CoChat

Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodes

Open access

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Abstract

We investigated using poly(3,4-ethylenedioxythiophene) (PEDOT) to lower the impedance of small, gold recording electrodes with initial impedances outside of the effective recording range. Smaller electrode sites enable more densely packed arrays, increasing the number of input and output channels to and from the brain. Moreover, smaller electrode sizes promote smaller probe designs; decreasing the dimensions of the implanted probe has been demonstrated to decrease the inherent immune response, a known contributor to the failure of long-term implants. As expected, chronically implanted control electrodes were unable to record well-isolated unit activity, primarily as a result of a dramatically increased noise floor. Conversely, electrodes coated with PEDOT consistently recorded high-quality neural activity, and exhibited a much lower noise floor than controls. These results demonstrate that PEDOT coatings enable electrode designs 15 µm in diameter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1741-2560/8/1/014001

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 3

  1. Schmidt E Humphrey DR Neurophysiological techniques 1990 2 1 64 Humana Press
  2. Vetter RJ Williams JC Hetke JF Nunamaker EA Kipke DR Spike recording performance of implanted chronic silicon-substrate microelectrode arrays in cerebral cortex. IEEE Transactions on Neural Systems and Rehabilitation Engineering 2004 52
  3. Purcell EK Thompson DE Ludwig KA Kipke DR Flavopiridol reduces the impedance of neural prostheses in vivo without affecting recording quality. J Neurosci Methods 2009 doi:S0165-0270(09)00344-6 [pii] 10.1016/j.jneumeth.2009.06.026 19560490 · DOI · Paper page

Cited by

See all 297

Metadata

Authors
Ludwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R.
Affiliations
University of Michigan (US)
Corresponding author
Joseph, Mike D
Venue
Journal of Neural Engineering
Published
2011-01-19
Volume
8
Issue
1
Pages
014001
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W1989403232
Cited by
283
References
42
Citations by year
2026: 18 · 2025: 18 · 2024: 9 · 2023: 18 · 2022: 16 · 2021: 23 · 2020: 27 · 2019: 18 · 2018: 24 · 2017: 22 · 2016: 18 · 2015: 32 · 2014: 14 · 2013: 11 · 2012: 9
FWCI
5.30
Type
journal article
Language
en
Open access
Locations
  • Journal of Neural Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
  • Deep Blue (University of Michigan) (submittedVersion)
Funders
  • National Science Foundation (9986866)
  • University of Michigan
  • National Institutes of Health
  • National Institute of Biomedical Imaging and Bioengineering (P41EB002030)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
Keywords
PEDOT, neural recording electrodes, electrode impedance, gold electrode, electrode coating, chronic implantation, noise floor, immune response
MeSH terms
Animals, Biocompatible Materials, Electrodes, Implanted, Male, Microelectrodes, Motor Cortex, Neurons, Polymers, Rats, Sprague-Dawley, Bridged Bicyclo Compounds, Heterocyclic, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.