Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodes
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
We investigated using poly(3,4-ethylenedioxythiophene) (PEDOT) to lower the impedance of small, gold recording electrodes with initial impedances outside of the effective recording range. Smaller electrode sites enable more densely packed arrays, increasing the number of input and output channels to and from the brain. Moreover, smaller electrode sizes promote smaller probe designs; decreasing the dimensions of the implanted probe has been demonstrated to decrease the inherent immune response, a known contributor to the failure of long-term implants. As expected, chronically implanted control electrodes were unable to record well-isolated unit activity, primarily as a result of a dramatically increased noise floor. Conversely, electrodes coated with PEDOT consistently recorded high-quality neural activity, and exhibited a much lower noise floor than controls. These results demonstrate that PEDOT coatings enable electrode designs 15 µm in diameter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While the smaller electrode sites necessitated by finer-scale geometries have the drawback of increased impedance, inclusion of conductive polymers mitigates this effect and allows improved signal detection.71,72”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [72]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geometric Control of Cell Life and Death
Chen, C. S., Mrksich, M., Huang, S., Whitesides, G. M., & Ingber, D. E. (1997) · Science · doi:10.1126/science.276.5317.1425 · Cited by 4,657
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
A review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x/9/4/001 · Cited by 1,370 · cited 1×
“The remaining eight sites on each probe were left uncoated as controls for comparison.”
MethodHarris, K. D., Henze, D. A., Csicsvari, J., Hirase, H., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.401 · Cited by 1,151
Specific proteins mediate enhanced osteoblast adhesion on nanophase ceramics
Webster, T. J., Ergun, C., Doremus, R. H., Siegel, R. W., & Bizios, R. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20000905)51:3<299::aid-jbm2>3.0.co;2-8 · Cited by 995
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942 · cited 1×
“Site and shank separations were sufficient (100 μm or greater) to limit the probability of an individual neuron being recorded from multiple sites [23].”
BackgroundBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721 · cited 1×
“(Some figures in this article are in colour only in the electronic version)”
BackgroundLudwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · cited 10×
“After initial principal component analysis and fuzzy Cmeans clustering [12], waveforms with a cluster membership index of greater than 0.”
BackgroundMethodResultInfluentialSelf-citationCerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Cui, X., & Martin, D. C. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00448-3 · Cited by 573
Richardson-Burns, S. M., Hendricks, J. L., Foster, B., Povlich, L. K., Kim, D.-H., & Martin, D. C. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.026 · Cited by 503
Self-citationChronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475 · cited 1×
“This time point is important, as the contribution of encapsulation to electrode impedance typically reaches a maximum one to two weeks post-surgery [12, 21, 28, 40], demonstrating that PEDOT coatings enable neural recordings from small electrode sites even when the impedance contribution of encapsulation is at a maxim…”
BackgroundSelf-citationThe electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 464 · cited 5×
“Second, a resistive element models the loss of signal from the inherent resistive nature of the metal wiring from the electrode to the measurement system [9].”
BackgroundInfluentialNeural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
Self-citationUsing a Common Average Reference to Improve Cortical Neuron Recordings From Microelectrode Arrays
Ludwig, K. A., Miriani, R. M., Langhals, N. B., Joseph, M. D., Anderson, D. J., & Kipke, D. R. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90989.2008 · Cited by 420 · cited 3×
“A decreasing trend in unit activity in the week following surgery has been noted elsewhere [12, 25, 26, 32] and is hypothesized to be caused by edema/swelling coupled with the initial immune response.”
BackgroundMethodResultSelf-citationAbidian, M. R., Corey, J. M., Kipke, D. R., & Martin, D. C. (2010) · Small · doi:10.1002/smll.200901868 · Cited by 405
Self-citationComplex impedance spectroscopy for monitoring tissue responses to inserted neural implants
Williams, J. C., Hippensteel, J. A., Dilgen, J., Shain, W., & Kipke, D. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/007 · Cited by 399
Self-citationElectrical properties of implant encapsulation tissue
Grill, W. M., & Thomas Mortimer, J. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368219 · Cited by 376
Abidian, M. R., & Martin, D. C. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.022 · Cited by 338
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 286 · cited 1×
“At present, researchers are limited to sampling from a few neurons out of the billions of neurons which execute function in the brain [1].”
BackgroundSelf-citationLiu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788468 · Cited by 271 · cited 1×
“Inserting a microelectrode into brain tissue elicits a reactive foreign body response, which produces a fibrous encapsulation of the array, effectively creating a high impedance barrier between the microelectrode and the neuron population [33– 35].”
BackgroundAbidian, M. R., Ludwig, K. A., Marzullo, T. C., Martin, D. C., & Kipke, D. R. (2009) · Advanced Materials · doi:10.1002/adma.200900887 · Cited by 255 · cited 1×
“(Some figures in this article are in colour only in the electronic version)”
BackgroundSelf-citationNeuroprosthetics : Theory and Practice
Horch, K., & Dhillon, G. S. (2004) · doi:10.1142/4987#t=toc · Cited by 215
Enabling Technologies for Cultured Neural Networks
Stenger, D. A., & McKenna, T. M. (1994) · Cited by 214
Comprehensive study of noise processes in electrode electrolyte interfaces
Hassibi, A., Navid, R., Dutton, R. W., & Lee, T. H. (2004) · Journal of Applied Physics · doi:10.1063/1.1755429 · Cited by 199 · cited 1×
“(Some figures in this article are in colour only in the electronic version)”
BackgroundElectrochemical polymerization of conducting polymers in living neural tissue
Richardson-Burns, S. M., Hendricks, J. L., & Martin, D. C. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/l02 · Cited by 195
Self-citationWilks, S. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.007.2009 · Cited by 188
Self-citationAttachment of astroglial cells to microfabricated pillar arrays of different geometries
Turner, A. M. P., Dowell, N., Turner, S. W. P., Kam, L., Isaacson, M., Turner, J. N., Craighead, H. G., & Shain, W. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20000905)51:3<430::aid-jbm18>3.0.co;2-c · Cited by 184 · cited 1×
“Recent studies have indicated that by reducing the size of the implanted electrode, the foreign-body response to the electrode can be minimized, decreasing the contribution of encapsulation to impedance [3, 4, 41, 42] and possibly limiting neuronal death in the vicinity of the electrode array [43].”
BackgroundSilicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174 · cited 1×
“Typically, electrodes with impedances of 5 M or greater have levels of fluctuation noise and shunt loss that make recording from individual neurons problematic [5, 9, 11].”
BackgroundScaling limitations of silicon multichannel recording probes
Najafi, K., Ji, J., & Wise, K. D. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43605 · Cited by 163 · cited 1×
“Typically, electrodes with impedances of 5 M or greater have levels of fluctuation noise and shunt loss that make recording from individual neurons problematic [5, 9, 11].”
BackgroundHermesB: A Continuous Neural Recording System for Freely Behaving Primates
Santhanam, G., Linderman, M. D., Gilja, V., Afshar, A., Ryu, S. I., Meng, T. H., & Shenoy, K. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895753 · Cited by 136 · cited 1×
“A decreasing trend in unit activity in the week following surgery has been noted elsewhere [12, 25, 26, 32] and is hypothesized to be caused by edema/swelling coupled with the initial immune response.”
BackgroundYang, J., Kim, D., Hendricks, J. L., Leach, M. K., Northey, R., & Martin, D. C. (2004) · Acta Biomaterialia · doi:10.1016/j.actbio.2004.09.006 · Cited by 135 · cited 1×
“PEDOT doped with tetraethylammonium perchlorate and dissolved in 20 wt% surfactant poly(oxyethylene)10-oleyl ether was galvanostatically deposited onto the gold sites of the neural probes [24].”
MethodSelf-citationOtto, K. J., Johnson, M. D., & Kipke, D. R. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862530 · Cited by 131
Self-citationInteraction of macrophages with fibrous materials in vitro
Bernatchez, S. F., Parks, P. J., & Gibbons, D. F. (1996) · Biomaterials · doi:10.1016/0142-9612(96)00014-2 · Cited by 71
Flavopiridol reduces the impedance of neural prostheses in vivo without affecting recording quality
Purcell, E. K., Thompson, D. E., Ludwig, K. A., & Kipke, D. R. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.06.026 · Cited by 62 · cited 1×
“This time point is important, as the contribution of encapsulation to electrode impedance typically reaches a maximum one to two weeks post-surgery [12, 21, 28, 40], demonstrating that PEDOT coatings enable neural recordings from small electrode sites even when the impedance contribution of encapsulation is at a maxim…”
BackgroundSelf-citationRohatgi, P., Langhals, N. B., Kipke, D. R., & Patil, P. G. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0983 · Cited by 59
Self-citationBuitenweg, J., Rutten, W., Willems, W. P. M., & van Nieuwkasteele, J. V. (1998) · Medical and Biological Engineering and Computing · doi:10.1007/bf02524436 · Cited by 52
Neurophysiological Techniques, I
Boulton, A. A., Baker, G. B., & Vanderwolf, C. H. (1990) · Humana Press eBooks · doi:10.1385/0896031608 · Cited by 28
Validation of a novel three-dimensional electrode array within auditory cortex
Langhals, N. B., & Kipke, D. R. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333958 · Cited by 9
Self-citationAbidian, M. R., Ludwig, K. A., Marzullo, T., Martin, D. C., & Kipke, D. R. (2009) · Advanced Materials · doi:10.1002/adma.200990142 · Cited by 7
Self-citation(2000) · doi:10.1002/1097-4636(200010)52:1<231::aid-jbm29>3.0.co;2-e · cited 1×
“Recent studies have indicated that by reducing the size of the implanted electrode, the foreign-body response to the electrode can be minimized, decreasing the contribution of encapsulation to impedance [3, 4, 41, 42] and possibly limiting neuronal death in the vicinity of the electrode array [43].”
Background
Research works printed but not linked: 3
- Schmidt E Humphrey DR Neurophysiological techniques 1990 2 1 64 Humana Press
- Vetter RJ Williams JC Hetke JF Nunamaker EA Kipke DR Spike recording performance of implanted chronic silicon-substrate microelectrode arrays in cerebral cortex. IEEE Transactions on Neural Systems and Rehabilitation Engineering 2004 52
- Purcell EK Thompson DE Ludwig KA Kipke DR Flavopiridol reduces the impedance of neural prostheses in vivo without affecting recording quality. J Neurosci Methods 2009 doi:S0165-0270(09)00344-6 [pii] 10.1016/j.jneumeth.2009.06.026 19560490 · DOI · Paper page
Cited by
Fully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
Self-citationConjugated Polymers in Bioelectronics
Inal, S., Rivnay, J., Suiu, A.-O., Malliaras, G. G., & McCulloch, I. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00624 · Cited by 551
Metadata
- Authors
- Ludwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Joseph, Mike D
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-01-19
- Volume
- 8
- Issue
- 1
- Pages
- 014001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC3415981
- OpenAlex
- W1989403232
- Semantic Scholar
- 6d5753ae05ba9eef39fd53ccfd3c85017e21dd1d
- Cited by
- 283
- References
- 42
- Citations by year
- 2026: 18 · 2025: 18 · 2024: 9 · 2023: 18 · 2022: 16 · 2021: 23 · 2020: 27 · 2019: 18 · 2018: 24 · 2017: 22 · 2016: 18 · 2015: 32 · 2014: 14 · 2013: 11 · 2012: 9
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- Funders
- National Science Foundation (9986866)
- University of Michigan
- National Institutes of Health
- National Institute of Biomedical Imaging and Bioengineering (P41EB002030)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- PEDOT, neural recording electrodes, electrode impedance, gold electrode, electrode coating, chronic implantation, noise floor, immune response
- MeSH terms
- Animals, Biocompatible Materials, Electrodes, Implanted, Male, Microelectrodes, Motor Cortex, Neurons, Polymers, Rats, Sprague-Dawley, Bridged Bicyclo Compounds, Heterocyclic, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.