Perfusion Improves Tissue Architecture of Engineered Cardiac Muscle
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Cardiac muscle with a certain threshold thickness, uniformity of tissue architecture, and functionality would expand the therapeutic options currently available to patients with congenital or acquired cardiac defects. Cardiac constructs cultured in well-mixed medium had an approximately 100-microm-thick peripheral tissue-like region around a relatively cell-free interior, a structure consistent with the presence of concentration gradients within the tissue. We hypothesized that direct perfusion of cultured constructs can reduce diffusional distances for mass transport, improve control of oxygen, pH, nutrients and metabolites in the cell microenvironment, and thereby increase the thickness and spatial uniformity of engineered cardiac muscle. To test this hypothesis, constructs (9.5-mm-diameter, 2-mm-thick discs) based on neonatal rat cardiac myocytes and fibrous polyglycolic acid scaffolds were cultured either directly perfused with medium or in control spinner flasks. Perfusion improved the spatial uniformity of cell distribution and enhanced the expression of cardiac-specific markers, presumably due to the improved control of local microenvironmental conditions within the forming tissue. Medium perfusion could thus be utilized to better mimic the transport conditions within native cardiac muscle and enable in vitro engineering of cardiac constructs with clinically useful thicknesses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bone marrow cells regenerate infarcted myocardium
Orlic, D., Kajstura, J., Chimenti, S., Jakoniuk, I., Anderson, S. M., Li, B., Pickel, J., McKay, R., Nadal-Ginard, B., Bodine, D. M., et al. (2001) · Nature · doi:10.1038/35070587 · Cited by 5,155
Principles of Tissue Engineering
(2014) · Elsevier eBooks · doi:10.1016/c2011-0-07193-4 · Cited by 1,906
Biodegradable Polymer Scaffolds for Tissue Engineering
Freed, L. E., Vunjak-Novakovic, G., Biron, R. J., Eagles, D. B., Lesnoy, D. C., Barlow, S. K., & Langer, R. (1994) · Nature Biotechnology · doi:10.1038/nbt0794-689 · Cited by 1,235
Self-citationRegenerating functional myocardium: Improved performance after skeletal myoblast transplantation
Taylor, D. A., Atkins, B. Z., Hungspreugs, P., Jones, T. R., Reedy, M. C., Hutcheson, K. A., Glower, D. D., & Kraus, W. E. (1998) · Nature Medicine · doi:10.1038/nm0898-929 · Cited by 1,152
Stem cells in tissue engineering
Bianco, P., & Robey, P. G. (2001) · Nature · doi:10.1038/35102181 · Cited by 965
Tissue Engineering of a Differentiated Cardiac Muscle Construct
Zimmermann, W.-H., Schneiderbanger, K., Schubert, P., Didié, M., Münzel, F., Heubach, J. F., Kostin, S., Neuhuber, W. L., & Eschenhagen, T. (2002) · Circulation Research · doi:10.1161/hh0202.103644 · Cited by 917
Vunjak‐Novakovic, G., Martin, I., Obradovic, B., Treppo, S., Grodzinsky, A. J., Langer, R., & Freed, L. E. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170119 · Cited by 743
Self-citationThe permeability of fibrous porous media
Jackson, G. W., & James, D. F. (1986) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450640302 · Cited by 646
Eschenhagen, T., Fink, C., Remmers, U., Scholz, H., Wattchow, J., Weil, J., Zimmermann, W., Dohmen, H. H., Schäfer, H., Bishopric, N., et al. (1997) · The FASEB Journal · doi:10.1096/fasebj.11.8.9240969 · Cited by 636 · cited 2×
“6,7,9 Constructs were contractile, 6,7 generated tension in response to mechanical, electrical, and chemical stimuli, 5,10,11 and sustained macroscopic signal propagation at rates of 60–400 beats per minute.”
Implantable biohybrid artificial organs
Colton, C. (1995) · Cell Transplantation · doi:10.1016/0963-6897(95)00025-s · Cited by 586
Cited by
The role of bioreactors in tissue engineering
Martin, I., Wendt, D., & Heberer, M. (2004) · Trends in Biotechnology · doi:10.1016/j.tibtech.2003.12.001 · Cited by 1,215
Challenges in tissue engineering
Ikada, Y. (2006) · Journal of The Royal Society Interface · doi:10.1098/rsif.2006.0124 · Cited by 919
Schuurman, W., Levett, P. A., Pot, M. W., van Weeren, P. R., Dhert, W. J. A., Hutmacher, D. W., Melchels, F. P. W., Klein, T. J., & Malda, J. (2013) · Macromolecular Bioscience · doi:10.1002/mabi.201200471 · Cited by 790
Electrical stimulation systems for cardiac tissue engineering
Tandon, N., Cannizzaro, C., Chao, P.-H. G., Maidhof, R., Marsano, A., Au, H. T. H., Radisic, M., & Vunjak-Novakovic, G. (2009) · Nature Protocols · doi:10.1038/nprot.2008.183 · Cited by 528
Self-citationChallenges in Cardiac Tissue Engineering
Vunjak-Novakovic, G., Tandon, N., Godier, A., Maidhof, R., Marsano, A., Martens, T. P., & Radisic, M. (2010) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0352 · Cited by 511
Self-citationEngineered Microenvironments for Controlled Stem Cell Differentiation
Burdick, J. A., & Vunjak-Novakovic, G. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0131 · Cited by 485
“45 46–48 The advantages and limitations of this simple system have driven further developments of perfusion systems.”
Self-citationWendt, D., Marsano, A., Jakob, M., Heberer, M., & Martin, I. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10759 · Cited by 449
Biomaterials for the Treatment of Myocardial Infarction
Christman, K. L., & Lee, R. J. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.06.005 · Cited by 407
Oxygen gradients correlate with cell density and cell viability in engineered cardiac tissue
Radisic, M., Malda, J., Epping, E., Geng, W., Langer, R., & Vunjak‐Novakovic, G. (2006) · Biotechnology and Bioengineering · doi:10.1002/bit.20722 · Cited by 399
Self-citationOsteochondral tissue engineering: Current strategies and challenges
Nukavarapu, S. P., & Dorcemus, D. L. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2012.11.004 · Cited by 383
Biomaterials in cardiac tissue engineering: Ten years of research survey
Chen, Q.-Z., Harding, S. E., Ali, N. N., Lyon, A. R., & Boccaccini, A. R. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.08.001 · Cited by 382
Microintegrating smooth muscle cells into a biodegradable, elastomeric fiber matrix
Stankus, J. J., Guan, J., Fujimoto, K., & Wagner, W. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.06.020 · Cited by 373
Contractile cardiac grafts using a novel nanofibrous mesh
Shin, M., Ishii, O., Sueda, T., & Vacanti, J. P. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.055 · Cited by 359
Possibilities for an in vitro meat production system
Datar, I., & Betti, M. (2010) · Innovative Food Science & Emerging Technologies · doi:10.1016/j.ifset.2009.10.007 · Cited by 345
Cells, scaffolds, and molecules for myocardial tissue engineering
Leor, J., Amsalem, Y., & Cohen, S. (2005) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2004.10.003 · Cited by 344
Medium perfusion enables engineering of compact and contractile cardiac tissue
Radisic, M., Yang, L., Boublik, J., Cohen, R. J., Langer, R., Freed, L. E., & Vunjak-Novakovic, G. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00171.2003 · Cited by 332
Self-citationFunctional cardiac cell constructs on cellulose-based scaffolding
Entcheva, E., Bien, H., Yin, L., Chung, C.-Y., Farrell, M., & Kostov, Y. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.024 · Cited by 327
Biomimetic Approach to Cardiac Tissue Engineering: Oxygen Carriers and Channeled Scaffolds
Radisic, M., Park, H., Chen, F., Salazar-Lazzaro, J. E., Wang, Y., Dennis, R., Langer, R., Freed, L. E., & Vunjak-Novakovic, G. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2077 · Cited by 325
Self-citationKharaziha, M., Nikkhah, M., Shin, S.-R., Annabi, N., Masoumi, N., Gaharwar, A. K., Camci-Unal, G., & Khademhosseini, A. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.04.045 · Cited by 313
High‐density seeding of myocyte cells for cardiac tissue engineering
Radisic, M., Euloth, M., Yang, L., Langer, R., Freed, L. E., & Vunjak‐Novakovic, G. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10594 · Cited by 288
Self-citationHypoxia in Static and Dynamic 3D Culture Systems for Tissue Engineering of Bone
Volkmer, E., Drosse, I., Otto, S., Stangelmayer, A., Stengele, M., Kallukalam, B. C., Mutschler, W., & Schieker, M. (2008) · Tissue Engineering Part A · doi:10.1089/ten.tea.2007.0231 · Cited by 285
Advanced Tools for Tissue Engineering: Scaffolds, Bioreactors, and Signaling
Freed, L. E., Guilak, F., Guo, X. E., Gray, M. L., Tranquillo, R., Holmes, J. W., Radisic, M., Sefton, M. V., Kaplan, D., & Vunjak-Novakovic, G. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.3285 · Cited by 284
Self-citationCardiac tissue engineering using perfusion bioreactor systems
Radisic, M., Marsano, A., Maidhof, R., Wang, Y., & Vunjak-Novakovic, G. (2008) · Nature Protocols · doi:10.1038/nprot.2008.40 · Cited by 273
Self-citationRadisic, M., Deen, W., Langer, R., & Vunjak-Novakovic, G. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00787.2004 · Cited by 269
Self-citationScaffold fabrication by indirect three-dimensional printing
Lee, M., Dunn, J. C. Y., & Wu, B. M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.040 · Cited by 267
Myocardial tissue engineering: a review
Jawad, H., Ali, N. N., Lyon, A. R., Chen, Q. Z., Harding, S. E., & Boccaccini, A. R. (2007) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.46 · Cited by 264
3D Bioprinting for Vascularized Tissue Fabrication
Richards, D., Jia, J., Yost, M., Markwald, R., & Mei, Y. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1653-z · Cited by 234
Tissue engineering for bone defect healing: An update on a multi-component approach
Drosse, I., Volkmer, E., Capanna, R., Biase, P. D., Mutschler, W., & Schieker, M. (2008) · Injury · doi:10.1016/s0020-1383(08)70011-1 · Cited by 202
Cardiovascular tissue engineering
Rabkin, E., & Schoen, F. J. (2002) · Cardiovascular Pathology · doi:10.1016/s1054-8807(02)00130-8 · Cited by 200
“Lisa Freed and Gordana Vunjak-Novakovic and colleagues at MIT to enhance the quality of engineered myocardium by manipulating the bioenvironment in vitro [103–107].”
BackgroundSelf-citationProspectus of cultured meat—advancing meat alternatives
Bhat, Z. F., & Fayaz, H. (2011) · Journal of Food Science and Technology · doi:10.1007/s13197-010-0198-7 · Cited by 197
“Direct perfusion bioreactors appear more appropriate for scaffold based myocyte cultivation allowing flow of medium through a porous scaffold with gas exchange taking place in an external fluid loop (Carrier et al. 2002).”
Bioreactors for Cardiovascular Cell and Tissue Growth: A Review
Barron, V., Lyons, E., Stenson-Cox, C., McHugh, P. E., & Pandit, A. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1603260 · Cited by 182
Jawad, H., Lyon, A. R., Harding, S. E., Ali, N. N., & Boccaccini, A. R. (2008) · British Medical Bulletin · doi:10.1093/bmb/ldn026 · Cited by 181
Cellular cardiomyoplasty and cardiac tissue engineering for myocardial therapy☆
Wang, F., & Guan, J. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.03.001 · Cited by 174
Fibroblast alignment under interstitial fluid flow using a novel 3-D tissue culture model
Ng, C. P., & Swartz, M. A. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01008.2002 · Cited by 174
“One potential rationale for our observations is that the cells realign to align the matrix to alter its mechanical properties, as seen in matrix remodeling in other tissues in response to mechanical stress (2, 12, 24).”
BackgroundBiomimetic approach to cardiac tissue engineering
Radisic, M., Park, H., Gerecht, S., Cannizzaro, C., Langer, R., & Vunjak-Novakovic, G. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2121 · Cited by 168
“In an attempt to enhance mass transport between culture medium and cells within cultured constructs, we later developed a bioreactor with interstitial medium flow (Carrier et al. 2002b).”
InfluentialSelf-citationEngineering vascularised tissues in vitro
Institute for BioMedical Technology, D. O. T. R., Rivron, N., Liu, J., Rouwkema, J., de Boer, J., & van Blitterswijk, C. (2008) · European Cells and Materials · doi:10.22203/ecm.v015a03 · Cited by 168
Cheng, M., Wang, H., Yoshida, R., & Murray, M. M. (2010) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0199 · Cited by 62
“22 In vitro , likewise, sufficient oxygenation of cells by diffusion is limited to a distance of 100–200 m m. 23,24 It has been well recognized that oxygen concentration gradient exists in statically cultured tissue constructs that are larger than few hundred micrometers in thickness.”
Metadata
- Authors
- Carrier, R. L., Rupnick, M., Langer, R., Schoen, F. J., Freed, L. E., & Vunjak-Novakovic, G.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2002-04
- Volume
- 8
- Issue
- 2
- Pages
- 175-188
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2099635527
- Cited by
- 323
- References
- 42
- FWCI
- 12.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.