Experience with the Continuous Glucose Monitoring System® in a Medical Intensive Care Unit
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Strict glycemic control improves clinical outcomes in critically ill patients. However, practical tools for frequent monitoring of blood glucose (BG) levels in the intensive care unit (ICU) are limited. The Continuous Glucose Monitoring System (CGMS, Medtronic MiniMed, Northridge, CA) is currently approved for detecting glycemic excursions in outpatients with diabetes mellitus. The use of this device has never been carefully examined in the inpatient setting. This preliminary study was designed to investigate the accuracy of the CGMS in critically ill patients admitted to a medical ICU (MICU). Subjects at risk for hyperglycemia were recruited from among all patients admitted to our MICU. CGMS sensors were implanted for up to 72 h. Study subjects wore between one and five consecutive sensors. Four or more standard capillary BG readings were recorded per 24 h. All paired meter-sensor (M-S) readings were used both for CGMS calibration and for data analysis. Twenty-two MICU patients wore 41 CGMS sensors, yielding 546 M-S BG pairs. Overall, the Pearson correlation coefficient ( r ) was 0.88, with a mean M-S difference of 3.3 +/- 26.7 mg/dL (0.6 +/- 17.4%) and a mean absolute M-S difference of 19.7 +/- 18.3 mg/dL (12.8 +/- 11.9%). Clarke Error Grid analysis categorized 98.7% of the M-S pairs within "clinically acceptable" zones A and B. The CGMS is promising for potential use in critically ill patients. If validated in larger studies, the device could serve as a useful research tool for investigating the role of hyperglycemia (and strict glycemic control) in ICU patients. If further developed as a "real-time" glucose sensor, CGMS technology could ultimately prove clinically useful in the ICU, by decreasing nursing workload and/or by providing alarm signals for impending glycemic excursions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
APACHE II: A severity of disease classification system
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Critical Care Medicine · doi:10.1097/00003246-198510000-00009 · Cited by 13,664
APACHE II-A Severity of Disease Classification System: Reply
Knaus, W. A., Draper, E. A., Wagner, D. P., & Zimmerman, J. E. (1986) · Critical Care Medicine · doi:10.1097/00003246-198608000-00028 · Cited by 13,376
Intensive insulin therapy in critically ill patients.
Van den Berghe, G., Wouters, P., Weekers, F., Verwaest, C., Bruyninckx, F., Schetz, M., Vlasselaers, D., Ferdinande, P., Lauwers, P., & Bouillon, R. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011300 · Cited by 9,977
Malmberg, K., Rydén, L., Efendic, S., Herlitz, J., Nicol, P., Waldenstrom, A., Wedel, H., & Welin, L. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00126-k · Cited by 1,560
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Malmberg, K. (1997) · BMJ · doi:10.1136/bmj.314.7093.1512 · Cited by 1,286
Furnary, A. P., Zerr, K. J., Grunkemeier, G. L., & Starr, A. (1999) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(99)00014-4 · Cited by 1,230 · cited 1×
“4,5 Based on these and other clinical studies, there are growing efforts worldwide to better understand the role of hyperglycemia in the ICU, and to improve glycemic control in critically ill patients.”
Glucose Control Lowers the Risk of Wound Infection in Diabetics After Open Heart Operations
Zerr, M., Furnary, M., Grunkemeier, P., Bookin, M., Kanhere, M., & Starr, M. (1997) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(96)01044-2 · Cited by 913
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
The MiniMed Continuous Glucose Monitoring System
Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214078 · Cited by 393 · cited 1×
“7 In clinical practice, it is used primarily for guiding insulin dose adjustments in outpatients with diabetes.”
Rebrin, K., Steil, G. M., van Antwerp, W. P., & Mastrototaro, J. J. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.277.3.e561 · Cited by 366 · cited 1×
“18 The accuracy of the CGMS may improve slightly when calibrations are performed by an experienced nurse.”
Performance Evaluation of the MiniMed® Continuous Glucose Monitoring System During Patient Home Use
Gross, T. M., Bode, B. W., Einhorn, D., Kayne, D. M., Reed, J. H., White, N. H., & Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/152091500316737 · Cited by 303 · cited 1×
“9 Though our study subject numbers were too small for detailed statistical analyses, potentially disruptive clinical issues such as edema, hypotension, and vasopressor therapy (all of which were present in some of our patients) did not appear to affect the accuracy of the CGMS.”
Ludvigsson, J., & Hanas, R. (2003) · Pediatrics · doi:10.1542/peds.111.5.933 · Cited by 228
A Pilot Study of the Continuous Glucose Monitoring System
Kaufman, F. R., Gibson, L. C., Halvorson, M., Carpenter, S., Fisher, L. K., & Pitukcheewanont, P. (2001) · Diabetes Care · doi:10.2337/diacare.24.12.2030 · Cited by 224 · cited 1×
“Though several published studies have demonstrated clinical benefit employing the CGMS in outpatients with diabetes, 20–22 it should be noted that legitimate concerns have been raised about the reproducibility of BG measurements obtained from CGMS monitoring.”
Fingerstick Glucose Determination in Shock
Atkin, S. H., Dasmahapatra, A., Jaker, M. A., Chorost, M. I., & Reddy, S. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-12-1020 · Cited by 189
Reproducibility of Glucose Measurements Using the Glucose Sensor
Metzger, M., Leibowitz, G., Wainstein, J., Glaser, B., & Raz, I. (2002) · Diabetes Care · doi:10.2337/diacare.25.7.1185 · Cited by 134
Efficacy and Reliability of the Continuous Glucose Monitoring System
Gross, T. M., & Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214087 · Cited by 119
Intensive Insulin Therapy in the Intensive Care Unit
De Block, C., Manuel-y-Keenoy, B., Van Gaal, L., & Rogiers, P. (2006) · Diabetes Care · doi:10.2337/dc05-2353 · Cited by 118
Accuracy of the continuous glucose monitoring system in inpatient and outpatient conditions
Djakouré-Platonoff, C., Radermercker, R., Reach, G., Slama, G., & Jl, S. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70023-x · Cited by 74 · cited 1×
“19 To date, however, this technology has not been validated in the inpatient setting.”
Cheyne, E., Cavan, D. A., & Kerr, D. E. (2002) · Diabetes Technology & Therapeutics · doi:10.1089/152091502320798222 · Cited by 71 · cited 1×
“10 Importantly, CGMS measurements appear to be reliable under conditions of hypo-and hyperglycemia, 16,17 and seem unaffected by ambient insulin concentrations.”
Counterpoint: Inpatient Glucose Management
Inzucchi, S. E., & Rosenstock, J. (2005) · Diabetes Care · doi:10.2337/diacare.28.4.976 · Cited by 38
Self-citationContinuous Glucose Monitoring in Previously Unstudied Population Subgroups
Gross, T. M., & ter Veer, A. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214096 · Cited by 34 · cited 1×
“10 Importantly, CGMS measurements appear to be reliable under conditions of hypo-and hyperglycemia, 16,17 and seem unaffected by ambient insulin concentrations.”
Cited by
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470
Moghissi, E. S., Korytkowski, M. T., DiNardo, M., Einhorn, D., Hellman, R., Hirsch, I. B., Inzucchi, S. E., Ismail-Beigi, F., Kirkman, M. S., & Umpierrez, G. E. (2009) · Diabetes Care · doi:10.2337/dc09-9029 · Cited by 1,444
Self-citationKlonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Moghissi, E. S., Korytkowski, M. T., DiNardo, M., Einhorn, D., Hellman, R., Hirsch, I. B., Inzucchi, S. E., Ismail-Beigi, F., Kirkman, M. S., & Umpierrez, G. E. (2009) · Endocrine Practice · doi:10.4158/ep09102.ra · Cited by 518
Self-citationContinuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
Metadata
- Authors
- Goldberg, P. A., Siegel, M. D., Russell, R. R., Sherwin, R. S., Halickman, J. I., Cooper, D. A., Dziura, J. D., & Inzucchi, S. E.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2004-06
- Volume
- 6
- Issue
- 3
- Pages
- 339-347
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2173660670
- Cited by
- 158
- References
- 24
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.