Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodes
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
We investigated using poly(3,4-ethylenedioxythiophene) (PEDOT) to lower the impedance of small, gold recording electrodes with initial impedances outside of the effective recording range. Smaller electrode sites enable more densely packed arrays, increasing the number of input and output channels to and from the brain. Moreover, smaller electrode sizes promote smaller probe designs; decreasing the dimensions of the implanted probe has been demonstrated to decrease the inherent immune response, a known contributor to the failure of long-term implants. As expected, chronically implanted control electrodes were unable to record well-isolated unit activity, primarily as a result of a dramatically increased noise floor. Conversely, electrodes coated with PEDOT consistently recorded high-quality neural activity, and exhibited a much lower noise floor than controls. These results demonstrate that PEDOT coatings enable electrode designs 15 µm in diameter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While the smaller electrode sites necessitated by finer-scale geometries have the drawback of increased impedance, inclusion of conductive polymers mitigates this effect and allows improved signal detection.71,72”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [72]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geometric Control of Cell Life and Death
Chen, C. S., Mrksich, M., Huang, S., Whitesides, G. M., & Ingber, D. E. (1997) · Science · doi:10.1126/science.276.5317.1425 · Cited by 4,657
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
A review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x/9/4/001 · Cited by 1,370 · cited 1×
“The remaining eight sites on each probe were left uncoated as controls for comparison.”
MethodHarris, K. D., Henze, D. A., Csicsvari, J., Hirase, H., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.401 · Cited by 1,151
Specific proteins mediate enhanced osteoblast adhesion on nanophase ceramics
Webster, T. J., Ergun, C., Doremus, R. H., Siegel, R. W., & Bizios, R. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20000905)51:3<299::aid-jbm2>3.0.co;2-8 · Cited by 995
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942 · cited 1×
“Site and shank separations were sufficient (100 μm or greater) to limit the probability of an individual neuron being recorded from multiple sites [23].”
BackgroundBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721 · cited 1×
“(Some figures in this article are in colour only in the electronic version)”
BackgroundLudwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · cited 10×
“After initial principal component analysis and fuzzy Cmeans clustering [12], waveforms with a cluster membership index of greater than 0.”
BackgroundMethodResultInfluentialSelf-citation
Research works printed but not linked: 3
- Schmidt E Humphrey DR Neurophysiological techniques 1990 2 1 64 Humana Press
- Vetter RJ Williams JC Hetke JF Nunamaker EA Kipke DR Spike recording performance of implanted chronic silicon-substrate microelectrode arrays in cerebral cortex. IEEE Transactions on Neural Systems and Rehabilitation Engineering 2004 52
- Purcell EK Thompson DE Ludwig KA Kipke DR Flavopiridol reduces the impedance of neural prostheses in vivo without affecting recording quality. J Neurosci Methods 2009 183 149 157 doi:S0165-0270(09)00344-6 [pii] 10.1016/j.jneumeth.2009.06.026 19560490 · DOI · Paper page
Cited by
Fully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
Self-citationConjugated Polymers in Bioelectronics
Inal, S., Rivnay, J., Suiu, A.-O., Malliaras, G. G., & McCulloch, I. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00624 · Cited by 551
Current and Novel Polymeric Biomaterials for Neural Tissue Engineering
Boni, R., Ali, A., Shavandi, A., & Clarkson, A. N. (2018) · Journal of Biomedical Science · doi:10.1186/s12929-018-0491-8 · Cited by 439
Lustgarten, D. L., Crespo, E. M., Arkhipova-Jenkins, I., Lobel, R., Winget, J., Koehler, J., Liberman, E., & Sheldon, T. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.03.048 · Cited by 415
Conducting Polymers for Neural Prosthetic and Neural Interface Applications
Green, R., & Abidian, M. R. (2015) · Advanced Materials · doi:10.1002/adma.201501810 · Cited by 392
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Self-citationProgress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“(43, 320) It was found that chronically implanted control microelectrodes were unable to record well-isolated unit activity due to a dramatically increased noise floor, while PEDOT-coated Michigan-style microelectrodes consistently recorded neural activity, and showed a much lower noise floor than un-coated gold-based…”
BackgroundRepresentational drift in primary olfactory cortex
Schoonover, C. E., Ohashi, S. N., Axel, R., & Fink, A. J. P. (2021) · Nature · doi:10.1038/s41586-021-03628-7 · Cited by 313
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
Organic electrode coatings for next-generation neural interfaces
Aregueta-Robles, U. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 254
Easy‐to‐Fabricate Conducting Polymer Microelectrode Arrays
Sessolo, M., Khodagholy, D., Rivnay, J., Maddalena, F., Gleyzes, M., Steidl, E., Buisson, B., & Malliaras, G. G. (2013) · Advanced Materials · doi:10.1002/adma.201204322 · Cited by 243
Liang, Y., Offenhäusser, A., Ingebrandt, S., & Mayer, D. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100061 · Cited by 239
The BRAIN Initiative: developing technology to catalyse neuroscience discovery
Jorgenson, L. A., Newsome, W. T., Anderson, D. J., Bargmann, C. I., Brown, E. N., Deisseroth, K., Donoghue, J. P., Hudson, K. L., Ling, G. S. F., MacLeish, P. R., et al. (2015) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2014.0164 · Cited by 238
Multiplexed, High Density Electrophysiology with Nanofabricated Neural Probes
Du, J., Blanche, T. J., Harrison, R. R., Lester, H. A., & Masmanidis, S. C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026204 · Cited by 231
“This trend toward lower noise was strongly correlated with the accompanying reduction in site impedance (Figure 5C,D), confirming that gold electroplating is an effective way to minimize noise of electrodes with small geometric areas [22].”
BackgroundKozai, T. D. Y., Catt, K., Li, X., Gugel, Z. V., Olafsson, V. T., Vazquez, A. L., & Cui, X. T. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.040 · Cited by 218
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
“Similar to (a), values for 177 μm(2) silicon sites coated with PEDOT are shown in green [53].”
BackgroundMethodResultInfluentialBoehler, C., Oberueber, F., Schlabach, S., Stieglitz, T., & Asplund, M. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b13468 · Cited by 200
Chronic In Vivo Evaluation of PEDOT/CNT for Stable Neural Recordings
Kozai, T. D. Y., Catt, K., Du, Z., Na, K., Srivannavit, O., Haque, R.-U. M., Seymour, J., Wise, K. D., Yoon, E., & Cui, X. T. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2445713 · Cited by 197
“The trace material was polysilicon, and the electrode material was Au because of its known compatibility with PEDOT electrodeposition [12].”
Actively controlled release of Dexamethasone from neural microelectrodes in a chronic in vivo study
Boehler, C., Kleber, C., Martini, N., Xie, Y., Dryg, I., Stieglitz, T., Hofmann, U. G., & Asplund, M. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.03.019 · Cited by 196
Gerwig, R., Fuchsberger, K., Schroeppel, B., Link, G. S., Heusel, G., Kraushaar, U., Schuhmann, W., Stett, A., & Stelzle, M. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00008 · Cited by 187
“Their excellent electronic and ionic conductivity providing for low impedance and high capacitance (Skotheim, 1998; Green et al., 2008; Inzelt, 2008; Ludwig et al., 2011), the ease of fabrication by electropolymerization (Skotheim, 1998; Inzelt, 2008), their suitability for the construction of…”
BackgroundInfluentialKung, T. A., Langhals, N. B., Martin, D. C., Johnson, P. J., Cederna, P. S., & Urbanchek, M. G. (2014) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000000168 · Cited by 181
Self-citationBreathing coordinates cortico-hippocampal dynamics in mice during offline states
Karalis, N., & Sirota, A. (2022) · Nature Communications · doi:10.1038/s41467-022-28090-5 · Cited by 179
Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178
“ORIGINAL RESEARCH ARTICLE published: 04 February 2014 doi: 10.3389/fneng.2014.00002 Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants”
BackgroundInfluentialTakmakov, P., Ruda, K., Scott Phillips, K., Isayeva, I. S., Krauthamer, V., & Welle, C. G. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026003 · Cited by 178
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
Xu, L., Gutbrod, S. R., Ma, Y., Petrossians, A., Liu, Y., Webb, R. C., Fan, J. A., Yang, Z., Xu, R., Whalen, J. J., et al. (2015) · Advanced Materials · doi:10.1002/adma.201405017 · Cited by 173
Shin, H., Son, Y., Chae, U., Kim, J., Choi, N., Lee, H. J., Woo, J., Cho, Y., Yang, S. H., Lee, C. J., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-11628-5 · Cited by 169
Szostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 168
“It is believed that an electrode of the size comparable to neuronal body (12–15 μm) could lessen implantation trauma and reduce tissue’s displacement and mechanical mismatch (Ludwig et al., 2011).”
BackgroundInfluentialQuantifying long-term microelectrode array functionality using chronic in vivo impedance testing
Prasad, A., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026028 · Cited by 157
Vomero, M., Castagnola, E., Ciarpella, F., Maggiolini, E., Goshi, N., Zucchini, E., Carli, S., Fadiga, L., Kassegne, S., & Ricci, D. (2017) · Scientific Reports · doi:10.1038/srep40332 · Cited by 158
“To improve the electrochemical properties of the conductive surface, aiming to further miniaturize the electrodes 41 , we electrodeposited PEDOT-PSS on GC and Pt and studied the ability of the conductive polymer to grow and adhere to the two different substrates.”
Translational opportunities and challenges of invasive electrodes for neural interfaces
Shen, K., Chen, O., Edmunds, J. L., Piech, D. K., & Maharbiz, M. M. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01021-5 · Cited by 161
Nanofabricated Ultraflexible Electrode Arrays for High‐Density Intracortical Recording
Wei, X., Luan, L., Zhao, Z., Li, X., Zhu, H., Potnis, O., & Xie, C. (2018) · Advanced Science · doi:10.1002/advs.201700625 · Cited by 146
Bioelectronic neural pixel: Chemical stimulation and electrical sensing at the same site
Jonsson, A., Inal, S., Uguz, I., Williamson, A., Kergoat, L., Rivnay, J., Khodagholy, D., Berggren, M., Bernard, C., Malliaras, G. G., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1604231113 · Cited by 142
In Vivo Electrochemical Analysis of a PEDOT/MWCNT Neural Electrode Coating
Alba, N., Du, Z., Catt, K., Kozai, T., & Cui, X. (2015) · Biosensors · doi:10.3390/bios5040618 · Cited by 137
Flexible fiber-based optoelectronics for neural interfaces
Park, S., Loke, G., Fink, Y., & Anikeeva, P. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00710a · Cited by 134
Ganji, M., Tanaka, A., Gilja, V., Halgren, E., & Dayeh, S. A. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201703019 · Cited by 126
Wan, A. M. D., Inal, S., Williams, T. V., Wang, K., Leleux, P., Estevez, L., Giannelis, E. P., Fischbach, C., Malliaras, G. G., & Gourdon, D. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00390c · Cited by 142
Lee, J. H., Kim, H., Kim, J. H., & Lee, S.-H. (2016) · Lab on a Chip · doi:10.1039/c5lc00842e · Cited by 124
Applications of PEDOT in Bioelectronic Medicine
Boehler, C., Aqrawe, Z., & Asplund, M. (2019) · Bioelectronics in Medicine · doi:10.2217/bem-2019-0014 · Cited by 131
The Argo: a high channel count recording system for neural recording in vivo
Sahasrabuddhe, K., Khan, A. A., Singh, A. P., Stern, T. M., Ng, Y., Tadić, A., Orel, P., LaReau, C., Pouzzner, D., Nishimura, K., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abd0ce · Cited by 124
A physical action potential generator: design, implementation and evaluation
Latorre, M. A., Chan, A. D. C., & Wårdell, K. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00371 · Cited by 123
Sensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
“Conducting polymer nanotubes have also been used to dramatically decrease impedance when attached to the surface of the electrode sites (42), potentially enabling the creation of thinner but still functional recording electrodes (43) that can be more densely placed in cortex without overly disturbing the surrounding t…”
Conducting Polymer Nanomaterials for Biomedical Applications: Cellular Interfacing and Biosensing
Oh, W., Kwon, O. S., & Jang, J. (2013) · Journal of macromolecular science. Part C, Reviews in macromolecular chemistry and physics/Journal of macromolecular science. Reviews in macromolecular chemistry and physics · doi:10.1080/15583724.2013.805771 · Cited by 127
Wearable Heart Rate Sensor Systems for Wireless Canine Health Monitoring
Brugarolas, R., Latif, T., Dieffenderfer, J. P., Walker, K., Yuschak, S., Sherman, B. L., Roberts, D. L., & Bozkurt, A. Y. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2485210 · Cited by 128
Electroactive material-based biosensors for detection and drug delivery
Olvera, D., & Monaghan, M. G. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.09.011 · Cited by 121
Pure graphene oxide doped conducting polymer nanocomposite for bio-interfacing
Luo, X., Weaver, C. L., Tan, S., & Cui, X. T. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb00006k · Cited by 116
Eles, J. R., Vazquez, A. L., Snyder, N. R., Lagenaur, C., Murphy, M. C., Kozai, T. D. Y., & Cui, X. T. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2016.10.054 · Cited by 118
Development of a regenerative peripheral nerve interface for control of a neuroprosthetic limb
Urbanchek, M. G., Kung, T. A., Frost, C. M., Martin, D. C., Larkin, L. M., Wollstein, A., & Cederna, P. S. (2016) · BioMed Research International · doi:10.1155/2016/5726730 · Cited by 114
Recent trends in microelectrode array technology for in vitro neural interface platform
Kim, R., Joo, S., Jung, H., Hong, N., & Nam, Y. (2014) · Biomedical Engineering Letters · doi:10.1007/s13534-014-0130-6 · Cited by 121
“7 ~ 20 folds decrease, resulting in background noise reduction from 106 ~ 116 μV to 35 ~ 51 μV [48].”
Does Impedance Matter When Recording Spikes With Polytrodes?
Neto, J. P., Baião, P., Lopes, G., Frazão, J., Nogueira, J., Fortunato, E., Barquinha, P., & Kampff, A. R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00715 · Cited by 103
“Over the last decade, conductive polymers, particularly poly(3,4ethylenedioxythiophene) (PEDOT), have been electrodeposited onto electrodes due to their chemical stability and mechanical integrity when implanted in the brain [5], [6], [21].”
BackgroundThe sinusoidal probe: a new approach to improve electrode longevity
Sohal, H. S., Jackson, A., Jackson, R., Clowry, G. J., Vassilevski, K., O’Neill, A., & Baker, S. N. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00010 · Cited by 106
“ELECTRODE IMPEDANCE All sinusoidal probes had pre-implantation impedances less than the 4–5 M considered the limit for single unit recordings (Ludwig et al., 2006, 2011).”
Layer 4 fast-spiking interneurons filter thalamocortical signals during active somatosensation
Yu, J., Gutnisky, D. A., Hires, S. A., & Svoboda, K. (2016) · Nature Neuroscience · doi:10.1038/nn.4412 · Cited by 113
DVS‐Crosslinked PEDOT:PSS Free‐Standing and Textile Electrodes toward Wearable Health Monitoring
del Agua, I., Mantione, D., Ismailov, U., Sanchez‐Sanchez, A., Aranburu, N., Malliaras, G. G., Mecerreyes, D., & Ismailova, E. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201700322 · Cited by 110
Functionalization Strategies of PEDOT and PEDOT:PSS Films for Organic Bioelectronics Applications
Fenoy, G. E., Azzaroni, O., Knoll, W., & Marmisollé, W. A. (2021) · Chemosensors · doi:10.3390/chemosensors9080212 · Cited by 107
Zhou, H., Cheng, X., Rao, L., Li, T., & Duan, Y. Y. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.01.042 · Cited by 105
Bianchi, M., Salvo, A. D., Asplund, M., Carli, S., Lauro, M. D., Schulze‐Bonhage, A., Stieglitz, T., Fadiga, L., & Biscarini, F. (2022) · Advanced Science · doi:10.1002/advs.202104701 · Cited by 100
Conducting polymers for neuronal microelectrode array recording and stimulation
Aqrawe, Z., Montgomery, J. M., Travaš‐Sejdić, J., & Svirskis, D. M. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.11.023 · Cited by 102
Open source silicon microprobes for high throughput neural recording
Yang, L., Lee, K., Villagracia, J., & Masmanidis, S. C. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab581a · Cited by 91
“In addition to gold, the devices can be electroplated with other electrode materials, such as PEDOT [33] and platinum–iridium alloys (Platinum Group Coatings) [34].”
BackgroundElectrode modifications to lower electrode impedance and improve neural signal recording sensitivity
Tin, C., Wang, J. Q., Wang, J., Cao, B., Li, Y., & Pang, S. W. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/056018 · Cited by 97
Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f8b · Cited by 89
Agorelius, J., Tsanakalis, F., Friberg, A., Thorbergsson, P. T., Pettersson, L. M. E., & Schouenborg, J. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00331 · Cited by 93
“For example, the exposed de-insulated tips may be provided with surface enlargements to reduce the impedance and thereby the noise level, e.g., by electroplating procedures (Desai et al., 2010; Ludwig et al., 2011; Ejserholm et al., 2014).”
BackgroundThe development of neural stimulators: a review of preclinical safety and efficacy studies
Shepherd, R. K., Villalobos, J., Burns, O., & Nayagam, D. A. X. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac43c · Cited by 86
Samba, R., Herrmann, T., & Zeck, G. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016014 · Cited by 79
Mandal, H. S., Knaack, G. L., Charkhkar, H., McHail, D. G., Kastee, J. S., Dumas, T. C., Peixoto, N., Rubinson, J. F., & Pancrazio, J. J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.029 · Cited by 81
Can One Concurrently Record Electrical Spikes from Every Neuron in a Mammalian Brain?
Kleinfeld, D., Luan, L., Mitra, P. P., Robinson, J. T., Sarpeshkar, R., Shepard, K. L., Xie, C., & Harris, T. D. (2019) · Neuron · doi:10.1016/j.neuron.2019.08.011 · Cited by 83
Wu, X., Surendran, A., Moser, M., Chen, S., Muhammad, B. T., Maria, I. P., McCulloch, I. A., & Leong, W. L. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c04776 · Cited by 78
He, F., Sullender, C. T., Zhu, H., Williamson, M. R., Li, X., Zhao, Z., Jones, T. A., Xie, C., Dunn, A. K., & Luan, L. (2020) · Science Advances · doi:10.1126/sciadv.aba1933 · Cited by 81
Nanoparticle Doped PEDOT for Enhanced Electrode Coatings and Drug Delivery
Woeppel, K. M., Zheng, X. S., Schulte, Z. M., Rosi, N. L., & Cui, X. T. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900622 · Cited by 78
Ganji, M., Elthakeb, A. T., Tanaka, A., Gilja, V., Halgren, E., & Dayeh, S. A. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201703018 · Cited by 80
Lee, Y., Shin, H., Lee, D., Choi, S., Cho, I., & Seo, J. (2021) · Advanced Science · doi:10.1002/advs.202100231 · Cited by 77
Neuroadhesive protein coating improves the chronic performance of neuroelectronics in mouse brain
Golabchi, A., Woeppel, K. M., Li, X., Lagenaur, C. F., & Cui, X. T. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112096 · Cited by 77
“2012), and conducting polymers (CPs) (Cui et al. 2003; Du et al. 2015; Kozai et al. 2016a; Ludwig et al. 2011) into the electrode surface to improve not only electrode material properties like charge transfer and impedance, but also enhancing tissue Golabchi et al.”
BackgroundKang, K., Lee, S., Kim, R., Choi, I. S., & Nam, Y. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201207129 · Cited by 72
Neural and electromyography PEDOT electrodes for invasive stimulation and recording
Rossetti, N., Hagler, J., Kateb, P., & Cicoira, F. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc00625h · Cited by 79
Heim, M., Yvert, B., & Kuhn, A. (2011) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2011.10.001 · Cited by 88
Microelectrode Arrays for Simultaneous Electrophysiology and Advanced Optical Microscopy
Middya, S., Curto, V. F., Fernández‐Villegas, A., Robbins, M., Gurke, J., Moonen, E. J. M., Schierle, G. S. K., & Malliaras, G. G. (2021) · Advanced Science · doi:10.1002/advs.202004434 · Cited by 73
Boehler, C., Oberueber, F., & Asplund, M. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.05.017 · Cited by 87
Du, Z. J., Luo, X., Weaver, C. L., & Cui, X. T. (2015) · Journal of Materials Chemistry C · doi:10.1039/c5tc00145e · Cited by 76
Moreaux, L. C., Yatsenko, D., Sacher, W. D., Choi, J., Lee, C., Kubat, N. J., Cotton, R. J., Boyden, E. S., Lin, M. Z., Tian, L., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.09.043 · Cited by 75
Chronic intracortical neural recordings using microelectrode arrays coated with PEDOT–TFB
Charkhkar, H., Knaack, G. L., McHail, D. G., Mandal, H. S., Peixoto, N., Rubinson, J. F., Dumas, T. C., & Pancrazio, J. J. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.12.022 · Cited by 68
Regenerative Electrode Interfaces for Neural Prostheses.
Thompson, C. H., Zoratti, M. J., Langhals, N. B., & Purcell, E. K. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0279 · Cited by 67
“71,72 Somewhat paradoxically, it has been observed that the acute-phase production of inflammatory cytokines is increased surrounding smaller devices implanted in the rat brain; further work is needed to understand the relative contributions of gliosis, inflammation, and neuronal loss to recording…”
Self-citationImpedance scaling for gold and platinum microelectrodes
Fan, B., Wolfrum, B. L., & Robinson, J. T. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac20e5 · Cited by 67
Wang, A. Y., Jung, D., Lee, D., & Wang, H. (2021) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.1c00687 · Cited by 69
Zha, F., Chen, W., Hao, L., Wu, C., Lu, M., Zhang, L., & Yu, D. (2020) · Soft Matter · doi:10.1039/d0sm00593b · Cited by 67
Progress in the Field of Micro-Electrocorticography
Shokoueinejad, M., Park, D., Jung, Y. H., Brodnick, S. K., Novello, J., Dingle, A. M., Swanson, K. I., Baek, D.-H., Suminski, A. J., Lake, W. B., et al. (2019) · Micromachines · doi:10.3390/mi10010062 · Cited by 72
“37 MΩ Single unit implanted in layer V (rat) [76] (2011)”
Chen, Y., Pei, W., Chen, S., Wu, X. M., Zhao, S.-S., Wang, H., & Chen, H. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.07.075 · Cited by 68
Ganji, M., Hossain, L., Tanaka, A., Thunemann, M., Halgren, E., Gilja, V., Devor, A., & Dayeh, S. A. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201800923 · Cited by 65
High-stability conducting polymer-based conformal electrodes for bio-/iono-electronics
Yao, B., de Vasconcelos, L. S., Cui, Q., Cardenas, A., Yan, Y., Du, Y., Wu, D., Wu, S., Hsiai, T. K., Lu, N., et al. (2022) · Materials Today · doi:10.1016/j.mattod.2021.12.002 · Cited by 62
Ouyang, L., Kuo, C.-C., Farrell, B., Pathak, S., Wei, B., Qu, J., & Martin, D. C. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00053j · Cited by 57
Organic Electrodes and Communications with Excitable Cells
Harris, A. R., & Wallace, G. G. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700587 · Cited by 61
Patel, P. R., Popov, P., Caldwell, C. M., Welle, E. J., Egert, D., Pettibone, J. R., Roossien, D. H., Becker, J. B., Berke, J. D., Chestek, C. A., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abb1f6 · Cited by 60
Tang, R., Zhang, C., Liu, B., Jiang, C., Wang, L., Zhang, X., Huang, Q., Liu, J., & Li, L. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114600 · Cited by 58
Habib, A., Zhu, X., Can, U. I., McLanahan, M. L., Zorlutuna, P., & Yanik, A. A. (2019) · Science Advances · doi:10.1126/sciadv.aav9786 · Cited by 64
Low-Impedance 3D PEDOT:PSS Ultramicroelectrodes
Jones, P. D., Moskalyuk, A., Barthold, C., Gutöhrlein, K., Heusel, G., Schröppel, B., Samba, R., & Giugliano, M. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00405 · Cited by 58
“While PEDOT coatings previously decreased the impedance of 15-μm-large microelectrodes (Ludwig et al., 2011), here we demonstrate for the first time how PEDOT:PSS coating of 3D ultramicroelectrodes allows a similar final result.”
BackgroundElectrophysiology Read-Out Tools for Brain-on-Chip Biotechnology
Forró, C., Caron, D., Angotzi, G. N., Gallo, V., Berdondini, L., Santoro, F., Palazzolo, G., & Panuccio, G. (2021) · Micromachines · doi:10.3390/mi12020124 · Cited by 57
Aqrawe, Z., Wright, B. E., Patel, N. D., Vyas, Y., Malmström, J., Montgomery, J. M., Williams, D. E., Travaš‐Sejdić, J., & Svirskis, D. M. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.10.099 · Cited by 55
Myomatrix arrays for high-definition muscle recording
Chung, B., Zia, M., Thomas, K. A., Michaels, J. A., Jacob, A., Pack, A. R., Williams, M. J., Nagapudi, K., Teng, L. H., Arrambide, E., et al. (2023) · eLife · doi:10.7554/elife.88551 · Cited by 54
Multi-scale neural decoding and analysis
Lu, H., Lorenc, E. S., Zhu, H., Kilmarx, J., Sulzer, J. S., Xie, C., Tobler, P. N., Watrous, A. J., Orsborn, A. L., Lewis‐Peacock, J. A., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac160f · Cited by 55
Metadata
- Authors
- Ludwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Joseph, Mike D
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-01-19
- Volume
- 8
- Issue
- 1
- Pages
- 014001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC3415981
- OpenAlex
- W1989403232
- Cited by
- 283
- References
- 42
- Citations by year
- 2026: 18 · 2025: 18 · 2024: 9 · 2023: 18 · 2022: 16 · 2021: 23 · 2020: 27 · 2019: 18 · 2018: 24 · 2017: 22 · 2016: 18 · 2015: 32 · 2014: 14 · 2013: 11 · 2012: 9
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- Funders
- National Science Foundation (9986866)
- University of Michigan
- National Institutes of Health
- National Institute of Biomedical Imaging and Bioengineering (P41EB002030)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- PEDOT, neural recording electrodes, electrode impedance, gold electrode, electrode coating, chronic implantation, noise floor, immune response
- MeSH terms
- Animals, Biocompatible Materials, Electrodes, Implanted, Male, Microelectrodes, Motor Cortex, Neurons, Polymers, Rats, Sprague-Dawley, Bridged Bicyclo Compounds, Heterocyclic, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.