A response surface model predicting the in vivo insertion behavior of micromachined neural implants
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The mechanical damage caused by the insertion of a foreign body into living tissue is inevitable, especially when a considerable stiffness mismatch is present, as in the case of micromachined neural implants and brain tissue. However, the response surface model based on a central composite experimental design described in this study showed that for particular configurations of the implant tip angle, width, thickness or insertion speed, some of these factors could be safely increased without causing an unwanted significant force or tissue dimpling increase. The model covers chisel tip angles between 10° and 50°, implant widths within the 200-400 µm range and thicknesses between 50 and 150 µm. The insertion speed has been varied from 10 up to 100 µm s(-1) to reach a final insertion depth of 6 mm. Coating the implant with parylene C proved to be beneficial in reducing the friction between the implant and the surrounding tissue. Successfully validated for a particular implant geometry, this model could be used as an insertion behavior prediction tool for the design optimization of future neural implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter
Chae, M. S., Yang, Z., Yuce, M. R., Hoang, L., & Liu, W. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021607 · Cited by 369 · cited 1×
“Significant advances have been made toward complex micromachined system integration [1–5], active circuit integration [6–9] and data acquisition [10–12].”
BackgroundCell and protein compatibility of parylene-C surfaces
Chang, T. Y., Yadav, V. G., De Leo, S., Mohedas, A., Rajalingam, B., Chen, C.-L., Selvarasah, S., Dokmeci, M. R., & Khademhosseini, A. (2007) · Langmuir · doi:10.1021/la7017049 · Cited by 320
Richardson, R. T., Thompson, B., Moulton, S., Newbold, C., Lum, M. G., Cameron, A., Wallace, G., Kapsa, R., Clark, G., & O’Leary, S. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.09.008 · Cited by 251
A three-dimensional neural recording microsystem with implantable data compression circuitry
Olsson, R. H., & Wise, K. D. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.858479 · Cited by 245
256-Channel Neural Recording and Delta Compression Microsystem With 3D Electrodes
Aziz, J. N. Y., Abdelhalim, K., Shulyzki, R., Genov, R., Bardakjian, B. L., Derchansky, M., Serletis, D., & Carlen, P. L. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2010997 · Cited by 184
In Vivo Penetration Mechanics and Mechanical Properties of Mouse Brain Tissue at Micrometer Scales
Sharp, A. A., Ortega, A. M., Restrepo, D., Curran-Everett, D., & Gall, K. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2003261 · Cited by 157 · cited 8×
“For insertion speeds higher than 100 μm s−1, the force increase with depth has been approximated in the literature as linear and the cutting component of the insertion force has been calculated by subtracting from it the drag force value considered to account only for friction [33].”
BackgroundResultInfluentialStrength characterization of silicon microprobes in neurophysiological tissues
Najafi, K., & Hetke, J. F. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55638 · Cited by 146 · cited 3×
“According to Najafi and Hetke [35], the force required to buckle the narrowest and thinnest of our devices (W = 200 μm, T = 50 μm) is around 70 mN, one order of magnitude higher than the insertion forces we observed in previous experiments [34].”
BackgroundResultRecent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
Toward a self-deploying shape memory polymer neuronal electrode
Sharp, A. A., Panchawagh, H. V., Ortega, A., Artale, R., Richardson-Burns, S., Finch, D. S., Gall, K., Mahajan, R. L., & Restrepo, D. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/l02 · Cited by 113
Cited by
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
“et al [105, 106] 10 100 Silicon Single shaft [200–400] ×[50 − 150] 10–50 6”
BackgroundInfluentialA Neural Probe With Up to 966 Electrodes and Up to 384 Configurable Channels in 0.13 $\mu$m SOI CMOS
Mora Lopez, C., Putzeys, J., Raducanu, B. C., Ballini, M., Wang, S., Andrei, A., Rochus, V., Vandebriel, R., Severi, S., Van Hoof, C., et al. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2646901 · Cited by 201
“3◦, a geometry targeting low tissue damage [25].”
BackgroundSelf-citationFlexible, Penetrating Brain Probes Enabled by Advances in Polymer Microfabrication
Weltman, A., Yoo, J., & Meng, E. (2016) · Micromachines · doi:10.3390/mi7100180 · Cited by 184
“According to another study, minimizing the width of a silicon probe was one of the most influential factors in reducing the end forces experienced by the probe after it was placed in its target location [121].”
BackgroundMethodInfluentialAbiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178
“ORIGINAL RESEARCH ARTICLE published: 04 February 2014 doi: 10.3389/fneng.2014.00002 Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants”
BackgroundInfluential
Metadata
- Authors
- Andrei, A., Welkenhuysen, M., Nuttin, B., & Eberle, W.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-12-13
- Volume
- 9
- Issue
- 1
- Pages
- 016005
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2022728113
- Cited by
- 58
- References
- 10
- FWCI
- 0.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A response surface model predicting the in vivo insertion behavior of micromachined neural implants. https://app.cochat.ai/papers/10.1088/1741-2560/9/1/016005
- The paper
- Andrei, A., Welkenhuysen, M., Nuttin, B., & Eberle, W. (2012). A response surface model predicting the in vivo insertion behavior of micromachined neural implants. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/9/1/016005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.