Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
The hypothesis is that the mechanical mismatch between brain tissue and microelectrodes influences the inflammatory response. Our unique, mechanically adaptive polymer nanocomposite enabled this study within the cerebral cortex of rats. The initial tensile storage modulus of 5 GPa decreases to 12 MPa within 15 min under physiological conditions. The response to the nanocomposite was compared to surface-matched, stiffer implants of traditional wires (411 GPa) coated with the identical polymer substrate and implanted on the contralateral side. Both implants were tethered. Fluorescent immunohistochemistry labeling examined neurons, intermediate filaments, macrophages, microglia and proteoglycans. We demonstrate, for the first time, a system that decouples the mechanical and surface chemistry components of the neural response. The neuronal nuclei density within 100 µm of the device at four weeks post-implantation was greater for the compliant nanocomposite compared to the stiff wire. At eight weeks post-implantation, the neuronal nuclei density around the nanocomposite was maintained, but the density around the wire recovered to match that of the nanocomposite. The glial scar response to the compliant nanocomposite was less vigorous than it was to the stiffer wire. The results suggest that mechanically associated factors such as proteoglycans and intermediate filaments are important modulators of the response of the compliant nanocomposite.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
R: A Language and Environment for Statistical Computing
R Core Team (2025) · doi:10.32614/r.manuals · Cited by 352,181
Matrix elasticity directs stem cell lineage specification
Engler, A. J., Sen, S., Sweeney, H. L., & Discher, D. E. (2006) · Cell · doi:10.1016/j.cell.2006.06.044 · Cited by 13,915
nlme : Linear and nonlinear mixed effects models
DebRoy, S. (2006) · Medical Entomology and Zoology · Cited by 10,009
Microglia: a sensor for pathological events in the CNS
Kreutzberg, G. W. (1996) · Trends in Neurosciences · doi:10.1016/0166-2236(96)10049-7 · Cited by 4,396 · cited 1×
“Microglia and macrophage cells mediate the inflammatory and immune response to minimize bacterial/viral invaders (Kreutzberg 1996).”
BackgroundRegeneration beyond the glial scar
Silver, J., & Miller, J. H. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1326 · Cited by 3,078
Kigerl, K. A., Gensel, J. C., Ankeny, D. P., Alexander, J. K., Donnelly, D. J., & Popovich, P. G. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.3257-09.2009 · Cited by 2,130 · cited 2×
“Differences between IBA1 and ED1 labeling can therefore be attributed to the presence of either resting microglia or a subset of beneficial, “alternatively activated” (M2), macrophages (Kigerl et al., 2009).”
BackgroundLarge-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875 · cited 2×
“…device, considered critical for unit recording, the brain tissue around the NC implants had nearly twice the neuronal density than that around the wire implants at four weeks that may improve recording of single units from neurons located close to the implant at that time period (Buzsáki 2004).”
BackgroundThe glial scar and central nervous system repair
Fawcett, J. W., & Asher, R. A. (1999) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00072-6 · Cited by 1,803
Cellular mechanotransduction: putting all the pieces together again
Ingber, D. E. (2006) · The FASEB Journal · doi:10.1096/fj.05-5424rev · Cited by 1,627
Reactive Astrocytes Protect Tissue and Preserve Function after Spinal Cord Injury
Faulkner, J. R., Herrmann, J. E., Woo, M. J., Tansey, K. E., Doan, N. B., & Sofroniew, M. V. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.3547-03.2004 · Cited by 1,598
Stimuli-Responsive Polymer Nanocomposites Inspired by the Sea Cucumber Dermis
Capadona, J. R., Shanmuganathan, K., Tyler, D. J., Rowan, S. J., & Weder, C. (2008) · Science · doi:10.1126/science.1153307 · Cited by 962
Self-citationUse of cryoprotectant to maintain long-term peptide immunoreactivity and tissue morphology
Watson, R. E., Wiegand, S. J., Clough, R. W., & Hoffman, G. E. (1986) · Peptides · doi:10.1016/0196-9781(86)90076-8 · Cited by 933
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · cited 8×
“These results aligned with previous studies, which reported that the NeuN density was reduced around the implant in conjunction with similar upregulation of identical glial scar factors (Winslow and Tresco 2009, Biran et al 2005, Zhong and Bellamkonda 2007).”
BackgroundMethodResultInfluentialBrain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Neurite branching on deformable substrates
Flanagan, L. A., Ju, Y.-E., Marg, B., Osterfield, M., & Janmey, P. A. (2002) · NeuroReport · doi:10.1097/00001756-200212200-00007 · Cited by 759 · cited 1×
“Notably, the rate of astrocyte and neuron proliferation as well as oligodendrocyte spreading and neuronal branching was influenced by substrate stiffness (Kippert et al 2009, Flanagan et al 2002, Georges et al 2006).”
BackgroundGeorges, P. C., Miller, W. J., Meaney, D. F., Sawyer, E. S., & Janmey, P. A. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.073114 · Cited by 724
Signaling at the Gliovascular Interface
Simard, M., Arcuino, G., Takano, T., Liu, Q. S., & Nedergaard, M. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-27-09254.2003 · Cited by 586 · cited 2×
“Astrocytes have been implicated in several different functions associated with cytoskeletal structure including neurotransmitter maintenance and blood brain barrier function (Simard et al., 2003; Ortinski et al., 2010).”
Background(1993) · Neuroscience Letters · doi:10.1016/0304-3940(93)90359-s · Cited by 574
Selective induction of astrocytic gliosis generates deficits in neuronal inhibition
Ortinski, P. I., Dong, J., Mungenast, A., Yue, C., Takano, H., Watson, D. J., Haydon, P. G., & Coulter, D. A. (2010) · Nature Neuroscience · doi:10.1038/nn.2535 · Cited by 495
McKeon, R. J., Jurynec, M. J., & Buck, C. R. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-24-10778.1999 · Cited by 480 · cited 6×
“Intensity for CSPGs, via labeling for CS56 antibodies (table 1), peaks within 15 μm from the border (figures 5(a)–(f)).”
BackgroundInfluentialMcConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480 · cited 2×
“Our results are consistent with the research showing a sustained response to indwelling implants (Winslow et al 2010, McConnell et al 2009).”
ResultThe role of extracellular matrix in CNS regeneration
Busch, S. A., & Silver, J. (2007) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2006.09.004 · Cited by 468
Capadona, J. R., Van Den Berg, O., Capadona, L. A., Schroeter, M., Rowan, S. J., Tyler, D. J., & Weder, C. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.379 · Cited by 419 · cited 4×
“storage modulus from 5 GPa to 12 MPa within 15 minutes upon exposure to simulated physiological conditions in artificial cerebral spinal fluid (ACSF) at 37°C (Capadona et al., 2007; Capadona et al., 2008; Capadona et al., 2009; Shanmuganathan et al., 2010a, b, 2009).”
BackgroundMethodSelf-citationSubbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368 · cited 2×
“In addition to the effect of substrate stiffness, in silico modeling studies indicate that indwelling electrodes exert forces on local populations of cells (Lee et al., 2005; Subbaroyan et al., 2005; McConnell et al., 2007).”
BackgroundParylene flexible neural probes integrated with microfluidic channels
Takeuchi, S., Ziegler, D., Yoshida, Y., Mabuchi, K., & Suzuki, T. (2005) · Lab on a Chip · doi:10.1039/b417497f · Cited by 364 · cited 1×
“…of magnitude larger than those of the brain, while also introducing different surface chemistries that could confound the tissue–material interaction (Lee et al 2004, Nikles et al 2003, Takeuchi et al 2004, Wester et al 2009, Takeuchi et al 2005) and complicate the interpretation of these results.”
BackgroundBiran, R., Martin, D. C., & Tresco, P. A. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31138 · Cited by 341 · cited 2×
“In vivo studies which focus on the effects of electrode tethering have shown that untethered implants reduce the extent of the glial scar (Biran et al., 2007; Kim et al., 2004; Subbaroyan, 2007).”
BackgroundHorn, K. P., Busch, S. A., Hawthorne, A. L., van Rooijen, N., & Silver, J. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.2488-08.2008 · Cited by 331
Zhong, Y., & Bellamkonda, R. V. (2007) · Brain Research · doi:10.1016/j.brainres.2007.02.024 · Cited by 321
Biomechanical analysis of silicon microelectrode-induced strain in the brain
Lee, H., Bellamkonda, R. V., Sun, W., & Levenston, M. E. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/003 · Cited by 281 · cited 1×
“In addition to the effect of substrate stiffness, in silico modeling studies indicate that indwelling electrodes exert forces on local populations of cells (Lee et al 2005, Subbaroyan et al 2005, McConnell et al 2007).”
BackgroundLiu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788468 · Cited by 271
Polymer Nanocomposites with Nanowhiskers Isolated from Microcrystalline Cellulose
Capadona, J. R., Shanmuganathan, K., Trittschuh, S., Seidel, S., Rowan, S. J., & Weder, C. (2009) · Biomacromolecules · doi:10.1021/bm8010903 · Cited by 245
Self-citationMyosin II and mechanotransduction: a balancing act
Clark, K., Langeslag, M., Figdor, C. G., & van Leeuwen, F. N. (2007) · Trends in Cell Biology · doi:10.1016/j.tcb.2007.02.002 · Cited by 230 · cited 2×
“Despite increasing evidence for the importance of cellular mechanotransduction in tissue repair and homeostasis (Clark et al 2007, Ingber 2006), the role of mechanical mismatch has not been fully elucidated in an in vivo study to explain the interplay of chemical and mechanical factors that…”
Background3D flexible multichannel neural probe array
Takeuchi, S., Suzuki, T., Mabuchi, K., & Fujita, H. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/1/014 · Cited by 219 · cited 2×
“…of magnitude larger than those of the brain, while also introducing different surface chemistries that could confound the tissue–material interaction (Lee et al 2004, Nikles et al 2003, Takeuchi et al 2004, Wester et al 2009, Takeuchi et al 2005) and complicate the interpretation of these results.”
BackgroundChronic response of adult rat brain tissue to implants anchored to the skull
Kim, Y.-T., Hitchcock, R. W., Bridge, M. J., & Tresco, P. A. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.010 · Cited by 213
Biomimetic mechanically adaptive nanocomposites
Shanmuganathan, K., Capadona, J. R., Rowan, S. J., & Weder, C. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.10.005 · Cited by 209
Self-citationLu, Y., Wang, D., Li, T., Zhao, X., Cao, Y., Yang, H., & Duan, Y. Y. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.030 · Cited by 208
Diffusion barriers evoked in the rat cortex by reactive astrogliosis
Roitbak, T., & Sykov�, E. (1999) · Glia · doi:10.1002/(sici)1098-1136(199910)28:1<40::aid-glia5>3.0.co;2-6 · Cited by 207 · cited 1×
“Detrimental to neural protection, astrocytes have been implicated as a diffusion barrier (Roitbak and Sykova 1999), remyelination limiter (Fawcett and Asher 1999) and producer of cytokines and ECM components such as fibronectin (Shearer et al 2003) and CSPGs (McKeon et al 1999).”
BackgroundWinslow, B. D., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.049 · Cited by 178
Busch, S. A., Horn, K. P., Cuascut, F. X., Hawthorne, A. L., Bai, L., Miller, R. H., & Silver, J. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.3705-09.2010 · Cited by 177
Self-citationAlonso, G. (2005) · Glia · doi:10.1002/glia.20121 · Cited by 177 · cited 2×
“Likewise, NG2+ cells that express vimentin have been proposed to support repair of central nervous system damage and stabilize axons in response to dieback from ED1+ cells (Alonso 2005, Nishiyama 2007, Busch et al 2010).”
BackgroundWinslow, B. D., Christensen, M. B., Yang, W.-K., Solzbacher, F., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.050 · Cited by 171
Cullen, D. K., Simon, C. M., & LaPlaca, M. C. (2007) · Brain Research · doi:10.1016/j.brainres.2007.04.070 · Cited by 167
Nisbet, D. R., Rodda, A. E., Horne, M. K., Forsythe, J. S., & Finkelstein, D. I. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.011 · Cited by 164
Polydendrocytes: NG2 Cells with Many Roles in Development and Repair of the CNS
Nishiyama, A. (2007) · The Neuroscientist · doi:10.1177/1073858406295586 · Cited by 162 · cited 1×
“Likewise, NG2+ cells that express vimentin have been proposed to support repair of central nervous system damage and stabilize axons in response to dieback from ED1+ cells (Alonso 2005, Nishiyama 2007, Busch et al 2010).”
BackgroundStimuli-Responsive Mechanically Adaptive Polymer Nanocomposites
Shanmuganathan, K., Capadona, J. R., Rowan, S. J., & Weder, C. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am9006337 · Cited by 160
Self-citationBio-inspired mechanically-adaptive nanocomposites derived from cotton cellulose whiskers
Shanmuganathan, K., Capadona, J. R., Rowan, S. J., & Weder, C. (2010) · J. Mater. Chem. · doi:10.1039/b916130a · Cited by 159
Self-citationIn vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes
Harris, J. P., Hess, A. E., Rowan, S. J., Weder, C., Zorman, C. A., Tyler, D. J., & Capadona, J. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046010 · Cited by 151 · cited 6×
“Both implant types were single shank probes with nearly the same cross-sectional area, refer to Harris et al 2011 for a characterization of implant mechanical properties of the NC material.”
BackgroundMethodSelf-citationShearer, M. C., Niclou, S. P., Brown, D., Asher, R. A., Holtmaat, A. J. G. D., Levine, J. M., Verhaagen, J., & Fawcett, J. W. (2003) · Molecular and Cellular Neuroscience · doi:10.1016/j.mcn.2003.09.004 · Cited by 107
Mechanosensation and endothelin in astrocytes—hypothetical roles in CNS pathophysiology
Ostrow, L. W., & Sachs, F. (2004) · Brain Research Reviews · doi:10.1016/j.brainresrev.2004.09.005 · Cited by 103 · cited 1×
“Cultured astrocytes have been shown to respond to mechanical stimuli via calcium signaling (Ostrow and Sachs 2005).”
BackgroundLevin, E. C., Acharya, N. K., Sedeyn, J. C., Venkataraman, V., D’Andrea, M. R., Wang, H.-Y., & Nagele, R. G. (2009) · Brain Research · doi:10.1016/j.brainres.2009.08.072 · Cited by 100
Wester, B. A., Lee, R. H., & LaPlaca, M. C. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/024002 · Cited by 91
Biocompatible benzocyclobutene (BCB)-based neural implants with micro-fluidic channel
Lee, K., He, J., Clement, R. S., Massia, S. P., & Kim, B. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.02.005 · Cited by 83 · cited 1×
“…of magnitude larger than those of the brain, while also introducing different surface chemistries that could confound the tissue–material interaction (Lee et al 2004, Nikles et al 2003, Takeuchi et al 2004, Wester et al 2009, Takeuchi et al 2005) and complicate the interpretation of these results.”
BackgroundFujita, T., Yoshimine, T., Maruno, M., & Hayakawa, T. (1998) · Acta Neurochirurgica · doi:10.1007/s007010050095 · Cited by 65 · cited 4×
“Aligning with previous research (Fujita et al 1998, Nisbet et al 2009), both implant types appear to lower ED1 activation from four to eight weeks (figures 8(a)–(f)) suggesting an ongoing reaction that lessens over time.”
BackgroundMethodInfluentialActomyosin contractility controls cell surface area of oligodendrocytes
Kippert, A., Fitzner, D., Helenius, J. H., & Simons, M. (2009) · BMC Cell Biology · doi:10.1186/1471-2121-10-71 · Cited by 63 · cited 2×
“Notably, the rate of astrocyte and neuron proliferation as well as oligodendrocyte spreading and neuronal branching were influenced by substrate stiffness (Kippert et al., 2009; Flanagan et al., 2002; Georges et al., 2006).”
BackgroundMcConnell, G. C., Schneider, T. M., Owens, D. J., & Bellamkonda, R. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895373 · Cited by 53
Effects of Glial Cells on Electrode Impedance Recorded from Neural Prosthetic Devices In Vitro
Frampton, J. P., Hynd, M. R., Shuler, M. L., & Shain, W. G. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9911-y · Cited by 46
Castellano, B., & Nieto‐Sampedro, M. (2003) · Cited by 17
Long term in vitro monitoring of polyimide microprobe electrical properties
Nikles, S. A., Pellinen, D. S., Kitagawa, J., Bradley, R. M., Kipke, D. R., & Najafi, K. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280860 · Cited by 14 · cited 2×
“…of magnitude larger than those of the brain, while also introducing different surface chemistries that could confound the tissue–material interaction (Lee et al 2004, Nikles et al 2003, Takeuchi et al 2004, Wester et al 2009, Takeuchi et al 2005) and complicate the interpretation of these results.”
Background
Cited by
Nanocellulose, a tiny fiber with huge applications
Abitbol, T., Rivkin, A., Cao, Y., Nevo, Y., Abraham, E., Ben-Shalom, T., Lapidot, S., & Shoseyov, O. (2016) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2016.01.002 · Cited by 1,006
Recent advances in nanocellulose for biomedical applications
Jorfi, M., & Foster, E. J. (2015) · Journal of Applied Polymer Science · doi:10.1002/app.41719 · Cited by 738
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
“Examples are mechanically compliant nanoparticle polymer substrates for stimuli-responsive designs inspired by the sea cucumber dermis 161,163,166–168 (Fig.”
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Metadata
- Authors
- Harris, J. P., Capadona, J. R., Miller, R. H., Healy, B. C., Shanmuganathan, K., Rowan, S. J., Weder, C., & Tyler, D. J.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-10-01
- Volume
- 8
- Issue
- 6
- Pages
- 066011
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2036816539
- Cited by
- 190
- References
- 58
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.