Predicting Energy Expenditure of Physical Activity Using Hip- and Wrist-Worn Accelerometers
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
To investigate the association between physical activity and health, we need accurate and detailed free-living physical activity measurements. The determination of energy expenditure of activity (EEACT) may also be useful in the treatment and maintenance of nutritional diseases such as diabetes mellitus. Minute-to-minute energy expenditure during a 24-h period was measured in 60 sedentary normal female volunteers (35.4 +/- 9.0 years, body mass index 30.0 +/- 5.9 kg/m2), using a state-of-the-art whole-room indirect calorimeter. The activities ranged from sedentary deskwork to walking and stepping at different intensities. Body movements were simultaneously measured using a hip-worn triaxial accelerometer (Tritrac-R3D, Hemokentics, Inc., Madison, Wisconsin) and a wrist-worn uniaxial accelerometer (ActiWatch AW64, MiniMitter Co., Sunriver, Oregon) on the dominant arm. Movement data from the accelerometers were used to develop nonlinear prediction models (separately and combined) to estimate EEACT and compared for accuracy. In a subgroup (n=12), a second 24-h study period was repeated for cross-validation of the combined model. The combined model, using Tritrac-R3D and ActiWatch, accurately estimated total EEACT (97.7 +/- 3.2% of the measured values, p=0.781), as compared with using ActiWatch (86.0 +/- 4.7%, p<0.001) or Tritrac-R3D (90.0 +/- 4.6%, p<0.001) alone. This model was also accurate for all intensity categories during various physical activities. The subgroup cross-validation also showed accurate and reproducible predictions by the combination model. In this study, we demonstrated that movement measured using accelerometers at the hip and wrist could be used to accurately predict EEACT of various types and intensity of activities. This concept can be extended to develop valid models for the accurate measurement of free-living energy metabolism in clinical populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Physical Activity, All-Cause Mortality, and Longevity of College Alumni
Paffenbarger, R. S., Hyde, R., Wing, A. L., & Hsieh, C.-C. (1986) · New England Journal of Medicine · doi:10.1056/nejm198603063141003 · Cited by 2,742 · cited 1×
“1,2 However, little quantitative evidence has yielded causal relationships, 3,4 mostly because of the large individual and time variations in the characteristics of the parameters of activity and health, and the lack of ability to accurately quantify physical activity.”
Physical Fitness and All-Cause Mortality: A Prospective Study of Healthy Men and Women
Blair, S. N. (1989) · JAMA · doi:10.1001/jama.1989.03430170057028 · Cited by 2,658 · cited 1×
“1,2 However, little quantitative evidence has yielded causal relationships, 3,4 mostly because of the large individual and time variations in the characteristics of the parameters of activity and health, and the lack of ability to accurately quantify physical activity.”
Determinants of 24-hour energy expenditure in man. Methods and results using a respiratory chamber.
Ravussin, E., Lillioja, S., Anderson, T. E., Christin, L., & Bogardus, C. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112749 · Cited by 1,166 · cited 2×
“7 This contribution has significant consequences on overall energy balance, which determines the long-term body weight outcome.”
24-hour energy expenditure and the menstrual cycle
Webb, P. (1986) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/44.5.614 · Cited by 237
Cited by
Age Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors
HILDEBRAND, M., VAN HEES, V. T., HANSEN, B. H., & EKELUND, U. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000289 · Cited by 1,043
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Self-citationDowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Accelerometers and pedometers: methodology and clinical application
Corder, K., Brage, S., & Ekelund, U. (2007) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/mco.0b013e328285d883 · Cited by 339
Ellis, K., Kerr, J., Godbole, S., Lanckriet, G., Wing, D., & Marshall, S. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/11/2191 · Cited by 344
Murphy, S. L. (2009) · Preventive Medicine · doi:10.1016/j.ypmed.2008.12.001 · Cited by 326
Van Remoortel, H., Raste, Y., Louvaris, Z., Giavedoni, S., Burtin, C., Langer, D., Wilson, F., Rabinovich, R., Vogiatzis, I., Hopkinson, N. S., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0039198 · Cited by 323
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Quantifying Real-World Upper-Limb Activity in Nondisabled Adults and Adults With Chronic Stroke
Bailey, R. R., Klaesner, J. W., & Lang, C. E. (2015) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968315583720 · Cited by 261
Estimating Activity and Sedentary Behavior from an Accelerometer on the Hip or Wrist
ROSENBERGER, M. E., HASKELL, W. L., ALBINALI, F., MOTA, S., NAWYN, J., & INTILLE, S. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827f0d9c · Cited by 237
“When walking, jogging or running on the horizontal and the arms are swinging free, an accelerometer on the wrist can provide reasonably accurate information about AEE (4, 5, 45).”
InfluentialMurphy, P. B., Davidson, C., Hind, M. D., Simonds, A., Williams, A. J., Hopkinson, N. S., Moxham, J., Polkey, M., & Hart, N. (2012) · Thorax · doi:10.1136/thoraxjnl-2011-201081 · Cited by 223
Upper Extremity Use in People with Hemiparesis in the First Few Weeks After Stroke
Lang, C. E., Wagner, J. M., Edwards, D. F., & Dromerick, A. W. (2007) · Journal of Neurologic Physical Therapy · doi:10.1097/npt.0b013e31806748bd · Cited by 216
Military applications of soldier physiological monitoring
Friedl, K. E. (2018) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2018.06.004 · Cited by 194
O’Driscoll, R., Turicchi, J., Beaulieu, K., Scott, S., Matu, J., Deighton, K., Finlayson, G., & Stubbs, J. (2020) · British Journal of Sports Medicine · doi:10.1136/bjsports-2018-099643 · Cited by 188
Machine learning for activity recognition: hip versus wrist data
Trost, S. G., Zheng, Y., & Wong, W.-K. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/11/2183 · Cited by 181
“…respect to compliance, calibration studies using regression-based or cut-point approaches show accelerometer data from the hip to provide more accurate estimates of energy expenditure than that collected at the wrist (Chen et al 2003, Rosenberger et al 2013, Swartz et al 2000, Welch et al 2013).”
MethodComparison of Consumer and Research Monitors under Semistructured Settings
BAI, Y., WELK, G. J., NAM, Y. H., LEE, J. A., LEE, J.-M., KIM, Y., MEIER, N. F., & DIXON, P. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000727 · Cited by 149
Toward Objective Monitoring of Ingestive Behavior in Free‐living Population
Sazonov, E. S., Schuckers, S. A. C., Lopez‐Meyer, P., Makeyev, O., Melanson, E. L., Neuman, M. R., & Hill, J. O. (2009) · Obesity · doi:10.1038/oby.2009.153 · Cited by 74
Validation of the Fitbit One® for physical activity measurement at an upper torso attachment site
Diaz, K. M., Krupka, D. J., Chang, M. J., Shaffer, J. A., Ma, Y., Goldsmith, J., Schwartz, J. E., & Davidson, K. W. (2016) · BMC Research Notes · doi:10.1186/s13104-016-2020-8 · Cited by 29
“However, in light of the lower accuracy of the wrist attachment site which some have attributed to smaller amounts of upper body motion during locomotor activities compared to the lower body [8], identification of alternative attachment sites that could improve participant compliance relative to hip-based wear without…”
BackgroundManohar, C. U., Koepp, G. A., McCrady-Spitzer, S. K., & Levine, J. A. (2012) · ICAN: Infant, Child, & Adolescent Nutrition · doi:10.1177/1941406412450644 · Cited by 12
Metadata
- Authors
- Chen, K. Y., Acra, S. A., Majchrzak, K., Donahue, C. L., Baker, L., Clemens, L., Sun, M., & Buchowski, M. S.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2003-12
- Volume
- 5
- Issue
- 6
- Pages
- 1023-1033
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2080635347
- Cited by
- 116
- References
- 5
- FWCI
- 0.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.