal prostheses: epiretinal, subretinal and suprachoroidal. We aimed to systematically evaluate the effectiveness of varying a range of stimulus parameters and electrode geometry for a suprachoroidal electrode array, using cortical evoked responses to monopolar electrical stimulation in cats. Our results indicate that charge thresholds were not dependent on electrode size, pulse widths or position of the return electrode tested, but were dependent on the number of sites stimulated in parallel. Further, we found that the combination of monopolar stimulation with large diameter electrodes, wide pulse widths and parallel stimulation minimized the voltage requirements for stimulation. These results provide useful insights for the design specifications of a low voltage suprachoroidal stimulator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marr, D., & Hildreth, E. (1980) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1980.0020 · Cited by 6,510
Receptive fields of single neurones in the cat's striate cortex
Hubel, D. H., & Wiesel, T. N. (1959) · The Journal of Physiology · doi:10.1113/jphysiol.1959.sp006308 · Cited by 4,653
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · cited 1×
“In addition, Rizzo et al (2003) using multiple current sources were able to simultaneously stimulate groups of electrode sites in human patients which were perceived as distinct patterns.”
BackgroundFocal activation of the feline retina via a suprachoroidal electrode array
Wong, Y. T., Chen, S. C., Seo, J. M., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.018 · Cited by 109 · cited 7×
“…et al 2006; approximately 10 ms, Elfar et al 2009), suprachoroidal stimulation in cats and rabbits using similar arrays (9 ± 1 ms, Sakaguchi et al 2004; 10.5 ± 0.6 ms, Wong et al 2009; 16 ± 2 ms, Nakauchi et al 2005), and extraocular stimulation in cats (approximately 8 ms, Chowdhury et al 2005).”
BackgroundMethodResultSelf-citation
Cited by
Fujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Endo, T., Hirota, M., Morimoto, T., Nishida, K., Kishima, H., Terasawa, Y., et al. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-20367 · Cited by 101
Artificial vision through neuronal stimulation
Fernandes, R. A. B., Diniz, B., Ribeiro, R., & Humayun, M. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.01.063 · Cited by 90
Factors Affecting Perceptual Thresholds in a Suprachoroidal Retinal Prosthesis
Shivdasani, M. N., Sinclair, N. C., Dimitrov, P. N., Varsamidis, M., Ayton, L. N., Luu, C. D., Perera, T., McDermott, H. J., & Blamey, P. J. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14396 · Cited by 78
Self-citationVirtual electrodes by current steering in retinal prostheses
Dumm, G., Fallon, J. B., Williams, C. E., & Shivdasani, M. N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-15391 · Cited by 63
Self-citationHeating of the eye by a retinal prosthesis: modeling, cadaver and in vivo study
Opie, N. L., Burkitt, A. N., Meffin, H., & Grayden, D. B. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2171961 · Cited by 59
“To imitate materials and dimensions of Bionic Vision Australia’s suprachoroidal implants and the epiretinally implanted stimulating chips [10], a single, multifunction, imitation prosthesis was designed [5], [17].”
Method
Metadata
- Authors
- Shivdasani, M. N., Luu, C. D., Cicione, R., Fallon, J. B., Allen, P. J., Leuenberger, J., Suaning, G. J., Lovell, N. H., Shepherd, R. K., & Williams, C. E.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2010-05-18
- Volume
- 7
- Issue
- 3
- Pages
- 036008
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2016368254
- Cited by
- 86
- References
- 4
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of stimulus parameters and electrode geometry for an effective suprachoroidal retinal prosthesis. https://app.cochat.ai/papers/10.1088/1741-2560/7/3/036008
- The paper
- Shivdasani, M. N., Luu, C. D., Cicione, R., Fallon, J. B., Allen, P. J., Leuenberger, J., Suaning, G. J., Lovell, N. H., Shepherd, R. K., & Williams, C. E. (2010). Evaluation of stimulus parameters and electrode geometry for an effective suprachoroidal retinal prosthesis. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/7/3/036008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.