CoChat

An automated system for rapid evaluation of high-density electrode arrays in neural prostheses

Open access
John, Sam E, Shivdasani, Mohit N, Leuenberger, James, Fallon, James B, Shepherd, Robert K, Millard, Rodney E, Rathbone, Graeme D, Williams, Chris E · 2011 · Journal of Neural Engineering
Cited by 21

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The success of high-density electrode arrays for use in neural prostheses depends on efficient impedance monitoring and fault detection. Conventional methods of impedance testing and fault detection are time consuming and not always suited for in vivo assessment of high-density electrode arrays. Additionally, the ability to evaluate impedances and faults such as open and short circuits, both in vitro and in vivo, are important to ensure safe and effective stimulation. In this work we describe an automated system for the rapid evaluation of high-density electrode arrays. The system uses a current pulse similar to that used to stimulate neural tissue and measures the voltage across the electrode in order to calculate the impedance. The switching of the system was validated by emulating a high-density electrode array using light-emitting diodes and a resistor-capacitor network. The system was tested in vitro and in vivo using a range of commercially available and in-house developed electrode arrays. The system accurately identified faults in an 84-electrode array in less than 20 s and reliably measured impedances up to 110 kΩ using a 200 µA, 250 µs per phase current pulse. This system has direct application for screening high-density electrode arrays in both clinical and experimental settings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1741-2560/8/3/036011

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 21

Metadata

Authors
John, S. E., Shivdasani, M. N., Leuenberger, J., Fallon, J. B., Shepherd, R. K., Millard, R. E., Rathbone, G. D., & Williams, C. E.
Venue
Journal of Neural Engineering
Published
2011-04-15
Volume
8
Issue
3
Pages
036011
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2007340682
Cited by
21
References
6
FWCI
1.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An automated system for rapid evaluation of high-density electrode arrays in neural prostheses. https://app.cochat.ai/papers/10.1088/1741-2560/8/3/036011
The paper
John, S. E., Shivdasani, M. N., Leuenberger, J., Fallon, J. B., Shepherd, R. K., Millard, R. E., Rathbone, G. D., & Williams, C. E. (2011). An automated system for rapid evaluation of high-density electrode arrays in neural prostheses. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/8/3/036011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.