Selective recovery of fascicular activity in peripheral nerves
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The peripheral nerves of an amputee's residual limb still carry the information required to provide the robust, natural control signals needed to command a dexterous prosthetic limb. However, these signals are mixed in the volume conductor of the body and extracting them is an unmet challenge. A beamforming algorithm was used to leverage the spatial separation of the fascicular sources, recovering mixed pseudo-spontaneous signals with normalized mean squared error of 0.14 ± 0.10 (n = 12) in an animal model. The method was also applied to a human femoral nerve model using computer simulations and recovered all five fascicular-group signals simultaneously with R(2) = 0.7 ± 0.2 at a signal-to-noise ratio of 0 dB. This technique accurately separated peripheral neural signals, potentially providing the voluntary, natural and robust command signals needed for advanced prosthetic limbs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 1×
“Moreover, they can be shaped, as in the flat interface nerve electrode (FINE), to increase the surface area of the nerve [9].”
BackgroundSelf-citationLong-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301 · cited 1×
“Penetrating electrodes have also been employed, such as the Utah Slanted Electrode Array (USEA)[6] and the Longitudinal Intrafascicular Electrode (LIFE) [7].”
MethodDesign of a Multifunctional Anthropomorphic Prosthetic Hand With Extrinsic Actuation
Dalley, S. A., Wiste, T. E., Withrow, T. J., & Goldfarb, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2033113 · Cited by 204
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130 · cited 1×
“This technique allows more electrodes on the surface of the nerve and spreads the fascicles of the nerve apart to improve selectivity [10].”
MethodMicera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
Localization and Recovery of Peripheral Neural Sources With Beamforming Algorithms
Wodlinger, B., & Durand, D. M. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2034072 · Cited by 73
Self-citationMicera, S., Jensen, W., Sepulveda, F., Riso, R. R., & Sinkjaer, T. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930903 · Cited by 58 · cited 2×
“The correlation coefficient was used as a metric of similarity between signals in order to be consistent with previous work [4, 12, 13].”
MethodSpiral nerve cuff electrode for recordings of respiratory output
Sahin, M., Haxhiu, M. A., Durand, D. M., & Dreshaj, I. A. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.1.317 · Cited by 47
Self-citation
Cited by
Tissue-engineered peripheral nerve interfaces
Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701713 · Cited by 96
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63
Update in facial nerve paralysis: tissue engineering and new technologies
Langhals, N. B., Urbanchek, M. G., Ray, A., & Brenner, M. J. (2014) · Current Opinion in Otolaryngology & Head and Neck Surgery · doi:10.1097/moo.0000000000000062 · Cited by 41
Metadata
- Authors
- Wodlinger, B., & Durand, D. M.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-08-09
- Volume
- 8
- Issue
- 5
- Pages
- 056005
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2008510933
- Cited by
- 47
- References
- 10
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective recovery of fascicular activity in peripheral nerves. https://app.cochat.ai/papers/10.1088/1741-2560/8/5/056005
- The paper
- Wodlinger, B., & Durand, D. M. (2011). Selective recovery of fascicular activity in peripheral nerves. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/8/5/056005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.