High-Content Assays for Characterizing the Viability and Morphology of 3D Cancer Spheroid Cultures
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
There is an increasing interest in using three-dimensional (3D) spheroids for modeling cancer and tissue biology to accelerate translation research. Development of higher throughput assays to quantify phenotypic changes in spheroids is an active area of investigation. The goal of this study was to develop higher throughput high-content imaging and analysis methods to characterize phenotypic changes in human cancer spheroids in response to compound treatment. We optimized spheroid cell culture protocols using low adhesion U-bottom 96- and 384-well plates for three common cancer cell lines and improved the workflow with a one-step staining procedure that reduces assay time and minimizes variability. We streamlined imaging acquisition by using a maximum projection algorithm that combines cellular information from multiple slices through a 3D object into a single image, enabling efficient comparison of different spheroid phenotypes. A custom image analysis method was implemented to provide multiparametric characterization of single-cell and spheroid phenotypes. We report a number of readouts, including quantification of marker-specific cell numbers, measurement of cell viability and apoptosis, and characterization of spheroid size and shape. Assay performance was assessed using established anticancer cytostatic and cytotoxic drugs. We demonstrated concentration-response effects for different readouts and measured IC50 values, comparing 3D spheroid results to two-dimensional cell cultures. Finally, a library of 119 approved anticancer drugs was screened across a wide range of concentrations using HCT116 colon cancer spheroids. The proposed methods can increase performance and throughput of high-content assays for compound screening and evaluation of anticancer drugs with 3D cell models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Designing materials for biology and medicine
Langer, R., & Tirrell, D. A. (2004) · Nature · doi:10.1038/nature02388 · Cited by 3,198 · cited 1×
“disorders, and have been used for therapeutic screening.(1,34,35) Although in vivo validation remains the gold standard, 3D models can accelerate the process by quickly identifying the most promising targets and establishing mechanisms of action.”
MethodModeling Tissue Morphogenesis and Cancer in 3D
Yamada, K. M., & Cukierman, E. (2007) · Cell · doi:10.1016/j.cell.2007.08.006 · Cited by 1,751
Recent advances in three‐dimensional multicellular spheroid culture for biomedical research
Lin, R., & Chang, H. (2008) · Biotechnology Journal · doi:10.1002/biot.200700228 · Cited by 1,264 · cited 1×
“There has been significant progress in development of 3D cell models and techniques during the last several years.(10,11) Hanging drop techniques use specialized plates(12) and liquid handlers for media change and compound addition processes.”
BackgroundVinci, M., Gowan, S., Boxall, F., Patterson, L., Zimmermann, M., Court, W., Lomas, C., Mendiola, M., Hardisson, D., & Eccles, S. A. (2012) · BMC Biology · doi:10.1186/1741-7007-10-29 · Cited by 1,024 · cited 2×
“Recently, spheroid formation in low-attachment round-bottom plates has become popular as the method offers a more simple workflow and is suitable for high-content imaging.(18) Different biological readouts from spheroid assays have been described.”
BackgroundMethodHigh-throughput 3D spheroid culture and drug testing using a 384 hanging drop array
Tung, Y.-C., Hsiao, A. Y., Allen, S. G., Torisawa, Y.-S., Ho, M., & Takayama, S. (2011) · The Analyst · doi:10.1039/c0an00609b · Cited by 969
The use of 3-d cultures for high-throughput screening: the multicellular spheroid model.
Kunz-Schughart, L. A., Freyer, J. P., Hofstaedter, F., & Ebner, R. (2004) · SLAS DISCOVERY · doi:10.1177/1087057104265040 · Cited by 797 · cited 5×
“adenosine triphosphate or other viability markers with microplate readers.(1) High-content imaging methods have been demonstrated as promising techniques for characterizing the effects of chemical compounds and siRNA libraries on spheroids.”
BackgroundMethodInfluentialEngineering cellular microenvironments to improve cell-based drug testing
Bhadriraju, K., & Chen, C. S. (2002) · Drug Discovery Today · doi:10.1016/s1359-6446(02)02273-0 · Cited by 355
Cited by
Modeling physiological events in 2D vs. 3D cell culture
Duval, K., Grover, H., Han, L.-H., Mou, Y., Pegoraro, A. F., Fredberg, J., & Chen, Z. (2017) · Physiology · doi:10.1152/physiol.00036.2016 · Cited by 1,849
Three-dimensional culture systems in cancer research: Focus on tumor spheroid model
Nath, S., & Devi, G. R. (2016) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2016.03.013 · Cited by 919
Scaffold-based 3D cell culture models in cancer research
Abuwatfa, W. H., Pitt, W. G., & Husseini, G. A. (2024) · Journal of Biomedical Science · doi:10.1186/s12929-024-00994-y · Cited by 324
Barbosa, M. A. G., Xavier, C. P. R., Pereira, R. F., Petrikaitė, V., & Vasconcelos, M. H. (2021) · Cancers · doi:10.3390/cancers14010190 · Cited by 285
“These chemiluminescent assays involve the quantification of a luminescent signal that results from the conversion of luciferin to luciferase, as a consequence of the cytoplasmatic adenosine triphosphate (ATP) concentration [56].”
BackgroundMethodInfluentialLiquid-based three-dimensional tumor models for cancer research and drug discovery
Ham, S. L., Joshi, R., Thakuri, P. S., & Tavana, H. (2016) · Experimental Biology and Medicine · doi:10.1177/1535370216643772 · Cited by 91
Factors to consider when interrogating 3D culture models with plate readers or automated microscopes
Riss, T., & Trask, O. J. (2021) · In Vitro Cellular & Developmental Biology - Animal · doi:10.1007/s11626-020-00537-3 · Cited by 26
“In general, small molecule cell permeable probes such as MTT or calcein-AM to stain live cells or membrane impermeable vital DNA dyes to stain dead cells can eventually penetrate (diffuse) into the center of 3D culture models; but it may take hours (Sirenko et al. 2015).”
BackgroundSirenko, O., Hancock, M. K., Crittenden, C., Hammer, M., Keating, S., Carlson, C. B., & Chandy, G. (2017) · ASSAY and Drug Development Technologies · doi:10.1089/adt.2017.792 · Cited by 20
“27,28 In brief, a Z-stack of 11–17 images separated by 5–10 m m was acquired starting at the well bottom and moving up, covering a light-penetrable fraction of each spheroid ( * 100–120 m m in depth).”
InfluentialSelf-citationMiller, C. P., Fung, M., Jaeger-Ruckstuhl, C. A., Xu, Y., Warren, E. H., Akilesh, S., & Tykodi, S. S. (2023) · Neoplasia · doi:10.1016/j.neo.2023.100948 · Cited by 19
“Conversely, increased drug sensitivity of 3D spheroids compared to 2D monolayers has been shown for other drugs such as EGFR inhibitors and kinase inhibitors [38 – 41], suggesting that for certain antitumor mechanisms, 3D spheroid culture may be a more sensitive platform.”
BackgroundJohnson, P. A., Menegatti, S., Chambers, A. C., Alibhai, D., Collard, T. J., Williams, A. C., Bayley, H., & Perriman, A. W. (2023) · Biofabrication · doi:10.1088/1758-5090/ac999f · Cited by 16
Metadata
- Authors
- Sirenko, O., Mitlo, T., Hesley, J., Luke, S., Owens, W., & Cromwell, E. F.
- Venue
- ASSAY and Drug Development Technologies
- Publisher
- SAGE Publications
- Published
- 2015-09
- Volume
- 13
- Issue
- 7
- Pages
- 402-414
- ISSN
- 1540-658X (ISSN-L)
- 1557-8127
- OpenAlex
- W2399959131
- Cited by
- 204
- References
- 7
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.