Pharmacodynamics And Stability of Subcutaneously Infused Glucagon in A Type 1 Diabetic Swine Model In Vivo
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The objective of this study was to determine the in vivo pharmacodynamics of glucagon and to test its glycemic effect over days by assessing its time course of activity and potency in a type 1 diabetic swine model. METHODS: Individual experiments were conducted in different pigs using glucagon preparations that were reconstituted on different days and stored at room temperature or near body temperature before usage. All experiments involved a subcutaneous bolus of glucagon to counter impending hypoglycemia induced by an earlier bolus of fast-acting insulin. Frequent blood-glucose measurements, using a standard in vitro hand-held meter, were taken during each experiment to track variations in blood-glucose concentration. RESULTS: Significant glucagon action was observed as early as 5 min after administration, as evidenced by an effective halt to declining blood glucose and a subsequent twofold rise in blood glucose after approximately 20 min. Results also indicate that the consumption of glucagon from the subcutaneous depot is substantially faster than that of fast-acting insulin. Furthermore, no significant depreciation was observed in glucagon efficacy across aging preparations as old as 7 days. CONCLUSIONS: These results suggest profound utility of subcutaneous glucagon in a closed-loop glucose control system, especially since glucagon would provide an effective safeguarding measure to stave off impending hypoglycemia, an application where the rapid effect of subcutaneous glucagon is both serendipitous and essential. Despite the notion that the stability of glucagon in solution at room temperature is inferior to that of fast-acting insulin, its subcutaneous administration has promising prospects for long-term closed-loop ambulatory care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gerich, J. E., Langlois, M., Noacco, C., Karam, J. H., & Forsham, P. H. (1973) · Science · doi:10.1126/science.182.4108.171 · Cited by 688
An Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
El-Khatib, F. H., Jiang, J., & Damiano, E. R. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100208 · Cited by 99
Self-citationPlum, A., Agersø, H., & Andersen, L. (2000) · Drug Metabolism and Disposition · doi:10.1016/s0090-9556(24)15122-7 · Cited by 56 · cited 1×
“This study reveals (1) that SC dosing of glucagon that is manufactured and intended for humans is remarkably effective in our swine model of diabetes (this observation is consistent with the fact that glucagon is hoPHARMACODYNAMICS OF SC GLUCAGON 141”
Cited by
A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403
“Estimations of the duration of action of subcutaneous doses of glucagon as well as the gains in the PD algorithm were based on pharmacodynamic and closed-loop control studies in diabetic swine (17, 18, 21).”
MethodSelf-citationNovel Use of Glucagon in a Closed-Loop System for Prevention of Hypoglycemia in Type 1 Diabetes
Castle, J. R., Engle, J. M., Youssef, J. E., Massoud, R. G., Yuen, K. C. J., Kagan, R., & Ward, W. K. (2010) · Diabetes Care · doi:10.2337/dc09-2254 · Cited by 232
“(18) have shown that even when glucagon is aged for 1 week at room or body temperature, large doses retain full hyperglycemic activity in animals.”
BackgroundEl-Khatib, F. H., Jiang, J., & Damiano, E. R. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100208 · Cited by 99
Self-citationWard, W. K., Castle, J. R., & Youssef, J. E. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500608 · Cited by 36
Metadata
- Authors
- El-Khatib, F. H., Jiang, J., Gerrity, R. G., & Damiano, E. R.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2007-04
- Volume
- 9
- Issue
- 2
- Pages
- 135-144
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2052860629
- Cited by
- 29
- References
- 4
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pharmacodynamics And Stability of Subcutaneously Infused Glucagon in A Type 1 Diabetic Swine Model In Vivo. https://app.cochat.ai/papers/10.1089/dia.2006.0006
- The paper
- El-Khatib, F. H., Jiang, J., Gerrity, R. G., & Damiano, E. R. (2007). Pharmacodynamics And Stability of Subcutaneously Infused Glucagon in A Type 1 Diabetic Swine Model In Vivo. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2006.0006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.