The effect of pore size on tissue ingrowth and neovascularization in porous bioceramics of controlled architecture in vivo
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to investigate the role of pore size on tissue ingrowth and neovascularization in porous bioceramics under the accurate control of the pore parameters. For that purpose, β-tricalcium phosphate (β-TCP) cylinders with four different macropore sizes (300-400, 400-500, 500-600 and 600-700 µm) but the same interconnection size (120 µm) and unchangeable porosity were implanted into fascia lumbodorsalis in rabbits. The fibrous tissues and blood vessels formed in scaffolds were observed histologically and histomorphometrically. The vascularization of the porous bioceramics was analyzed by single-photon emission computed tomography (SPECT). It is found that pore size as an important parameter of a porous structure plays an important role in tissue infiltration into porous biomaterial scaffolds. The amount of fibrous tissue ingrowth increases with the decrease of the pore size. In four kinds of scaffolds with different macropore sizes (300-400, 400-500, 500-600 and 600-700 µm) and a constant interconnection size of 120 µm, the areas of fibrous tissue (%) were 60.5%, 52.2%, 41.3% and 37.3%, respectively, representing a significant decrease at 4 weeks (P < 0.01). The pore size of a scaffold is closely related to neovascularization of macroporous biomaterials implanted in vivo. A large pore size is beneficial for the growth of blood vessels, and the diameter of a pore smaller than 400 µm limits the growth of blood vessels and results in a smaller blood vessel diameter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Porosity of 3D biomaterial scaffolds and osteogenesis
Karageorgiou, V., & Kaplan, D. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.002 · Cited by 6,622 · cited 3×
“However, the effect of the stimulation of an angiogenic response in transplants is limited without an appropriate porous structure for blood vessel formation in the scaffold [6, 10, 32, 40].”
BackgroundPolymeric system for dual growth factor delivery
Richardson, T. P., Peters, M. C., Ennett, A. B., & Mooney, D. J. (2001) · Nature Biotechnology · doi:10.1038/nbt1101-1029 · Cited by 1,752
Osteoconduction at porous hydroxyapatite with various pore configurations
Chang, B.-S., Lee, >. K. >.-K., Hong, K.-S., Youn, H.-J., Ryu, H.-S., Chung, S.-S., & Park, K.-W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00030-2 · Cited by 635
Gauthier, O., Bouler, J.-M., Aguado, E., Pilet, P., & Daculsi, G. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00180-4 · Cited by 614
EGGLI, P. S., MOLLER, W., & SCHENK, R. K. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198807000-00017 · Cited by 559 · cited 2×
“In contrast to the conclusion, some researchers observed a faster bone ingrowth with small pores [30, 31].”
BackgroundResultMechanical and in vivo performance of hydroxyapatite implants with controlled architectures
Chu, T.-M. G., Orton, D. G., Hollister, S. J., Feinberg, S. E., & Halloran, J. W. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00243-5 · Cited by 554
Zisch, A. H., Lutolf, M. P., Ehrbar, M., Raeber, G. P., Rizzi, S. C., Davies, N., Schmökel, H., Bezuidenhout, D., Djonov, V., Zilla, P., et al. (2003) · The FASEB Journal · doi:10.1096/fj.02-1041fje · Cited by 534
The effect of geometry on three-dimensional tissue growth
Rumpler, M., Woesz, A., Dunlop, J. W. C., van Dongen, J. T., & Fratzl, P. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0064 · Cited by 531 · cited 1×
“Moreover, some researchers have observed the higher cell proliferation rate and local growth rate of tissues in smaller pores due to larger local curvature [6, 7].”
BackgroundRole of interconnections in porous bioceramics on bone recolonization in vitro and in vivo
LU, J. X., FLAUTRE, B., ANSELME, K., HARDOUIN, P., GALLUR, A., DESCAMPS, M., & THIERRY, B. (1999) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1008973120918 · Cited by 530 · cited 2×
“Generally, it is accepted that the pore size and interconnection must be larger than 50–100 μm to enable blood vessel ingrowth and hence cell invasion, as well as enhanced biological response [10, 13, 14, 20].”
BackgroundPark, S.-N., Park, J.-C., Kim, H. O., Song, M. J., & Suh, H. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00235-6 · Cited by 511
Mastrogiacomo, M., Scaglione, S., Martinetti, R., Dolcini, L., Beltrame, F., Cancedda, R., & Quarto, R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.031 · Cited by 509
Kuboki, Y., Jin, Q., & Takita, H. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200100002-00005 · Cited by 433 · cited 1×
“However, the effect of the stimulation of an angiogenic response in transplants is limited without an appropriate porous structure for blood vessel formation in the scaffold [6, 10, 32, 40].”
BackgroundBiopolymeric delivery matrices for angiogenic growth factors
Zisch, A. H., Lutolf, M. P., & Hubbell, J. A. (2003) · Cardiovascular Pathology · doi:10.1016/s1054-8807(03)00089-9 · Cited by 357
Pore Morphology Effects on the Fibrovascular Tissue Growth in Porous Polymer Substrates
Wake, M. C., Patrick, C. W., & Mikos, A. G. (1994) · Cell Transplantation · doi:10.1177/096368979400300411 · Cited by 315
Roy, T. D., Simon, J. L., Ricci, J. L., Rekow, E. D., Thompson, V. P., & Parsons, J. R. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10582 · Cited by 262
Vascularized Bone Autografts: Experience with 41 Cases
WEILAND, A. J., MOORE, J. R., & DANIEL, R. K. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198304000-00012 · Cited by 258
Effect of surface finish on the osseointegration of laser-treated titanium alloy implants
Götz, H. E., Müller, M., Emmel, A., Holzwarth, U., Erben, R. G., & Stangl, R. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.002 · Cited by 240
Takahashi, Y., & Tabata, Y. (2004) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856204322752228 · Cited by 215
Comparative study of porous hydroxyapatite and tricalcium phosphate as bone substitute
Shimazaki, K., & Mooney, V. (1985) · Journal of Orthopaedic Research · doi:10.1002/jor.1100030306 · Cited by 199
Porous calcium polyphosphate scaffolds for bone substitute applications in vivo studies
Grynpas, M. D., Pilliar, R. M., Kandel, R. A., Renlund, R., Filiaggi, M., & Dumitriu, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00336-2 · Cited by 191
Vascularized bone autografts. Experience with 41 cases.
Weiland, A. J., Moore, J., & Daniel, R. K. (1983) · PubMed · Cited by 190
Effects of geometry of hydroxyapatite as a cell substratum in BMP-induced ectopic bone formation
Jin, Q.-M., Takita, H., Kohgo, T., Atsumi, K., Itoh, H., & Kuboki, Y. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20000905)51:3<491::aid-jbm25>3.0.co;2-1 · Cited by 170
Rose, F. R. A. J., Cyster, L. A., Grant, D. M., Scotchford, C. A., Howdle, S. M., & Shakesheff, K. M. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.012 · Cited by 167
A paradigm shift: biomaterials that heal
Ratner, B. D. (2007) · Polymer International · doi:10.1002/pi.2319 · Cited by 162 · cited 1×
“In Ratner’s research [33, 34], porous structures can be controlled accurately with sphere-templating techniques.”
BackgroundMoore, M. J., Jabbari, E., Ritman, E. L., Lu, L., Currier, B. L., Windebank, A. J., & Yaszemski, M. J. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30138 · Cited by 161
Kuboki, Y., Jin, Q., Kikuchi, M., Mamood, J., & Takita, H. (2002) · Connective Tissue Research · doi:10.1080/03008200290001104 · Cited by 145
Effect of scaffold architecture and pore size on smooth muscle cell growth
Lee, M., Wu, B. M., & Dunn, J. C. Y. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31816 · Cited by 141
Charrière, E., Lemaître, J., & Zysset, P. K. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00406-4 · Cited by 132
Locally Enhanced Angiogenesis Promotes Transplanted Cell Survival
Smith, M. K., Peters, M. C., Richardson, T. P., Garbern, J. C., & Mooney, D. J. (2004) · Tissue Engineering · doi:10.1089/107632704322791709 · Cited by 131
New macroporous calcium phosphate glass ceramic for guided bone regeneration
Navarro, M., del Valle, S., Martı́nez, S., Zeppetelli, S., Ambrosio, L., Planell, J. A., & Ginebra, M. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.012 · Cited by 129
Bioresorbable polymers in trauma and bone surgery.
Gogolewski, S. (2000) · Injury · doi:10.1016/s0020-1383(00)80020-0 · Cited by 126
Composition Options for Tissue-Engineered Bone
Orban, J. M., Marra, K. G., & Hollinger, J. O. (2002) · Tissue Engineering · doi:10.1089/107632702760240454 · Cited by 118
Cartmell, S. H., Huynh, K. A., Lin, A., Nagaraja, S., & Guldberg, R. E. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20118 · Cited by 113
Dawson, J. I., Wahl, D. A., Lanham, S. A., Kanczler, J. M., Czernuszka, J. T., & Oreffo, R. O. C. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.040 · Cited by 101
The dosage dependence of VEGF stimulation on scaffold neovascularisation
Davies, N. H., Dobner, S., Bezuidenhout, D., Schmidt, C. A., Beck, M., Zisch, A. H., & Zilla, P. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.007 · Cited by 96
Localized Angiogenesis Induced by Human Vascular Endothelial Growth Factor-Activated PLGA Sponge
Elçin, A. E., & Elçin, Y. M. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.959 · Cited by 69
Quantitative characterization of sphere‐templated porous biomaterials
Marshall, A. J., & Ratner, B. D. (2005) · AIChE Journal · doi:10.1002/aic.10390 · Cited by 63
HENRY, J., Burugapalli, K., Neuenschwander, P., & Pandit, A. S. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.08.020 · Cited by 55
Tools for tissue engineering of mineralized oral structures
Dard, M., Sewing, A., Meyer, J., Verrier, S., Roessler, S., & Scharnweber, D. (2000) · Clinical Oral Investigations · doi:10.1007/s007840050128 · Cited by 50
Dynamics of Fibrovascular Tissue Ingrowth in Hydrogel Foams
Wake, M. C., Mikos, A. G., Sarakinos, G., Vacanti, J. P., & Langer, R. (1995) · Cell Transplantation · doi:10.1016/0963-6897(95)00003-g · Cited by 33
Effect of 3D‐microstructure of bioabsorbable PGA:TMC scaffolds on the growth of chondrogenic cells
Mukherjee, D. P., Smith, D. F., Rogers, S. H., Emmanual, J. E., Jadin, K. D., & Hayes, B. K. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31155 · Cited by 31
In vivo absorption of porous apatite- and wollastonite-containing glass-ceramic
Ohsawa, K., Neo, M., Okamoto, T., Tamura, J., & Nakamura, T. (2004) · Journal of Materials Science Materials in Medicine · doi:10.1023/b:jmsm.0000036273.37843.0c · Cited by 23
Cited by
Bone tissue regeneration: the role of scaffold geometry
Zadpoor, A. A. (2015) · Biomaterials Science · doi:10.1039/c4bm00291a · Cited by 518
Role of pore size and morphology in musculo-skeletal tissue regeneration
Perez, R. A., & Mestres, G. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.12.087 · Cited by 468
Zhao, D., Zhang, F., Wang, B., Liu, B., Li, L., Kim, S.-Y., Goodman, S. B., Hernigou, P., Cui, Q., Lineaweaver, W. C., et al. (2020) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2019.12.004 · Cited by 441
Amani, H., Arzaghi, H., Bayandori, M., Dezfuli, A. S., Pazoki‐Toroudi, H., Shafiee, A., & Moradi, L. (2019) · Advanced Materials Interfaces · doi:10.1002/admi.201900572 · Cited by 436
Calcium phosphate cements for bone engineering and their biological properties
Xu, H. H., Wang, P., Wang, L., Bao, C., Chen, Q., Weir, M. D., Chow, L. C., Zhao, L., Zhou, X., & Reynolds, M. A. (2017) · Bone Research · doi:10.1038/boneres.2017.56 · Cited by 409
Metadata
- Authors
- Feng, B., Jinkang, Z., Zhen, W., Jianxi, L., Jiang, C., Jian, L., Guolin, M., & Xin, D.
- Venue
- Biomedical Materials
- Publisher
- IOP Publishing
- Published
- 2011-01-05
- Volume
- 6
- Issue
- 1
- Pages
- 015007
- ISSN
- 1748-6041 (ISSN-L)
- 1748-605X
- OpenAlex
- W2168824440
- Cited by
- 252
- References
- 42
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.