Accurate decoding of reaching movements from field potentials in the absence of spikes
Open accessThe DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Abstract
The recent explosion of interest in brain-machine interfaces (BMIs) has spurred research into choosing the optimal input signal source for a desired application. The signals with highest bandwidth--single neuron action potentials or spikes--typically are difficult to record for more than a few years after implantation of intracortical electrodes. Fortunately, field potentials recorded within the cortex (local field potentials, LFPs), at its surface (electrocorticograms, ECoG) and at the dural surface (epidural, EFPs) have also been shown to contain significant information about movement. However, the relative performance of these signals has not yet been directly compared. Furthermore, while it is widely postulated, it has not yet been demonstrated that these field potential signals are more durable than spike recordings. The aim of this study was to address both of these questions. We assessed the offline decoding performance of EFPs, LFPs and spikes, recorded sequentially, in primary motor cortex (M1) in terms of their ability to decode the target of reaching movements, as well as the endpoint trajectory. We also examined the decoding performance of LFPs on electrodes that are not recording spikes, compared with the performance when they did record spikes. Spikes were still present on some of the other electrodes throughout this study. We showed that LFPs performed nearly as well as spikes in decoding velocity, and slightly worse in decoding position and in target classification. EFP performance was slightly inferior to that reported for ECoG in humans. We also provided evidence demonstrating that movement-related information in the LFP remains high regardless of the ability to record spikes concurrently on the same electrodes. This is the first study to provide evidence that LFPs retain information about movement in the absence of spikes on the same electrodes. These results suggest that LFPs may indeed remain informative after spike recordings are lost, thereby providing a robust, accurate signal source for BMIs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“Movement-related information derived from spikes in the motor cortex (M1) has been used to control brain–machine interfaces (BMIs) that allow users to move a computer cursor [1–4] or a robotic arm [5], or to reanimate paralyzed muscles via functional electrical stimulation (FES [6–8]).”
MethodNunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Electric Fields of the Brain: The Neurophysics of EEG
Nunez, P. L., & Harth, E. (1982) · Physics Today · doi:10.1063/1.2915137 · Cited by 2,232
Synaptic mechanisms of synchronized gamma oscillations in inhibitory interneuron networks
Bartos, M., Vida, I., & Jonas, P. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2044 · Cited by 2,070 · cited 1×
“The current understanding is that LFPs originate from post-synaptic potentials [14, 55] and local processing activity [56, 57].”
BackgroundLearning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 1×
“1741-2560/12/046006+13$33.00 1 © 2012 IOP Publishing Ltd Printed in the UK & the USA”
InfluentialMitzdorf, U. (1985) · Physiological Reviews · doi:10.1152/physrev.1985.65.1.37 · Cited by 1,673 · cited 1×
“The current understanding is that LFPs originate from post-synaptic potentials [14, 55] and local processing activity [56, 57].”
BackgroundCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540 · cited 1×
“1741-2560/12/046006+13$33.00 1 © 2012 IOP Publishing Ltd Printed in the UK & the USA”
InfluentialReal-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409 · cited 1×
“1741-2560/12/046006+13$33.00 1 © 2012 IOP Publishing Ltd Printed in the UK & the USA”
Influential
Cited by
Brain–machine interfaces in neurorehabilitation of stroke
Soekadar, S. R., Birbaumer, N., Slutzky, M. W., & Cohen, L. G. (2015) · Neurobiology of Disease · doi:10.1016/j.nbd.2014.11.025 · Cited by 335
Self-citationPerge, J. A., Homer, M. L., Malik, W. Q., Cash, S., Eskandar, E., Friehs, G., Donoghue, J. P., & Hochberg, L. R. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036004 · Cited by 243
Zhou, A., Santacruz, S. R., Johnson, B. C., Alexandrov, G., Moin, A., Burghardt, F. L., Rabaey, J. M., Carmena, J. M., & Muller, R. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0323-x · Cited by 233
Mugler, E. M., Patton, J. L., Flint, R. D., Wright, Z. A., Schuele, S. U., Rosenow, J., Shih, J. J., Krusienski, D. J., & Slutzky, M. W. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035015 · Cited by 192
Self-citationFlint, R. D., Wright, Z. A., Scheid, M. R., & Slutzky, M. W. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056005 · Cited by 183
“Furthermore, LFPbased movement decoding remains accurate in the absence of spiking activity at the same electrode [18, 21], suggesting that LFPs may exhibit better longevity than single units.”
BackgroundMethodInfluentialSelf-citationSensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
“For example, the ability to detect a spike might be susceptible to array micromotions, whereas the aggregate nature of LFPs may mitigate signal changes due to tiny array movements because of their volume conduction properties.”
InfluentialPower-saving design opportunities for wireless intracortical brain–computer interfaces
Even-Chen, N., Muratore, D. G., Stavisky, S. D., Hochberg, L. R., Henderson, J. M., Murmann, B., & Shenoy, K. V. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0595-9 · Cited by 118
“The local field potentials contain less information about the intended movement (such as movement velocity) compared to spikes; they are beneficial for continuous iBCI control mostly when the spike signals have degraded severely 8,12,26,60,61 or to distinguish a small set of discrete states 62 .”
BackgroundNason, S. R., Vaskov, A. K., Willsey, M. S., Welle, E. J., An, H., Vu, P. P., Bullard, A. J., Nu, C. S., Kao, J. C., Shenoy, K. V., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0591-0 · Cited by 113
Christie, B. P., Tat, D. M., Irwin, Z. T., Gilja, V., Nuyujukian, P., Foster, J. D., Ryu, S. I., Shenoy, K. V., Thompson, D. E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016009 · Cited by 103
Mugler, E. M., Tate, M. C., Livescu, K., Templer, J. W., Goldrick, M. A., & Slutzky, M. W. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.1206-18.2018 · Cited by 96
Self-citationRobust and accurate decoding of hand kinematics from entire spiking activity using deep learning
Ahmadi, N., Constandinou, T. G., & Bouganis, C.-S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abde8a · Cited by 69
“Many BMI studies employ linear decoders, e.g. Wiener filter (WF)5, 40, 41 and Kalman filter (KF),6, 9, 21, 32, 33, 42 which could yield suboptimal decoding accuracy as neural signals are known to exhibit nonlinear and nonstationary properties.43 Although there exists a nonlinear extension of WF and KF, called Wiener c…”
BackgroundResultInfluentialReal-time estimation and biofeedback of single-neuron firing rates using local field potentials
Hall, T. M., Nazarpour, K., & Jackson, A. (2014) · Nature Communications · doi:10.1038/ncomms6462 · Cited by 61
“…the summation of postsynaptic potentials over at least a few hundred micrometres from the recording site 10-15 , LFPs may be less sensitive to micro-movements and encapsulation of electrodes 16,17 and kinematic information can be retrieved even from electrodes without clear spike activity 18,19 .”
High-density mapping of primate digit representations with a 1152-channel µECoG array
Kaiju, T., Inoue, M., Hirata, M., & Suzuki, T. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abe245 · Cited by 42
“However, an ECoG electrode array cannot directly measure the single-unit activities of individual neurons, and its decoding ability is less than that of the invasive penetrating electrodes [10].”
BackgroundSpectral distribution of local field potential responses to electrical stimulation of the retina
Wong, Y. T., Halupka, K., Kameneva, T., Cloherty, S. L., Grayden, D. B., Burkitt, A. N., Meffin, H., & Shivdasani, M. N. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036003 · Cited by 16
Metadata
- Authors
- Flint, R. D., Lindberg, E. W., Jordan, L. R., Miller, L. E., & Slutzky, M. W.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2012-06-25
- Volume
- 9
- Issue
- 4
- Pages
- 046006
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1964491684
- Cited by
- 201
- References
- 67
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.