SSVEP-based Bremen–BCI interface—boosting information transfer rates
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
In recent years, there has been increased interest in using steady-state visual evoked potentials (SSVEP) in brain-computer interface (BCI) systems; the SSVEP approach currently provides the fastest and most reliable communication paradigm for the implementation of a non-invasive BCI. This paper presents recent developments in the signal processing of the SSVEP-based Bremen BCI system, which allowed one of the subjects in an online experiment to reach a peak information transfer rate (ITR) of 124 bit min(-1). It is worth mentioning that this ITR value is higher than all values previously published in the literature for any kind of BCI paradigm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“The ITR calculation leading to the results shown is based on the commonly used formula published in [7].”
BackgroundMethodHerrmann, C. S. (2001) · Experimental Brain Research · doi:10.1007/s002210100682 · Cited by 1,080
Steady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859 · cited 1×
“people with severe motor disabilities [4, 5].”
Toward Brain-Computer Interfacing
(2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.001.0001 · Cited by 785
Bin, G., Gao, X., Yan, Z., Hong, B., & Gao, S. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046002 · Cited by 773 · cited 1×
“In a six target SSVEP-based BCI, an average accuracy of 95.3% and ITR of 58 ± 9.6 bit min − 1 for 12 healthy participants were reported in [18].”
BackgroundInfluentialA Survey of Stimulation Methods Used in SSVEP-Based BCIs
Zhu, D., Bieger, J., Garcia Molina, G., & Aarts, R. M. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/702357 · Cited by 654
A BCI-based environmental controller for the motion-disabled
Gao, X., Xu, D., Cheng, M., & Gao, S. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814449 · Cited by 637 · cited 2×
“This measure depends on three factors: speed, accuracy and number of targets, which can vary from 2 [16] to up to 48 [17].”
BackgroundInfluentialMultiple Channel Detection of Steady-State Visual Evoked Potentials for Brain-Computer Interfaces
Friman, O., Volosyak, I., & Graser, A. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889160 · Cited by 541 · cited 6×
“As shown in [25], the lower bound of the quadratic form on the right-hand side of equation (7) is given by the minimal eigenvalue λ 1 of the matrix ˜ Y T ˜ Y .”
BackgroundMethodInfluentialSelf-citationClinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Mak, J. N., & Wolpaw, J. R. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2035356 · Cited by 509
Brain-Computer Interfaces Based on Visual Evoked Potentials
Wang, Y., Gao, X., Hong, B., Jia, C., & Gao, S. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.923958 · Cited by 423 · cited 1×
“Nowadays, the SSVEP approach provides the fastest and the most reliable communication paradigm for the implementation of a non-invasive BCI system [9–14].”
BackgroundSteady-State VEP-Based Brain-Computer Interface Control in an Immersive 3D Gaming Environment
Lalor, E. C., Kelly, S. P., Finucane, C., Burke, R., Smith, R., Reilly, R. B., & McDarby, G. (2005) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/asp.2005.3156 · Cited by 421
EEG-based communication: improved accuracy by response verification
Wolpaw, J. R., Ramoser, H., McFarland, D. J., & Pfurtscheller, G. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.712231 · Cited by 396 · cited 1×
“transfer rate (ITR), as introduced in [15] and reported in the”
Brain-Computer Interfaces: Applying our Minds to Human-Computer Interaction
(2010) · Human-Computer Interaction Series · doi:10.1007/978-1-84996-272-8 · Cited by 393
BCI demographics: how many (and what kinds of) people can use an SSVEP BCI?
Allison, B., Luth, T., Valbuena, D., Teymourian, A., Volosyak, I., & Graser, A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039495 · Cited by 344
Self-citationHuman Cerebral Activation during Steady-State Visual-Evoked Responses
Pastor, M. A., Artieda, J., Arbizu, J., Valencia, M., & Masdeu, J. C. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-37-11621.2003 · Cited by 324 · cited 1×
“It is possible to obtain an SSVEP response at a large range of frequencies, from 1 to 90 Hz [30]; however, the strongest responses are typically obtained for lower stimulation frequencies around 15 Hz [31].”
BackgroundKübler, A., Furdea, A., Halder, S., Hammer, E. M., Nijboer, F., & Kotchoubey, B. (2009) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2008.04122.x · Cited by 303 · cited 1×
“people with severe motor disabilities [4, 5].”
VEP-based brain-computer interfaces: time, frequency, and code modulations [Research Frontier
Bin, G., Gao, X., Wang, Y., Hong, B., & Gao, S. (2009) · IEEE Computational Intelligence Magazine · doi:10.1109/mci.2009.934562 · Cited by 256
Stimulator selection in SSVEP-based BCI
Wu, Z., Lai, Y., Xia, Y., Wu, D., & Yao, D. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.01.004 · Cited by 192 · cited 1×
“The amplitude and the phase that define an SSVEP response depend on the frequency, intensity and structure of the repetitive visual pattern [29].”
BackgroundBCI Demographics II: How Many (and What Kinds of) People Can Use a High-Frequency SSVEP BCI?
Volosyak, I., Valbuena, D., Luth, T., Malechka, T., & Graser, A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2121919 · Cited by 175
Self-citationAn Introduction to Brain-Computer Interfacing
Kübler, A., & Müller, K.-R. (2007) · Toward Brain-Computer Interfacing · doi:10.7551/mitpress/7493.003.0003 · Cited by 161
Improved signal processing approaches in an offline simulation of a hybrid brain–computer interface
Brunner, C., Allison, B. Z., Krusienski, D. J., Kaiser, V., Müller-Putz, G., Pfurtscheller, G., & Neuper, C. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.02.002 · Cited by 122
Development of a Low-Cost FPGA-Based SSVEP BCI Multimedia Control System
Shyu, K., Lee, P., Lee, M.-H., Lin, M.-H., Lai, R.-J., & Chiu, Y.-J. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2042595 · Cited by 93
Brain–computer interface using water-based electrodes
Volosyak, I., Valbuena, D., Malechka, T., Peuscher, J., & Gräser, A. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/6/066007 · Cited by 82 · cited 2×
“Our recent study [20] presents a new hardware”
ResultSelf-citationEvaluation of the Bremen SSVEP based BCI in real world conditions
Volosyak, I., Cecotti, H., Valbuena, D., & Graser, A. (2009) · 2009 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209543 · Cited by 74 · cited 5×
“Further details about the software design and implementation of this GUI application can be found in [3, 23, 28].”
BackgroundMethodInfluentialSelf-citationAn SSVEP-Based Brain–Computer Interface for the Control of Functional Electrical Stimulation
Gollee, H., Volosyak, I., McLachlan, A. J., Hunt, K. J., & Gräser, A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2043432 · Cited by 74
Self-citationImpact of Frequency Selection on LCD Screens for SSVEP Based Brain-Computer Interfaces
Volosyak, I., Cecotti, H., & Gräser, A. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02478-8_88 · Cited by 57
Self-citationOptimal visual stimuli on LCD screens for SSVEP based brain-computer interfaces
Volosyak, I., Cecotti, H., & Gräser, A. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109329 · Cited by 49 · cited 3×
“For more details regarding a thorough discussion of frequency selection to be generated on the LCD screens, please refer to [26].”
BackgroundResultInfluentialSelf-citationToward BCI Wizard - best BCI approach for each user
Volosyak, I., Guger, C., & Gräser, A. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627390 · Cited by 26
Self-citationSteady-State Visual Evoked Potential Response - Impact of the Time Segment Length
Volosyak, I., Cecotti, H., & Gräser, A. (2010) · Control and Intelligent Systems · doi:10.2316/j.2010.216.680-0145 · Cited by 25 · cited 3×
“Based on our previous work [32], after analysing the distribution of the time segment length for all correct classifications, it was considered that some of the introduced time segment lengths of 750, 1000, 1500, 2000, 3000 and 4000 ms were used very rarely in practice.”
BackgroundMethodResultInfluentialSelf-citationSensor Modalities for Brain-Computer Interfacing
Schalk, G. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02577-8_67 · Cited by 14
sBCI: Fast detection of steady-state visual evoked potentials
Valbuena, D., Volosyak, I., & Gräser, A. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627990 · Cited by 13
Self-citation
Cited by
Brain–Computer Interface Spellers: A Review
Rezeika, A., Benda, M., Stawicki, P., Gembler, F., Saboor, A., & Volosyak, I. (2018) · Brain Sciences · doi:10.3390/brainsci8040057 · Cited by 391
Self-citationA high-ITR SSVEP-based BCI speller
Chen, X., Chen, Z., Gao, S., & Gao, X. (2014) · Brain-Computer Interfaces · doi:10.1080/2326263x.2014.944469 · Cited by 301
Trends in EEG-BCI for daily-life: Requirements for artifact removal
Minguillon, J., Lopez-Gordo, M. A., & Pelayo, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.005 · Cited by 289
EEG-Based Brain-Computer Interfaces: A Thorough Literature Survey
Hwang, H.-J., Kim, S., Choi, S., & Im, C.-H. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2013.780869 · Cited by 257
“Recently, some BCI studies started to introduce SSVEP-based mental spelling systems (Cecotti, 2010; Hwang et al., 2012; Volosyak, 2011).”
BackgroundA Dynamically Optimized SSVEP Brain–Computer Interface (BCI) Speller
Yin, E., Zhou, Z., Jiang, J., Yu, Y., & Hu, D. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2320948 · Cited by 254
Metadata
- Authors
- Volosyak, I.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-05-10
- Volume
- 8
- Issue
- 3
- Pages
- 036020
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2038052881
- Cited by
- 232
- References
- 32
- FWCI
- 9.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.