Isoprene and acetone concentration profiles during exercise on an ergometer
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
A real-time recording setup combining exhaled breath volatile organic compound (VOC) measurements by proton transfer reaction-mass spectrometry (PTR-MS) with hemodynamic and respiratory data is presented. Continuous automatic sampling of exhaled breath is implemented on the basis of measured respiratory flow: a flow-controlled shutter mechanism guarantees that only end-tidal exhalation segments are drawn into the mass spectrometer for analysis. Exhaled breath concentration profiles of two prototypic compounds, isoprene and acetone, during several exercise regimes were acquired, reaffirming and complementing earlier experimental findings regarding the dynamic response of these compounds reported by Senthilmohan et al (2000 Redox Rep. 5 151-3) and Karl et al (2001 J. Appl. Physiol. 91 762-70). While isoprene tends to react very sensitively to changes in pulmonary ventilation and perfusion due to its lipophilic behavior and low Henry constant, hydrophilic acetone shows a rather stable behavior. Characteristic (median) values for breath isoprene concentration and molar flow, i.e., the amount of isoprene exhaled per minute are 100 ppb and 29 nmol min(-1), respectively, with some intra-individual day-to-day variation. At the onset of exercise breath isoprene concentration increases drastically, usually by a factor of ∼3-4 within about 1 min. Due to a simultaneous increase in ventilation, the associated rise in molar flow is even more pronounced, leading to a ratio between peak molar flow and molar flow at rest of ∼11. Our setup holds great potential in capturing continuous dynamics of non-polar, low-soluble VOCs over a wide measurement range with simultaneous appraisal of decisive physiological factors affecting exhalation kinetics. In particular, data appear to favor the hypothesis that short-term effects visible in breath isoprene levels are mainly caused by changes in pulmonary gas exchange patterns rather than fluctuations in endogenous synthesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Self-citationLindinger, W., & Jordan, A. (1998) · Chemical Society Reviews · doi:10.1039/a827347z · Cited by 751
Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04294-u · Cited by 727
Parameters of ventilatory and gas exchange dynamics during exercise
Whipp, B. J., Ward, S. A., Lamarra, N., Davis, J. A., & Wasserman, K. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.52.6.1506 · Cited by 654
LUNG FUNCTION STUDIES. II. THE RESPIRATORY DEAD SPACE
Fowler, W. S. (1948) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1948.154.3.405 · Cited by 567
Turner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379 · cited 1×
“erted to acetone (see above reaction) or to D-betahydroxybutyrate. Acetone is one of the most abundant compounds in human breath. Typical adult exhaled breath concentrations are spread around 600 ppb [27, 47] and plasma concentrations have been quantified as ~ 15 mmol/l [46]. Moreover, a linear relationship between br…”
BackgroundPrediction of lung cancer using volatile biomarkers in breath1
Phillips, M., Altorki, N., Austin, J. H. M., Cameron, R. B., Cataneo, R. N., Greenberg, J., Kloss, R., Maxfield, R. A., Munawar, M. I., Pass, H. I., et al. (2007) · Cancer Biomarkers · doi:10.3233/cbm-2007-3204 · Cited by 323
Mathematical analysis and digital simulation of the respiratory control system.
Grodins, F. S., Buell, J., & Bart, A. J. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.22.2.260 · Cited by 294
Human breath isoprene and its relation to blood cholesterol levels: new measurements and modeling
Karl, T., Prazeller, P., Mayr, D., Jordan, A., Rieder, J., Fall, R., & Lindinger, W. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.2.762 · Cited by 264
Cited by
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Self-citationVolatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Self-citationAmann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Self-citationAssessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Self-citationA European Respiratory Society technical standard: exhaled biomarkers in lung disease
Horváth, I., Barnes, P. J., Loukides, S., Sterk, P. J., Högman, M., Olin, A.-C., Amann, A., Antus, B., Baraldi, E., Bikov, A., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00965-2016 · Cited by 638
Self-citationNoninvasive detection of lung cancer by analysis of exhaled breath
Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Schwarz, K., Ligor, M., Ligor, T., Filipiak, W., Denz, H., Fiegl, M., et al. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-348 · Cited by 597
Self-citationBreath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410
Solid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
A review of breath analysis for diagnosis of human health
Kim, K.-H., Jahan, S. A., & Kabir, E. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.09.013 · Cited by 345
Breath acetone monitoring by portable Si:WO3 gas sensors
Righettoni, M., Tricoli, A., Gass, S., Schmid, A., Amann, A., & Pratsinis, S. E. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.06.002 · Cited by 317
Self-citationBreath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, C., & Turner, C. (2014) · Metabolites · doi:10.3390/metabo4020465 · Cited by 314
Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements
Wang, Z., & Wang, C. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/3/037109 · Cited by 309
Drabińska, N., Flynn, C., Ratcliffe, N., Belluomo, I., Myridakis, A., Gould, O., Fois, M., Smart, A., Devine, T., & Costello, B. D. L. (2021) · Journal of Breath Research · doi:10.1088/1752-7163/abf1d0 · Cited by 288
Sensing Technologies for Detection of Acetone in Human Breath for Diabetes Diagnosis and Monitoring
Saasa, V., Malwela, T., Beukes, M., Mokgotho, M., Liu, C.-P., & Mwakikunga, B. (2018) · Diagnostics · doi:10.3390/diagnostics8010012 · Cited by 287
On-Line Analysis of Exhaled Breath: Focus Review
Bruderer, T., Gaisl, T., Gaugg, M. T., Nowak, N., Streckenbach, B., Müller, S., Moeller, A., Kohler, M., & Zenobi, R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00005 · Cited by 278
Synergy between nanomaterials and volatile organic compounds for non-invasive medical evaluation
Broza, Y. Y., Vishinkin, R., Barash, O., Nakhleh, M. K., & Haick, H. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00317c · Cited by 276
Filipiak, W., Ruzsanyi, V, Mochalski, P., Filipiak, A., Bajtarevic, A., Ager, C., Denz, H., Hilbe, W., Jamnig, H., Hackl, M., et al. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/3/036008 · Cited by 218
Self-citationAnalysis of Exhaled Breath for Disease Detection
Amann, A., Miekisch, W., Schubert, J., Buszewski, B., Ligor, T., Jezierski, T., Pleil, J., & Risby, T. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020043 · Cited by 214
Self-citationMeasuring breath acetone for monitoring fat loss: Review
Anderson, J. C. (2015) · Obesity · doi:10.1002/oby.21242 · Cited by 211
“During graded exercise tests, BrAce increased ( twofold) with exercise intensity (44,46,47), maximum BrAce corresponded to the onset of the lactate threshold (48), and the fat oxidation rate was shown to be logarithmically related to BrAce (44).”
BackgroundNanoscale Sensor Technologies for Disease Detection via Volatolomics
Vishinkin, R., & Haick, H. (2015) · Small · doi:10.1002/smll.201501904 · Cited by 199
Breath acetone as a potential marker in clinical practice
Ruzsányi, V., & Péter Kalapos, M. (2017) · Journal of Breath Research · doi:10.1088/1752-7163/aa66d3 · Cited by 195
Physiological modeling of isoprene dynamics in exhaled breath
King, J., Koc, H., Unterkofler, K., Mochalski, P., Kupferthaler, A., Teschl, G., Teschl, S., Hinterhuber, H., & Amann, A. (2010) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2010.09.028 · Cited by 191
“Isoprene can be regarded as the prototype of an exhaled breath VOC exhibiting pronounced rest-to-work transitions in response to physical activity (Karl et al., 2001; King et al., 2009; Turner et al., 2006).”
BackgroundInfluentialSelf-citationBlood and breath levels of selected volatile organic compounds in healthy volunteers
Mochalski, P., King, J., Klieber, M., Unterkofler, K., Hinterhuber, H., Baumann, M., & Amann, A. (2013) · The Analyst · doi:10.1039/c3an36756h · Cited by 190
Self-citationKing, J., Mochalski, P., Kupferthaler, A., Unterkofler, K., Koc, H., Filipiak, W., Teschl, S., Hinterhuber, H., & Amann, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/008 · Cited by 189
“A detailed description of the entire experimental setup used for acquiring hemodynamic and respiratory data in conjunction with PTR-MS variables is given elsewhere (King et al 2009).”
BackgroundMethodResultInfluentialSelf-citationDigging deeper into volatile organic compounds associated with cancer
Janfaza, S., Khorsand, B., Nikkhah, M., & Zahiri, J. (2019) · Biology Methods and Protocols · doi:10.1093/biomethods/bpz014 · Cited by 176
Mass spectrometry for real-time quantitative breath analysis
Smith, D., Španěl, P., Herbig, J., & Beauchamp, J. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/2/027101 · Cited by 174
Filipiak, W., Filipiak, A., Sponring, A., Schmid, T., Zelger, B., Ager, C., Klodzinska, E., Denz, H., Pizzini, A., Lucciarini, P., et al. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/2/027111 · Cited by 173
Self-citationNoninvasive detection of lung cancer using exhaled breath
Fu, X., Li, M., Knipp, R. J., Nantz, M. H., & Bousamra, M. (2014) · Cancer Medicine · doi:10.1002/cam4.162 · Cited by 166
Das, S., Pal, S., & Mitra, M. (2016) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-016-0164-6 · Cited by 164
Lung cancer biomarkers in exhaled breath
Amann, A., Corradi, M., Mazzone, P., & Mutti, A. (2011) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.10.112 · Cited by 163
Self-citationWilliams, J., Stönner, C., Wicker, J., Krauter, N., Derstroff, B., Bourtsoukidis, E., Klüpfel, T., & Kramer, S. (2016) · Scientific Reports · doi:10.1038/srep25464 · Cited by 105
Metadata
- Authors
- King, J., Kupferthaler, A., Unterkofler, K., Koc, H., Teschl, S., Teschl, G., Miekisch, W., Schubert, J., Hinterhuber, H., & Amann, A.
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2009-06-01
- Volume
- 3
- Issue
- 2
- Pages
- 027006
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W2026962488
- Cited by
- 278
- References
- 51
- FWCI
- 7.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.