CoChat

Response to Nocturnal Alarms Using a Real-Time Glucose Sensor

Open access
Buckingham, Bruce, Block, Jen, Burdick, Jonathan, Kalajian, Andrea, Kollman, Craig, Choy, Michael, Wilson, Darrell M., Chase, Peter · 2005 · Diabetes Technology & Therapeutics
Cited by 115

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The objective of this study was to determine how subjects responded to alarms for hypo- and hyperglycemia while they were sleeping. RESEARCH DESIGN AND METHODS: Twenty subjects with type 1 diabetes (4-17 years old) were admitted to a clinical research center for approximately 24 h. Each subject wore two GlucoWatch G2 Biographers (GW2B) (Cygnus, Inc., Redwood City, CA) and was videotaped using an infrared camera from 9 p.m. to 7 a.m. The videotapes were reviewed to determine if the GW2B alarms were audible on the tape and to document the subject's response to the alarms. Because many alarms can occur surrounding a change in blood glucose, GW2B alarm "events" are defined as a one or more alarms separated from previous alarms by more than 30 min. RESULTS: Downloaded data from the biographers identified 240 individual alarms, 75% of which occurred while the subject was sleeping. Of the 240 alarms 68% were audible on the videotape. Subjects awoke to 29% of individual alarms and to 66% of alarm events. Subjects 4-6 years old responded to 17% of alarms, 7-11 year olds responded to 20% of alarms, adolescents responded to 53% of alarms, and parents responded to 37% of alarms. Subjects awoke to 40% of the first alarm during the night, but to only 28% of subsequent alarms. There were 11 events when the glucose was confirmed to be < or = 70 mg/dL, and in each case the subject was awoken. Fifty-five percent of alarm events occurred when there was no hypo- or hyperglycemia confirmed by a reference glucose value. CONCLUSIONS: Subjects awoke to 29% of individual alarms and to 66% of alarm events. Subjects awoke during all alarm events when hypoglycemia was confirmed, but there was a high incidence of false alarms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2005.7.440

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Buckingham, B., Block, J., Burdick, J., Kalajian, A., Kollman, C., Choy, M., Wilson, D. M., & Chase, P.
Venue
Diabetes Technology & Therapeutics
Published
2005-06
Volume
7
Issue
3
Pages
440-447
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2078706308
Cited by
115
References
2
FWCI
2.19
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.