An automated system for rapid evaluation of high-density electrode arrays in neural prostheses
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The success of high-density electrode arrays for use in neural prostheses depends on efficient impedance monitoring and fault detection. Conventional methods of impedance testing and fault detection are time consuming and not always suited for in vivo assessment of high-density electrode arrays. Additionally, the ability to evaluate impedances and faults such as open and short circuits, both in vitro and in vivo, are important to ensure safe and effective stimulation. In this work we describe an automated system for the rapid evaluation of high-density electrode arrays. The system uses a current pulse similar to that used to stimulate neural tissue and measures the voltage across the electrode in order to calculate the impedance. The switching of the system was validated by emulating a high-density electrode array using light-emitting diodes and a resistor-capacitor network. The system was tested in vitro and in vivo using a range of commercially available and in-house developed electrode arrays. The system accurately identified faults in an 84-electrode array in less than 20 s and reliably measured impedances up to 110 kΩ using a 200 µA, 250 µs per phase current pulse. This system has direct application for screening high-density electrode arrays in both clinical and experimental settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170 · cited 1×
“High-density electrode arrays are being used in neural prostheses in several chronic recording and electrical stimulation applications (Brindley and Lewin 1968, Rizzo et al 2003, Prochazka and Mushahwar 2004, Schwartz 2004, Mccreery et al 2006, Donoghue 2008, Middlebrooks and Snyder 2008).”
MethodSubretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · cited 1×
“High-density electrode arrays are being used in neural prostheses in several chronic recording and electrical stimulation applications (Brindley and Lewin 1968, Rizzo et al 2003, Prochazka and Mushahwar 2004, Schwartz 2004, Mccreery et al 2006, Donoghue 2008, Middlebrooks and Snyder 2008).”
MethodSuner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415
Brummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Cited by
First-in-human trial of a novel suprachoroidal retinal prosthesis
Ayton, L. N., Blamey, P. J., Guymer, R. H., Luu, C. D., Nayagam, D. A. X., Sinclair, N. C., Shivdasani, M. N., Yeoh, J., McCombe, M. F., Briggs, R. J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115239 · Cited by 333
“voltage by the supplied current [34].”
Self-citationCurrent steering in retinal stimulation via a quasimonopolar stimulation paradigm
Matteucci, P. B., Chen, S. C., Tsai, D., Dodds, C. W. D., Dokos, S., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.13-11653 · Cited by 79
“The isolated PXI chassis (PXI-1000B) system included a switch matrix (PXI2532) to redirect the charge-balanced, constant current biphasic pulse,(41) generated by the stimulator, and a digital multimeter (DMM; PXI-4072) to acquire the resulting voltage waveform and determine values for electrode impedance as described…”
MethodVirtual electrodes by current steering in retinal prostheses
Dumm, G., Fallon, J. B., Williams, C. E., & Shivdasani, M. N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-15391 · Cited by 63
Self-citationSpencer, T. C., Fallon, J. B., Thien, P. C., & Shivdasani, M. N. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19325 · Cited by 31
Self-citationA diagnostic circuit for crosstalk detection in microelectrode arrays
McNamara, M., Ersoz, A., & Han, M. (2021) · 2021 10th International IEEE/EMBS Conference on Neural Engineering (NER) · doi:10.1109/ner49283.2021.9441164 · Cited by 5
“Another study used stimulus pulses as test waveforms as done in this study, but could only detect short and open circuits through common reference connections [17].”
Method
Metadata
- Authors
- John, S. E., Shivdasani, M. N., Leuenberger, J., Fallon, J. B., Shepherd, R. K., Millard, R. E., Rathbone, G. D., & Williams, C. E.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-04-15
- Volume
- 8
- Issue
- 3
- Pages
- 036011
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2007340682
- Cited by
- 21
- References
- 6
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An automated system for rapid evaluation of high-density electrode arrays in neural prostheses. https://app.cochat.ai/papers/10.1088/1741-2560/8/3/036011
- The paper
- John, S. E., Shivdasani, M. N., Leuenberger, J., Fallon, J. B., Shepherd, R. K., Millard, R. E., Rathbone, G. D., & Williams, C. E. (2011). An automated system for rapid evaluation of high-density electrode arrays in neural prostheses. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/8/3/036011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.