Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodes
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
We investigated using poly(3,4-ethylenedioxythiophene) (PEDOT) to lower the impedance of small, gold recording electrodes with initial impedances outside of the effective recording range. Smaller electrode sites enable more densely packed arrays, increasing the number of input and output channels to and from the brain. Moreover, smaller electrode sizes promote smaller probe designs; decreasing the dimensions of the implanted probe has been demonstrated to decrease the inherent immune response, a known contributor to the failure of long-term implants. As expected, chronically implanted control electrodes were unable to record well-isolated unit activity, primarily as a result of a dramatically increased noise floor. Conversely, electrodes coated with PEDOT consistently recorded high-quality neural activity, and exhibited a much lower noise floor than controls. These results demonstrate that PEDOT coatings enable electrode designs 15 µm in diameter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While the smaller electrode sites necessitated by finer-scale geometries have the drawback of increased impedance, inclusion of conductive polymers mitigates this effect and allows improved signal detection.71,72”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [72]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geometric Control of Cell Life and Death
Chen, C. S., Mrksich, M., Huang, S., Whitesides, G. M., & Ingber, D. E. (1997) · Science · doi:10.1126/science.276.5317.1425 · Cited by 4,657
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
A review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x/9/4/001 · Cited by 1,370 · cited 1×
“The remaining eight sites on each probe were left uncoated as controls for comparison.”
MethodHarris, K. D., Henze, D. A., Csicsvari, J., Hirase, H., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.401 · Cited by 1,151
Specific proteins mediate enhanced osteoblast adhesion on nanophase ceramics
Webster, T. J., Ergun, C., Doremus, R. H., Siegel, R. W., & Bizios, R. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20000905)51:3<299::aid-jbm2>3.0.co;2-8 · Cited by 995
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942 · cited 1×
“Site and shank separations were sufficient (100 μm or greater) to limit the probability of an individual neuron being recorded from multiple sites [23].”
BackgroundBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721 · cited 1×
“(Some figures in this article are in colour only in the electronic version)”
BackgroundLudwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · cited 10×
“After initial principal component analysis and fuzzy Cmeans clustering [12], waveforms with a cluster membership index of greater than 0.”
BackgroundMethodResultInfluentialSelf-citation
Research works printed but not linked: 3
- Schmidt E Humphrey DR Neurophysiological techniques 1990 2 1 64 Humana Press
- Vetter RJ Williams JC Hetke JF Nunamaker EA Kipke DR Spike recording performance of implanted chronic silicon-substrate microelectrode arrays in cerebral cortex. IEEE Transactions on Neural Systems and Rehabilitation Engineering 2004 52
- Purcell EK Thompson DE Ludwig KA Kipke DR Flavopiridol reduces the impedance of neural prostheses in vivo without affecting recording quality. J Neurosci Methods 2009 doi:S0165-0270(09)00344-6 [pii] 10.1016/j.jneumeth.2009.06.026 19560490 · DOI · Paper page
Cited by
Items 201–297 of 297
Zhu, Y., Yang, Y., Ni, G., Li, S., Liu, W., Gao, Z., Zhang, X., Zhang, Q., Wang, C., & Zhou, J. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1284927 · Cited by 6
Pre-saccadic Neural Enhancements in Marmoset Area MT
Coop, S. H., Yates, J. L., & Mitchell, J. F. (2023) · Journal of Neuroscience · doi:10.1523/jneurosci.2034-22.2023 · Cited by 6
Fabrication of Multielectrode Arrays for Neurobiology Applications
Malerba, M., Amin, H., Angotzi, G. N., Maccione, A., & Berdondini, L. (2018) · Methods in molecular biology · doi:10.1007/978-1-4939-7792-5_12 · Cited by 8
Cai, D., Yuan, Q., Sun, P., Liu, H., Xiong, Q., Liang, T., Niu, L., Chen, W., Jin, Y., Zhang, S., et al. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117999 · Cited by 5
Multifunctional Implantable Device for Simultaneous Optical and Electrophysiological Measurements
Naganuma, K., Ohta, Y., Murakami, T. E., Okada, R., Guinto, M. C., Takehara, H., Haruta, M., Tashiro, H., Sasagawa, K., Sunaga, Y., et al. (2022) · Sensors and Materials · doi:10.18494/sam3710 · Cited by 5
Zhu, Y., Lin, H., Zhang, S., Pan, Q., Qian, S., Zhang, S., Zhang, Y., Luo, S., Yu, H., & Zhu, B. (2022) · Colloids and Interface Science Communications · doi:10.1016/j.colcom.2022.100656 · Cited by 5
Rejuvenating silicon probes for acute neurophysiology
Shoup, A. M., Porwal, N., Fakharian, M. A., Hage, P., Orozco, S. P., & Shadmehr, R. (2024) · Journal of Neurophysiology · doi:10.1152/jn.00121.2024 · Cited by 5
Frost, C. M., Cederna, P. S., Martin, D. C., Shim, B. S., & Urbanchek, M. G. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943618 · Cited by 8
Synthesis of encapsulated ZnO nanowires provide low impedance alternatives for microelectrodes
Maddah, M., Unsworth, C. P., Gouws, G. J., & Plank, N. O. V. (2022) · PLoS ONE · doi:10.1371/journal.pone.0270164 · Cited by 6
Design and Microfabrication Considerations for Reliable Flexible Intracortical Implants
Sohal, H. S., Vassilevski, K., Jackson, A., Baker, S. N., & O’Neill, A. (2016) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2016.00005 · Cited by 4
“A further 30 recording sites had impedances above 3 MΩ, and were not considered as viable probes for use for chronic implantation [34].”
BackgroundAbrahamsson, T., Ek, F., Cornuéjols, R., Byun, D., Savvakis, M., Bruschi, C., Sahalianov, I. Y., Miglbauer, E., Musumeci, C., Donahue, M. J., et al. (2025) · Angewandte Chemie · doi:10.1002/ange.202517897 · Cited by 4
Haghshenas, M., Ghazali, M., Jannesari, M., Dini, G., Saki, N., Asgarloo, S., & Asl, M. A. (2026) · Results in Surfaces and Interfaces · doi:10.1016/j.rsurfi.2026.100747 · Cited by 5
Averbeck, S. R., Garg, R., Dong, R., Hurwitz, D., Apollo, N. V., Beauchamp, M. S., & Vitale, F. (2026) · Small · doi:10.1002/smll.202514955 · Cited by 5
Shang, S., Xu, Y., Jin, M., Ni, C., Jiang, H., Wang, X., Wang, X., Cheng, Y., Wang, M., Zhang, S., et al. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136891 · Cited by 4
Sensors: Chemically Modified Electrodes
Morrin, A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-409547-2.14546-9 · Cited by 4
Low-cost silicon neural probe: fabrication, electrochemical characterization and in vivo validation
Rodrigues, J. A., Pimenta, S., Pereira, J. P., Gomes, N., Souto, M. R., Fernandes, H. C., Caetano, I., Soares‐Cunha, C., Oliveira, J. F., Ribeiro, J. F., et al. (2020) · Microsystem Technologies · doi:10.1007/s00542-020-04898-3 · Cited by 4
Central nervous system responses to biomaterials
Tsintou, M., Wróbel, P. P., & Dalamagkas, K. (2020) · Elsevier eBooks · doi:10.1016/b978-0-08-102967-1.00023-2 · Cited by 4
Wang, M., & Guo, L. (2020) · Springer eBooks · doi:10.1007/978-3-030-41854-0_4 · Cited by 4
Recent strategies for neural dynamics observation at a larger scale and wider scope
Lee, C. H., Park, Y. K., & Lee, K. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115638 · Cited by 4
Freeze Drying Improves the Shelf-Life of Conductive Polymer Modified Neural Electrodes
Mandal, H. S., Cliff, R. O., & Pancrazio, J. J. (2015) · Bioengineering · doi:10.3390/bioengineering2030176 · Cited by 4
Electrophysiology of Laminar Cortical Activity in the Common Marmoset
Bucklaew, A., Coop, S. H., & Mitchell, J. F. (2023) · Journal of Visualized Experiments · doi:10.3791/65397 · Cited by 3
Liu, Y., Jia, Q., Miao, J., Jiang, L., Shan, J., Wang, Y., Lv, S., Li, Q., Liu, Y., Jiao, P., et al. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117973 · Cited by 3
Radiolytic synthesis of rGO–PEDOT nanohybrids with enhanced functional properties
Zeid, S. A., Hu, L., Ghasemi, R., Gervais, M., Randhawa, J. K., Siril, P. F., & Rémita, S. (2025) · Materials Chemistry Frontiers · doi:10.1039/d5qm00775e · Cited by 3
Impact of Ethylene Oxide Sterilization on PEDOT:PSS Electrophysiology Electrodes
Maziz, A., Cointe, C., Reig, B., & Bergaud, C. (2026) · Sensors · doi:10.3390/s26030877 · Cited by 3
“Among these, CP nanostructures, and in particular poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS) [15–18], represent one of the most impactful advancements.”
Kim, G., Lee, S., Eun, J., Chou, N., & Shin, H. (2026) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.5c00952 · Cited by 3
Supracortical Microstimulation: Advances in Microelectrode Design and In Vivo Validation
Schmitz, C. M., Smith, J. E., Rachinskiy, I., Pesaran, B., Vitale, F., Sommer, M. A., & Viventi, J. (2025) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-103023-072855 · Cited by 3
Neurointerfaces: Review and development
Rechkunov, S. N., Prinz, A. V., Seleznev, V. A., Golod, S. V., Soots, R. A., Ivanov, A. I., Ratushnyak, A. S., & Prinz, V. Y. (2015) · Russian Journal of Genetics Applied Research · doi:10.1134/s2079059715060143 · Cited by 3
“On the other hand, distortions of the vol ume distribution of the potential caused by the equi potential surface of the electrodes can become signifi cant with decreasing spacing between the electrodes.”
BackgroundBelle, A. M., Enright, H. A., Mukerjee, E. V., Soscia, D. A., Osburn, J. J., Kuhn, E. A., Kulp, K. S., Wheeler, E. K., & Tolosa, V. (2017) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2017.7985919 · Cited by 3
“To increase the sensitivity of these electrodes to H 2 O 2 , three different materials were tested for their effectiveness as H 2 O 2 sensors: iridium oxide [7], poly(3,4-ethylenedioxythiophene) (PEDOT) [8] and electrodeposited Pt thin film.”
Polymers/PEDOT Derivatives for Bioelectronics
Donahue, M. J., Proctor, C. M., & Strakosas, X. (2020) · Royal Society of Chemistry eBooks · doi:10.1039/9781788019743-00488 · Cited by 3
What Do ECoG Recordings Tell Us About Intracortical Action Potentials?
Bockhorst, T., Engel, A. K., & Galindo-Leon, E. E. (2023) · Studies in neuroscience, psychology and behavioral economics · doi:10.1007/978-3-031-20910-9_18 · Cited by 3
A machine learning approach for real-time cortical state estimation
Weiss, D. A., Borsa, A. M., Pala, A., Sederberg, A., & Stanley, G. B. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad1f7b · Cited by 4
“All silicon probes were electrochemically plated with a poly(3,4-ethylenedioxythiophene) polymer [34,35] using a NanoZ device (White Matter) to achieve 1 kHz impedance values between 0.”
MethodUltrasonically enabled neural probes with co-located electrical and mechanical transduction
Chen, P., Clark, C. G., Schaffer, C. B., Gilmour, R. F., & Lal, A. (2012) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2012.0086 · Cited by 3
“Conductive polymers can decrease the initial impedance of electrodes, and also serve to reduce the required electrode size in order to record from a given area [6].”
BackgroundLatif, T., Gong, F., Dickey, M. D., Sichitiu, M. L., & Bozkurt, A. Y. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591152 · Cited by 3
Nanoelectronics for Neuroscience
Rastogi, S. K., & Cohen‐Karni, T. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99893-3 · Cited by 3
Electrochemical Roughening and Carbon Nanotube Coating of Tetrodes for Chronic Single-Unit RecordingPreprint
Xia, Z., Arias-Gil, G., Deckert, M., Vollmer, M., Curran, A. W., Herrera-Molina, R., Brosch, M., Krug, K., Schmidt, B., Ohl, F. W., et al. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/738245 · Cited by 4
Impedance scaling for gold and platinum microelectrodesPreprint
Fan, B., Wolfrum, B. L., & Robinson, J. T. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.03.09.434678 · Cited by 3
Myomatrix arrays for high-definition muscle recordingPreprint
Chung, B., Zia, M., Thomas, K. A., Michaels, J. A., Jacob, A., Pack, A. R., Williams, M., Nagapudi, K., Teng, L. H., Arrambide, E., et al. (2023) · eLife · doi:10.7554/elife.88551.1 · Cited by 6
Itawi, A., Zribi, B., Sidambaram, P., Tran, T. H., Tourrel, G., Torres, R., Ghenna, S., Grondel, S., Nguyen, Y., Plesse, C., et al. (2026) · Sensors and Actuators Reports · doi:10.1016/j.snr.2026.100447 · Cited by 2
Ebrahimi, S., Rostami, S., Petrossian, G., Quenneville, E., Courchesne, N. D., Moraes, C., & Cicoira, F. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c03097 · Cited by 2
Stajković, N., Manukanc, A., Trille, M., Steinkühler, J., Criscuolo, V., & Santoro, F. (2026) · Materials Horizons · doi:10.1039/d6mh00280c · Cited by 2
Flexible, biocompatible, highly scalable, high charge density 3D Microelectrode arrays
Kumar, G. D. V. S., Singh, S. G., & Vanjari, S. R. K. (2016) · IEEE International Conference on Emerging Electronics (ICEE) · doi:10.1109/icemelec.2016.8074612 · Cited by 2
Shen, X., Zhao, Y., Li, Q., & Chen, T. (2020) · AIP Advances · doi:10.1063/5.0003595 · Cited by 2
Design of Electrodes for Efficient and Selective Electrical Stimulation of Nervous Tissue
Howell, B. L. (2015) · DukeSpace (Duke University) · Cited by 3
Park, S., Kim, M. S., Lee, H., Lee, J., Chou, N., & Shin, H. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.117084 · Cited by 1
Hu, Y., Zhang, B., Hu, Z., Liu, X., Li, X., & Dai, J. (2025) · Sensors · doi:10.3390/s25247552 · Cited by 1
Mekki, Y. M., Park, J., Alzaareer, Z., Hussain, Z., Gulzar, A., Elzouki, A. Y. A., Güemes, A., & Zughaier, S. M. (2026) · Journal of Diabetes & Metabolic Disorders · doi:10.1007/s40200-026-01876-w · Cited by 1
“…coating the surface with materials such as conductive polymers like PEDOT ((Poly(3,4-ethylenedioxythiophene)) and PEDOT: PSS (Poly(3,4-ethylenedioxythiophene) polystyrene sulfonate), also reduces the electrical impedance, resulting in a high SNR despite the use of small electrodes [152–154].”
Li, M., Ly, C. M., Wen, J., Rustogi, P., & Meng, E. F. (2026) · Bioelectronic Medicine · doi:10.1186/s42234-025-00199-0 · Cited by 1
“…polystyrene sulfonate (PEDOT:PSS) can be spin coated or electrodeposited as an electrode coating using voltage or current cycling or sweeping, producing a porous surface and improvement in impedance and CIC (Carnicer-Lombarte et al. 2024; Duan et al. 2024; Ludwig et al. 2011; Shin et al. 2024).”
Research progress of neural implants: Toward robust brain-computer integration
Chen, Z., Tian, Y., Zeng, M., Wu, X., Wu, C., Wei, D., Sun, J. K., Zhou, L. E. T. A. O., Ding, J., & Fan, H. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.177125 · Cited by 1
Chen, S., Pei, W., Gui, Q., Chen, Y., Zhao, S., & Chen, H. (2013) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2013.6559758 · Cited by 1
“However, decreasing the size of an electrode site will increase the impedance at the electrode/electrolyte interface, which seriously impacts high-resolution recording and stimulation by two mechanisms: noise and shunt loss [6], both increasing in proportion to impedance.”
BackgroundSurgical Model for Analysis of Signal Transfer Through Biologic and Synthetic Materials
Larson, J. V., Kung, T. A., Cederna, P. S., Urbanchek, M. G., & Langhals, N. B. (2014) · Annals of Plastic Surgery · doi:10.1097/sap.0000000000000278 · Cited by 1
“However, smaller electrodes are more susceptible to material failure and demonstrate increased impedance, which degrades recordings through increased noise and shunt loss at the electrode/electrolyte interface.(28,29)”
BackgroundSelf-citationIntracranial epilepsy monitoring using wireless neural recording systems
Yılmaz, G., & Dehollain, C. (2015) · Cambridge University Press eBooks · doi:10.1017/cbo9781139629539.038 · Cited by 1
Progress in Peripheral Neural Interfaces
Qiao, S., Mauser, K. A., & Yoshida, K. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch4 · Cited by 1
Towards high-density recording of brain-wide neural activity
Liang, B., & Ye, X. (2018) · Science China Materials · doi:10.1007/s40843-017-9175-3 · Cited by 1
ULTRASONIC NEURAL PROBE FOR REAL TIME ELECTROMECHANICAL HISTOLOGY OF NEURAL INTERFACES
Chen, P. C., Shen, C.-C., Kuo, J. C., Clark, C. G., Nijjar, B., Schaffer, C. B., Gilmour, R. F., & Lal, A. (2012) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2012.10 · Cited by 1
Nguyen, H., Montes, J., Soroushiani, S., Sayeed, S. Y. B., Moncion, C., Riera, J. J., & Raj, P. M. (2021) · IEEE International Conference on Nanotechnology (IEEE-NANO) · doi:10.1109/nano51122.2021.9514286 · Cited by 1
Coatings for Microneural Implants: Electrical Considerations
Olczak, K. P., & Otto, K. J. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_7 · Cited by 1
A Novel Flexible Sinusoidal Probe for Chronic Extracellular Brain RecordingPreprint
Sohal, H. S., Vassilevski, K. V., Andrew, J. O., Baker, S. N., & O'Neill, A. G. (2015) · arXiv (Cornell University) · Cited by 2
Kuo, C.-C. (2017) · Library, Museums and Press - UDSpace (University of Delaware) · doi:10.58088/a8qw-2a87 · Cited by 3
Lonjaret, T. (2016) · theses.fr (ABES) · doi:10.70675/c0433ff9z257cz4b8dz86eazf6d5a1aea075 · Cited by 1
Xu, L. (2015) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign)
Sessolo, M., Ramuz, M. P., Malliaras, G. G., & Owens, R. M. (2015) · Cambridge University Press eBooks · doi:10.1017/cbo9781139629539.013
Conducting Polymer Devices for in vitro Electrophysiology
Koutsouras, D. A. (2016) · theses.fr (ABES) · doi:10.70675/906535ecz9a07z48c0zb86bz437331430b2b
Gunapu, D. V. S. K., & Vanjari, S. R. K. (2019) · Springer proceedings in physics · doi:10.1007/978-3-319-97604-4_129
Pas, J. (2017) · theses.fr (ABES) · doi:10.70675/d28426d3z2c05z40b0za9b0zf1e9d3cfeec0 · Cited by 3
“Conductive polymers, such as polypyrrole [42], [43] and PEDOT:PSS [42], [44]–[47], have therefore extensively been studied in order to exploit these features for use in the neuroscience field.”
BackgroundNanostructured Platforms Interfacing with Nervous System
Chen, N., Ramakrishna, S., & Thakor, N. V. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_17-1
Alba, N. A. (2013) · D-Scholarship@Pitt (University of Pittsburgh)
ZnO nanowire microelectrode arrays for integration with neuronal networks
Maddah, M. (2020) · Open Access Victoria University of Wellington | Te Herenga Waka (Figshare) · doi:10.26686/wgtn.17142146
Yılmaz, G., & Dehollain, C. (2017) · Analog circuits and signal processing/Analog circuits and signal processing series · doi:10.1007/978-3-319-49337-4_1
Nanostructured Platforms Interfacing with Nervous System
Chen, N., Ramakrishna, S., & Thakor, N. V. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_17
eLife assessment: Myomatrix arrays for high-definition muscle recording
Tuthill, J. C. (2023) · eLife · doi:10.7554/elife.88551.3.sa0
Peritumoral cortex : electrophysiological signals
Díaz-Fernández, B. (2023) · theses.fr (ABES) · doi:10.70675/500324e4zf697z4dd5z9c1fz693d3a606a57 · Cited by 2
Advanced Fibers for Optogenetic Modulation
Du, M., & Zhou, S. (2024) · Wiley eBooks · doi:10.1002/9783527839322.ch7
Biomaterials for Bionic Implants
Shokuhfar, T. (2025) · Wiley eBooks · doi:10.1002/9781119851004.ch8
Curved flexible neural interfaces for laminar electrophysiology in deep-brain structuresPreprint
Hagler, J., Pizzoccaro, L., Matos-Peralta, Y., Wang, M., Ducharme, G., Amilhon, B., & Cicoira, F. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.09.29.679383
“19 Based on this trade-off, a deposition charge density of 150 mC/cm 2 was selected for all subsequent in vivo experiments, providing the best compromise between low impedance and controlled coating morphology.”
Conducting Polymers for Use in Organic Bioelectronics
Zienkiewicz, J., & Tovar, J. D. (2025) · Springer handbooks · doi:10.1007/978-981-96-2498-0_31 · Cited by 1
Park, S., Lee, S., Lee, H., Kim, M. S., Lee, J., Chou, N., & Shin, H. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.117470
Elaboration, characterisation and applications of porous electrodes
Heim, M. (2011) · theses.fr (ABES) · doi:10.70675/79a359f7za39fz4cedz85efz868dd4bf4153 · Cited by 1
Conducting polymer devices for human electrophysiological recordings
Leleux, P. (2013) · theses.fr (ABES) · doi:10.70675/6502d354z560fz4a1bza46czc52ebfbc3239
Despouy, E. (2019) · theses.fr (ABES) · doi:10.70675/5903e0fdz9e05z4aa9z8acazb5f1f807aff8 · Cited by 1
Oxyde de graphène réduit et ses composites : préparation radiolytique et applications
Zeid, S. A. (2023) · theses.fr (ABES) · doi:10.70675/357888b3z1850z4f18z9e61z5708734b523e · Cited by 1
Closed-crown packaging system for stable, long-term neural recording in group-housed mice
Hong, Y., Kim, G., Lee, H., Cha, H., kim, M., Park, S. H., Lee, S., Chou, N., & Shin, H. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01293-2
“2d) 57 .”
Ma, J., Shao, M., Liu, J. J., Ma, N., Tang, Y., Wang, L., Xu, X., Qu, W., & Zhang, W. (2026) · ACS Applied Polymer Materials · doi:10.1021/acsapm.6c02118
Design of conformal planar penetrating multi-electrode arrays for recording multiple brain regions
Xu, H., Jin, Z., Gao, Y., Gong, Y., Liang, J., Lu, Z., Scholten, K., Li, X., Chen, L., Meng, E. F., et al. (2026) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ae92c4
“To further reduce impedance and enhance signal sensitivity, a wide range of surface modification strategies has been developed, including electrochemical roughening [26, 27], conductive polymer and nanocomposite coatings [28], and porous or nanostructured electrode surfaces [29, 30].”
From Sourcing to End‐of‐Life: Sustainability Challenges and Opportunities in Organic Bioelectronics
Dufil, G., Batista, M., Bionda, A., & Zeglio, E. (2026) · Advanced Science · doi:10.1002/advs.77121
Fan, H., Jing, S., Zhang, Z., Yue, Y., Li, K., Li, Z., & Chen, S. (2026) · SmartMat · doi:10.1002/smm2.70107
Pang, J., Zhu, W., He, X., Li, X., Zhu, D., Qiu, W., Wu, M., Cao, Y., & Pei, R. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.182314
CHARACTERIZATION, POLYMERIZATION, AND INVESTIGATION OF CHEMICALLY-MODIFIED THIOPHENES
Baugh, Q. (2026) · Library, Museums and Press - UDSpace (University of Delaware)
Nelson, T. A., Hsueh, B., Hadar, P., Das, I., Coughlin, B. F., Mandal, A. S., Wilson, T., Peng, E., Perley, A. S., Rabbani, H., et al. (2026) · medRxiv · doi:10.64898/2026.10.05.26364665
“46,52,60,93 In summary, PEDOT:PSS grids are composed of thin-film poly(3,4-ethylenedioxythiophene) with polystyrene sulfonate 45,50 .”
Ebrahimi, S., Khoomortezaei, S., Petrossian, G., Ursino, F., Quenneville, E., & Cicoira, F. (2026) · ChemistryEurope · doi:10.1002/ceur.70372
Electrochemical Stability of Electrodeposited PEDOT:PSS Neural Stimulation Electrodes
Azami, A., Wu, Y., Nguyen, C. K., Abbott, J., Orazem, M. E., Otto, K. J., Cogan, S. F., & Kim, B. N. (2026) · Micromachines · doi:10.3390/mi17101198
“Previous studies have shown that PEDOT:PSS provides a high signal-to-noise ratio and excellent neural recording quality [32,33], and high charge-injection capacity with stability suitable for chronic neural stimulation [34–36].”
Conducting polymers for implantable neural electrodes in brain–computer interfaces
Zhu, J., Liu, R., Jiang, H., Liu, X., Kong, Z., Wang, L., Xu, W., & Wang, Y. (2026) · Journal of Materials Chemistry B · doi:10.1039/d6tb01636g
Multimodal in vitro biocompatibility assessment of functionalized PEDOT neural interfaces
Saghir, S., Hlinková, J., SAMARA, A. A., & Schiavone, G. (2026) · iScience · doi:10.1016/j.isci.2026.118078
Vreeland, R. F. (2015) · UA Campus Repository (The University of Arizona)
Metadata
- Authors
- Ludwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Joseph, Mike D
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-01-19
- Volume
- 8
- Issue
- 1
- Pages
- 014001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC3415981
- OpenAlex
- W1989403232
- Semantic Scholar
- 6d5753ae05ba9eef39fd53ccfd3c85017e21dd1d
- Cited by
- 283
- References
- 42
- Citations by year
- 2026: 18 · 2025: 18 · 2024: 9 · 2023: 18 · 2022: 16 · 2021: 23 · 2020: 27 · 2019: 18 · 2018: 24 · 2017: 22 · 2016: 18 · 2015: 32 · 2014: 14 · 2013: 11 · 2012: 9
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- Funders
- National Science Foundation (9986866)
- University of Michigan
- National Institutes of Health
- National Institute of Biomedical Imaging and Bioengineering (P41EB002030)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- PEDOT, neural recording electrodes, electrode impedance, gold electrode, electrode coating, chronic implantation, noise floor, immune response
- MeSH terms
- Animals, Biocompatible Materials, Electrodes, Implanted, Male, Microelectrodes, Motor Cortex, Neurons, Polymers, Rats, Sprague-Dawley, Bridged Bicyclo Compounds, Heterocyclic, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.